MAURY USCG vessel records
← All vessels

MM 41B

Built
1998
Last inspected
29 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 29 June 2026
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 28 calendar years (1998–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

470770
Flag
UNITED STATES
Maury page id
psix-470770

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE · ASHLAND CITY TN · built 1998
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 2 April 2026 · expires 30 April 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 49 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 7 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 49

29 June 2026 Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8416418
24 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8165302
8 July 2024 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7953436
4 May 2023 Deficiency Check · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7675942
28 March 2023 Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7655833
9 July 2022 Damage Survey
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7503406
18 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7453610
13 May 2021 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7197023
19 June 2020 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6984904
23 April 2020 Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6943459
22 February 2019 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6632635
5 March 2018 Special · Cargo Tank Internal · Examination of Repairs · Internal Structural Exam · COI Inspection · Administrative Inspection · MTSA Verification · Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6366025
20 April 2017 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6126993
15 June 2016 MTSA Verification · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5908143
26 February 2016 Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5821150
13 January 2016 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5795036
22 December 2015 Damage Survey · Permit to Proceed
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5787988
14 December 2015 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5782124
6 May 2015 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5118849
6 May 2014 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4850839
5 July 2013 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4644007
30 April 2012 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4296007
9 March 2010 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3693194
16 February 2010 COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3680426
29 April 2009 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3463779
21 April 2009 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3456529
5 January 2009 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3419797
25 February 2008 Administrative Inspection · Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3153133
30 January 2008 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3140155
3 May 2007 Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2920066
22 May 2006 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2656583
13 April 2005 MTSA Verification · Administrative Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2332848
14 March 2005 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2307588
16 February 2005 Administrative Inspection · COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2293953
3 June 2004 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2087448
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997373
4 April 2003 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1768454
17 March 2003 Internal Structural Exam · Periodic Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1758229
12 June 2002 Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1629964
17 May 2001 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 493552
5 February 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1452756
30 March 2000 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 756635
25 March 2000 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 203098
14 March 2000 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1393365
8 January 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 453844
21 December 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 474460
14 December 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 528539
21 May 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1413545
30 March 1998 Construction Oversight · Initial Certification · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1381194

Deficiency record · 22

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 8 July 2024 Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station, conspicuously marked, and located at the midpoint of such vessel, or 100 feet from the engine, whichever is the more practical. The remote quick acting manual shutdown shall be installed on the engine so as to provide a quick and effective means of stopping the engine (such as by cutting off the intake air). Remote shut down cable seized replace or repair to original condition and conduct test of the shut-off to the satisfaction of the Marine Inspector. 46CFR32.50-35(a)
Action required: 705 - Other - as specified
Resolved 8 July 2024
Resolution: Verified satisfactory test of the required shutdown, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 July 2024 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date, except as specified in paragraph (b) of this section. Vsl failed to conduct Annual inspection as required, conduct inspection prior to conducting commercial operations. 46CFR31.10-17(a)
Action required: 705 - Other - as specified
Resolved 8 July 2024
Resolution: Completed Annual Inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 March 2023 Resolved
Except as provided in paragraphs (b) through (g) of this section, each tank vessel must undergo drydock, internal structural, and cargo tank internal examinations as follows: Table 31.10-21 (b) Fresh water service internal structural exam for double hull with external framing on freshwater route every 5 years. Vessel requested to conduct ISE at a port where repairs could be made. Request made during renewal inspection on 29 March 2023, ISE due on 31 March 2023. Vessel cargo operations will be prohibited until an ISE is completed and any required repairs are made to the satisfaction of the attending MI. 46 CFR 31.10-21
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 May 2023
Resolved 4 May 2023
Resolution: ISE completed to satisfaction of MI.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 29 March 2023 Resolved
Operational tests and checks of all safety and limit control, combustion controls, programming controls and safety relief valves must be conducted by owner, chief engineer,or person in charge at the inspection for certification, periodic inspection and when directed by the OCMI. Vessel was unable to test the thermal fluid heater at renewal due to cargo in tanks. Vessel is restricted from using the thermal fluid heater until testing is completed to the satisfaction of the attending MI. 46 CFR 61.30-20
Action required: 10 - Deficiency Rectified
Due 4 May 2023
Resolved 4 May 2023
Resolution: Testing of thermal fluid heater conducted to satisfaction of MI.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 20 April 2017 Resolved
Improperly sized portable fire extinguisher prevented bracket from properly securing extinguisher and negated extinguisher's approval. Three portable extinguishers on board as required by COI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 20 April 2017
Resolution: Vessel operator replaced portable fire extinguisher with a properly sized extinguisher for mounting bracket.
Construction/Loadline › Penetrations › Gasket
Issued 20 April 2017 Resolved
Weather deck hatch for integrated/double bottom void missing gasket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 20 April 2017
Resolution: Gasket replaced by vessel rep.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 26 February 2016 Resolved
Transfer procedures failed to include product information for cargo (residue) currently on board as required by 33 CFR 155.720; 33 CFR 154.310.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 26 February 2016
Resolution: Appropriate product information placed on board.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 26 February 2016 Resolved
Switchboard located on weather deck used in thermal fluid heater system had several 1/8 inch holes in the box compromising container's construction integrity. Construction integrity required to be maintained IAW 46 CFR 111.01-1. Integrity of container to be restored prior to using equipment.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 26 February 2016
Resolution: Vessel rep properly restored construction integrity.
Engineering › Fuel Oil Service System › Valve, Control
Issued 26 February 2016 Resolved
Shut off valve in fuel supply line to generator at generator prime mover leaking fuel and fitting in fuel supply line to cargo pump prime mover IVO gauges leaking fuel. Diesel fuel supply systems required to meet 46 CFR Supchapter F.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 26 February 2016
Resolution: Valve packing and fitting tightened; properly securing leaks.
Construction/Loadline › Hull › Stiffener
Issued 1 January 2016 Resolved
Four cracks in deck that are temporarily repaired with epoxy and no less than four structural members in the bow that are bent or cracked. Vessel is on a PTP to offload and proceed to repairs. No further cargo operations are permitted.
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 13 January 2016
Resolution: Completed repairs to the satisfaction of attending USCG Marine Inspector.
Deck/Cargo › Cargo Heating › General
Issued 16 February 2010 Resolved
Properly conduct furnace internal inspection, NLT 22 Mar 10.
Condition: Improper/Lack of Maintenance
Due 22 March 2010
Resolved 9 March 2010
Resolution: Internal examination completed. No areas of concern noted.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 16 February 2010 Resolved
Properly replace gasket on the #3 port cargo tank hatch ullage.
Condition: Improper/Lack of Maintenance
Due 1 March 2010
Resolved 9 March 2010
Resolution: Verified new gasket
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 16 February 2010 Resolved
Properly replace vent pipe on the #3 port PV valve.
Condition: Improper/Lack of Maintenance
Due 1 March 2010
Resolved 9 March 2010
Resolution: New stainless steel vent pipe installed.
Deck/Cargo › Cargo Heating › General
Issued 16 February 2010 Resolved
Properly install insulation on the cargo pipe drain piping.
Condition: Improper/Lack of Maintenance
Due 1 March 2010
Resolved 9 March 2010
Resolution: Insulation wrap installed on drain pipe.
Construction/Loadline › Structures › Scuttle
Issued 21 April 2009 Resolved
Properly repair #4 port void hatch cover.
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 29 April 2009
Resolution: Repaired bracket on hatch with new weld.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 24 February 2005 Resolved
Repair ground detection on generator panel.
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 14 March 2005
Deck/Cargo › Cargo Heating › General
Issued 24 February 2005 Resolved
Repair or replace the dampner on fwd sight glass on heater.
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 14 March 2005
Deck/Cargo › Cargo Heating › General
Issued 24 February 2005 Resolved
Make thermal fluid heater ready for internal exam of refractory in St. Louis. While in transit and/or the heater is in operation stand proper watch to ensure heater caseing does not shoe signs of overheating.
Action required: 705 - Other - as specified
Resolved 25 February 2005
Resolution: We were looking at insulation on the coil tie down. The refractory does not need to be opened.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 17 March 2003 Resolved
Replace or renew flame screens in gooseneck vents and all cargo tank ullages. LEGACY COMPONENT DESC: Flame Screens
Condition: Improper/Lack of Maintenance
Due 17 April 2003
Resolved 20 March 2003
Deck/Cargo › Holds/Tanks
Issued 17 March 2003 Resolved
Repair valve position indicator on #3 stbd cargo tank valve. LEGACY COMPONENT DESC: Tank Level Monitoring Device
Condition: Unknown
Due 17 April 2003
Resolved 20 March 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 17 March 2003 Resolved
Properly shackle rigging of hoisting gear. LEGACY COMPONENT DESC: Hoisting Gear
Condition: Improper Installation
Due 17 April 2003
Resolved 20 March 2003
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 17 March 2003 Resolved
Vessel operator (charged party) failed to, on two occaisions, notify the cognizant OCMI of repairs to the vessel in accordance with 46 CFR 30.01-10.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 March 2003
Resolution: Repairs inspected, air tests witnessed, previously unreported repairs discovered and properly inspected.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.