Records from 2006 to 2026. Most recent: inspection, 14 May 2026.
Documentation record
Registered dimensions (L × B × D)144.0 ft × 36.0 ft × 12.0 ft
Registered tonnagegross 86 / net 59
ITC dimensions (L × B × D)144.0 ft × 36.0 ft × 12.0 ft
ITC tonnagegross 486 / net 145
BuilderMASTER BOAR BUILDERS INC · CODEN, AL, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGOLDEN MEADOW, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it486 - Convention (Subpart B), Gross Ton
86 - Regulatory (Subpart C or D), Gross Ton
145 - Convention (Subpart B), Net Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
14 May 2026
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8373315
3 April 2026
Deficiency Check · Drydock Exam · Administrative Inspection · Vessel Attendance · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8309281
15 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8136868
22 April 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7899777
13 February 2024
COI Inspection · Drydock Extension · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7864945
3 January 2023
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7616915
4 August 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7534450
9 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7446591
3 March 2021
Hull Examination · Deficiency Check · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7149237
2 June 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6965942
27 September 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6841286
6 February 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6621967
29 January 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6616546
18 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6483847
8 June 2018
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6438264
14 November 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6306386
11 July 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6205188
9 May 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6142113
11 April 2017
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6128492
1 March 2016
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5824503
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 February 2024
Resolved
A vessel of less than 100 gross tons must have adequate emergency lighting fitted along the line of escape to the main deck from accommodations and working (machinery) spaces below the main deck. Emergency escape leading from engine room to main deck was inoperable. 46 CFR 129.440(a).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 February 2024
Resolution: Lights were repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 February 2024
Resolved
Each penetration of, and each opening in, a bulkhead in a machinery space must have means to make it watertight.
46 CFR 174.195 (b)(2).
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 February 2024
Resolution: Thru hull penetration for rudder angle indicator rod was made watertight.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 May 2022
Resolved
Rudder angle indicator did not move past 20 degrees. Rudder angle inidcator must accurately reflect the position of the rudder for safety of navigation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2022
Resolved 3 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 May 2022
Resolved
Engine control monitor was unhinged and being held in place by a bungee chord. This equipment must be fastened securely to the engine as designed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2022
Resolved 3 June 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 March 2021
Resolved
Each Class 1 watertight door must be watertight. Class 1 watertight door from passageway to engine room had worn hinge pins and would not seal making it not watertight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2021
Resolved 12 March 2021
Resolution: Brass pins and gasket replaced and chalk test conducted.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 January 2019
Resolved
Emergency lighting at embarkation station is not installed. Vessel must provide emergency lighting at primary life saving equipment stowage and embarkation locations.
46 CFR 112.15-1(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2019
Resolved 18 February 2019
Resolution: Installed lighting in all required areas. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2019
Resolved
Starboard air reciever missing pressure gauge. Vessel must install pressure gauge with range 1.2 to 2 times the MAWP of the air system.
46 CFR 54.15-5
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2019
Resolved 18 February 2019
Resolution: gage installed, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 January 2019
Resolved
Navigation lights were inoperable. The Primary Masthead light and Stern primary and secondary lights need to be replaced before vessel conducts nightime operations.
33CFR83.22
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2019
Resolved 18 February 2019
Resolution: Installed new lights where required, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 29 January 2019
Resolved
Vessel auto-pilot system only operates for a single rudder not for both rudders as designed. Vessel also has an inappropriate system in place (ziptie and pencil) to ensure auto pilot remains running. Vessel must replace broken parts and ensure auto pilot system operaters per the manufacture instructions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2019
Resolved 18 February 2019
Resolution: Manufacturer serviced auto pilot, all sat.
Engineering › Fuel Oil Service System › Filter
Issued 8 June 2018
Resolved
Provide repairs to fuel system (filters)
Action required: 10 - Deficiency Rectified
Due 8 June 2018
Resolved 8 June 2018
Resolution: Rebuilt fuel fiters on both MDE's
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 8 June 2018
Resolved
Provide repairs to propulsion engine E-stops.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2018
Resolution: Replaced Solenoids for E-stops
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 9 May 2017
Resolved
Tailshafts will need to be pulled at next dry dock because vsl is now in "I" service at next dry dock as per 46CFR61.20-17(b)
Action required: 705 - Other - as specified
Due 7 February 2019
Resolved 13 July 2018
Resolution: Vsl is no longer multi cert, on L service as of 13JUL2018.
Construction/Loadline › Hull › Transverse Frame
Issued 9 May 2017
Resolved
C/R Wasted frame under firepump at next dry dock.
Action required: 705 - Other - as specified
Due 7 February 2019
Resolved 13 July 2018
Resolution: Will be resolved at next dry dock.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 9 May 2017
Resolved
Ground Indicators on switchboard had burnt out bulbs.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 11 May 2017
Engineering › Pressure Vessel › Relief Valve
Issued 9 May 2017
Resolved
Relief Valves were not mounted on body of air recievers.
Due 17 May 2017
Resolved 11 May 2017
Lifesaving › Line-Throwing Appliances › Lines
Issued 9 May 2017
Resolved
Vsl did not have 500 ft aux line.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 11 May 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 March 2016
Resolved
Drills not logged properly.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 March 2016
Construction/Loadline › Structures › Door
Issued 1 March 2016
Resolved
Demonstrate watertight integrity of engine room forward WTD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2016
Resolution: Readjusted door.
Navigation › Piloting/Steering › Marine Charts
Issued 1 March 2016
Resolved
Provide up to date charts.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2016
Resolution: New charts.