MAURY USCG vessel records
← All vessels

SERGEANT

Built
1998
Last inspected
5 August 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 5 August 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 17 calendar years (1999–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP5405
472577
Flag
UNITED STATES
Maury page id
psix-472577

Documentation record

Registered dimensions (L × B × D)65.0 ft × 22.0 ft × 8.5 ft
Registered tonnagegross 81 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRODRIGUEZ BOAT BUILDERS · CODEN, AL, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHOUMA, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 18 April 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Simplified, Net Ton
81 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LINDY LOU Towing Vessel · MISLE 143297 · 18 November 2014 · activity 5026270WILLIAM BREWSTER Towing Vessel · MISLE 213895 · 18 November 2014 · activity 5026270MORGAN RAY Towing Vessel · MISLE 1100244 · 18 November 2014 · activity 5026270USL 459 Tank Barge · MISLE 40846 · 26 April 2012 · activity 4296791

Inspection history · 21

5 August 2026 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8456150
2 July 2026 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8431610
27 March 2025 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8093751
11 June 2024 Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7932346
6 March 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7646010
24 January 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7384534
2 June 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7213537
26 November 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7102361
12 March 2020 Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6924889
27 August 2015 Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5231083
18 November 2014 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5026270
26 April 2012 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4296791
19 February 2010 MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3682521
26 October 2009 Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3621734
22 June 2006 MTSA Verification · Uninspected Other
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2688989
15 April 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2044825
2 August 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 292873
14 December 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 770240
11 December 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 210752
8 March 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 79237
26 January 1999 Uninspected Towing Vessel
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 789492

Deficiency record · 20

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 June 2024 Resolved
Fuel shutoff valve must stop flow of fuel supplying directly to propulsion engine or generator prime move. Fuel shutoff valve did not operate properly to stop fuel flow.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 21 June 2024
Resolution: Operator demonstrated proper operation of fuel shutoff valve.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 June 2024 Resolved
The vessel's name and hailing port must be marked on the exterior part of the stern of the vessel. Vessel's name and hailing port was not marked on the exterior of the stern.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 21 June 2024
Resolution: Operator provided satisfactory evidence of vsl's name and hailing port installation on stern of vsl.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 24 January 2022 Resolved
"Electrical systems and equipment must function properly and minimize system failures." VHF radio was not operational on emergency power. VHF shall be operational on emergency power.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 January 2022
Resolved 24 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 January 2022 Resolved
Each liferaft must be stowed at a height above the waterline not greater than the maximum stowage height indicated on the container. The IBA was stowed above the height indicated on the placard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2021 Resolved
Every towing vessel of 7.8 meters (26 feet) or over in length, must have a Bridge-to-Bridge Act document issued to the vessel. Vessel does not have a Bridge-to-Bridge Act document. 47 CFR 80.1001(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 14 June 2021
Resolution: Received photo evidence of issued Bridge-to-Bridge Act Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 June 2021 Resolved
Each towing vessel operating on coastwise route must have a means to take blood pressure readings. Vessel does not have a means to take blood pressure readings. 46 CFR 140.435
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 14 June 2021
Resolution: Received photo evidence of blood pressure monitor on board the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2020 Resolved
(a) Each cable and wire on a towing vessel must be installed to meet the following requirements: (b) Extension cords must not be used as a permanent connection to a source of electrical power. The vessel had several cords daisy chained and various extension cords. Remove cords and plug in to an electrical outlet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 20 March 2020
Resolution: Extension cords were removed from crew accommodations and electrical panel in the bridge was wired to fixed outlet.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 March 2020 Resolved
(e) Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 12 March 2020
Resolution: Valves were labeled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 March 2020 Resolved
Paint locker must have a 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b) of this part.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 12 March 2020
Resolution: 40-B portable extinguisher was fixed to paint locker.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 March 2020 Resolved
An existing vessel must have in the engine room i) An approved 160-B semi-portable fire-extinguishing system to protect the engine room. The CO2 ext. was not of 160 B size. Install new ext. of proper size.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 12 March 2020
Resolution: Vessel purchased and installed new 160B semi-portable extinguisher.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 March 2020 Resolved
(1) Each detector, control panel, remote indicator panel, and fire alarm are approved by the Commandant under approval series 161.002 or listed by a NRTL as set forth in 29 CFR 1910.7; the pull station was not permanently installed. Crew installed screws prior to departure.
Action required: 10 - Deficiency Rectified
Due 12 March 2020
Resolved 12 March 2020
Resolution: Crew reinstalled panel cover.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 March 2020 Resolved
(a) Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The generator fuel hoses were dry rotted and unserviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 20 March 2020
Resolution: New fuel hoses were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 March 2020 Resolved
(b) Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. The port MDE was missing the exhaust lagging. Replace lagging to ensure there is no potential of someone getting burned.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 20 March 2020
Resolution: Lagging was added to exhaust piping.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 12 March 2020 Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. With (b) Additional equipment. The line throwing appliance must have: (2) An auxiliary line that: (i) Is at least 450 meters (1,500 feet) long; (ii) Has a breaking strength of at least 40 kilonewtons (9,000 pounds-force); and (iii) Is, if synthetic, of a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 19 March 2020
Resolution: Vessel purchased line throwing device and auxillary line.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 March 2020 Resolved
(e) The vessel, including crew's quarters and the galley, must be kept in a sanitary condition. Vessel's fidley door allowed exhaust to contaminate crew spaces. Regasket door to prevent exhaust from entering crew spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 20 March 2020
Resolution: Fidley door was regasketed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 12 March 2020 Resolved
(a) Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention located at each operating station. Install and test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 20 March 2020
Resolution: Alarms were installed and tested.
Documentation › Certificates/Documents › FCC SSL
Issued 22 June 2006 Resolved
Vessel operator did not possess a radio operator permit.
Due 22 July 2006
Resolved 19 February 2010
Resolution: Captain had radio operator permit.
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 2 August 2001 Resolved
OFFICIAL NUMBER OF VESSEL NOT CLEARLY VISIBLE/ PRESENT ON INTERIOR HULL.
Condition: Unknown
Due 2 September 2001
Resolved 22 June 2006
Documentation › Certificates/Documents › FCC SSL
Issued 2 August 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 2 September 2001
Resolved 22 June 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 August 2001 Resolved
VESSEL MISSING CURRENT TIDE TABLES, LIGHT LIST, NOTICE OF MARINERS, COAST PILOT, AND INLAND NAVIGATION RULES.
Condition: Unknown
Due 2 September 2001
Resolved 22 June 2006

Recorded names · 1

HELEN (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.