MAURY USCG vessel records
← All vessels

DISCOVERY

DISCOVERY is a 1998 offshore supply vessel. The Coast Guard has recorded 31 inspections since 2016, most recently in March 2025, along with 69 deficiencies and 3 casualty investigations between 2005 and 2012.

Records from 2005 to 2025. Most recent: inspection, 5 March 2025.

Built
1998
Last inspected
5 March 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9202302
WDF8208
470140
Flag
UNITED STATES
Maury page id
psix-470140

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)183.1 ft × 40.0 ft × 15.0 ft
Registered tonnagegross 447 / net 304
ITC dimensions (L × B × D)183.1 ft × 40.0 ft × 15.0 ft
ITC tonnagegross 883 / net 264
BuilderSTEINER SHIPYARD, INC. · BAYOU LA BATRE, AL, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNIKISKI, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 January 2026 · expires 31 January 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it883 - Convention (Subpart B), Gross Ton
447 - Regulatory (Subpart C or D), Gross Ton
264 - Convention (Subpart B), Net Ton
304 - Regulatory (Subpart C or D), Net Ton
1686 - Dead Weight, Ton
2286 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 31

5 March 2025 Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8088346
30 September 2024 Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8011992
17 June 2024 Administrative Inspection · Plan Review (Other than "T")
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7943080
11 April 2024 Hull Examination · Plan Review (Other than "T") · Administrative Inspection · DAPI Audit · COI Inspection · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7888875
5 December 2023 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7845757
30 November 2023 Examination of Repairs
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7845806
23 December 2022 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7612557
23 March 2022 Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7416079
3 October 2021 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7325694
30 September 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7324318
8 September 2021 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7307798
15 June 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7233086
10 June 2021 Deficiency Check · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7227802
5 May 2021 Plan Review (Other than "T") · Examination of Repairs · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7190351
29 March 2021 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7166082
25 March 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7163056
4 March 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7150567
8 January 2021 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7143753
8 December 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7107674
7 August 2020 MTSA Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7029482
13 June 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6713338
23 January 2019 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6614302
20 December 2018 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6611831
3 December 2018 Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6596591
16 August 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6592372
28 June 2018 Administrative Inspection · Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6458056
23 February 2018 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6361621
30 October 2017 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6297992
20 June 2017 MARPOL Annex I Examination · Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6215097
5 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6053042
3 March 2016 Deficiency Check · Cargo Tank Internal · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5779264

Deficiency record · 69

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2024 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Vessel port Z-drive has failed. Provide repair proposal for CG review and approval, followed by documentation of repair and successful sea trial once complete. 46CFR91.45-1(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2024
Resolution: Technical report uploaded to documents.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 April 2024 Resolved
Post Drug and alcohol assistance poster
Action required: 10 - Deficiency Rectified
Due 12 April 2024
Resolved 12 April 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 April 2024 Resolved
Replace all expired items for all First aids kits onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2024
Resolved 29 April 2024
Resolution: all Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 April 2024 Resolved
provide proof of completing testing of over speed trips for bow thruster .
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 30 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 April 2024 Resolved
Replace all expired 6 volt batteries in life ring Bouy Lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 29 April 2024
Resolution: all sat
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 12 April 2024 Resolved
Install lagging on exhaust side of the bow thruster turbo to prevent crew member from coming in contact with it.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 19 April 2024
Resolution: all sat
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 April 2024 Resolved
Replace 2 broken light cover on the port side of the engine room by port main engine
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 29 April 2024
Resolution: all sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2024 Resolved
install cover on electrical controller box by fire monitor pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 19 April 2024
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 April 2024 Resolved
provide schematic diagram of the system for engine room CO2 system in CO2 storage locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 10 May 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 April 2024 Resolved
Have annual servicing completed on CO2 bottle for paint locker
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 29 April 2024
Resolution: all Sat
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 12 April 2024 Resolved
Provide Electronic charts that meet the requirements in NVIC 01-16
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2024
Resolved 19 April 2024
Resolution: All Sat
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 April 2024 Resolved
Provide a complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room for the methonol pump room
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 10 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 April 2024 Resolved
Find and repair exhaust leak on bow thruster.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 15 May 2024
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 April 2024 Resolved
label all emergency shut down buttons on main deck by both engine room exits
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 10 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 12 April 2024 Resolved
Reinstall shaft guard for bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 19 April 2024
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 April 2024 Resolved
Replace all combustible trash cans with non-combustible ones.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 10 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 April 2024 Resolved
Replace broken oil pressure gauge on Bow Thruster engine
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 15 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2024 Resolved
remove blue painters tape from open breaker opening for the methanol pump and install a proper blank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 19 April 2024
Resolution: all Sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2024 Resolved
Replace alkaline batteries in port side Pilot house Life ring bouy light with required lithium batteries.
Action required: 10 - Deficiency Rectified
Due 11 April 2024
Resolved 12 April 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 January 2024 Resolved
Vessel missed annaul COI Inspection date and must complete a COI inspection prior to conducting commercial operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2024
Resolved 17 April 2024
Resolution: Completed inspection
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 October 2021 Resolved
Vessel must complete gap analyst to go from subchapter L to subchapter I and provide MSC with all required plans for review as per 46 CFR 91.55 required by subchapter I with in 30 Days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 25 October 2021
Resolution: Vessel has sumbited plans to MSC for review.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 1 October 2021 Resolved
Prior to the vessel going on an international voyage or engaging in operations that restrict the movement of the vessel the vessel must install an approved rescue boat davit as per MSC approval letter date July 28, 2021. Once installed testing shall be witnessed by USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 5 October 2021
Resolved 17 April 2024
Resolution: vessel is no longer on a international route
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 August 2021 Resolved
Vessel must complete gap analyst to go from subchapter L to subchapter U and provide MSC with all required plans for review as per 46 CFR 189.55-5 required by subchapter U by Novermber 15th, 2021
Action required: 705 - Other - as specified
Due 15 November 2021
Resolved 4 October 2021
Resolution: vessel no longer wishing to be an Sub U vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 June 2021 Resolved
The minimum instrumentation, alarms, and safety controls required for specific types of systems are listed in Table 62.35-50. See ABS Steel Vessel Rules Part 4-9-4, tables 7A and 8. Stbd Generator rpm gauge reads 1200 rpm if running or not.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 13 July 2021
Resolution: Vessel replaced Tach
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2021 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the machinery shall be made without the knowledge of the [name withheld] end of Gensets were replaced not in kind and do not meet ABS SVR. Installation and testing of generators meeting SVR must be witnessed and approved by the Coast Guard. NLT 22JUL21
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 July 2021
Resolved 15 June 2021
Resolution: Verified installation and tested new generator ends.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 March 2021 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery or equipment shall be made without the knowledge of the [name withheld] of the crane and A-frame installations per the 10-82 approval shall be addressed with the granting OCMI to ensure satisfaction with the ABS review and survey of the plans, installation and testing. NLT 22JUL21
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 July 2021
Resolved 8 September 2021
Resolution: Vessel acquired new Stability Letter from MSC to reflect modifications. 835 rectified.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 March 2021 Resolved
Plans applicable to the vessel must be submitted for Coast Guard review. An electrical load analysis must be prepared IAW Subchapter J and provided to CG MSC for approval for the added lifting equipment and other other items that have been added to the electrical load of the vessel.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 25 August 2021
Resolution: MSC has review has been completed
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 30 March 2021 Resolved
Each cargo vessel must carry at least one rescue boat. The vessel is operating as a freight vessel under the provisions of its COI as a multi cert vessel. Provide plans for rescue boat and launching/recovery appliance install to USCG MSC for approval NLT 24MAY21. Once approved, installation and testing shall be witnessed by the Coast Guard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 May 2021
Resolved 5 October 2021
Resolution: Rescue boat davit requirement cleared and reissued for prior to the vessel going on an international voyage or engaging in operations that restrict the movement of the vessel. Can not update 835
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
If the annual inspection reveals deficiencies in your vessels maintenance, you must make any or all repairs or improvements withing the time period specified by the [name withheld]835 issued on 22FEB2021 has 08 deficiencies that are unresolved and past due.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2021
Resolution: Completed COI inspection.
01 - Certificates & Documentation › 013 - Documents › Records of seafarers' daily hours of work or rest
Issued 22 February 2021 Resolved
The master must post watch schedules where they are easily accessible, must cover each affected person under paragraph a and must take into account rest requirements, port rotations, and the vessel's itinerary. Records of daily hours of rest must be maintained on board the vessel. Each affected person under paragraph (a) of this section must receive a copy of the records pertaining to them, which will be endorsed by the master or by a person authorized by the master and by the seafarer. Vessel was missing posted watch list and records of daily work/rest hours. 46 CFR 15.1111(e)-(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 1 March 2021
Resolution: 01Mar: Watchlist was posted during attendance.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 22 February 2021 Resolved
Each operation described in 33 CFR 151.25(d), (e), and (f) shall be fully recorded without delay in the Oil Record Book (ORB) so that all the entries in the book appropriate to that operation are completed. Each completed operation shall be signed by the person or persons in charge of the operation and signed by the master or other person in charge of the ship. ORB was missing master's signature for 30Dec20. Also missing selection of operation type. Full date entries were also missing from the ORB. 33 CFR 151.25(h), (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 12 April 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 February 2021 Resolved
As appropriate for the intended voyage, all vessels e certificated for ocean or coastwise route, must carry adequate and up-to-date tides and currents. Vessel was missing both tides and currents for 2021. 46 CFR 97.05-5
Action required: 10 - Deficiency Rectified
Resolved 1 March 2021
Resolution: 2021 Tides and currents were on board the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 February 2021 Resolved
It shall be the duty of the master or other person in charge of the vessel to see that all of the provisions of the certificate of inspection are strictly adhered to. The COI requires that all the vessel's service type be entered into the official logbook. The vessel is missing designated service type entries into the official log book. 46 CFR 97.50-1(a)
Action required: 10 - Deficiency Rectified
Resolved 1 March 2021
Resolution: The C/M made an entry into the Official Logbook for the type of service.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 22 February 2021 Resolved
The radio installation must be clearly marked with the call sign, the ship station identity and other codes as applicable for the use of the radio installation. Required markings at the GMDSS are faded. 47 CFR 80.1083(b)(5)
Action required: 10 - Deficiency Rectified
Resolved 1 March 2021
Resolution: The GMDSS was relabeled as required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 February 2021 Resolved
Wire must be in an enclosure. Dead end wires for the fore and aft windshield wipers were exposed and disconnected from its component enclosed in an junction box. 46 CFR 90.25 46 CFR 111.60-11
Action required: 10 - Deficiency Rectified
Due 24 March 2021
Resolved 1 March 2021
Resolution: Both dead end wires were removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 February 2021 Resolved
Each generator must meet the applicable requirements for construction and testing in section 4-8-3 of ABS Steel Vessel rules. The generators were replaced on board and plan review is required for the installation. 46 CFR 90.25 46 CFR 111.12-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 12 April 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2021 Resolved
The inspection for certification shall be such as to insure that the vessel, as regards the structure,is in satisfactory condition and fit for the service for which it is intended, and that it complies with the applicable regulations for such vessel. Provide documentation for the 10-82 review of the cranes installations. 46 CFR 91.25-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 12 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 February 2021 Resolved
Lifesaving appliances and arrangements are subject to tests and inspections described in paragraph (b) of this section during vessel boardings to ensure that the appliances and arrangements comply with applicable requirements, are in satisfactory condition, and remain fit for the service. Multiple lifebuoys were found with improper SOLAS tape, wasted plugs, and wasted lines. 46 CFR 91.25-15 46 CFR 199.45(c)
Action required: 10 - Deficiency Rectified
Due 22 February 2021
Resolved 22 February 2021
Resolution: Corrected on the spot.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 22 February 2021 Resolved
Every person in the required complement of deck officers, including the master on a seagoing vessel equipped with a GMDSS must provide evidence of a valid STCW endorsement as a GMDSS radio operator. Persons performing duties as VSO on-board a seagoing vessel subject to the STCW must hold a valid Coast Guard issued credential with a Vessel Security Officer endorsement. The master on 16Feb2021 attendance did not have a GMDSS or VSO endorsement on his license. 46 CFR 15.515(c) 46 CFR 15.187 33 CFR 104.215(c)
Action required: 10 - Deficiency Rectified
Due 22 February 2021
Resolved 22 February 2021
Resolution: The Chief mate was fleeted up to cover the master position.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 22 February 2021 Resolved
After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel’s trim and stability book, stability letter, Certificate of Inspection, and Load Line Certificate, as the case may be, and then enter an attestation statement of the verification in the log book. The vessel may not depart until it is in compliance with these requirements. The vessel operated after the ABS issued temporary stability letter dated 26Jun2019 expired (26Jun2020).
Action required: 10 - Deficiency Rectified
Due 22 February 2021
Resolved 22 February 2021
Resolution: New stability booklet and LL cert issued by ABS were on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 22 February 2021 Resolved
The assignment of load lines is conditioned upon the structural efficiency and satisfactory stability of the vessel, and upon the provisions provided on the vessel for her effective protection and that of the crew. The temporary stability letter dated 26Jun2019 (expired 26Jun2020) and invalidated the Load Line Certificate. 46 CFR 42.09-1(a)
Action required: 10 - Deficiency Rectified
Due 22 February 2021
Resolved 22 February 2021
Resolution: ABS issued a new LL.
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 22 February 2021 Resolved
Each OSV must provide battery power for the alarm required by 130.460(a)(8): Loss of normal power for the alarm system. During the test of the automation alarms, would annunciate. When the batters were replaced, alarm was never reset to annunciate as required. 46 CFR 130.450(f)
Action required: 10 - Deficiency Rectified
Due 22 February 2021
Resolved 22 February 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 August 2020 Resolved
Provide objective evidence of fire detection system servicing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2020
Resolved 8 October 2020
Resolution: Reviewed objective evidence of servicing.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 August 2020 Resolved
Provide blank cover for galley electrical panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2020
Resolved 8 October 2020
Resolution: Blank installed.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 8 August 2020 Resolved
Provide visible and audible fire alarm in engine room space IAW NVIC 1-78.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2020
Resolved 8 October 2020
Resolution: Visible and audible fire alarm provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 August 2020 Resolved
Uninterrupted power source (UPS) indicated not functioning.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2020
Resolved 8 October 2020
Resolution: UPS functionality verified.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 8 August 2020 Resolved
Notify this office after fire main replacement so that a hydrostatic test can be observed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2020
Resolved 8 October 2020
Resolution: Hydrostatic test complete.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 24 January 2019 Resolved
Oily water separator (OWS) is not operating as designed. Vessel shall retain oily waste onboard while underway and discharge to a certified reception facility until OWS is repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2019
Resolved 14 June 2019
Resolution: OWS was observed being functional during Annual Exam
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 5 December 2018 Resolved
Owner/Operators of DISCOVERY were found to have made repairs without notifying the OCMI.
Action required: 10 - Deficiency Rectified
Due 5 December 2018
Resolved 28 January 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 June 2018 Resolved
Fixed fire extinguishing system shall operate as designed. Service report dated 28Feb18 indicated a problem verifying shutdowns and time delay not adequate. Provide report indicating repair completed and retesting for proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2018
Resolved 6 September 2018
Resolution: Repairs completed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 29 June 2018 Resolved
Periodic tests and inspections shall be made to machinery equipment as indicated in approved Automation Alarm Test Procedures utilizing the Checkoff List. Provide completed Checkoff List tests with dates of test and crewmember initials.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2018
Resolved 24 July 2018
Resolution: Tests completed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 June 2018 Resolved
All systems for detecting smoke and fire, including sensors and alarms, must be inspected and tested. Provide report stating that the fire detection system has had an annual inspection and testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2018
Resolved 6 September 2018
Resolution: repairs completed and system re-tested.
Lifesaving › Inflatable Liferafts › Servicing
Issued 21 June 2017 Resolved
Properly install liferaft on starboard side (not installed after servicing) IAW 46 CFR 133.105.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2017
Deck/Cargo › Cargo Stowage › General
Issued 21 June 2017 Resolved
Properly stow and lash down (6) acetylene bottles on starboard side IAW 46 CFR 125.130.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2017
Communications › Radio Communications › EPIRB
Issued 21 June 2017 Resolved
Properly Install missing EPIRB decal. Verified serviced but decal is not onboard and not installed IAW 47 CFR 80.106(f).
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 23 February 2018
Resolution: Decal Verified
Engineering › Bilge Water Management System › Manifold
Issued 21 June 2017 Resolved
Label bilge manifold piping, labeling space of suction on piping IAW 46 CFR 128.440.
Due 22 June 2017
Resolved 23 June 2017
Communications › Alarms/Indicators › General Alarm
Issued 21 June 2017 Resolved
Repair general alarm lighting in engine room IAW 46 CFR 129.530.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2017
Engineering › Fuel Oil Service System › Hose
Issued 21 June 2017 Resolved
Replace hoses on port MDE IAW 46 CFR 56.60-25.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2017
Engineering › Fuel Oil Service System › Hose
Issued 21 June 2017 Resolved
Replace all oil carrying hoses IAW 46 CFR 56.60-25.
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 23 February 2018
Resolution: Hoses replaced
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 21 June 2017 Resolved
Prove proper operation of audible & visual alarm required for heat detectors in the engine room IAW 46 CFR 130.460 (c).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 21 June 2017 Resolved
Prove proper operation of CO2 discharge in the engine room IAW 46 CFR 132.350.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2017
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 21 June 2017 Resolved
Provide and place onboard approved automation test procedures IAW 46 CFR 130.480.
Due 20 September 2017
Resolved 16 August 2017
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 21 June 2017 Resolved
Properly install ire detection control panel batteries replaced with charge IAW.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2017
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 21 June 2017 Resolved
Update automation procedures to include a procedure for ensuring the overspeed trip(s) on generators are tested.
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 23 February 2018
Resolution: Proceedures amended.
Engineering › Generator (propulsion/auxiliary-electric) › Overcurrent Devices Circuitry
Issued 21 June 2017 Resolved
Provide technical report indicating overspeed test completed on the generators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2017
Resolution: Radtke Marine Inc., Caterpillar Report of 22JUN2017 received. An overspeed condition was created. The RPM was recorded at overspeed trip point, shut down upon set overspeed RPM verified.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 20 June 2017 Resolved
Provide copy of fixed fire extinguishing system servicing certificate IAW 46 CFR 132.250.
Condition: Invalid
Due 20 June 2017
Resolved 22 June 2017
Documentation › Certificates/Documents › Permit, Other
Issued 20 June 2017 Resolved
Provide ABS Class Survey Report last completed,
Due 20 June 2017
Resolved 22 June 2017
Navigation › Collision/Grounding Avoidance › Radar
Issued 5 December 2016 Resolved
26NOV16: Vessel's backup radar was reported inoperable. 46CFR184.404
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2016
Resolved 6 December 2016
Resolution: Technician report received after vessel radar was brought back into operating service.
Stability › Watertight Integrity › General
Issued 3 March 2016 Resolved
Crop and renew lower portion of the watertight door to the methanol room. Replace watertight gasket and prove watertight integrity to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 3 April 2016
Resolved 15 April 2016
Resolution: Inspected watertight door repairs; all sat.

Casualty record · 3

25 December 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2563492
9 December 2011Routine · role: Involved in a Marine Casualty · activity 4220156
19 August 2012Routine · role: Acknowledged Pollution Source · activity 4420403
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEACOR SABRE (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.