Records from 1998 to 2025. Most recent: inspection, 4 August 2025.
Inspection history · 53
4 August 2025
COI Inspection · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8190713
28 October 2024
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8025829
11 April 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7893469
20 September 2023
Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7795042
7 September 2022
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7552309
14 October 2021
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7332366
5 August 2020
COI Inspection · Load Line/Change of Employment · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7024591
13 July 2020
Deficiency Check · Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7005416
25 June 2020
Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6985082
7 April 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6936932
6 June 2019
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6705696
31 May 2018
Periodic Inspection · MTSA Verification · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6427593
24 May 2018
Permit to Proceed · Damage Survey · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6423419
26 February 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6361697
16 May 2017
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6147142
7 July 2016
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6027120
20 April 2016
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5858818
18 August 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5219917
17 August 2015
In-Service Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5228618
15 May 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5126021
24 April 2015
DAPI Audit · COI Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5110177
22 April 2015
Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5109872
8 August 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4948079
29 July 2014
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4937429
12 June 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4887447
15 July 2013
Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4655117
24 April 2012
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4293776
31 August 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4134040
19 July 2011
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4086073
2 June 2010
COI Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3755884
7 September 2009
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3588280
5 August 2009
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3556490
22 August 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3305530
25 May 2007
Cargo Tank Internal · Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2927561
1 August 2006
Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2732981
20 May 2005
MTSA Verification · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2363492
3 June 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2087591
9 September 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1902769
23 May 2003
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1821835
6 August 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1656870
3 May 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1612632
29 March 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1598981
26 February 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1489253
8 August 2001
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1069395
13 June 2000
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1397449
31 May 2000
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1420340
18 April 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1376122
24 August 1999
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 780269
28 July 1999
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1108647
23 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807554
21 September 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 500654
3 June 1998
Hull Examination · COI Inspection · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450163
22 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1114954
Construction/Loadline › Structures › Deck Plating
Issued 24 May 2018
Resolved
1. Crop and renew wasted steel in deckhouse floor/cargo tank top, prior to conducting cargo operations. Repairs to be made to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2018
Resolved 31 May 2018
Resolution: Repair completed satisfactory as noted in activity # 6427593.
Operations/Management › Cargo Transfer/Lightering › Use of Vapor Control System
Issued 16 May 2017
Resolved
Update VCS procedures to reflect current barge operations. Specific to portable unit for VCS testing.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 6 June 2017
Resolution: Recived procedure for API plug testing. See attached.
Electrical › Electric Generation Source (service) › Generator
Issued 17 August 2015
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 8 September 2015
Resolved 2 September 2015
Resolution: Received documentation from MSI proving the generator installation is in kind to the approved installation in 2013.
Electrical › Electric Generation Source (service) › Generator
Issued 17 August 2015
Resolved
Make new generator installation available for inspection to the satisfaction of the attending USCG marine inspector.
Action required: 705 - Other - as specified
Due 8 September 2015
Resolved 3 September 2015
Resolution: Visually inspected installation, witnessed low L/O nd overspeed shutdowns.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 29 July 2014
Resolved
Replace gaskets on gauging ports.
Due 11 August 2014
Resolved 11 August 2014
Resolution: All defective gaskets were replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 July 2013
Resolved
Port and starboard nav lights must meet nav rules direct arc of visibility requirements.
Action required: 705 - Other - as specified
Due 31 July 2013
Resolved 31 July 2013
Resolution: O/O flipped navigation lights because they were upside down. Correct arc of visibility has been achieved.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 15 July 2013
Resolved
Correctly mark vapor piping and hoses.
Action required: 705 - Other - as specified
Due 31 July 2013
Resolved 5 August 2013
Resolution: Operator provided pictures of vapor piping showing proper markings at manifold.
Engineering › Fuel Oil Service System › Piping
Issued 15 July 2013
Resolved
Provide properly approved fuel lines for generator.
Action required: 705 - Other - as specified
Due 31 July 2013
Resolved 21 August 2013
Resolution: Aeroquip J1942 hoses and fittings were installed, all sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 15 July 2013
Resolved
Provide proof of testing of cargo pump discharge gauges.
Action required: 705 - Other - as specified
Due 31 July 2013
Resolved 31 July 2013
Resolution: O/O provided provided receipts for the purchase of new cargo pump gauges that have been calibrated.
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 July 2013
Resolved
Make batteries and wiring meet Class 1 Div 1 standards.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2013
Resolution: Batteries were removed from the hazard zone and new, intrinsically safe wiring was run from the batteries to the alarm panel.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 15 July 2013
Resolved
Provide original manufacturer certificate and prove current hydrostatic testing of cargo hoses.
Action required: 705 - Other - as specified
Due 31 July 2013
Resolved 28 August 2013
Resolution: Vessel rep ordered three new hoses and provided manufacturer certs.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 15 July 2013
Resolved
Test emergency shut down on cargo pumps.
Action required: 705 - Other - as specified
Due 31 July 2013
Resolved 31 July 2013
Resolution: Conducted successful emergency shutdown of all pump engines on board.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 15 July 2013
Resolved
Prove proper operation of generator shut downs to satisfaction of attending MI.
Action required: 705 - Other - as specified
Due 31 July 2013
Resolved 5 November 2013
Resolution: Witnessed low lube oil and overspeed shutdowns.
Electrical › Electric Generation Source (service) › Generator
Issued 15 July 2013
Resolved
Submit plans to Mrine Safety Center for the new generator installation. In addition, after plans have been approved, make the generator available for testing and inspection to the satisfaction of the attending CGMI. Prior to operation of generator.
Action required: 705 - Other - as specified
Due 31 July 2013
Resolved 5 November 2013
Resolution: Received e-mail from MSC machinery stating the generator was suitable for installation.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 15 July 2013
Resolved
Clean excess oil from port and stbd cargo pump prime movers.
Due 31 July 2013
Resolved 17 July 2013
Resolution: Verified both engines were wiped clean.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 July 2009
Resolved
-Per 33 CFR 155.1040(a), the Areas of Operation List must be amended to reflect the addition of the Great Lakes COTP zones.
-Per 33 CFR 155.1040(j), the geographic-specific appendix for each COTP zone must include notifications to the appropriate state authorities, including boundary states.
-Per 33 CFR 155.1040(a), the IMO number for the vessel must be verified.
Due 21 August 2009
Resolved 14 December 2009
Resolution: VRP for ASC 257 does not Authorize Great Lakes. (see Narrative Statement.)
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 1 August 2006
Resolved
Properly repair by grinding and welding areas as marked and as described in the narrative. Repairs are to be made at next available drydock or 2008 drydock date, whicherevr is sooner.
Action required: 705 - Other - as specified
Resolved 25 May 2007
Construction/Loadline
Issued 31 May 2000
Resolved
DUE TO CRACK IN WELD ON FORWARD BULKHEAD PORT #1 CARGO TANK AT TANKTOP BAY 3, TANK IS NOT TO BE LOADED CLOSER THAN 1 FOOT OF TANKTOP, NO ENTRY ALLOWEDIN FORWARD RAKE. REINSPECTION REQUIRED BETWEEN 14-16 JUNE 2000 AND PERMINANT REPAIRS ACCOMPLISHED NLT 30 JUNE 2000.
Condition: Unknown
Due 30 June 2000
Resolved 14 June 2000