Inspection history · 21
5 August 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8456150
2 July 2026
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8431610
27 March 2025
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8093751
11 June 2024
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7932346
6 March 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7646010
24 January 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7384534
2 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7213537
26 November 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7102361
12 March 2020
Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6924889
27 August 2015
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5231083
18 November 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5026270
26 April 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4296791
19 February 2010
MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3682521
26 October 2009
Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3621734
22 June 2006
MTSA Verification · Uninspected Other
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2688989
15 April 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2044825
2 August 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 292873
14 December 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 770240
11 December 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 210752
8 March 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 79237
26 January 1999
Uninspected Towing Vessel
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 789492
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 June 2024
Resolved
Fuel shutoff valve must stop flow of fuel supplying directly to propulsion engine or generator prime move. Fuel shutoff valve did not operate properly to stop fuel flow.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 21 June 2024
Resolution: Operator demonstrated proper operation of fuel shutoff valve.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 June 2024
Resolved
The vessel's name and hailing port must be marked on the exterior part of the stern of the vessel. Vessel's name and hailing port was not marked on the exterior of the stern.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 21 June 2024
Resolution: Operator provided satisfactory evidence of vsl's name and hailing port installation on stern of vsl.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 24 January 2022
Resolved
"Electrical systems and equipment must function properly and minimize system failures." VHF radio was not operational on emergency power. VHF shall be operational on emergency power.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 January 2022
Resolved 24 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 January 2022
Resolved
Each liferaft must be stowed at a height above the waterline not greater than the maximum stowage height indicated on the container. The IBA was stowed above the height indicated on the placard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2021
Resolved
Every towing vessel of 7.8 meters (26 feet) or over in length, must have a Bridge-to-Bridge Act document issued to the vessel. Vessel does not have a Bridge-to-Bridge Act document.
47 CFR 80.1001(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 14 June 2021
Resolution: Received photo evidence of issued Bridge-to-Bridge Act Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 June 2021
Resolved
Each towing vessel operating on coastwise route must have a means to take blood pressure readings. Vessel does not have a means to take blood pressure readings.
46 CFR 140.435
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 14 June 2021
Resolution: Received photo evidence of blood pressure monitor on board the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2020
Resolved
(a) Each cable and wire on a towing vessel must be installed to meet the following requirements:
(b) Extension cords must not be used as a permanent connection to a source of electrical power.
The vessel had several cords daisy chained and various extension cords. Remove cords and plug in to an electrical outlet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 20 March 2020
Resolution: Extension cords were removed from crew accommodations and electrical panel in the bridge was wired to fixed outlet.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 March 2020
Resolved
(e) Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 12 March 2020
Resolution: Valves were labeled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 March 2020
Resolved
Paint locker must have a 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b) of this part.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 12 March 2020
Resolution: 40-B portable extinguisher was fixed to paint locker.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 March 2020
Resolved
An existing vessel must have in the engine room i) An approved 160-B semi-portable fire-extinguishing system to protect the engine room. The CO2 ext. was not of 160 B size. Install new ext. of proper size.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2020
Resolved 12 March 2020
Resolution: Vessel purchased and installed new 160B semi-portable extinguisher.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 March 2020
Resolved
(1) Each detector, control panel, remote indicator panel, and fire alarm are approved by the Commandant under approval series 161.002 or listed by a NRTL as set forth in 29 CFR 1910.7; the pull station was not permanently installed. Crew installed screws prior to departure.
Action required: 10 - Deficiency Rectified
Due 12 March 2020
Resolved 12 March 2020
Resolution: Crew reinstalled panel cover.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 March 2020
Resolved
(a) Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The generator fuel hoses were dry rotted and unserviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 20 March 2020
Resolution: New fuel hoses were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 March 2020
Resolved
(b) Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. The port MDE was missing the exhaust lagging. Replace lagging to ensure there is no potential of someone getting burned.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 20 March 2020
Resolution: Lagging was added to exhaust piping.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 12 March 2020
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. With (b) Additional equipment. The line throwing appliance must have: (2) An auxiliary line that:
(i) Is at least 450 meters (1,500 feet) long;
(ii) Has a breaking strength of at least 40 kilonewtons (9,000 pounds-force); and
(iii) Is, if synthetic, of a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 19 March 2020
Resolution: Vessel purchased line throwing device and auxillary line.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 March 2020
Resolved
(e) The vessel, including crew's quarters and the galley, must be kept in a sanitary condition. Vessel's fidley door allowed exhaust to contaminate crew spaces. Regasket door to prevent exhaust from entering crew spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 20 March 2020
Resolution: Fidley door was regasketed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 12 March 2020
Resolved
(a) Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention located at each operating station. Install and test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 20 March 2020
Resolution: Alarms were installed and tested.
Documentation › Certificates/Documents › FCC SSL
Issued 22 June 2006
Resolved
Vessel operator did not possess a radio operator permit.
Due 22 July 2006
Resolved 19 February 2010
Resolution: Captain had radio operator permit.
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 2 August 2001
Resolved
OFFICIAL NUMBER OF VESSEL NOT CLEARLY VISIBLE/ PRESENT ON INTERIOR HULL.
Condition: Unknown
Due 2 September 2001
Resolved 22 June 2006
Documentation › Certificates/Documents › FCC SSL
Issued 2 August 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 2 September 2001
Resolved 22 June 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 August 2001
Resolved
VESSEL MISSING CURRENT TIDE TABLES, LIGHT LIST, NOTICE OF MARINERS, COAST PILOT, AND INLAND NAVIGATION RULES.
Condition: Unknown
Due 2 September 2001
Resolved 22 June 2006