Records from 1991 to 2025. Most recent: inspection, 4 September 2025.
Documentation record
Registered dimensions (L × B × D)84.8 ft × 24.0 ft × 9.6 ft
Registered tonnagegross 141 / net 96
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJAKOBSON SHIPYARD INC · OYSTER BAY, NY, UNITED STATES · built 1958
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTROY, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 January 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it141 - Regulatory (Subpart C or D), Gross Ton
96 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
4 September 2025
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8227312
27 August 2024
DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7990697
17 August 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7773694
24 May 2022
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7458190
22 April 2021
Initial Certification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7180816
10 January 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4781200
10 January 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4790160
12 April 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4574854
17 July 2012
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4382960
15 June 2006
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2681746
14 November 2005
Type not recorded
No type recorded · Station Oswego · USCG Great Lakes District (CGD-GL) · Activity 2537359
14 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 124072
26 October 1999
MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1131354
4 November 1997
MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1118373
1 October 1997
Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 774940
29 December 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 101060
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2022
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit. Each towing vessel operating on coastwise, or Great Lake routes, must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds.
Vessel needs to add a tourna kit, a means to take blood pressure readings, and replace the expired medication.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 July 2022
Resolution: Vessel had on board a newly purchased first aid kit, with tourniquet and blood pressure cuff.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 May 2022
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370.
The vessel is required to carry 6 day and 6 night visual distress signals. Currently, the vessel does not carry the required type and amount.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 July 2022
Resolution: Vessel had on board newly purchased flare kit to include all required.
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 24 May 2022
Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place.
Acetylene cylinders were sitting flush with the deck and unsecured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 July 2022
Resolution: Acetylene cylinders were secured and mounted to a raised platform on the deck.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 May 2022
Resolved
The portable fire pump must have a minimum capacity of
at least 80 gpm and a discharge gauge pressure of not less than 60 psi, measured at the pump discharge.
Fire pump gage was reading an insufficient pressure of 48 psi at the pump discharge.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 July 2022
Resolution: The vessel's fixed fire pump was now fitted with a gauge and read over 50 psi when measured at the pump.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 May 2022
Resolved
Portable and semi-portable fire extinguishers must be maintained in accordance with NFPA 10.
Semi-portable extinguishers need to be secured in approved brackets or suitably secured to prevent chaffing or dismounting.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2022
Resolved 19 July 2022
Resolution: Semi-portables were secured with newly installed brackets with rubber to prevent chaffing.
Documentation
Issued 1 October 1997
Resolved
NO DRUG TESTING PROGRAM FOR COMPANY/VSL CREW
Condition: Unknown
Due 1 November 1997
Resolved 4 November 1997
Fire Fighting
Issued 1 October 1997
Resolved
PORTABLE FIRE EXTINGUSHERS HAVE NOT BEEN INSPECTED FOR OVER 1 YEAR.
Condition: Unknown
Due 1 November 1997
Resolved 4 November 1997