MAURY USCG vessel records Sign in
← All vessels

C-ESCORT

C-ESCORT is a 2000 offshore supply vessel. The Coast Guard has recorded 35 inspections since 1999, most recently in July 2020, along with 22 deficiencies and 2 casualty investigations between 2006 and 2008.

Records from 1999 to 2020. Most recent: inspection, 30 July 2020.

Built
2000
Last inspected
30 July 2020
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9226293 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCZ6022
508516
Flag
UNITED STATES
338664000 (licence lapsed)
Maury page id
psix-508516

Inspections, by type

…with no type recorded8
Years with a record 18 calendar years (1999–2020)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)221.6 ft × 56.0 ft × 21.0 ft
Registered tonnagegross 2,092 / net 627
ITC dimensions (L × B × D)221.6 ft × 56.0 ft × 21.0 ft
ITC tonnagegross 2,092 / net 627
BuilderNO AMERICAN FABRICATORS · HOUMA, LA, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 June 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2092 - Convention (Subpart B), Gross Ton
3233 - Dead Weight, Ton
627 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ6022MMSI 338664000 · expired · compulsorily equipped · granted 11 November 2009, cancelled 22 February 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GENESIS SPAR Industrial Vessel · MISLE 470467 · 11 August 2006 · activity 2775663CEDAR RIVER Offshore Supply Vessel · MISLE 48515 · 21 September 2000 · activity 101431RED RIVER Offshore Supply Vessel · MISLE 54040 · 21 September 2000 · activity 101431

Inspection history · 35

30 July 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7020303
24 July 2017 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6230639
2 April 2017 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6092463
22 August 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5987850
10 December 2015 COI Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5761088
12 February 2012 ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4246513
22 July 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4090781
1 November 2010 ACP Handover Survey · Construction Oversight · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3882395
5 February 2010 Cargo Tank Internal · Hull Examination · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3676238
11 February 2009 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3412267
24 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3213460
20 February 2008 Cargo Tank Internal · Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3150444
19 January 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3135439
15 January 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3130890
2 February 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2867388
19 September 2006 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2783274
16 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2749804
16 August 2006 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750283
11 August 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2775663
15 February 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2585500
27 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502017
26 July 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2448670
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2294015
7 February 2005 Internal Structural Exam · MTSA Verification · Hull Examination · Cargo Tank Internal · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2287757
24 March 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2030240
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979616
11 February 2003 Re-Inspection · Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1742822
28 March 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1598364
10 April 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456962
19 January 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 10842
21 September 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 101431
21 September 2000 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1053696
17 February 2000 Initial Certification · Initial Construction-Excluding Oversight · Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386714
9 January 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 814494
30 September 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348732

Deficiency record · 22

Stability › Watertight Integrity › General
Issued 2 April 2017 Resolved
Vessels engine room ventilation duct was missing closing devices to make forward engine room water tight bhd watertight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2017
Resolved 2 April 2017
Resolution: Vessels crew found the missing closing devices and installed, tested satisfactory as designed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Injector (fuel injection)
Issued 2 April 2017 Resolved
Vessels #1 and #2 generator had loose and chaffed piping on its high pressure F/O lines.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2017
Resolved 2 April 2017
Resolution: Vessels crew replaced high pressure line and tightened loose fittings and conducted operational test.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 April 2017 Resolved
Vessels port and stbd embarkation ladders were damaged and had cracked ladder runs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2017
Resolved 2 April 2017
Resolution: Crew replaced both embarkation ladders with new ladders.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 22 August 2016 Resolved
Installed 40hp Evinrude inop. OCMI authorized replacement with 40hp Mariner for 1 voyage only. Repair/replace in kind upon return to port on or about 7 Sep 16 and provide class report to CG Marine Inspector.
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 9 September 2016
Resolution: Replaced FRC engine with like kind and hp. Test run SAT. All requirements met.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 11 February 2009 Resolved
Audible alarm for Steering failure alarm was disabled by Master. Master stated the alarm goes off continually. Further investigation revealed the steering failure alarm not working properly. Master stated the alarm has been worked on an calibrated but fails shortly after calibration. Inspector feels the alarm system is a design failure and should be repaired.
Action required: 705 - Other - as specified
Resolved 26 February 2009
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 11 February 2009 Resolved
Install 1 barrel capacity containment under emergency generator fuel vent. This can be accomplished next DD 2010
Due 30 November 2010
Resolved 9 February 2010
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 15 January 2008 Resolved
Renew vsl's hard copies of Tide Tables and Tide Current Tables with 2008 edition.
Due 15 February 2008
Resolved 17 January 2008
Fire Fighting › Fire Main › Material
Issued 16 August 2006 Resolved
Upon completion of fire monitor repairs, hydro test both monitors.
Action required: 705 - Other - as specified
Resolved 2 February 2007
Resolution: Cleared.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 February 2006 Resolved
PROVIDE THIRD PARTY SERVICING FOR OILY WATER SEPARATOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2006
Resolved 17 February 2006
Resolution: Completed repair of OWS
Accommodation/Occupational Safety › Ventilation › General
Issued 24 March 2004 Resolved
Reconfigure ventilation system located in the air conditioning space on the 02-deck level containing batteries. LEGACY COMPONENT DESC: Air Conditioning space
Action required: 705 - Other - as specified
Due 24 April 2004
Resolved 22 February 2005
Stability › Watertight Integrity
Issued 11 February 2003 Resolved
Replace gaskets on (3) doors located in the paint locker, 01 deck passageway and in the stbd. stack. LEGACY COMPONENT DESC: Watertight Doors
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2003
Resolved 13 February 2003
Stability › Watertight Integrity
Issued 11 February 2003 Resolved
Adjust doors as marked. LEGACY COMPONENT DESC: Watertight Doors
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2003
Resolved 13 February 2003
Engineering › Fuel Oil Service System
Issued 11 February 2003 Resolved
Replace fuel hose on the port generator. LEGACY COMPONENT DESC: Hose
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2003
Resolved 19 February 2003
Communications › Alarms/Indicators
Issued 11 February 2003 Resolved
Provide placards for the general alarm contactors. LEGACY COMPONENT DESC: General Alarm
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 13 March 2003
Electrical › Electric Supply System (service)
Issued 11 February 2003 Resolved
Provide for the proper storage of the battaries locate in the 01 deck A/C space. The installation and storage shall be in compliance with 46 CFR 111.15. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 12 March 2003
Resolved 24 March 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 28 March 2002 Resolved
INSTALL PIPING EXTENSION ON PAINT LOCKER FIXED CO2 SYSTEM BRANCH LINE
Condition: Improper Installation
Due 28 March 2002
Resolved 28 March 2002
Resolution: DONE.
Engineering › Steering Gear System
Issued 28 March 2002 Resolved
INSTALL CHAFING GEAR ON PORT AND STBD "Z" DRIVE FLEXIBLE HOSES. LEGACY COMPONENT DESC: HOSES
Condition: Improper/Lack of Maintenance
Due 28 March 2002
Resolved 28 March 2002
Communications › Internal Communications System › Sound-powered Telephone
Issued 28 March 2002 Resolved
CORRECTLY REPAIR "Z" DRIVE ROOM TO OPERATE UNDER NORMAL AND EMERGENCY POWER.
Condition: Improper Installation
Due 28 March 2002
Resolved 28 March 2002
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 28 March 2002 Resolved
PROPERLY STORE ALL CHLORINE AND AMMONIA PRODUCT TO PREVENT ACCIDENTAL MIXING
Condition: Unknown
Due 28 March 2002
Resolved 28 March 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 March 2002 Resolved
REMOVE ALL EXTENSION CORDS SERVING AS PERMANENT WIRING.
Condition: Improper Installation
Due 28 March 2002
Resolved 28 March 2002
Fire Fighting › Structural - A Class Divisions
Issued 28 March 2002 Resolved
PROPERLY REPAIR EMERGENCY GENERATOR ROOM FIRE DAMPER LEGACY COMPONENT DESC: DAMPERS
Condition: Improper Installation
Due 28 March 2002
Resolved 28 March 2002
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 28 March 2002 Resolved
DEMONSTRATE PROPER OPERATION OF THE DEPTH SOUNDER
Condition: Improper/Lack of Maintenance
Due 28 March 2002
Resolved 28 March 2002

Casualty record · 2

11 August 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2775663
19 January 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3135439
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.