Inspection history · 47
3 April 2026
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8341657
6 March 2026
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8314348
27 December 2025
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8287632
24 October 2025
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8258137
14 September 2025
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8233112
4 June 2025
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8151673
10 March 2025
COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8091362
26 November 2024
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8040320
12 October 2024
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8018188
20 September 2024
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8004847
25 March 2024
COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7882871
12 January 2024
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7848861
25 September 2023
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7796397
26 July 2023
Exemption · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7775290
20 May 2023
COC-CVE Quarterly · Ballast Water Examination · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7691528
17 March 2023
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7652457
16 October 2022
PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7577242
5 October 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7572990
11 April 2022
COC-CVE Quarterly · Ballast Water Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7427268
10 March 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7409969
8 November 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7347225
16 October 2021
PSC A · In-Service Inspection · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7332356
6 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935899
2 October 2019
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6832019
30 September 2019
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6824173
28 March 2019
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6673623
26 March 2019
COC-CVE Quarterly · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6649747
31 January 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6617825
7 November 2018
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6577491
4 October 2018
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6550481
11 April 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6389622
14 March 2018
Ballast Water Examination · Deficiency Check · COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6370398
30 December 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6370969
6 December 2017
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6321126
2 October 2017
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6278114
4 April 2017
COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6117537
17 March 2017
Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6106436
10 January 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6068579
20 December 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6060532
4 December 2016
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6052500
16 November 2016
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6042061
2 October 2016
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6013035
10 May 2016
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5873629
10 April 2016
Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5850169
5 April 2016
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5847854
22 February 2016
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5819727
24 January 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5805061
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 March 2026
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed port side rescue boat with intermittent gear lever engagement when selecting
forward gear.
74 SOLAS 20 III/20.2
action code 17c
def code 11129
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 10 March 2026
Resolved 6 March 2026
Resolution: Crew troubleshot and identified loose throttle cable connection. Rectified and retested sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 March 2026
Resolved
The construction of all doors and door frames in ``A'' class
divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. PSCO observed 12 fire doors, including those in main vertical zone boundaries stairway enclosures, unable to close properly.
74 SOLAS 97 II-2/30.2
Action code 17c
Def Code 07105
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 10 March 2026
Resolved 6 March 2026
Resolution: Crew rectified each identified door prior to completion of exam
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 March 2026
Resolved
Each power-operated sliding watertight door, shall be
provided with an audible alarm, distinct from any other alarm
in the area, which will sound whenever the door is closed
remotely by power and which shall sound for at least 5 s but nounit. PSCO observed approximatley half of the sliding watertight doors in machinery spaces with inoperable visual signals
74 SOLAS 04 II-1/15.7.1.6
Action Code 16c
Def code 03107
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 6 March 2026
Resolution: Crew replaced bulbs and retetested
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 March 2026
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed several lifeboats with emergency steering tillers incapable of steering the lifeboat to starboard.
74 SOLAS 20 III/20.2
Action code 50c
Def code 11129
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2026
Resolved 15 March 2026
Resolution: Class report attesting to satisfactory resolution provided, uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 March 2026
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed A/C machinery space on deck 7 converted into workshop, including storage of combustibles.
74 SOLAS 97 II-2/26.2.2
action code 50c
def code 07101
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2026
Resolved 6 March 2026
Resolution: Crew removed all items stowed in A/C machinery space prior to completion of exam.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 March 2026
Resolved
Fire-fighting systems and appliances shall be kept in good
working order and readily available for immediate use.
Portable extinguishers which have been discharged shall
be immediately recharged or replaced with an equivalent
unit. PSCO observed stowed items blocking sprinkler
system nozzles on aft mooring deck.
74 SOLAS 20 II-2/14.2.1.2
action code 16c
def code 07123
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2026
Resolved 6 March 2026
Resolution: Crew removed stowed gear prior to completion of exam.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 March 2026
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed several technical spaces behind linings being used for storage, including combustibles.
74 SOLAS 97 II-2/26.2.2
action code 16c
def code 0701
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2026
Resolved 6 March 2026
Resolution: Crew removed items prior to completion of exam.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 March 2026
Resolved
Means of control shall be provided for opening and closure of skylights, closure of openings in funnels which normally allow exhaust ventilation, and closure of ventilation dampers. PSCO observed ventilation dampers 9304 and 04301 not close when activated.
74 SOLAS 97 II-2/11.4.1
action code 16c
def code 07114
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2026
Resolved 6 March 2026
Resolution: Crew troubleshot and demonstrated satisfactory operation of dampers prior to completion of exam.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 March 2026
Resolved
Doorways, cooridors, and intermediate landings included in means of escape shall be sized in the same
manner as stairways. PSCO observed secondary means of
escape door form category one observation center was
smaller than 800 millimeters.
74 SOLAS 97 II-2/28.1.5.3
action code 50c
def code 07120
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2026
Resolved 15 March 2026
Resolution: Class report attesting to satisfactory resolution provided, uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 March 2026
Resolved
Means of control shall be provided for opening and closure of skylights, closure of openings in funnels which normally
allow exhaust ventilation, and closure of ventilator dampers.
PSCO observed labelling for fire damper control system to be inaccurate.
74 SOLAS 97 II-2/11.4.1
action code 50c
def code 07114
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2026
Resolved 6 March 2026
Resolution: Crew corrected inaccurate labelling on damper. System remains inaccurate, however NCOE stated that this was acceptable.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 September 2025
Resolved
07105 Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing. PSCO observed Firedoor# 03/3/02, 4-2-05, and 3.6.20 not able to close. 74 SOLAS 97 II-2/30.4.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 September 2025
Resolved 14 September 2025
Resolution: Doors were restored to proper fucntionality and operation.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 September 2025
Resolved
07120 In addition to the emergency lighting, the means of escape, including stairways and exits, shall be marked by lighting of photoluminescent strip indicators placed not more than 0.3m (300mm) above the deck at all points of the escape route including angles and intersections. The marking must enable passengers to identify all the routes of escape and readily identify escape exits. Escape route located in Luminere restaurant had escape route signage that was not visible. 74 SOLAS 97 II-2/28.1.10 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 September 2025
Resolved 14 September 2025
Resolution: Signage was installed above the escape route.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 12 October 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. PSCOs were informed that Diesel Generator #3 had a governor malfunction, causing the diesel generator to be non-operational.
74 SOLAS (20) Ch I / Reg 11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2024
Resolved 26 November 2024
Resolution: Vessel submitted documenation showing Diesel Generator #3 and to find it in good working order.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 September 2024
Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, all openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted.
FSD 01/3/03 and 03/7/14 failed to securely latch upon closing.
74SOLAS97 II-2/30.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 September 2024
Resolved 20 September 2024
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 16 October 2022
Resolved
Means of escape shall be marked by lighting or photoluminescent strip indicators placed...at all points of the escape route, including angles and intersections. Secondary exit leading from Fathoms lacks low location lighting.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2022
Resolved 14 November 2022
Resolution: LLL was installed and documentation to support submitted.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 October 2022
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Crew unfamiliar with operation of liferaft davit. Davit was entended to the degree that wire rope was causing limit switch to be activated preventing raft from being lifted into embarkation position. Additionally, crew did not arrange the liferaft in an postition suitable for embarkation.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 16 October 2022
Fire Fighting › Means of Escape › Escape Route Signs
Issued 14 March 2018
Resolved
0915 - signs indications - Additional aids for escape shall be provided as necessary to ensure accessibility, clear marking, and adequate design for emergency situations. Signage in numerous locations throughout the ship are missing and others are not in accordance with the fire control plan. - 74SOLAS(2014 cons.)II-2/13.1.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 28 March 2018
Resolution: Vessel submitted class report attesting to the correction of def. Vessel installed and replaced exit and emergency exit signage throughout the ship IAW the fire control plan.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 6 December 2017
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2018
Resolved 1 February 2018
Resolution: USCG Issued NOV
Fire Fighting › Structural - A Class Divisions › Aux Spaces (little/no fire risk)
Issued 2 October 2017
Resolved
A category 10 space is a space where the storage of combustibles is prohibited. Port and starboard fan rooms FWD Deck 6 (space 6.6) had excessive air filters stored in there.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 October 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 March 2017
Resolved
The condition of the ship and its equipment shall be maintained to conform with the condition of the present regs. Vessel suffered a reduction of propulsion due to decrease of cooling liquid for port shaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 17 March 2017
Resolution: Received Class report from LR attesting to adequate repair of cooling piping. Def rectified.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 4 December 2016
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2016
Resolved 5 December 2016
Resolution: ISSUED NOV
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 April 2016
Resolved
0750-Fire Prevention- The construction of all doors in "A" class divisions with the means of serving shall provide resistance to fire. Fire door 11/02/01 needs to be replaced due to it's inoperability and fire screen door 3/04/05 is not capable of full closure at the bottom. SOLAS 74 (97 con.) chap II-2 Reg 30 (2).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 10 May 2016
Resolution: MSD Port Canaveral received Class Report from Lloyd's Register surveyor attesting to repair and satisfactory operation of both Fire Screen Doors.
Fire Fighting › Structural - A Class Divisions › Special Category Spaces
Issued 10 April 2016
Resolved
0750-Fire Prevention- The minimum fire fire integrity of bulkheads shall be as prescribed in the table 26.1 A-0 bulkhead on deck deck 11 between 1Ft space & pyrotechnics space does not meet A-0 requirements due to new ventilation trunk with no damper. SOLAS 74 (97 Con Ed.) Chap.II-2 Reg 26.1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 10 May 2016
Resolution: MSD Port Canaveral received Class Report from Lloyd's Register surveyor stating that ventilation fan and associated trunking have been removed and A-0 bulkhead integrity reinstated to the Surveyor's satisfaction.