17 July 2025
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8188276
23 October 2024
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8023305
30 July 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7969472
2 November 2023
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7819523
26 November 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7666561
9 November 2022
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7590816
1 August 2022
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7522482
2 July 2022
Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7511926
9 December 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7379076
17 November 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7352667
30 April 2021
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7186678
17 August 2020
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7035167
30 July 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7020102
8 May 2014
Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4853389
5 June 2008
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3228317
20 November 2007
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3101622
10 November 2007
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3096663
10 November 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3097636
5 June 2007
Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2951973
20 September 2006
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2782801
16 September 2006
Permit to Proceed · Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2780130
8 August 2006
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2793646
30 May 2006
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2608448
27 May 2004
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2054442
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977683
14 July 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1845856
29 May 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1787209
24 July 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1840905
28 May 2002
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1614406
23 August 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 769360
14 August 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 208565
29 May 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428032
18 May 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453757
28 May 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462758
15 April 1999
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1123340
26 March 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 180273
23 July 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 127582
28 May 1998
Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458541
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 August 2025
Resolved
An interconnected detection and alarm system must: Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d). Vessel did not have visual/audible in accommodations(crew) and no visual in Gen Room. Due to Maritime Safety Solutions inventory and techs, vsl is on list to have system complete inline w/ rest of fleet. Provide proof when completed.
46 CFR 181.450(a)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 21 August 2025
Resolution: Vessel rep (Wade) provided video evidence of corrective actions. See narrative..
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 23 October 2024
Resolved
Vessel required to be able to recover a helpless person from the water to OCMI satisfaction. Rescue platform does not meet OCMI standards. Platform was 24 in X 28 in. not the required 36 in x 36 in.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 7 November 2024
Resolution: New platform meeting the requirements.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 23 October 2024
Resolved
Vessels operating more than 100 miles required to have NAVTEX. Vessel not equipped with NAVTEX, Restricted to no more than 100 miles until installed. 47 CFR 80.905(a)(3)(v)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 7 November 2024
Resolution: NAVTEX installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 October 2024
Resolved
Installed fire systems shall be labeled and have instructions posted. Remote stations for the fixed CO2 system for generator and Main machinery space labeling or instructions posted. Crew was not sure of the purpose or operation of the remote stations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 7 November 2024
Resolution: Instructions and labels posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2024
Resolved
Each battery must be secured from shifting. Battery for port generator doesn't fit in securing bracket and was not secured.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 7 November 2024
Resolution: Battery secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 November 2023
Resolved
Exhaust gas must not leak from piping or any connections.
Port Generator had a pinhole exhaust leak in the exhaust piping into the ER.
46 CFR 182.430(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2023
Resolution: Cleared via pictures provided by vessel rep.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 November 2023
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Bulkhead at the FWD engine room compartment & bulkhead between ER and generator space had multiple empty bulkhead penetration fittings as light was seen penetrating.
46 CFR 179.320(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2023
Resolution: Cleared by pictures provided by vessel rep.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 November 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
Starboard generator crankshaft drive belt is exposed.
46 CFR 177.960
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 11 December 2023
Resolution: Vessel rep texted photo to MI clearing Def.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 2 November 2023
Resolved
Each vessel must be marked as required by part 67. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel.
Hailing port on the stern of the vessel (Morgan City) did not match the COI and COD (New Orleans).
46 CFR 185.602
46 CFR 67.123
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 11 December 2023
Resolution: Vessel rep texted photo to MI clearing def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 November 2023
Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage.
All MDE primary fuel filters had non-metallic bowls and did not have a flame shields.
46 CFR 182.455(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 6 December 2023
Resolution: Vessel rep texted MI photo clearing deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 November 2023
Resolved
Exhaust system protection must be provided at such locations where persons or equipment might come in contact with an exhaust pipe.
MDE #4 had missing exhaust lagging.
46 CFR 182.430(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 6 December 2023
Resolution: Vessel rectified via photo texted to MI.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 November 2023
Resolved
A vessel must comply with the requirements for any radio installations, including the requirements for a station license and installation certificates issued by the FCC, in 47 CFR part 80. 705- Limited to <20NM from land.
Vessel did not have a MF, SSB, and NAVTEX.
46 CFR 184.502
Action required: 705 - Other - as specified
Resolved 2 November 2023
Resolution: Cleared by photo provided by vessel rep.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 November 2023
Resolved
Fire detection must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas. Accommodation spaces and bridge did not have interconnected fire detection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 12 June 2024
Resolution: Received invoice for fire detection system.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 November 2023
Resolved
A vessel must comply with the requirements for any radio installations, including the requirements for a station license and installation certificates issued by the FCC, in 47 CFR part 80. Vessels Radio Station Certificate call sign did not match the Radio Safety Telephony & Bridge-to-Bridge certificate, and EPIRB registration.
46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 11 December 2023
Resolution: Vessel rep texted photo to MI clearing Def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 November 2023
Resolved
Each distribution panel and switchboard must protected from falling debris and dripping or splashing water.
Distribution panel front access door IVO starboard generator will not close.
46 CFR 183.330
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 11 December 2023
Resolution: Vessel rep texted photo to MI clearing Def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 November 2023
Resolved
All machinery and equipment must be installed to provide protection from causing a fire, explosion, machinery failure, and personnel injury.
Inboard port MDE has excessive corrosion on the wet exhaust connection.
Complete prior to dry dock credit.
46 CFR 182.100
Action required: 705 - Other - as specified
Resolved 9 August 2024
Resolution: Wet exhaust sections repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 November 2023
Resolved
Spanner wrenches must be provided where a 1.5" diameter firehose is required.
Spanner missing from hose station next to fire pump.
46 CFR 181.310
Action required: 10 - Deficiency Rectified
Resolved 2 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 November 2023
Resolved
All machinery and equipment must be installed to provide protection from causing a fire, explosion, machinery failure, and personnel injury.
Starboard generator injection pump delivery pipes were leaking diesel. Both generators had a pooling mixture of oil/diesel and oil soaked rags.
46 CFR 182.100
Action required: 10 - Deficiency Rectified
Resolved 2 November 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 November 2023
Resolved
At each inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: all smoke and fire detection systems.
The fire detection panel was exhibiting a fault in Zone 1, engine room.
46 CFR 176.810
Action required: 10 - Deficiency Rectified
Resolved 2 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 November 2023
Resolved
All machinery and equipment must be installed to provide protection from causing a fire, explosion, machinery failure, and personnel injury.
MDE #3 shaft seal was leaking an excessive amount of water.
46 CFR 181.200
Action required: 10 - Deficiency Rectified
Resolved 2 November 2023
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 November 2023
Resolved
A vessel must comply with the requirements for any radio installations, including the requirements for a station license and installation certificates issued by the FCC, in 47 CFR part 80.
Master had a Restricted Radio Operator Permit and the mate did not have Marine Radio Operator Permit on-board.
46 CFR 184.502
Action required: 10 - Deficiency Rectified
Resolved 2 November 2023
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 November 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. A temp repair was found on STBD stern hull plate, Repair to approved proposal. Repair approximate 1/4" hole in engine room exhaust duct. 46 CFR 177.100.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2023
Resolution: Resolved during vessel annual inspection on 02NOV2023.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 November 2022
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck. Add lighting to aft engine room to properly illuminate aft door. 46 CFR 183.432.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2023
Resolution: Resolved during vessel annual inspection on 02NOV2023.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2022
Resolved
Batteries must be secured to protect against shifting with the roll and pitch of the vessel and must be mounted in trays lined with, or constructed of, a material that is resistant to damage by the electrolyte. Properly secure generator batteries. 46 CFR 183.350.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2023
Resolution: Resolved during vessel annual inspection on 02NOV2023.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2022
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Repair power distribution panel door in generator room. 46 CFR 183.330 (b).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2023
Resolution: Resolved during vessel annual inspection on 02NOV2023.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 November 2022
Resolved
All safety and relief valves for use on pressure vessels or piping systems shall be designed to meet the protection and service requirements for which they are intended and shall be set to relieve at a pressure which does not exceed the “maximum allowable working pressure” of the pressure vessel. Unable to verify relief valve setting due to corrosion on tags. 46 CFR 182.330, 46 CFR 54.15-10 (a).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2023
Resolution: Cleared by annual inspection on 02NOV2023
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 17 November 2021
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. During inspection of the hull exterior, the MI observed the following cracks to hull welds: 19” crack on stbd to stern hull weld, 16”x.5” crack at stern to main deck hull weld and a 9”x1/4” crack at main deck to port quarter side shell hull weld. Crack to stern main deck weld showed light penetrating into steering compartment. Crew stated they were unaware of hull damage. Identification of hazardous situation, in combination with the additional deficiencies identified during the inspection shows objective evidence that a serious substandard condition of the vessel is not being proactively managed onboard.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 18 November 2021
Resolution: Vessel made necessary repairs to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 17 November 2021
Resolved
After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's…stability letter...The vessel may not depart until it is in compliance with these requirements. The vessel master was unaware of how to complete loading calculations as required by vessels stability letter. Additionally, vessel did not have onboard the ability to determine weight of under deck cargo/fuel/ballast to assist in making this determination. Company shall provide master with necessary training and tools to efficiently calculate safe loading conditions prior to departure.
Action required: 30 - Ship detained
Resolved 18 November 2021
Resolution: Vessel proved capability to perform stability calculations as per stability letter to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 17 November 2021
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties. Each fire drill must include: Instruction in the use and location of fire alarms, extinguishers, and any other fire fighting equipment on board. When questioning the deckhand on previous training and knowledge for operating the vessels fixed CO2 system, the deckhand had not received instruction nor had knowledge of the operation of the system. Vessel shall ensure all crewmembers are familiar with operating the fixed CO2 system prior to departure.
Action required: 30 - Ship detained
Resolved 17 November 2021
Resolution: Company personnel performed training to crew on operation of fixed CO2 system.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 November 2021
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Main engines exhausts had numerous excessive leaks inside engine room. Excessive amounts of soot was observed by the MI throughout the entire engine room. Vessel corrected all leaks prior to arrival however, vessel shall proactively manage leaks to ensure hazardous gases do not accumulate inside enclosed spaces.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2021
Resolution: Marine inspector verified through operation of all four main diesel engines that no further exhaust leaks exist.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 November 2021
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems…Approximately 6” of oily water mixture was identified in the engine room bilges. Vessel shall remove oil from bilge prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2021
Resolution: Vessel cleaned bilges to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 November 2021
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Vessel has several 12V wires in engine room overhead with excessive deterioration to outer sheathing. Company electrician made temporary repairs using electrical tape however, permanent repairs shall be carried out at vessels next drydock.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2021
Resolution: Company electrician wrapped deteriorated wiring with electrical tape. Special note added to ensure permanent repairs are conducted at next drydock.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 November 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Charts onboard vessel had not been corrected or updated with the most recent local notice to mariners. Additionally electronic chart system onboard had not been updated since March, 2021. Vessel could not provide a copy of the latest notice to mariners. Vessel shall ensure charts used onboard are updated for intended voyage prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2021
Resolution: Vessel updated paper and electronic charts to the satisfaction of the attending MI.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 November 2021
Resolved
Each EPIRB…must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test…shall be logged or otherwise documented, as applicable. No records of the monthly EPIRB tests could be presented to the MI. Vessel shall ensure monthly tests are performed and logged prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2021
Resolution: Master tested and properly logged monthly EPIRB test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 November 2021
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets...Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18.) Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square. Personal flotation devices were stored under seating without any markings notifying passengers of storage location in the event of emergency use. Vessel shall apply appropriate markings within 30 days.
Personal flotation devices were stored under seating without any markings notifying passengers of storage location in the event of emergency use. Vessel shall apply proper markings within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 December 2021
Resolution: Vessel provided documentary evidence of life jacket stowage markings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 November 2021
Resolved
Where pressure-indicating gages are used, they shall be chosen to be compatible with the pressure to be indicated. The size of the visual display, the fineness of graduations, and the orientation of the display will be considered. In no case shall the upper range of the gage be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. Pressure gauge on starboard outboard air receiver was unreadable. Pressure gauge seal was missing and fluid inside gauge filled with soot from exhaust leaks, making the gauge unreadable. Vessel shall replace gauge within 30 days to ensure proper indication of pressure can be verified.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 November 2021
Resolution: Vessel replaced pressure gauge to the satisfaction of the attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 17 August 2020
Resolved
Any vessel of at least Five net tonswhich engages in Coastwise trade must have a Certificate of Documentation with a valid endorsement.
Vessel underwent a name change from CANDY MAKER to GOL MAKER and is awaiting an updated Certificate of Documentation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2020
Resolved 10 September 2020
Resolution: Name change complete.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 August 2020
Resolved
On a vessel of more than 65 feet in length, each hose must conform to UL19.
02 Fire hoses ruptured while under pressure. Hoses were destroyed and two new hoses were purchased.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 August 2020
Resolved 17 August 2020
Resolution: Vessel destroyed damaged hoses, and purchased two new hoses and brought them onboard, prior to the completion of the inspection.
Construction/Loadline › Hull › Weld
Issued 8 May 2014
Resolved
Crack weld and cracked overboard exhaust from the port generator. Required vsl to replace exhaust pipe and cut an 18" x 18" insert in the hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2014
Construction/Loadline › Structures › Scuttle
Issued 8 May 2014
Resolved
Emergency passenger door has missing striker plate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2014
Construction/Loadline › Penetrations › Weld
Issued 8 May 2014
Resolved
Thru bulkhead collar below fwd berthing area had cracked welds.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2014
Construction/Loadline › Penetrations › Weld
Issued 8 May 2014
Resolved
thru bulk head collar stbd wing void in aft berthing area has a cracked weld around. Required to replace
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2014
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 8 May 2014
Resolved
Replace section of deteriorated R/W pipe at AC condenser
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2014
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 8 May 2014
Resolved
Replace damaged/worn lagging around exhaust pipes from generators.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2014
Electrical › Electrical Distribution System (service) › Cable
Issued 10 November 2007
Resolved
Electrician is to survey electrical damage caused by fire to engine room.
Action required: 705 - Other - as specified
Resolved 15 November 2007
Resolution: Electrical repairs have been corrected.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 10 November 2007
Resolved
Severe damage to port side longitudinal beams forward and adjacent to #1 engine. Crop and renew.
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Cropped and renewed.
Construction/Loadline › Hull › Side Shell
Issued 16 September 2006
Resolved
(02) punctures of p/s day tank, each 1' below deck level, approx 2" x 3". (01) puncture of p/s main fuel cargo tank, fwd of p/s day tank. Est. approx 1' below deck level, approx 4" x 4".
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2006
Resolution: Repairs complete.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 September 2006
Resolved
Fuel oil transfer line wasted/ holed. Est holing < 1/16". Significant wastage of approx 20' of fuel oil line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2006
Resolved 17 September 2006
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 16 September 2006
Resolved
Approx 200 - 300 g of waste oil and fresh diesel in bilges.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2006
Resolved 17 September 2006
Fire Fighting › Fire Main › Condition
Issued 16 September 2006
Resolved
Approx 2' section of fire main requires replacement due to corrosion. Fuel oil txfer line corroded to firemain 1' fwd of p/s main fuel cargo tank.
Action required: 705 - Other - as specified
Due 18 September 2006
Resolved 17 September 2006
Lifesaving › Buoyant Apparatus
Issued 29 May 2003
Resolved
Paddles not lashed down to lifefloat. LEGACY COMPONENT DESC: Paddles
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2003
Resolution: Paddles lashed down.
Engineering › Lubricating Oil Storage/Transfer System
Issued 29 May 2003
Resolved
Sightglass in E/R made of plastic. LEGACY COMPONENT DESC: Sightglass
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2003
Resolution: Sightglass replaced with glass.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 29 May 2003
Resolved
One light inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2003
Resolution: Light replaced.