Records from 2002 to 2025. Most recent: inspection, 6 November 2025.
Documentation record
Registered dimensions (L × B × D)90.6 ft × 29.4 ft × 15.9 ft
Registered tonnagegross 172 / net 7
ITC dimensions (L × B × D)90.6 ft × 29.4 ft × 15.9 ft
ITC tonnagegross 269 / net 80
BuilderDAKOTA CREEK INDUSTRIES · ANACORTES, WA, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKETCHIKAN, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it172 - Regulatory (Subpart C or D), Gross Ton
269 - Convention (Subpart B), Gross Ton
7 - Regulatory (Subpart C or D), Net Ton
80 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
6 November 2025
Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8265368
3 November 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8262409
8 August 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8205481
4 December 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8042203
30 November 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7841893
16 November 2023
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7821911
10 May 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7685411
2 December 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7605311
8 November 2022
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7591653
27 January 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7386880
1 September 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7302015
26 January 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7128451
25 February 2020
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6923500
27 September 2018
Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6550306
30 June 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5974315
4 August 2014
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4955058
14 October 2012
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4464486
30 September 2012
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4455506
4 January 2011
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3920134
1 May 2009
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3465601
28 January 2009
Type not recorded
No type recorded · USCGC BLUE SHARK (WPB 87360) · USCG Northwest District (CGD-NW) · Activity 3423201
12 September 2005
MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2490746
30 January 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1483906
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 November 2025
Resolved
(a) Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use.
(b)if a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move and must be either:(1) A flammable liquid storage cabinet that satisfies UL 1275 (incorporated by reference, see § 136.112 of this subchapter); or(2) A flammable liquid storage cabinet that satisfies FM Approvals Standard 6050 (incorporated by reference, see § 136.112 of this subchapter); or(3) Another suitable steel container that provides an equivalent level of protection.
Vessel had (3) non- approved fiber- glass containers on deck containing paint and gasoline cans, (2) propane tanks also observed in engine room not stored in an approved dedicated storage cabinet or room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2025
Resolved 14 November 2025
Resolution: Recieved pictures of storage containers being empties and flammable gear transferred to steel storage container on deck
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 December 2022
Resolved
Each vessel 79 feet or more in length operating on oceans and coastwise routes that does not have an installed fixed fire-extinguishing system must have two fire fighter's outfits. Vessel's installed CO2 fire extinguishing system, as defined in 46 CFR 136.110, does not meet the CO2 storage requirements of 46 CFR 76.15-20 and cannot be counted as an installed fixed fire-extinguishing system. Vessel does not have two fire fighter's outfits. 46 CFR 142.226(a)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2023
Resolved 20 January 2023
Resolution: Vessel obtained two firefighting outfits
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 December 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas to facilitate egress from each space and must be either: automatic, battery-operated with a duration of no less than 2 hours; or non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Vessel's emergency lighting was missing in internal living areas. 46 CFR 143.410
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2023
Resolved 20 January 2023
Resolution: 02. All internal living spaces were outfitted with luminescent flashlights to allow emergency egress
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 December 2022
Resolved
The master of each towing vessel must keep an accurate list of crewmembers and their assigned positions and responsibilities aboard the vessel. Vessel only logging changes of navigation watch and not list of crewmembers. 46 CFR 140.400
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2023
Resolved 20 January 2023
Resolution: Vessel produced records to indicate posistions of crewmembers
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 December 2022
Resolved
All items identified in 46 CFR 140.915(a) must be recorded in the towing vessel record, official logbook, or in accordance with the TSMS applicable to the vessel. Vessel has completed/documented several of the items in 46 CFR 140.915, but those items are not kept in a single "book, notebook, or electronic record used to document events" as defined in 46 CFR 136.110. 46 CFR 140.915
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2023
Resolved 20 January 2023
Resolution: Vessel has a laptop on board to serve as a way to record events electronically.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 December 2022
Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. Vessel was only completing examination/tests as per 33 CFR 164.80 and not maintaining a navigation assessment as per 46 CFR 140.615. Completion of these assessments are also not be recorded in the towing vessel record, official logbook, or in accordance with the TSMS applicable to the vessel. 46 CFR 140.635
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2023
Resolved 20 January 2023
Resolution: Prior to getting underway vessel is conducting a navigational assesment and logging
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2022
Resolved
Relief valve on air receivers have not been inspected since 2018. Complete relief valve inspection and test
Action required: 10 - Deficiency Rectified
Due 26 February 2022
Resolved 11 February 2022
Resolution: New valves were purchased and installed
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 28 January 2022
Resolved
Line throwing appliance requires 04 complete units. Only 01 unit onboard. Obtain line throwing appliance IAW 46 CFR 160.040
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2022
Resolved 7 November 2022
Resolution: Vessel representative provided proof of having sufficient line throwing appliance with appropriate amount of charges.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 January 2022
Resolved
Fixed and Semi-portable fire extinguisher inspections are out of date. Have syatem inspected to come into compliance.
Action required: 10 - Deficiency Rectified
Resolved 14 February 2022
Resolution: Provided certificate of inspection for extinguishing equipment
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 January 2022
Resolved
Provide proof of Vessel General Permit
Action required: 10 - Deficiency Rectified
Due 26 February 2022
Resolved 11 February 2022
Resolution: Proided proof of VGP
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 January 2019
Resolved
The following essential system alarms must be tested to show proper operation: Main Engine and Auxiliary Engine low lubricating oil pressure; Main Engine and Auxiliary Engine high cooling water temperature; low hydraulic steering fluid level. Provide proof of operation through a third party testing or through company procedures.
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 5 April 2019
Resolution: A third party conducted testing of the essential system alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 November 2018
Resolved
A towing vessel 79 feet or more in length must carry four lifebuoys, At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light. Only two life buoys were on board and only one has a electric light.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2018
Resolved 5 December 2018
Resolution: Two new life buoys were installed and an additional light was installed on the buoy.