Records from 1998 to 2026. Most recent: operational control imposed, 7 May 2026.
Inspection history · 26
7 May 2026
PSC A · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8367209
5 May 2026
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8367424
20 November 2025
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8271396
20 November 2025
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8271473
17 November 2025
Administrative Inspection · PSC A
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8265961
10 November 2025
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8266650
2 October 2024
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8012965
29 February 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7872289
1 October 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7801333
26 June 2023
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7724283
22 June 2023
PSC A
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7720573
21 June 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7721807
28 January 2012
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4230782
20 December 2010
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3912479
15 December 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3911253
18 December 2009
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3652094
10 July 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3262508
7 July 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3254603
24 August 2004
ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2175113
18 November 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1950139
19 April 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1788478
22 August 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1664850
25 April 2002
Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1607557
19 May 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 428652
10 May 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 63705
11 June 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 416662
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 May 2026
Resolved
There shall be provided a fixed fire detection and fire alarm system complying with the requirements of regulation 13. The fixed fire detection system shall be capable of rapidly detecting the onset of fire.
PSCO observed that the fire detection system in zone 7 cargo deck 11, and partially in cargo deck 10, was not functioning properly during test.
74 SOLAS(97)II-2/53.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2026
Resolution: Affected smoke alarms in Cargo Zone 7 were restored to normal operation (see documents).
09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 7 May 2026
Resolved
All cargoes, other than solid and liquid bulk cargoes, cargo units and cargo transport units, shall be loaded, stowed, and secured throughout the voyage in accordance with the Cargo Securing Manual. Cargo Securing manual does not address how to secure vehicles with no securing points.
PSCO observed cargo on multiple decks that wsere not secured acording to the ship's cargo securing manual. Cargo securing manual does not address how to secure vehicles with no securing points.
74 SOLAS(04) VI/5.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2026
Resolution: Cargo securing manual was revised to address securing vehicles that had no securing points (see documents)