Records from 2016 to 2021. Most recent: inspection, 29 May 2021.
Inspection history · 14
29 May 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7226175
28 April 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7190644
16 September 2020
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7059330
8 January 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6883522
2 June 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6817602
30 March 2019
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6652659
20 December 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6600660
29 November 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6589298
27 August 2018
Deadweight Survey
Physical examination · Outer Continental Shelf National Center of Expertise · Activity 6532067
27 August 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6532959
22 September 2017
In-Service Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6280198
8 August 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6234578
12 October 2016
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6021715
1 April 2016
Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5848983
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 September 2017
Resolved
Fire doors leading to stairtowers were found with rusted frames jeopardizing A class boundaries.
Action required: 705 - Other - as specified
Due 22 October 2017
Resolved 8 January 2018
Resolution: Letter from [name withheld] with information for closure.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 22 September 2017
Resolved
Galley roll down shutters do not close completely.
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 8 January 2018
Resolution: Letter from [name withheld] with information for closure.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 22 September 2017
Resolved
Fire/Safety Plan does not list fire doors, B class boundaries, or portable accomodation modules.
Action required: 705 - Other - as specified
Due 22 October 2017
Resolved 6 June 2018
Resolution: Letter from [name withheld] with information for closure. Will stamp when onboard. Reviewed them and concur with operator validation.
Fire Fighting › Nozzles › Condition
Issued 22 September 2017
Resolved
The following emergency equipment was not maintained: fire nozzles were jammed and reel stations had leaks, eyewash station pressure was not operational, and limit switches on Lifeboat 4 would not reset due to access paint.
Action required: 705 - Other - as specified
Due 22 October 2017
Resolved 31 October 2017
Resolution: Letter from [name withheld] with information for closure.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 September 2017
Resolved
NE and SW obstruction lights were installed incorrectly and had condensation in the lense.
Action required: 705 - Other - as specified
Due 22 October 2017
Resolved 14 December 2017
Resolution: Letter from [name withheld] with information for closure.
Lifesaving › Rescue Boat › Construction
Issued 22 September 2017
Resolved
Fast rescue boat davit and releasing gear are missing data plates.
Action required: 705 - Other - as specified
Due 22 October 2017
Resolved 26 February 2018
Resolution: Letter from [name withheld] with information for closure.