Records from 2004 to 2025. Most recent: inspection, 29 May 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)130.9 ft × 36.0 ft × 11.5 ft
Registered tonnagegross 90 / net 50
ITC dimensions (L × B × D)130.9 ft × 36.0 ft × 11.5 ft
ITC tonnagegross 443 / net 132
BuilderBOLLINGER SHIPYARDS INC · LOCKPORT, LA, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Regulatory (Subpart C or D), Net Ton
132 - Convention (Subpart B), Net Ton
551 - Dead Weight, Ton
90 - Regulatory (Subpart C or D), Gross Ton
443 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
20 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; 1 vessel inspected with it, by name and date; 1 other recorded name, with years; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 20
29 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8147598
12 June 2024
Cargo Tank Internal · Drydock Exam · COI Inspection · MTSA Verification · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7933180
7 September 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7787248
8 September 2022
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7554471
4 August 2022
Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7524907
4 August 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7534450
15 September 2021
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7311963
12 May 2021
Internal Structural Exam · Drydock Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7194992
8 June 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6971340
1 August 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6775963
14 June 2019
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6711940
16 May 2019
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6685648
22 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6359605
25 September 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6275606
8 June 2017
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 6169857
19 April 2017
In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6128463
5 January 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6066340
11 July 2016
Administrative Inspection · COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5936567
29 June 2016
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5924006
10 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5903493
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 August 2022
Resolved
Each vessel must have a main and an independent auxiliary means of steering. Vessel reported a total loss of steering due to an electrical issue. Vessel must troubleshoot and makes repairs to steering and electrical systems to satisfaction of CG Marine Inspector.
46 CFR 130.130(b)
60c
Action required: 60 - Rectify deficiencies prior to movement
Due 4 August 2022
Resolved 8 August 2022
Resolution: Received tech report of repairs / testing.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 14 June 2019
Resolved
Rudder angle indicator’s at the forward operating station was off by approximately 10 degree. Make the rudder angle indicator’s align.
Action required: 10 - Deficiency Rectified
Resolved 14 June 2019
Resolution: Angle indicator's corrected and aligned.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 June 2019
Resolved
Navigation Light screens were painted green and not mat black.
Action required: 10 - Deficiency Rectified
Resolved 14 June 2019
Resolution: Navigation light screens painted mat black.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 June 2019
Resolved
Public address system is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2019
Resolved 17 June 2019
Resolution: PA system worked satisfactory to MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 June 2019
Resolved
Emergency lighting in emergency escape route from engine room to the main deck was inoperable.
Action required: 10 - Deficiency Rectified
Due 14 June 2019
Resolved 14 June 2019
Resolution: Emergency light operable.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 June 2019
Resolved
Watertight door from passage way leading to the engine room requires adjusting to make it watertight. The dogs were not properly seating.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: Watertight door properly adjusted to maintain watertight integrity.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 June 2019
Resolved
Port shaft packing gland has a small continuous stream of water leaking out.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: Shaft leak secured and is no longer leaking.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 14 June 2019
Resolved
Emergency steering procedures not posted in Engine Room or Operating Station.
Action required: 10 - Deficiency Rectified
Resolved 14 June 2019
Resolution: Posted emergency steering procedures used to transfer steering in the Operating Station and Engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 June 2019
Resolved
Fire Monitor had exposed rotating machinery on the aft end of the pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: Machinery guard properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 June 2019
Resolved
Liquid mud pump machinery guard was wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: Machinery Guard properly installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2019
Resolved
Transfer procedures in the engine room only had the line diagram and not the actual procedures.
Action required: 10 - Deficiency Rectified
Due 14 June 2019
Resolved 14 June 2019
Resolution: Transfer procedures with line diagram in the engine room where the transfer takes place were posted.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 June 2019
Resolved
Valve handles were missing on the ballast system and waste oil system.
Action required: 10 - Deficiency Rectified
Resolved 14 June 2019
Resolution: Installed valve handles for both missing valves.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2019
Resolved
Valves on the ballast, waste oil discharge and fuel transfer system were not labeled.
Action required: 10 - Deficiency Rectified
Resolved 14 June 2019
Resolution: Valves were correctly labeled.
Construction/Loadline › Structures › Door
Issued 25 September 2017
Resolved
The following WTD found not watertight. Forward engine room, port engine room, galley to bowthruster, and the WTH from the engine room to deck.
Condition: Improper/Lack of Maintenance
Due 26 October 2017
Resolved 26 September 2017
Resolution: Made watertight as ABS report.
Electrical › Electrical Distribution System (service) › Cable
Issued 25 September 2017
Resolved
Electrical Rox Block connection at the engine room fwd WTD and the stuffing tube by the port WTD not watertight.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2017
Resolved 26 September 2017
Resolution: Fittings made watertight per ABS report.
Engineering › Fuel Oil Service System › Filter
Issued 25 September 2017
Resolved
Fuel strainers on port main engine and bow thruster do not meet ASTM 1201.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2017
Resolved 26 September 2017
Resolution: Replaced fuel strainers with the correct equipment.
Engineering › Pressure Vessel › Pressure Gauge
Issued 25 September 2017
Resolved
Face plate on port air receiver gauge cracked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 October 2017
Resolved 26 September 2017
Resolution: Gauge replaced.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 25 September 2017
Resolved
Lagging on port main engine missing a section.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2017
Resolved 26 September 2017
Construction/Loadline › Hull › Weld
Issued 19 April 2017
Resolved
Deck cut to allow for machinery space repairs. USCG was not notified prior to cutting. Certified welders required to complete repairs & NDT required to the satisfaction of attending USCG Inspector prior to departure.
Action required: 705 - Other - as specified
Resolved 20 April 2017
Resolution: Repairs completed & tested with no additional actions needed.
Engineering › Steering Gear System › Pump
Issued 11 July 2016
Resolved
Show proper operation of No. 2 steering pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2016
Resolved 12 July 2016
Resolution: New Solenoid was installed on No.2 steering pump
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 July 2016
Resolved
Replace E-light by STBD life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2016
Resolved 12 July 2016
Resolution: New E-light was installed.
Engineering › Fuel Oil Service System › Valve
Issued 11 July 2016
Resolved
Secure fuel leak on port generator fuel line.
Due 11 July 2016
Resolved 11 July 2016