MAURY USCG vessel records
← All vessels

CAPT. EDDIE B. III

Built
1971
Last inspected
1 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH9844
Flag
UNITED STATES
Maury page id
psix-46966

Documentation record

Registered dimensions (L × B × D)63.6 ft × 21.9 ft × 6.8 ft
Registered tonnagegross 75 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOUTER BANKS BOAT WORKS · HARKERS ISLAND, NC, UNITED STATES · built 1971
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 28 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KING COD VII Passenger (Inspected) · MISLE 53818 · 6 February 2026 · activity 8309753

Inspection history · 21

1 May 2026 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8359330
3 March 2026 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8319337
6 February 2026 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8309753
14 October 2025 Examination of Repairs · In-Service Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8253564
12 May 2025 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8133498
1 May 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7903568
16 October 2023 Administrative Inspection · Internal Structural Exam · Drydock Exam · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7809056
22 August 2023 Plan Review "T" Boat · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7795172
28 April 2023 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7657535
4 May 2022 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7443553
14 October 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7330885
1 March 2021 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7148025
30 June 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7004898
8 October 2019 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6825875
24 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6650588
11 October 2018 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6560034
19 April 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6382211
20 October 2017 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6292993
4 April 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6117306
21 March 2016 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5837686
16 February 2016 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5815557

Deficiency record · 22

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 May 2025 Resolved
Replace fire hose in kind.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2025
Resolved 12 May 2025
Resolution: Replaced hose.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 May 2025 Resolved
Update medication in 1st aid kit.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 12 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2025 Resolved
Renew life ring float light line.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 12 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 May 2025 Resolved
Prove proper operation of center MDE.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 4 June 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 May 2022 Resolved
Remove phone from engine room and associated wiring. Current configuration is posing more of a hazard than a practical use application. (cleared same day.)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 4 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 May 2022 Resolved
Remove unauthorized electrical connector on port MDE and replace with approved. (Corrected same day.)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2022
Resolved 4 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 May 2022 Resolved
Provide current non expired alcohol test strip. (corrected same day)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2022
Resolved 4 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2021 Resolved
Provide Alcohol Swabs
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 5 April 2021
Resolved 5 April 2021
Resolution: Corrected on the spot
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 March 2021 Resolved
Provide fire buckets.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 5 April 2021
Resolved 1 March 2021
Resolution: Corrected on the spot
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 October 2019 Resolved
Call out to inspect repairs made to port shaft log once complete.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 October 2019
Resolved 13 November 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 October 2019 Resolved
Excavate to good wood and call out to Marine Inspector to discuss repair proposal for starboard shaft strut reinforcement.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 October 2019
Resolved 13 November 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 October 2019 Resolved
Replace wasted aft deck beam in laz. Call out Marine Inspector to discuss repairs to be made to main deck in associated area.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 October 2019
Resolved 13 November 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 October 2019 Resolved
Replace wasted stanchions supporting aft bulwark to transom.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 October 2019
Resolved 13 November 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 October 2019 Resolved
Repair wasted section of forward deck beam port side in laz.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 October 2019
Resolved 13 November 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 October 2019 Resolved
Renew rotted covering boards on port side lax.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 October 2019
Resolved 13 November 2019
Construction/Loadline › Hull › Bracket
Issued 20 October 2017 Resolved
Renew port and starboard shaft logs, both in the engine space, and in the aft space.
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 13 November 2019
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 20 October 2017 Resolved
Determine effectiveness of grounding system and eliminate electrolysis on shaft logs.
Action required: 705 - Other - as specified
Due 31 October 2019
Resolved 13 November 2019
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 April 2017 Resolved
Provide proof of servicing the FF Equipment on board. Prior to carrying passengers.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 12 April 2017
Resolution: rec'd proof of servicing for FF equipment.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 8 April 2016 Resolved
Provide copy of proof of 5-panel testing. (random or pre-employment test results will be acceptable) 46 CFR 16
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 19 April 2016
Resolution: copy provided
Lifesaving › Lifefloat › Retroreflective Material
Issued 8 April 2016 Resolved
Replace faded retro on life floats as needed. 46 CFR 185.604
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 19 April 2016
Resolution: retro replaced
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 8 April 2016 Resolved
Update call sign on Emergency Broadcast placard at operating station. 46 CFR 184.506
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 19 April 2016
Resolution: updated
Engineering › Fuel Oil Service System › Valve
Issued 8 April 2016 Resolved
Properly label fuel shut off valves. 46 CFR 185.608
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 26 April 2016
Resolution: Placards installed.

Ownership record