Inspection record

Last inspected 16 April 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE4003
Flag
UNITED STATES
Maury page id
psix-47321

Documentation record

Registered dimensions (L × B × D)63.2 ft × 28.0 ft × 7.3 ft
Registered tonnagegross 99 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMPBELL INDUSTRIES · SAN DIEGO, CA, UNITED STATES · built 1972
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GREAT WHITE Passenger (Inspected) · MISLE 359364 · 7 July 2017 · activity 6205976

Inspection history · 28

16 April 2026 Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8350968
21 April 2025 Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8119800
3 April 2025 Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8104293
22 January 2024 Internal Structural Exam · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7852746
7 September 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7787417
9 August 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7770019
1 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7710077
24 April 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7674760
6 January 2023 Examination of Repairs · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7617758
30 March 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7421617
15 December 2021 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7369460
27 May 2021 Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7208768
22 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7179550
15 April 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6939678
1 April 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6934258
29 April 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6673012
18 March 2019 Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6644948
9 March 2019 Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6639483
9 March 2019 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 6639668
9 March 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6660877
1 March 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6634992
30 January 2019 Administrative Inspection · DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6618110
1 May 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6403620
30 March 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6382230
16 October 2017 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6289055
7 July 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6205976
19 April 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6132535
2 May 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5923110

Deficiency record · 43

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2026 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Starboard side fixed bilge piping in way of MDE requires elbow replacement for small leak. 46CFR182.25-1(a) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2026
Resolved 8 May 2026
Resolution: Bilge piping repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 April 2026 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Require renewal. Oil seal on generator water pump leaking oil and fuel hose on generator wasted. Both require renewal. 46CFR182.10-1(a) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2026
Resolved 8 May 2026
Resolution: water pump repaired
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 April 2026 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol swabs installed on board during inspection are expired. Provide new alcohol swabs. 46 CFR 4.06-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2026
Resolution: Alcohol swabs renewed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 April 2026 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Anchor light inoperable. Provide navigation lights that are in compliance with the Navigation Rules. Vessel restricted to operations only during daylight hours until light renewed. 46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2026
Resolved 8 May 2026
Resolution: All around light repaired
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2025 Resolved
A vessel exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years... Vessel is not scheduled to complete their drydock examination until 09 June, exceeding the allowable timeline for completion of a drydock examination. Complete credit drydock to the satisfaction of the attending marine inspector. 46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2025
Resolution: Credit Drydock given following satisfactory completion of sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 April 2025 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Starboard side fixed bilge system non-operational. 46CFR182.25-1(a) "Old T"
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2025
Resolution: Motor for starboard fixed bilge pump renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2025 Resolved
Main propulsion machinery installed on each vessel is suitable for the vessel and its operation. Port and starboard turbo vent lines wasted. Require renewal. 46CFR182.01-(a) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2025
Resolved 20 May 2025
Resolution: Port and starboard turbo vent hoses replaced
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 22 January 2024 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. Course on aft portion of the railing has separated from post. Weld course back into place. 46 CFR 177.900(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2024
Resolved 2 February 2024
Resolution: Damaged course was welded and repaired properly.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 January 2024 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Stearn light lense housing unit was cracked. Provide navigation lights that are in compliance with the Navigation Rules. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2024
Resolved 28 February 2024
Resolution: Corrected with a new stern light installation.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 June 2023 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. Fire pump discharge pressure at gauge reading 35 psi. Vessel restricted to not more than 49 passengers and required to carry three 2 1/2 gallon fire buckets until the fire pump discharge pressure at the pump outlet is witnessed to be 60 psi or greater by the attending MI. 46 CFR 181.10-1(c) Old T
Action required: 705 - Other - as specified
Resolved 28 June 2023
Resolution: Fire pump operational at 60 PSI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 March 2022 Resolved
Child size life jackets must be equal to at least 10% of the number of persons permitted on board. Vessel missing 01 child life jacket. Provide 01 child life jacket. Reduction of passenger by 01 and child by 01. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 4 April 2022
Resolution: Child life jacket provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
Protect passengers and crew from electrical hazard. Extension cord being used at operating station above helm. Remove extension cord. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Extension cord removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
Protect passengers and crew from electrical hazard. String lighting system from bow to house to stern showing severe wear, conductor wasted and outer sleeve deteriorated. Replace wiring system. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Wiring replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
Protect passengers and crew from electrical hazard. Dead end wire located in stbd side crash void. Remove wire. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Wire removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
Equipment must be installed and maintained to provide services necessary. Winch and associated wiring on board but not in use. Remove system if not in use and not maintained or make operational. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Winch removed.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 30 March 2022 Resolved
Watertight bulkhead must be of sufficient strength to be capable of remaining watertight. Bulkhead forward of port side head showing severe corrosion/deterioration. Make repairs to bulkhead. 46 CFR 179.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 4 April 2022
Resolution: Bulkhead repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
Protect passengers and crew from electrical hazard. J-box cover missing from sewage pump in stbd tank space. Provide cover for J-box. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: J-box cover provided.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 30 March 2022 Resolved
Watertight bulkhead must be of sufficient strength to be capable of remaining watertight. Aft bulkhead stbd side tank space has filler where hole is. Remove filler and make appropriate permanent repairs to bulkhead. 46 CFR 179.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Permanent repairs to bulkhead made.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
Equipment must be installed and maintained to provide services necessary. Port fwd void light switch missing. Provide light switch. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Light switch provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2022 Resolved
Piping installed on each vessel must be suitable for the vessel and its operation. Port fwd void sink drain piping damaged/holed. Make repairs to piping or remove if system is not functioning. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 4 April 2022
Resolution: Piping replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 30 March 2022 Resolved
The construction and arrangement of a vessel must allow for safe operation of a vessel and seaworthy hull/deck. Port crash void showing 2 holes. Remove paint and temporary repairs(filler/calk/anything not aluminum)from deck and make ready for inspection. Holes also noted above Port ER generator. Repair all holes on deck. 46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Hole on deck repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2022 Resolved
Piping installed on each vessel must be suitable for the vessel and its operation. Port tank room fresh water leaking at aft bulkhead penetration. Make permanent repairs to piping and bulkhead. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Repairs made to piping and bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2022 Resolved
Where flexible nonmetallic hose is permitted for use in piping system it must meet SAE J-1942. Steering system hydraulic hoses at steering pump in engine room deteriorated. Replace hoses with J-1942 approved hose. 46 CFR 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Hydraulic hoses replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2022 Resolved
Piping installed on each vessel must be suitable for the vessel and its operation. Stbd engine room bilge prime pump pipe leaking. Make repairs to bilge pipe. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 4 April 2022
Resolution: Piping replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 March 2022 Resolved
Each inlet or pipe that penetrates the hull must have means to prevent water from entering. Port side engine below fire pump through hull room has temporary repair. Make permanent repair. 46 CFR 179.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Permanent repairs made to penetration.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
The owner/operator shall submit drawings describing any alterations. Proposed alterations must be approved. Over years numerous changes have been made to electrical system. Provide updated vessel AC/DC electrical plans. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: AC/DC drawing provided and submitted to MSC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2021 Resolved
Port side generator had oil soaked diapers surrounding generator. Generator has oil leak. Make proper repairs to limit fire danger and pollution threat from leaking generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Repair made to motor seal.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 April 2021 Resolved
High level bilge visual indicator not operational. Make bilge high level indicator operational at helm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Visual indicator operational.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 April 2021 Resolved
Stern light not operational. Make stern light operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Stern light operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Surge protector found under helm. Remove surge protector and hard wire new J-box if additional outlets needed. Provide updated electrical drawing if new J-box's/outlets installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: New wiring installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Under helm short extension cord with outlet on the end being used. Remove unapproved outlet and extension cord. If additional outlets needed provide updated electrical drawing of new J-box's/outlets installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Removed unapproved outlet extension cord.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Void spaces have physical lights but very few lights operational. Make all lights operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: New lights installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2021 Resolved
Engine room exhaust ventilation not operational. Make operational or remove system and electrical components. Provide updated electrical drawing once repaired or removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Removed engine room exhaust.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2021 Resolved
Port side transmission leaking fluid from dip stick during operational test. Troubleshoot and make appropriate repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 24 May 2021
Resolution: Reapirs made.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Port engine room has extension cord running to battery charger. Hard wire battery charger with appropriate over current protection and conductor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Hard wired battery charger.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Wooden battery box bottoms are wasted. Provide new battery box bottoms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: New battery box provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2021 Resolved
Gauge at fire pump outlet missing. Provide gauge for monitoring fire pump pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Gauge installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 March 2019 Resolved
Vessel struck submerged object causing top of port rudder to pierce hull in rudder room 15" x 2". Strut welds were cracked allowing water intrusion. Submit repair proposal to Sector Honolulu in accordance with 46 CFR 176.700. Repair prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2019
Resolution: Corrected by #6644948
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 March 2019 Resolved
Vessel struck submerged object damaging port shaft, strut bearing, and rudder. Submit repair proposal to Sector Honolulu in accordance with 46 CFR 176.700. Repair prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2019
Resolution: Cleared by #6644948.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 January 2019 Resolved
Watertight integrity requirements. Stbd collision bulkhead wire run was not closed. Make watertight in accordance with 46 CFR 179.310.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 March 2019
Resolution: Wire run sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 January 2019 Resolved
Material inspection of machinery. Jacket water hose to turbo on port and stbd main diesel engines were deteriorated. Renew hoses in accordance with 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 March 2019
Resolution: Hoses renewed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 May 2018 Resolved
11118-An adult life jacket must be provided for each person onboard. 09 life jackets failed inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 1 May 2018
Resolution: 09 adult life jackets were provided.
Engineering › Fuel Oil Service System › Piping
Issued 1 May 2018 Resolved
13101- Inspection of all fuel systems. High pressure fuel lines are not clamped properly stbd generator.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2018
Resolved 1 May 2018
Resolution: Clamps procured and installed.

Casualty record · 4

31 October 2013Routine · role: Involved in a Marine Casualty · activity 4745218
2 January 2014Routine · role: Involved in a Marine Casualty · activity 4777347
7 July 2017Routine · role: Transiting Vicinity of Primary Subject · activity 6205976
9 March 2019Routine · role: Involved in a Marine Casualty · activity 6660877
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.