MAURY USCG vessel records
← All vessels

CAROLINA ROVER

Built
1998
Last inspected
31 August 2023
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 August 2023
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

470179
Flag
UNITED STATES
Maury page id
psix-470179

Documentation record

Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.0 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROVER MARINE TRANSPORT · OLD TOWN, FL, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portGEORGETOWN, SC
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 47 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FIRST LANDING EXPLORER Passenger (Inspected) · MISLE 1383347 · 20 October 2020 · activity 7084128

Inspection history · 17

31 August 2023 Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7776766
23 August 2023 In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7775205
16 August 2022 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7535995
8 June 2022 Administrative Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7467633
25 February 2022 Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 7411452
2 December 2021 Administrative Inspection · Simplified Stability Test
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7361299
3 June 2021 Examination of Repairs · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7179339
20 October 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7084128
10 September 2020 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7048647
30 March 2020 Hull Examination · Deficiency Check · Drydock Extension · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6933147
10 September 2019 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6790593
10 September 2018 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6552683
5 March 2018 Internal Structural Exam · Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6364707
10 September 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6276210
25 July 2017 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6616218
8 June 2016 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5901316
16 February 2016 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5819647

Deficiency record · 47

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 June 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessing in accordance with the terms of its COI, giving consideration to provisions for necessary facilities for passendgers and crew. The deck for the bathroom has wasted decking as well as various handrails have cracked welds. All repairs to be made at the next dry dock in 2023
Action required: 705 - Other - as specified
Resolved 1 November 2023
Resolution: Vessel missed its COI examination and the COI was deactivated. Will have to undergo a full COI and Drydock examination prior to coming back into passenger service.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 June 2021 Resolved
Vessel required to be equipped with navigational lights. Vessel is not equipped with required navigation lights (mast light) (RULE 23).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 June 2021 Resolved
Vessel required to carry current/up to date marine charts for areas transited. Exsiting marine charts were outdated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 June 2021 Resolved
Vessel required to carry current/up to date navigational publications for areas transited. Existing tidal tables were outdated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2021 Resolved
Vessel required to be equipped with a suitable steering system/arrangement. Existing tie bar end links were found worn requiring replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2021 Resolved
Vessel required to be equipped with suitable steering system/arrangement. Existing flexible hydraulic steering lines were found "crimped".
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2021 Resolved
Vessels batteries are required to be secured to prevent movement. Existing battery boxes were found deteriorated/rotted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 June 2021 Resolved
Vessels visual distress signals are required to be stowed in a portable watertight container. Existing portable container is not watertight and is corroded/wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2021 Resolved
Vessels electrical conductors are required to terminate inside of an enclosure. Dead ended wiring was noted in way of operators console.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 September 2020 Resolved
Vessels hailing port is required to be marked on some clearly visible exterior part of the stern of the vessel. Vessels existing hailing port does not match that of the Certificate of Documentation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 6 September 2021
Resolution: superceded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2020 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Existing fuse holder IWO electrical cabinet is improper type (blade style).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 3 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2020 Resolved
Vessel required to carry a serviceable ring life buoy on board. Existing ring life buoy's peripheral grab line was frayed/damaged by UV.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 16 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2020 Resolved
Batteries in lifesaving appliances shall be renewed annually. Battery in way of floating water light for ring life buoy required annual replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 16 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 September 2020 Resolved
Vessel required to post emegency instructions on board IAW 46 CFR 185.512. Existing emergency instructions are incomplete and are not in compliance with 46 CFR 185.512.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 16 April 2021
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 10 September 2020 Resolved
Vessels with installed toilets shall have operating instructions posted. Vessel is equipped with an installed Type III MSD system. Existing system has incomplete operating instructions.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 16 April 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 September 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 16 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 September 2020 Resolved
A seat must be constructed to minimize the possibility of injury and avoid trapping occupants. Existing seating hardware found loose in way of Row 1 (port) and Row 3 (starboard).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 3 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 September 2020 Resolved
Vessel required to be equipped with proper sound signals (bell). Existing sound signal (bell) missing striker.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2020
Resolved 16 April 2021
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 May 2020 Resolved
During drydock inspection, all accessible parts of the vessels underwater body and all through hull fittings shall be made available for inspection. Fractured FRP noted IWO starboard transom (@ engine mounting location).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2020
Resolution: Attending Inspector verified repairs made to starboard transom.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2020 Resolved
During drydock inspection, all accessible parts of the vessels underwater body and all through hull fittings shall be made available for inspection. Fractured securing devices noted IWO centerline deck structure (below main deck) for electrical conductors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 22 May 2020
Resolution: Attending Inspector verified renewal of clamps for electrical conductors.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 May 2020 Resolved
During drydock inspection, all accessible parts of the vessels underwater body and all through hull fittings shall be made available for inspection. Delamination of FRP overlay IWO starboard bow.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 22 May 2020
Resolution: Attending Inspector verified repairs made IWO starboard bow.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2020 Resolved
An internal structural examination may be conducted while the vessel is out of the water. Attending Inspector(s) identified wasted mechanical clamps IWO electric bilge pump discharge flexible hose/piping.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 22 May 2020
Resolution: Attending Inspector verified renewal of hose clamps IWO electric submersible bilge pumps.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2018 Resolved
Ring life buoy required to be marked with retro-reflective markings/tape. Vessels ring life buoy was missing required retro-reflective markings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 28 November 2018
Resolution: Attending Inspector verified retro-reflective markings for ring life buoy.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 September 2018 Resolved
Vessel required to carry suitable first aid kit for service engaged in. Attending Inspectors identified expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 28 November 2018
Resolution: Attending Inspector verified renewal of expired items in first aid kit.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 September 2018 Resolved
Vessel is required to be documented. Vessel is not equipped with a valid Certificate of Documentation. Vessels hailing port does not match Certificate of Documentation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 10 September 2019
Resolution: Attending Inspector verified carriage/validity of vessel Certificate of Documentation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2018 Resolved
Vessel required to carry Type I PFD's for each person on board properly sized. Vessel was missing two Type I adult PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 September 2018
Resolved 28 November 2018
Resolution: Attending Inspector verified the carriage of proper qty of Type I PFD's (adult).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2018 Resolved
PFD stowage locations are required to be marked with size/qty. One of the vessels stowage locations was not properly marked with size/qty of Type I PFD's.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 28 November 2018
Resolution: Attending Inspector verified renewal of PFD stowage markings.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2018 Resolved
Attending Inspector(s) identified fractured weldments IWO bow doors, port & starboard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 2 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 September 2018 Resolved
Vessel required to be equipped with bilge piping system. Vessels bilge discharge piping IWO starboard void #2 was found leaking during operational testings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 28 November 2018
Resolution: Attending Inspector verified repairs made to electric submersible bilge piping hoses/connections.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 September 2018 Resolved
Vessel's emergency lighting was found extinguished during operatonal testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 28 November 2018
Resolution: Attending Inspector verified operation of main deck lighting.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2018 Resolved
Gouges noted IWO port quarter gel coat/FRP IWO side shell & transom.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 2 February 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2018 Resolved
Attending Inspector(s) identified delamination of FRP IWO starboard transom @ outboard motor mountings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 2 February 2019
Construction/Loadline › Hull › Bottom Plating
Issued 5 March 2018 Resolved
Grind existing FRP overlay from port & starboard sponsons due to deterioration/wear.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 28 March 2018
Resolution: Attending Inspector(s) verified repairs made IWO FRP overlay for port/starboard sponsons.
Construction/Loadline › Hull › Hull Plating
Issued 5 March 2018 Resolved
Grind/fill existing chips/gouges in FRP IWO port & starboard sponsons (where marked by attending Inspector)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 28 March 2018
Resolution: Attemding Inspector(s) verified repairs made IWO gel coat throughout vessels hull (where marked).
Construction/Loadline › Hull › Hull Plating
Issued 5 March 2018 Resolved
Effect repairs IWO port quarter sponson.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 28 March 2018
Resolution: Attending Inspector(s) verified repairs made IWO port quarter sponson.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 March 2018 Resolved
Properly secure electrical conductors beneath main deck (centerline).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 28 March 2018
Resolution: Attending Inspector(s) verified installation of securing devices for cableways/conductors along the bottom of the main deck.
Engineering › Bilge Water Management System › Pump
Issued 5 March 2018 Resolved
Repair/replace existing electric submersible bilge pump IWO starboard Void #2.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2018
Resolution: Attending Inspector(s) verified repairs made to electric submersible bilge pump IWO Starboard Void #2.
Documentation › Certificates/Documents › FCC SSL
Issued 10 September 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 31 October 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 10 September 2017 Resolved
VHF-FM radiotelephone is not properly programmed with MMSI # (DSC equipped).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 31 October 2017
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 10 September 2017 Resolved
Vessels owner/operator could not produce proof of enrollment letter form consortium.
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 26 October 2017
Resolution: Attending Inspector(s) verified enrollment into an approved drug/alcohol testing consortium.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 10 September 2017 Resolved
Vessels does not carry/post EAP (policy) on board.
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 31 October 2017
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 10 September 2017 Resolved
Vessel does not carry/post emergency instructions.
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 31 October 2017
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 September 2017 Resolved
Vessels navigation publications were out of date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 31 October 2017
Navigation › Piloting/Steering › Marine Charts
Issued 10 September 2017 Resolved
Vessels marine charts for areas transited were out of date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 26 October 2017
Resolution: Attending Inspector(s) verified carriage of current/up to date marine charts for areas transited.
Lifesaving › Lifebuoys › Serviceable
Issued 10 September 2017 Resolved
Vessels ring buoy required replacement due to UV damage to outer covering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 26 October 2017
Resolution: Attending Inspector(s) verified replacement of ring life buoy.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 September 2017 Resolved
Expired items were identified in First Aid Kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 26 October 2017
Resolution: Attending Inspector(s) verified renewal of expired items in first aid kit.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 September 2017 Resolved
Vessels emergency fuel shut off piping/valves were found "loose" (required repair/replacement).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 26 October 2017
Resolution: Attending Inspector(s) verified repairs made to emergency fuel shut off valves/piping.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.