MAURY USCG vessel records
← All vessels

JACOB C

JACOB C is a 1981 offshore supply vessel. The Coast Guard has recorded 20 inspections since 2016, most recently in May 2024, along with 17 deficiencies and 2 casualty investigations between 2019 and 2022.

Records from 2016 to 2024. Most recent: inspection, 6 May 2024.

Built
1981
Last inspected
6 May 2024
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDD9436
Flag
UNITED STATES
Maury page id
psix-52927

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded3
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)98.8 ft × 26.0 ft × 7.5 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOLLIER SHIPBUILDING INC. · BAYOU LA BATRE, AL, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GOL MAKER Passenger (Inspected) · MISLE 472818 · 2 July 2022 · activity 7511926

Inspection history · 20

6 May 2024 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7908187
23 April 2024 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7899954
13 March 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7878221
17 July 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7745148
28 July 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7518387
12 July 2022 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7504411
3 July 2022 Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7494476
2 July 2022 Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7511926
28 April 2021 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7184524
14 April 2021 Hull Examination · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7174920
16 July 2020 Annual Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6983723
8 September 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6807514
15 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6663002
29 March 2019 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6663798
3 July 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6477717
28 October 2017 Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 6297246
24 March 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6114960
27 July 2016 Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5955982
28 April 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5864215
20 April 2016 Administrative Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5858679

Deficiency record · 17

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 March 2024 Resolved
Repairs or alterations to the hull that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except for an emergency. Vessel had a temporary repair patch to the overhead above the Port Main Diesel Engine. Vessel must conduct permanent repair at next drydock inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 May 2024
Resolution: Vessel surrendered their COI and is no longer subject to 46 CFR Subchapter T
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 March 2024 Resolved
Repairs or alterations to the hull that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except for an emergency. Vessel had a broken weld on the Starboard Main Diesel Engine Exhaust support. Vessel must conduct permanent repair at next drydock inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 May 2024
Resolution: Vessel surrendered their COI and is no longer subject to 46 CFR Subchapter T
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 July 2023 Resolved
Each Class 1 Watertight door on a vessel in Oceans Service must be watertight. Main Engine Room door has hole in the bottom of the door.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2023
Resolved 19 July 2023
Resolution: Vsl rep provided proof of repaired door.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 3 July 2022 Resolved
Whenever any vessel is to be drydocked or hauled out in compliance with 176.15-1, or to carry out major repairs or alterations affecting the safety or seaworthiness of the vessel, it shall be the duty of the person in charge of the vessel, the owner, or the agent to report the same, together with the nature of any repairs, as far in advance as practicable to the Officer in Charge, Marine Inspection (OCMI), in order that an examination may be made by a marine inspector. Vessel has a 1/8" wide x 3" long crack in the Stbd #2 fuel running tank. Vessel is to transit daylight hours only directly to Sea Craft Shipyard in Amelia, LA to effect permanent repairs. Upon arrival, vessel is to contact MSU Morgan City Command Duty Officer at [phone withheld]. 46 CFR 176.15-10(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2022
Resolved 11 July 2022
Resolution: Repairs were made, and NDT was witnessed SAT.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 28 April 2021 Resolved
Inspection shall be in accordance with the standards acceptable to the OCMI as good marine practice. OCMI to examine all accessible parts of the exterior and interior of the hull, watertight bulkheads, and weather deck. After entering first watertight door from weather deck to engine room, identified wastage where longitudinal and vertical frame meet. Identified two broken welds above port engine, above horizontal exhaust pipe. 46 CFR 176.25-1(a) 46 CFR 176.25-5 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 May 2021
Resolved 28 April 2021
Resolution: Welds rewelded and frame cropped and renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 April 2021 Resolved
Each vessel in an ocean service must have an approved Class A EPIRB stowed in a manner that so that it will float free if the vessel sinks. EPIRB was found stowed under cover which prevented EPIRB from being float free. 46 CFR 180.40-1 (a) (3) Old-T
Action required: 10 - Deficiency Rectified
Due 28 April 2021
Resolved 28 April 2021
Resolution: EPIRB was moved to an unobstructed area outside of bridge to allow free float capability.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 April 2021 Resolved
Adequate emergency lighting automatically actuated upon failure of main lighting system shall be fitted along the line of escape. Emergency lighting near escape hatch from engine space was inoperable. 46 CFR 184.30-5 (a) Old-T
Action required: 10 - Deficiency Rectified
Due 28 April 2021
Resolved 28 April 2021
Resolution: Emergency light at escape hatch was replaced with a new one.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 April 2019 Resolved
Forepeak scuttle is missing bolt and pin.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2019
Resolution: VSL rep has forwarded photograph of sealed forepeak scuttle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 April 2019 Resolved
Port SSDG has oil leak on oil pan.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 April 2019
Resolution: VSL Rep has forwarded photograph of fixed L/O Leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 April 2019 Resolved
Exhaust lagging is missing around both MDE turbo chargers and metallic flex joints.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 April 2019
Resolution: VSL Rep has forwarded photograph of installed exhaust lagging.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 15 April 2019 Resolved
Public address system is inoperative.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2019
Resolution: VSL provided photographic and video evidence of an operational public address system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 April 2019 Resolved
Fuel Oil Shutoff is missing valve on STBD SSDG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2019
Resolution: VSL provided photographic evidence of a new installed F/O valve.
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 28 April 2016 Resolved
The closing device on the watertight door going into the E/R was broken.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: crew extended locking device and door closed properly
Fire Fighting › Means of Escape › Doorways
Issued 28 April 2016 Resolved
Emergency escape hatch did not latch closed
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: crew made repairs to the escape hatch and it sealed properly
Engineering › Pressure Vessel › Relief Valve
Issued 28 April 2016 Resolved
Remove reducers on relief valve
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Crew moved the relief valve to a different port without any reducers.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 April 2016 Resolved
Label and repair clusre device on electrical panel in E/R
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Electrical panel was repaired
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 28 April 2016 Resolved
Receptacle box on port main deck was wasted.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: New outlet box was installed and sealed.

Casualty record · 2

8 September 2019Major Marine Casualty · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · activity 6807514
2 July 2022Routine · role: Involved in a Marine Casualty · activity 7511926
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.