02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 June 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessing in accordance with the terms of its COI, giving consideration to provisions for necessary facilities for passendgers and crew. The deck for the bathroom has wasted decking as well as various handrails have cracked welds. All repairs to be made at the next dry dock in 2023
Action required: 705 - Other - as specified
Resolved 1 November 2023
Resolution: Vessel missed its COI examination and the COI was deactivated. Will have to undergo a full COI and Drydock examination prior to coming back into passenger service.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 June 2021
Resolved
Vessel required to be equipped with navigational lights. Vessel is not equipped with required navigation lights (mast light) (RULE 23).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 June 2021
Resolved
Vessel required to carry current/up to date marine charts for areas transited. Exsiting marine charts were outdated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 June 2021
Resolved
Vessel required to carry current/up to date navigational publications for areas transited. Existing tidal tables were outdated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2021
Resolved
Vessel required to be equipped with a suitable steering system/arrangement. Existing tie bar end links were found worn requiring replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2021
Resolved
Vessel required to be equipped with suitable steering system/arrangement. Existing flexible hydraulic steering lines were found "crimped".
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2021
Resolved
Vessels batteries are required to be secured to prevent movement. Existing battery boxes were found deteriorated/rotted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 June 2021
Resolved
Vessels visual distress signals are required to be stowed in a portable watertight container. Existing portable container is not watertight and is corroded/wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2021
Resolved
Vessels electrical conductors are required to terminate inside of an enclosure. Dead ended wiring was noted in way of operators console.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2021
Resolved 6 September 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 September 2020
Resolved
Vessels hailing port is required to be marked on some clearly visible exterior part of the stern of the vessel. Vessels existing hailing port does not match that of the Certificate of Documentation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 6 September 2021
Resolution: superceded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2020
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Existing fuse holder IWO electrical cabinet is improper type (blade style).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 3 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2020
Resolved
Vessel required to carry a serviceable ring life buoy on board. Existing ring life buoy's peripheral grab line was frayed/damaged by UV.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 16 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2020
Resolved
Batteries in lifesaving appliances shall be renewed annually. Battery in way of floating water light for ring life buoy required annual replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 16 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 September 2020
Resolved
Vessel required to post emegency instructions on board IAW 46 CFR 185.512. Existing emergency instructions are incomplete and are not in compliance with 46 CFR 185.512.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 16 April 2021
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 10 September 2020
Resolved
Vessels with installed toilets shall have operating instructions posted. Vessel is equipped with an installed Type III MSD system. Existing system has incomplete operating instructions.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2020
Resolved 16 April 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 September 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 16 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 September 2020
Resolved
A seat must be constructed to minimize the possibility of injury and avoid trapping occupants. Existing seating hardware found loose in way of Row 1 (port) and Row 3 (starboard).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 3 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 September 2020
Resolved
Vessel required to be equipped with proper sound signals (bell). Existing sound signal (bell) missing striker.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2020
Resolved 16 April 2021
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 May 2020
Resolved
During drydock inspection, all accessible parts of the vessels underwater body and all through hull fittings shall be made available for inspection. Fractured FRP noted IWO starboard transom (@ engine mounting location).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2020
Resolution: Attending Inspector verified repairs made to starboard transom.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2020
Resolved
During drydock inspection, all accessible parts of the vessels underwater body and all through hull fittings shall be made available for inspection. Fractured securing devices noted IWO centerline deck structure (below main deck) for electrical conductors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 22 May 2020
Resolution: Attending Inspector verified renewal of clamps for electrical conductors.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 May 2020
Resolved
During drydock inspection, all accessible parts of the vessels underwater body and all through hull fittings shall be made available for inspection. Delamination of FRP overlay IWO starboard bow.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 22 May 2020
Resolution: Attending Inspector verified repairs made IWO starboard bow.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2020
Resolved
An internal structural examination may be conducted while the vessel is out of the water. Attending Inspector(s) identified wasted mechanical clamps IWO electric bilge pump discharge flexible hose/piping.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 22 May 2020
Resolution: Attending Inspector verified renewal of hose clamps IWO electric submersible bilge pumps.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2018
Resolved
Ring life buoy required to be marked with retro-reflective markings/tape. Vessels ring life buoy was missing required retro-reflective markings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 28 November 2018
Resolution: Attending Inspector verified retro-reflective markings for ring life buoy.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 September 2018
Resolved
Vessel required to carry suitable first aid kit for service engaged in. Attending Inspectors identified expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 28 November 2018
Resolution: Attending Inspector verified renewal of expired items in first aid kit.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 September 2018
Resolved
Vessel is required to be documented. Vessel is not equipped with a valid Certificate of Documentation. Vessels hailing port does not match Certificate of Documentation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 10 September 2019
Resolution: Attending Inspector verified carriage/validity of vessel Certificate of Documentation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2018
Resolved
Vessel required to carry Type I PFD's for each person on board properly sized. Vessel was missing two Type I adult PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 September 2018
Resolved 28 November 2018
Resolution: Attending Inspector verified the carriage of proper qty of Type I PFD's (adult).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2018
Resolved
PFD stowage locations are required to be marked with size/qty. One of the vessels stowage locations was not properly marked with size/qty of Type I PFD's.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 28 November 2018
Resolution: Attending Inspector verified renewal of PFD stowage markings.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2018
Resolved
Attending Inspector(s) identified fractured weldments IWO bow doors, port & starboard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 2 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 September 2018
Resolved
Vessel required to be equipped with bilge piping system. Vessels bilge discharge piping IWO starboard void #2 was found leaking during operational testings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 28 November 2018
Resolution: Attending Inspector verified repairs made to electric submersible bilge piping hoses/connections.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 September 2018
Resolved
Vessel's emergency lighting was found extinguished during operatonal testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2018
Resolved 28 November 2018
Resolution: Attending Inspector verified operation of main deck lighting.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2018
Resolved
Gouges noted IWO port quarter gel coat/FRP IWO side shell & transom.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 2 February 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 September 2018
Resolved
Attending Inspector(s) identified delamination of FRP IWO starboard transom @ outboard motor mountings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 2 February 2019
Construction/Loadline › Hull › Bottom Plating
Issued 5 March 2018
Resolved
Grind existing FRP overlay from port & starboard sponsons due to deterioration/wear.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 28 March 2018
Resolution: Attending Inspector(s) verified repairs made IWO FRP overlay for port/starboard sponsons.
Construction/Loadline › Hull › Hull Plating
Issued 5 March 2018
Resolved
Grind/fill existing chips/gouges in FRP IWO port & starboard sponsons (where marked by attending Inspector)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 28 March 2018
Resolution: Attemding Inspector(s) verified repairs made IWO gel coat throughout vessels hull (where marked).
Construction/Loadline › Hull › Hull Plating
Issued 5 March 2018
Resolved
Effect repairs IWO port quarter sponson.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 28 March 2018
Resolution: Attending Inspector(s) verified repairs made IWO port quarter sponson.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 March 2018
Resolved
Properly secure electrical conductors beneath main deck (centerline).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 28 March 2018
Resolution: Attending Inspector(s) verified installation of securing devices for cableways/conductors along the bottom of the main deck.
Engineering › Bilge Water Management System › Pump
Issued 5 March 2018
Resolved
Repair/replace existing electric submersible bilge pump IWO starboard Void #2.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2018
Resolution: Attending Inspector(s) verified repairs made to electric submersible bilge pump IWO Starboard Void #2.
Documentation › Certificates/Documents › FCC SSL
Issued 10 September 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 31 October 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 10 September 2017
Resolved
VHF-FM radiotelephone is not properly programmed with MMSI # (DSC equipped).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 31 October 2017
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 10 September 2017
Resolved
Vessels owner/operator could not produce proof of enrollment letter form consortium.
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 26 October 2017
Resolution: Attending Inspector(s) verified enrollment into an approved drug/alcohol testing consortium.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 10 September 2017
Resolved
Vessels does not carry/post EAP (policy) on board.
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 31 October 2017
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 10 September 2017
Resolved
Vessel does not carry/post emergency instructions.
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 31 October 2017
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 September 2017
Resolved
Vessels navigation publications were out of date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 31 October 2017
Navigation › Piloting/Steering › Marine Charts
Issued 10 September 2017
Resolved
Vessels marine charts for areas transited were out of date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 26 October 2017
Resolution: Attending Inspector(s) verified carriage of current/up to date marine charts for areas transited.
Lifesaving › Lifebuoys › Serviceable
Issued 10 September 2017
Resolved
Vessels ring buoy required replacement due to UV damage to outer covering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 26 October 2017
Resolution: Attending Inspector(s) verified replacement of ring life buoy.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 September 2017
Resolved
Expired items were identified in First Aid Kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 26 October 2017
Resolution: Attending Inspector(s) verified renewal of expired items in first aid kit.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 September 2017
Resolved
Vessels emergency fuel shut off piping/valves were found "loose" (required repair/replacement).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2017
Resolved 26 October 2017
Resolution: Attending Inspector(s) verified repairs made to emergency fuel shut off valves/piping.