MAURY USCG vessel records Sign in
← All vessels

KAULANA

KAULANA is a 1972 passenger vessel (inspected). The Coast Guard has recorded 124 inspections since 1985, most recently in April 2026, along with 242 deficiencies and 4 casualty investigations between 2013 and 2019.

Records from 1985 to 2026. Most recent: inspection, 16 April 2026.

Built
1972
Last inspected
16 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE4003
Flag
UNITED STATES
367347190
Maury page id
psix-47321

Inspections, by type

…with no type recorded24
Years with a record 38 calendar years (1985–2026)
The 124 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.2 ft × 28.0 ft × 7.3 ft
Registered tonnagegross 99 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMPBELL INDUSTRIES · SAN DIEGO, CA, UNITED STATES · built 1972
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE4003MMSI 367347190 · active · compulsorily equipped · granted 3 May 2018, expires 3 April 2028
WBR5131MMSI not assigned · expired · compulsorily equipped · granted 7 April 1998, cancelled 17 May 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GREAT WHITE Passenger (Inspected) · MISLE 359364 · 7 July 2017 · activity 6205976

Inspection history · 124

16 April 2026 Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8350968
21 April 2025 Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8119800
3 April 2025 Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8104293
22 January 2024 Internal Structural Exam · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7852746
7 September 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7787417
9 August 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7770019
1 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7710077
24 April 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7674760
6 January 2023 Examination of Repairs · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7617758
30 March 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7421617
15 December 2021 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7369460
27 May 2021 Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7208768
22 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7179550
15 April 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6939678
1 April 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6934258
29 April 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6673012
18 March 2019 Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6644948
9 March 2019 Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6639483
9 March 2019 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 6639668
9 March 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6660877
1 March 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6634992
30 January 2019 Administrative Inspection · DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6618110
1 May 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6403620
30 March 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6382230
16 October 2017 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6289055
7 July 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6205976
19 April 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6132535
2 May 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5923110
26 October 2015 Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5751152
3 July 2012 Plan Review "T" Boat
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4366707
21 January 2009 COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3397696
24 January 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3135639
31 October 2007 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3090686
26 October 2006 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2808689
17 May 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2652113
3 April 2006 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2616019
27 February 2006 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2592737
2 February 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2652061
15 October 2005 Hull Examination · Internal Structural Exam · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2515232
15 April 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2397169
9 March 2005 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 2308535
5 March 2005 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 2308505
17 November 2004 Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2243187
27 October 2004 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2229545
26 August 2004 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2177877
6 April 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2038616
14 January 2004 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1984981
6 January 2004 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1977078
31 October 2003 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1938349
1 October 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1919256
27 December 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1724333
18 November 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1707594
25 April 2002 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1609582
19 December 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1606007
2 November 2001 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362511
27 September 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1366569
6 August 2001 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1069114
6 August 2001 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1069151
18 July 2001 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1073086
23 October 2000 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1054679
3 March 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 815891
19 January 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1045959
13 December 1999 Re-Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378897
16 November 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1423282
3 November 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1386371
6 October 1998 Excursion Permit
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 801041
2 December 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 781427
4 November 1997 MARPOL Annex V Examination · Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1469159
18 April 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1107450
24 January 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1411407
2 May 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374594
5 April 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1078846
4 April 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1398438
12 March 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 886307
13 February 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 877721
4 January 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1380390
6 December 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367595
4 November 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396403
6 October 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1394377
28 February 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363205
30 November 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1387655
29 October 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 371984
2 March 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1405498
6 January 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1370760
26 November 1993 Deficiency Check · Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1473328
23 November 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 55043
3 November 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358210
12 October 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1403689
15 April 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1147254
6 April 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 838035
11 February 1993 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1143593
6 July 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 952474
6 March 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1316813
3 October 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1252743
9 April 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1228184
7 March 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1217221
24 July 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 914794
15 May 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 933394
11 April 1990 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 927600
29 December 1989 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 906324
13 November 1989 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1225861
19 June 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1349914
12 May 1989 Drydock Extension · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1031499
11 April 1989 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1035133
17 January 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1201074
26 October 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 896419
19 July 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1039781
13 April 1988 Deficiency Check · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1342650
16 December 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1313708
23 November 1987 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1334888
29 September 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1316864
29 June 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1319150
24 June 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1006471
11 June 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1310556
30 April 1987 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1327929
7 November 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1321510
27 June 1986 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1305858
6 May 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 990994
28 February 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1294424
29 May 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 983118
11 May 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 984211
19 April 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 983757
30 March 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 981757
19 March 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1291909

Deficiency record · 242

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2026 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Starboard side fixed bilge piping in way of MDE requires elbow replacement for small leak. 46CFR182.25-1(a) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2026
Resolved 8 May 2026
Resolution: Bilge piping repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 April 2026 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Require renewal. Oil seal on generator water pump leaking oil and fuel hose on generator wasted. Both require renewal. 46CFR182.10-1(a) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2026
Resolved 8 May 2026
Resolution: water pump repaired
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 April 2026 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol swabs installed on board during inspection are expired. Provide new alcohol swabs. 46 CFR 4.06-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2026
Resolution: Alcohol swabs renewed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 April 2026 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Anchor light inoperable. Provide navigation lights that are in compliance with the Navigation Rules. Vessel restricted to operations only during daylight hours until light renewed. 46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2026
Resolved 8 May 2026
Resolution: All around light repaired
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2025 Resolved
A vessel exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years... Vessel is not scheduled to complete their drydock examination until 09 June, exceeding the allowable timeline for completion of a drydock examination. Complete credit drydock to the satisfaction of the attending marine inspector. 46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2025
Resolution: Credit Drydock given following satisfactory completion of sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 April 2025 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Starboard side fixed bilge system non-operational. 46CFR182.25-1(a) "Old T"
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2025
Resolution: Motor for starboard fixed bilge pump renewed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2025 Resolved
Main propulsion machinery installed on each vessel is suitable for the vessel and its operation. Port and starboard turbo vent lines wasted. Require renewal. 46CFR182.01-(a) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2025
Resolved 20 May 2025
Resolution: Port and starboard turbo vent hoses replaced
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 22 January 2024 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. Course on aft portion of the railing has separated from post. Weld course back into place. 46 CFR 177.900(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2024
Resolved 2 February 2024
Resolution: Damaged course was welded and repaired properly.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 January 2024 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Stearn light lense housing unit was cracked. Provide navigation lights that are in compliance with the Navigation Rules. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2024
Resolved 28 February 2024
Resolution: Corrected with a new stern light installation.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 June 2023 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. Fire pump discharge pressure at gauge reading 35 psi. Vessel restricted to not more than 49 passengers and required to carry three 2 1/2 gallon fire buckets until the fire pump discharge pressure at the pump outlet is witnessed to be 60 psi or greater by the attending MI. 46 CFR 181.10-1(c) Old T
Action required: 705 - Other - as specified
Resolved 28 June 2023
Resolution: Fire pump operational at 60 PSI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 March 2022 Resolved
Child size life jackets must be equal to at least 10% of the number of persons permitted on board. Vessel missing 01 child life jacket. Provide 01 child life jacket. Reduction of passenger by 01 and child by 01. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 4 April 2022
Resolution: Child life jacket provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
Protect passengers and crew from electrical hazard. Extension cord being used at operating station above helm. Remove extension cord. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Extension cord removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
Protect passengers and crew from electrical hazard. String lighting system from bow to house to stern showing severe wear, conductor wasted and outer sleeve deteriorated. Replace wiring system. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Wiring replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
Protect passengers and crew from electrical hazard. Dead end wire located in stbd side crash void. Remove wire. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Wire removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
Equipment must be installed and maintained to provide services necessary. Winch and associated wiring on board but not in use. Remove system if not in use and not maintained or make operational. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Winch removed.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 30 March 2022 Resolved
Watertight bulkhead must be of sufficient strength to be capable of remaining watertight. Bulkhead forward of port side head showing severe corrosion/deterioration. Make repairs to bulkhead. 46 CFR 179.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 4 April 2022
Resolution: Bulkhead repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
Protect passengers and crew from electrical hazard. J-box cover missing from sewage pump in stbd tank space. Provide cover for J-box. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: J-box cover provided.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 30 March 2022 Resolved
Watertight bulkhead must be of sufficient strength to be capable of remaining watertight. Aft bulkhead stbd side tank space has filler where hole is. Remove filler and make appropriate permanent repairs to bulkhead. 46 CFR 179.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Permanent repairs to bulkhead made.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
Equipment must be installed and maintained to provide services necessary. Port fwd void light switch missing. Provide light switch. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Light switch provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2022 Resolved
Piping installed on each vessel must be suitable for the vessel and its operation. Port fwd void sink drain piping damaged/holed. Make repairs to piping or remove if system is not functioning. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 4 April 2022
Resolution: Piping replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 30 March 2022 Resolved
The construction and arrangement of a vessel must allow for safe operation of a vessel and seaworthy hull/deck. Port crash void showing 2 holes. Remove paint and temporary repairs(filler/calk/anything not aluminum)from deck and make ready for inspection. Holes also noted above Port ER generator. Repair all holes on deck. 46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Hole on deck repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2022 Resolved
Piping installed on each vessel must be suitable for the vessel and its operation. Port tank room fresh water leaking at aft bulkhead penetration. Make permanent repairs to piping and bulkhead. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Repairs made to piping and bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2022 Resolved
Where flexible nonmetallic hose is permitted for use in piping system it must meet SAE J-1942. Steering system hydraulic hoses at steering pump in engine room deteriorated. Replace hoses with J-1942 approved hose. 46 CFR 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Hydraulic hoses replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2022 Resolved
Piping installed on each vessel must be suitable for the vessel and its operation. Stbd engine room bilge prime pump pipe leaking. Make repairs to bilge pipe. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 4 April 2022
Resolution: Piping replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 March 2022 Resolved
Each inlet or pipe that penetrates the hull must have means to prevent water from entering. Port side engine below fire pump through hull room has temporary repair. Make permanent repair. 46 CFR 179.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Permanent repairs made to penetration.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022 Resolved
The owner/operator shall submit drawings describing any alterations. Proposed alterations must be approved. Over years numerous changes have been made to electrical system. Provide updated vessel AC/DC electrical plans. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: AC/DC drawing provided and submitted to MSC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2021 Resolved
Port side generator had oil soaked diapers surrounding generator. Generator has oil leak. Make proper repairs to limit fire danger and pollution threat from leaking generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Repair made to motor seal.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 April 2021 Resolved
High level bilge visual indicator not operational. Make bilge high level indicator operational at helm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Visual indicator operational.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 April 2021 Resolved
Stern light not operational. Make stern light operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Stern light operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Surge protector found under helm. Remove surge protector and hard wire new J-box if additional outlets needed. Provide updated electrical drawing if new J-box's/outlets installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: New wiring installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Under helm short extension cord with outlet on the end being used. Remove unapproved outlet and extension cord. If additional outlets needed provide updated electrical drawing of new J-box's/outlets installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Removed unapproved outlet extension cord.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Void spaces have physical lights but very few lights operational. Make all lights operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: New lights installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2021 Resolved
Engine room exhaust ventilation not operational. Make operational or remove system and electrical components. Provide updated electrical drawing once repaired or removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Removed engine room exhaust.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2021 Resolved
Port side transmission leaking fluid from dip stick during operational test. Troubleshoot and make appropriate repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 24 May 2021
Resolution: Reapirs made.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Port engine room has extension cord running to battery charger. Hard wire battery charger with appropriate over current protection and conductor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Hard wired battery charger.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2021 Resolved
Wooden battery box bottoms are wasted. Provide new battery box bottoms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: New battery box provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2021 Resolved
Gauge at fire pump outlet missing. Provide gauge for monitoring fire pump pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 20 May 2021
Resolution: Gauge installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 March 2019 Resolved
Vessel struck submerged object causing top of port rudder to pierce hull in rudder room 15" x 2". Strut welds were cracked allowing water intrusion. Submit repair proposal to Sector Honolulu in accordance with 46 CFR 176.700. Repair prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2019
Resolution: Corrected by #6644948
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 March 2019 Resolved
Vessel struck submerged object damaging port shaft, strut bearing, and rudder. Submit repair proposal to Sector Honolulu in accordance with 46 CFR 176.700. Repair prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2019
Resolution: Cleared by #6644948.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 January 2019 Resolved
Watertight integrity requirements. Stbd collision bulkhead wire run was not closed. Make watertight in accordance with 46 CFR 179.310.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 March 2019
Resolution: Wire run sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 January 2019 Resolved
Material inspection of machinery. Jacket water hose to turbo on port and stbd main diesel engines were deteriorated. Renew hoses in accordance with 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 March 2019
Resolution: Hoses renewed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 May 2018 Resolved
11118-An adult life jacket must be provided for each person onboard. 09 life jackets failed inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 1 May 2018
Resolution: 09 adult life jackets were provided.
Engineering › Fuel Oil Service System › Piping
Issued 1 May 2018 Resolved
13101- Inspection of all fuel systems. High pressure fuel lines are not clamped properly stbd generator.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2018
Resolved 1 May 2018
Resolution: Clamps procured and installed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 24 January 2008 Resolved
OUTDATED
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 January 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 January 2008 Resolved
OUTDATED MEDS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 January 2008
Electrical › Electric Generation Source (service) › Panelboard
Issued 24 January 2008 Resolved
PROVIDE OPERATIONAL GUAGES FOR STBD. SIDE GEN SET.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2008
Resolved 30 January 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 January 2008 Resolved
REPLACE ALL WIRE NUT CONNECTIONSON STBD SIDE GEN SET WITH PERMANENT CONNECTORS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2008
Resolved 24 February 2008
Engineering › Fuel Oil Service System › Vent Pipe
Issued 24 January 2008 Resolved
RENEW ALL SCREENS ON FUEL TANK VENTS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2008
Resolved 30 January 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 January 2008 Resolved
REPAIR BROKEN RAIL COURSE STBD. SIDE AFT GATE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 February 2008
Resolved 24 February 2008
Engineering › Bilge Water Management System › Pump
Issued 24 January 2008 Resolved
PROVIDE PORTABLE HAND PUMP
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 24 January 2008
Electrical › Electric Generation Source (service) › Panelboard
Issued 24 January 2008 Resolved
PROVIDE VOLT AND AMP METERS FOR BOTH GEN SETS.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 February 2008
Resolved 30 January 2008
Electrical › Electric Generation Source (service) › Generator
Issued 26 October 2006 Resolved
Prove generator battery charger installation. portable type battery charger is temp wired into the generator to charge the start batteries.
Due 26 November 2006
Resolved 24 November 2006
Stability › Severe Wind/Roll › General
Issued 26 October 2006 Resolved
Secure the cement block ballast in both aft steering gear compartments.
Due 24 November 2006
Resolved 24 November 2006
Engineering › Fuel Oil Service System › Filter
Issued 26 October 2006 Resolved
Put plugs in the bottom of all fuel strainers.
Due 24 November 2006
Resolved 24 November 2006
Construction/Loadline › Hull › Bracket
Issued 25 October 2005 Resolved
Remove unused frame/bracket located in center section of tank room on inboard side of STBD hull.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 November 2005
Resolved 22 November 2005
Construction/Loadline › Hull › Weld
Issued 25 October 2005 Resolved
Weld missing seam underside of main deck approx. six (6) inches forward of deckhouse on STBD side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 November 2005
Resolved 22 November 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 October 2005 Resolved
Provide lagging for exhaust and seal all leaks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2005
Resolved 22 November 2005
Engineering › Bilge Water Management System › Piping
Issued 15 October 2005 Resolved
Piping is rusted through on at least two section of the bilge system on the port and starboard side. Make repairs to the system and prove the system in the presence of a Coast Guard Marine inspector prior to movement of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 October 2005
Resolved 22 November 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 October 2005 Resolved
Shaft bent between the propeller and strut. Complete repairs or renew the shaft.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2005
Resolved 22 November 2005
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 15 October 2005 Resolved
The propeller edge has been sheered due to an allusion with a rock. Conduct repairs or renew to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 22 November 2005
Engineering › Steering Gear System › Rudder
Issued 15 October 2005 Resolved
The rudder is sheered in the aft portion of the rudder and on the bottom of the rudder. Conduct repairs or renew to its original condition.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 22 November 2005
Operations/Management › Vessel Traffic Service › Sailing Plan
Issued 15 October 2005 Resolved
Submit a transit plan for moving the vessel from Lahaina Harbor to dyrdock. Plan must include any modifications that need to be made to the vessel for transiting purposes, communication schedule while transiting, weather condition for when the transit will take place, and vessel assist information.
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 22 November 2005
Engineering › Generator (propulsion/auxiliary-electric) › Interlock Circuitry
Issued 27 October 2004 Resolved
Prove Generators.
Due 5 November 2004
Resolved 5 November 2004
Engineering › Fuel Oil Service System › Valve
Issued 27 October 2004 Resolved
Provide shields for emergency fuel shutoff valves.
Due 1 December 2004
Resolved 27 October 2004
Documentation › Certificates/Documents › FCC SSL
Issued 27 October 2004 Resolved
Provide fcc radio station licience.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2004
Resolved 1 November 2004
Communications › Radio Communications › EPIRB
Issued 27 October 2004 Resolved
Prove EPIRB hydro.
Due 1 November 2004
Resolved 1 November 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 October 2004 Resolved
Provide retro and vessels name on lifefloats.
Due 1 November 2004
Resolved 1 November 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 October 2004 Resolved
Cover open blank holes on switchboard in pilothouse.
Due 1 November 2004
Resolved 1 November 2004
Documentation › Logs/Records › Drug Test Records
Issued 27 October 2004 Resolved
Complete drug audit.
Due 1 November 2004
Resolved 1 November 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 October 2004 Resolved
Prove nav lights.
Due 1 November 2004
Resolved 1 November 2004
Documentation › Logs/Records › Logbook (official)
Issued 27 October 2004 Resolved
Provide lifesaving maintenance records.
Due 1 November 2004
Resolved 1 November 2004
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 27 October 2004 Resolved
Prove fire pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2004
Resolved 1 November 2004
Electrical › Electric Generation Source (service) › Generator
Issued 27 October 2004 Resolved
Prove generators.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2004
Resolved 1 November 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 October 2004 Resolved
Prove batteries for all life floats.
Due 1 November 2004
Resolved 1 November 2004
Lifesaving › Lifefloat › Paddle
Issued 27 October 2004 Resolved
Provide paddles for life floats.
Due 1 November 2004
Resolved 1 November 2004
Lifesaving › Lifefloat › Float-free Link
Issued 27 October 2004 Resolved
Prove lifefloat installation.
Due 1 November 2004
Resolved 1 November 2004
Construction/Loadline › Hull
Issued 6 January 2004 Resolved
Complete hull survey with CG Marine Inspector to verify seaworthiness of vessel. Prior to carrying passengers. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 6 January 2004
Resolved 9 March 2004
Engineering › Steering Gear System
Issued 6 January 2004 Resolved
Inspect shaft, props and rudders for damage. Prove proper operation of systems prior to carrying passengers. LEGACY COMPONENT DESC: Rudder
Condition: Damaged By Earlier Event
Due 6 January 2004
Resolved 9 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 18 November 2002 Resolved
Install chainlink fencing, wire mesh, etc. IAW 46CFR177.900. LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Due 2 December 2002
Resolved 27 December 2002
Lifesaving › Buoyant Apparatus
Issued 18 November 2002 Resolved
Replace batteries for waterlights IAW 46CFR185.726(d). LEGACY COMPONENT DESC: light
Condition: Improper/Lack of Maintenance
Due 2 December 2002
Resolved 27 December 2002
Electrical › Electrical Distribution System (service)
Issued 18 November 2002 Resolved
Repair or properly remove dead end wires located at operating station. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 2 December 2002
Resolved 27 December 2002
Electrical › Electrical Distribution System (service)
Issued 18 November 2002 Resolved
Properly isolate panel from liquor locker IAW 46CFR183.330. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Due 2 December 2002
Resolved 27 December 2002
Fire Fighting › Fire Main
Issued 18 November 2002 Resolved
Properly repair fractures in firemain IAW 46CFR181.310. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Due 2 December 2002
Resolved 27 December 2002
Engineering › Fuel Oil Service System › Valve
Issued 18 November 2002 Resolved
Properly repair fuel shut off valve located in port engine room.
Condition: Unknown
Due 18 November 2002
Resolved 18 November 2002
Engineering
Issued 2 November 2001 Resolved
Two soft patches noted on starboard MDE exhaust piping. Effect permanent repair IAW 46CFR182.430 NLT 16NOV01.
Condition: Unknown
Due 15 December 2001
Resolved 19 December 2001
Resolution: Corrected. SF
Lifesaving
Issued 2 November 2001 Resolved
Provide 18 CG approved adult life jackets IAW 46CFR180.71 NLT 9NOV01. Vessel is restricted from carrying more than 139 total adult persons until corrected.
Condition: Unknown
Due 9 November 2001
Resolved 19 November 2001
Resolution: Corrected. SF
Documentation
Issued 2 November 2001 Resolved
Prove compliance with drug testing regulations by completing & passing company drug program audit by CG Inspector IAW 46CFR16 NLT 9NOV01.
Condition: Unknown
Due 2 November 2001
Resolved 25 April 2002
Resolution: Administratively cleared. Case turned over to the MSO Honolulu DAPI.
Construction/Loadline
Issued 13 December 1999 Resolved
Provide visual and audible bilge high level alarms for engine rooms and lazarette IAW 46CFR182.530 NLT 13JAN00.
Condition: Unknown
Due 13 December 1999
Resolved 13 December 1999
Engineering
Issued 13 December 1999 Resolved
Starboard engine room: Renew the two exhaust cooling water hoses IAW 46CFR182.720(e) NLT 13JAN00.
Condition: Unknown
Due 13 December 1999
Resolved 13 December 1999
Construction/Loadline
Issued 13 December 1999 Resolved
Provide suitable through bulkhead fitting with suitable metallic shut off valves for non-metallic pipe penetration of STBD engine room bulkhead IAW 46CFR182.720(d) NLT 13JAN00.
Condition: Unknown
Due 13 December 1999
Resolved 13 December 1999
Construction/Loadline
Issued 13 December 1999 Resolved
Port side #1 void: Effect proper repair to fracture of #1 transverse frame in way of wingdeck IAW 46CFR176.700 NLT 13JAN00.
Condition: Unknown
Due 13 December 1999
Resolved 13 December 1999
Construction/Loadline
Issued 13 December 1999 Resolved
#10 Starboard frame on deck. Effect proper repair to fracture IAW 46CFR176.700 NLT 13JAN00.
Condition: Unknown
Due 13 December 1999
Resolved 13 December 1999
Fire Fighting
Issued 13 December 1999 Resolved
Renew piping between fire pump and #1 hydrant IAW 46CFR182.710 NLT 26DEC99.
Condition: Unknown
Due 10 January 2000
Resolved 10 January 2000
Construction/Loadline
Issued 13 December 1999 Resolved
STBD side #1 void: Weld fracture #1 transverse frame in way of wing deck. Effect proper repair IAW 46CFR176.700 NLT 13JAN00.
Condition: Unknown
Due 13 December 1999
Resolved 13 December 1999
Construction/Loadline
Issued 13 December 1999 Resolved
Port side #2 void: Verticle fracture in #1 transverse frame. Crop and renew IAW 46CFR176.700 NLT 20DEC99.
Condition: Unknown
Due 13 December 1999
Resolved 13 December 1999
Fire Fighting
Issued 16 November 1999 Resolved
Replace shaffed flexible hose off fire main in port engine room iaw 46CFR181.310.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Construction/Loadline
Issued 16 November 1999 Resolved
Repair or replace leaking through-hole in port sewage tank space (along after-bulkhead) iaw 46CFR179.320(c).
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Navigation
Issued 16 November 1999 Resolved
Repair or replace leaking hydraulic lines from #1 steering pump in stbd engine space iaw 46CFR182.610.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Navigation
Issued 16 November 1999 Resolved
Repair or replace leaking hydraulic hard piping in stbd fuel space and stbdsteering space iaw 46CFR182.610.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Accommodation/Occupational Safety
Issued 3 November 1998 Resolved
Starboard side, welded swing door in way of forward pulpit. Clean all welded surfaces and inspect for further fractures. NDT, drill stop, gouge &reweld all fractures.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 3 November 1998 Resolved
Fracture at main deck in way of forward cabin bulkhead beneath ladder. NDT, drill stop, gouge & reweld.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 3 November 1998 Resolved
Forward main deck. NDT, drill stop, gouge & reweld fracture near centerline.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 3 November 1998 Resolved
Port side #2. Fracture in transverse stiffener weld in way of deck longitudinal. Gouge & reweld.
Condition: Unknown
Due 10 November 1998
Resolved 5 January 1999
Construction/Loadline
Issued 3 November 1998 Resolved
Port engine room. Weld fracture at forward bulkhead in way on main deck. NDT, drill stop, gouge, and reweld.
Condition: Unknown
Due 10 November 1998
Resolved 5 January 1999
Construction/Loadline
Issued 3 November 1998 Resolved
Starboard side #2 space. Crop & renew wasted aluminum piping in bilge system.
Condition: Unknown
Due 10 November 1998
Resolved 5 January 1999
Engineering
Issued 3 November 1998 Resolved
Starboard lazarette. Reattach nuts to bilge strainer.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 3 November 1998 Resolved
Starboard side main deck. NDT, drill stop, gouge & reweld #8 & #10 verticalside stiffener weld fractures.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Construction/Loadline
Issued 3 November 1998 Resolved
Starboard side #2 space. Gouge & reweld sprung tack weld at vertical side stiffener in way of forward transverse bulkhead.
Condition: Unknown
Due 10 November 1998
Resolved 5 January 1999
Construction/Loadline
Issued 3 November 1998 Resolved
Starboard side #2 space. Gouge & reweld sprung tack weld in #1 transverse stiffener in way of deck longitudinal.
Condition: Unknown
Due 10 November 1998
Resolved 5 January 1999
Construction/Loadline
Issued 3 November 1998 Resolved
Starboard side #3 space. Crop & renew wasted aluminium piping in bilge system.
Condition: Unknown
Due 10 November 1998
Resolved 5 January 1999
Construction/Loadline
Issued 3 November 1998 Resolved
Port side #2 space. Fracture in transverse stiffener weld near bottom plating. Non Destructive Test (NDT) to determineends of fracture, drill stop, gouge, & reweld.
Condition: Unknown
Due 10 November 1998
Resolved 5 January 1999
Lifesaving
Issued 3 November 1998 Resolved
Provide 5 adult and 3 child Coast Guard approved PFDs. Vessel must have an approved PFD adequate foreach passenger and crew member prior to carrying passengers.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Electrical
Issued 3 November 1998 Resolved
Remove dead end wire beneath steering console.
Condition: Unknown
Due 3 December 1998
Resolved 3 December 1998
Documentation
Issued 3 November 1998 Resolved
Provide proof of FCC Safety Radio Certificate.
Condition: Unknown
Due 10 November 1998
Resolved 5 January 1999
Construction/Loadline
Issued 3 November 1998 Resolved
Portside #1 space. NDT, drill stop, gouge & reweld fractured weld in way of #1 transverse frame and inboard side shell.
Condition: Unknown
Due 10 November 1998
Resolved 5 January 1999
Construction/Loadline
Issued 3 November 1998 Resolved
Port side #1 space. Gouge & reweld sprung tack weld in way of #2 side longitudinal inboard.
Condition: Unknown
Due 10 November 1998
Resolved 5 January 1999
Construction/Loadline
Issued 3 November 1998 Resolved
Port side #1 space. Gouge & reweld fractured weld at longitudinal in way of forward bulkhead.
Condition: Unknown
Due 10 November 1998
Resolved 5 January 1999
Electrical
Issued 4 November 1997 Resolved
Provide protective guards for electrical lighting in engineroom.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Electrical
Issued 4 November 1997 Resolved
Remove all deadend wiring from MSD space.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Lifesaving
Issued 24 January 1997 Resolved
Replace weaklink with one rated for 21+ passengers.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Electrical
Issued 24 January 1997 Resolved
Provide 1 flashlight for each engineroom access as per IFR 46 CFR 183.430.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Navigation
Issued 24 January 1997 Resolved
Repair or replace leaking hyraulic ram for steering system in port lazerette.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Lifesaving
Issued 24 January 1997 Resolved
Provide 4 bands of 2" retrotape at quarters on all ringbuoys as per IFR 46 CFR 185.604(i).
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Electrical
Issued 24 January 1997 Resolved
Repair or replace Port ship service generator as per 46 CFR 183.10-5(b).
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Construction/Loadline
Issued 24 January 1997 Resolved
Mark all watertight hatches "Watertight hatch - Keep closed" as per IFR 46 CFR 185.610.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Deck/Cargo
Issued 24 January 1997 Resolved
Replace anchor rode with equivilant or better as per 46 CFR 184.10-1.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Fire Fighting
Issued 24 January 1997 Resolved
Repair or replace leaking valve at forward fire station.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Lifesaving
Issued 24 January 1997 Resolved
Replace the ringbuoy on the bridge.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Unknown
Issued 4 April 1996 Resolved
Install emergency broadcast placard IAW 46 CFR 184.506.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Unknown
Issued 4 April 1996 Resolved
Implement and log crew training IAW 46 CFR 185.420.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Navigation
Issued 4 April 1996 Resolved
Provide compass light IAW 46 CFR 184.402.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Unknown
Issued 4 April 1996 Resolved
Implement abandon ship and man overboard drills and training IAW 46 CFR 185.520.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Unknown
Issued 4 April 1996 Resolved
Implement fire fighting drills and training IAW 46 CFR 185.524.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Lifesaving
Issued 4 April 1996 Resolved
Install retroreflective tape for ring buoys IAW 46 CFR 185.604 (i).
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Engineering
Issued 4 April 1996 Resolved
Install remote fuel shutoff valve markings IAW 46 CFR 185.608.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Unknown
Issued 4 April 1996 Resolved
Implement weekly (logged) maintenance and inspection IAW 46 CFR 185.720.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Unknown
Issued 4 April 1996 Resolved
Implement annual inspection IAW 46 CFR 185.726.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Construction/Loadline
Issued 6 December 1995 Resolved
In lieu of rubber radiator hose, install approved metallic piping on the suction and discharge sides of the port and stbd power driven bilge pumps.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Documentation
Issued 6 December 1995 Resolved
Provide a written drug and alcohol policy in accordance 46CFR16 and fax to Coast Guard MSO Honolulu at [phone withheld] no later than 13DEC95.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Documentation
Issued 6 December 1995 Resolved
Provide proof of employee assistance program and supervisory training in accordance with 46CFR16 and fax to Coast Guard MSO Honolulu at [phone withheld]no later than 13DEC95.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Lifesaving
Issued 4 November 1995 Resolved
PROPERLY LABEL LIFE JACKET STOWAGE CONPARTMENTS "#LIFE PRESERVERS" & "#CHILD LIFE PRESERVERS"; CHILD LIFE PRESERVERS TO BE STOWED SEPERATE FROM ADULT LIFE PRESERVERS ALL IAW 46CFR180.25-15(b).
Condition: Unknown
Due 4 November 1995
Resolved 4 November 1995
Documentation
Issued 4 November 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 November 1995
Resolved 4 November 1995
Construction/Loadline
Issued 4 November 1995 Resolved
LABEL BIGE MANIFOLDS (P/STB) AND POST OPERATING INSTRUCTIONS TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 November 1995
Resolved 4 November 1995
Lifesaving
Issued 4 November 1995 Resolved
PROVIDE PROPER SUPPORT TO THE PIPE LEADING TO THE PORT SIDE FRESH WATER TANK TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 November 1995
Resolved 4 November 1995
Fire Fighting
Issued 4 November 1995 Resolved
REPLACE BOTH FIRE NOZZELS WITH A USCG APPROVED TYPE IAW 46CFR181.15-10(2) TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 November 1995
Resolved 4 November 1995
Accommodation/Occupational Safety
Issued 30 November 1994 Resolved
RENEW MEN'S URINAL DRAINAGE PIPE.
Condition: Unknown
Due 30 November 1994
Resolved 30 November 1994
Lifesaving
Issued 30 November 1994 Resolved
RENEW REQUIRED MARKINGS ON BUOYANT APPARATUS.
Condition: Unknown
Due 30 November 1994
Resolved 30 November 1994
Navigation
Issued 6 January 1994 Resolved
MAKE PERMANENT REPAIRS TO VESSELS DISTRESS HORN._x001C_
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Engineering
Issued 6 January 1994 Resolved
RENEW FUEL TANK VENT FLAME SCREENS WITH 30X30 MESH; BRONZE OR STAINLESS STEEL SCREEN.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Documentation
Issued 6 January 1994 Resolved
POST WASTE MANAGEMENT PLAN WITH PERSON IN CHARGE DESIGNATION.
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Construction/Loadline
Issued 26 November 1993 Resolved
REATTACH THE CAPTIVE CHAINS FOR ALL THE FLUSH DECK HATCH ASSEMBLIES LOCATEDON THE MAIN DECK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Construction/Loadline
Issued 26 November 1993 Resolved
REPLACE THE MISSING BALL CHECK ASSEMBLY FOR THE VENT ON #2S VOID._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Construction/Loadline
Issued 26 November 1993 Resolved
TEST ALL THE FLUSH DECK HATCH ASSEMBLIES FOR WATER TIGHT INTEGRITY WITH THEPOWER DRIVEN FIRE PUMP ON BOARD THE VESSEL. THIS ITEM TO BE DONE IN THE PRESENCE OF A CG MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Construction/Loadline
Issued 26 November 1993 Resolved
RENEW THE INNER O-RING GASKET FOR THE FLUSH DECK HATCH ASSEMBLY CLOSING MECHANISM ON THE #1P VOID._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Construction/Loadline
Issued 26 November 1993 Resolved
RENEW THE OUTER GASKETS ON THE FLUSH DECK HATCH ASSEMBLIES FOR THE #1P, #2P, & #2S VOIDS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Construction/Loadline
Issued 26 November 1993 Resolved
CAP OFF THE UNUSED THROUGH DECK FITTINGS LOCATED UNDER THE FORWARD LADDER LEADING TO UPPER DECK IN FRONT OF THE DECK HOUSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Electrical
Issued 26 November 1993 Resolved
REPLACE THE MISSING GLOBE FOR THE LIGHT FIXTURE IN THE #1P VOID._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Electrical
Issued 26 November 1993 Resolved
REPLACE THE MISSING GLOBE AND GUARD FOR THE LIGHT FIXTURE IN THE #2S VOID._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Electrical
Issued 26 November 1993 Resolved
PROVE LIGHT SYSTEMS DAMAGED BY HIGH WATER IN #1P & #1S VOIDS OPERATIONAL ._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Electrical
Issued 26 November 1993 Resolved
REPAIR/REPLACE AND/OR RENEW AS NEEDED ALL ELECTRICAL COMPONENTS DAMAGED BY FIRE IN ELECTRICAL BREAKER BOX FOR FIRE PUMP LOCATED IN PORT ENGINE ROOM
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Lifesaving
Issued 26 November 1993 Resolved
TEST BILGE SUCTION OPERATIVE BY PUMPING WATER OUT IN THE PRESENCE OF A CG MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Fire Fighting
Issued 26 November 1993 Resolved
DEMONSTRATE PROPER OPERATION AND REPAIR OF THE FIRE PUMP ELECTRICAL CIRCUITRY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Lifesaving
Issued 26 November 1993 Resolved
REMOVE OIL FROM BILGES IN ENGINE ROOMS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Documentation
Issued 26 November 1993 Resolved
PROVIDE A DETAILED REPORT OF THE COMPONENTS REPLACED OR REPAIRED AND DAMAGED DUE TO FIRE ON 11/26/93. INDICATE PRESUMEABLE CAUSE, SPECIFIC GAGEWIRING RENEWED, AMPERAGE FOR CIRCUITS AND RATEINGS FOR COMPONENTS._x001C_ _x001C_
Condition: Unknown
Due 15 December 1993
Resolved 15 December 1993
Navigation
Issued 12 October 1993 Resolved
REWELD STARBOARD SUPPORT BRACE ON LIGHT TOWER.
Condition: Unknown
Due 9 November 1993
Resolved 9 November 1993
Navigation
Issued 12 October 1993 Resolved
RENEW OR REFURBISH SIDE RUNNING LIGHTS AND PROPERLY MOUNT THEM TO PROVIDE UNOBSTRUCTED FORWARD VISIBILITY.
Condition: Unknown
Due 9 November 1993
Resolved 9 November 1993
Construction/Loadline
Issued 12 October 1993 Resolved
PROVIDE ORIGINAL SCANTLING FOR SIDESHELL. SEE INSPECTION NOTE FOR DETAILS.
Condition: Unknown
Due 9 November 1993
Resolved 9 November 1993
Accommodation/Occupational Safety
Issued 12 October 1993 Resolved
REWELD CRACKS ON RAILINGS AND STANCHIONS ON UPPER DECK, AS MARKED.
Condition: Unknown
Due 9 November 1993
Resolved 9 November 1993
Accommodation/Occupational Safety
Issued 12 October 1993 Resolved
RENEW PORT UPPER DECK BENCH SEAT.
Condition: Unknown
Due 9 November 1993
Resolved 9 November 1993
Accommodation/Occupational Safety
Issued 12 October 1993 Resolved
RENEW BASE OF THIRD STANCHION FROM AFT, UPPER DECK PORT SIDE.
Condition: Unknown
Due 9 November 1993
Resolved 9 November 1993
Construction/Loadline
Issued 11 February 1993 Resolved
REPAIR CRACKED WELDS IN #2 PORT COMPARTMENT AT JUNCTURE OF AFTMOST TRANSVERSE AND DECK LONGITUDINALS #4 & #5._x001C_
Condition: Unknown
Due 11 February 1993
Resolved 11 February 1993
Documentation
Issued 11 February 1993 Resolved
PROVIDE DOCUMENTATION SHOWING COMPLIANCE WITH RANDOM DRUG TESTING REGULATIONS.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Engineering
Issued 11 February 1993 Resolved
REPAIR BRIDGE GAUGES FOR PORT GENERATOR LUBRICATING OIL PRESSURE AND JACKETWATER TEMPERATURE._x001C_
Condition: Unknown
Due 11 February 1993
Resolved 11 February 1993
Navigation
Issued 11 February 1993 Resolved
REPLACE THE NAVIGATION BULBS W/ MANUFACTURER RECOMMENDED BULBS._x001C_
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Engineering
Issued 11 February 1993 Resolved
INSTALL FLAME SHIELDS ON STARBOARD MAIN ENGINE AND STARBOARD GENERATOR_x001C_ FUEL FILTERS._x001C_
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Fire Fighting
Issued 11 February 1993 Resolved
RENEW IN KIND THE FLEX HOSE ON THE FIRE PUMP DISCHARGE LINE._x001C_
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Lifesaving
Issued 6 March 1992 Resolved
PROVIDE AND PROVE A SATISFACTORY METHOD OF RETRIEVING A PERSON FROM THE WATER IN THE EVENT OF AN INDIVIDUAL FALLING OVERBOARD.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Construction/Loadline
Issued 6 March 1992 Resolved
RENEW THE FRACTURED WELDS IN THE 1ST AND 2ND OUTBOARD LONGITUDINAL STRINGERS FROM THE KEEL IN THE 2ND SPACE ON THE PORT SIDE. THE FRACTURES ARE TO BE MONITORED BY THE MASTER UNTIL PERMANENT REPAIRS CAN BE MADE AT THE NEXT DRY DOCK.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Navigation
Issued 6 March 1992 Resolved
RENEW THE LEAKING SEALS IN THE STARBOARD STEERING GEAR HYDRAULIC RAM.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Navigation
Issued 6 March 1992 Resolved
RENEW THE CLEVIS, CLEVIS PIN, AND THE COTTER PINS ON EITHER END OF THE PORTSTEERING GEAR HYDRAULIC RAM.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Lifesaving
Issued 6 March 1992 Resolved
POST AN EMERGENCY CHECK-OFF LIST ON THE MAIN DECK ACCOMMODATIONS SPACE.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Lifesaving
Issued 6 March 1992 Resolved
PROVIDE THE REQUIRED 60 FEET OF LINE FOR THE LIFE RING BUOY.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Fire Fighting
Issued 6 March 1992 Resolved
LABEL BOTH FIRE STATIONS.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Electrical
Issued 7 March 1991 Resolved
PROVIDE GLOBES FOR THE LIGHTS IN THE STEERING COMPARTMENTS AND IN THE ENGINE ROOMS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Fire Fighting
Issued 7 March 1991 Resolved
PROVIDE SPANNERS FOR BOTH FIRE STATIONS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Documentation
Issued 7 March 1991 Resolved
POST A MARPOL ANNEX V POLLUTION PLACARD ON THE VESSEL.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991 Resolved
PROVIDE COVERS FOR THE ELECTRICAL OUTLETS IN THE ENGINE ROOMS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Deck/Cargo
Issued 7 March 1991 Resolved
MAKE OPERATIONAL THE BILGE PUMP ALARMS IN COMPARTMENT #2 (P&S) OR REMOVE THEM FROM THE VESSEL.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Construction/Loadline
Issued 7 March 1991 Resolved
PERMANENTLY REPAIR THE HOLE IN THE UNDERDECK IN THE PORT FOREPEAK TANK.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Accommodation/Occupational Safety
Issued 7 March 1991 Resolved
PROVIDE A NON-RETURN VALVE TO THE MSD OVERBOARD DISCHARGE AT THE PUMP AND PROVIDE MEANS TO LOCK THE VALVES.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Fire Fighting
Issued 11 April 1990 Resolved
PROVIDE A RUBBER LINED COMMERCIAL FIRE HOSE CONFORMING TO UL STANDARD 19 FOR THE AFT FIRE STATION.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Fire Fighting
Issued 11 April 1990 Resolved
PROVIDE SPANNER WRENCHES FOR BOTH HOSE STATIONS.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Electrical
Issued 11 April 1990 Resolved
PLACE THE BATTERY LOCATED IN THE WHEELHOUSE IN A TRAY LINED WITH LEAD, PLASTIC OR FRP.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Fire Fighting
Issued 11 April 1990 Resolved
PROVIDE A HOSE RACK OR MOUNT FOR THE AFT FIRE HOSE STATION.
Condition: Unknown
Due 11 April 1990
Resolved 11 April 1990
Lifesaving
Issued 11 April 1989 Resolved
PROVIDE AN APPROVED WATERLIGHT AND ATTACH IT TO THE 20 PERSON BUOYANT APPARATUS SERIAL NUMBER 426.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Fire Fighting
Issued 11 April 1989 Resolved
MAKE REPAIRS TO AND PROVE SATISFACTORY OPERATION OF THE REMOTE FIRE PUMP CONTROL LOCATED AT FIRE STATION 2 ON THE BOW.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Fire Fighting
Issued 11 April 1989 Resolved
REPLACE THE EXISTING FIRE HOSE AT FIRE STATION 1 LOCATED ON THE STERN WITH AN APPROVED LINED COMMERCIAL FIRE HOSE 50 FEET IN LENGTH AND CONFORMING TO UL STANDARD 19.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Fire Fighting
Issued 11 April 1989 Resolved
REPLACE ALL EXISTING PLASTIC NOZZELS ON ALL FIRE HOSES WITH BRONZE NOZZELS HAVING A 1/2 INCH SOLID STREAM ORIFICE OR AN APPROVED COMBINATION NOZZEL.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Navigation
Issued 11 April 1989 Resolved
PLACE A SUITABLE LIGHT ON THE VESSEL'S MAGNETIC COMPASS.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Fire Fighting
Issued 11 April 1989 Resolved
PROPERLY MOUNT BOTH B-II PORTABLE FIRE EXTINGUISHERS IN THE ACCOMMODATION SPACE.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Accommodation/Occupational Safety
Issued 26 October 1988 Resolved
(DTD 13APR88) INSTALL METALLIC VALVES AND SPOOL PIECES IN PVC MSD PIPING FWD AND AFT OF WATERTIGHT BULKHEAD PENETRATION SEPARATING 2ND AND 3RD COMPTS IN STBD HULL (46 CFR 182.40-1).
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Accommodation/Occupational Safety
Issued 26 October 1988 Resolved
(DTD 13APR88) PROVIDE CLOSURE DEVICE FOR VENT LINE TO STBD HULL FWD COMPT. ALL SUCH VENTS SHALL HAVE SUITABLE CLOSURE DEVICES (46 CFR 177.20-1).
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Accommodation/Occupational Safety
Issued 13 April 1988 Resolved
PROVIDE SECOND SET OF HOSE CLAMPS ON SANITARY HOSE COUPLING IN 2ND COMPARTMENT FROM BOW STBD HULL.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Accommodation/Occupational Safety
Issued 13 April 1988 Resolved
PROVIDE BALL CHECK ASSEMBLY FOR VENT LINES ON FWD STBD HULL COMPARTMENTS.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Accommodation/Occupational Safety
Issued 13 April 1988 Resolved
INSTALL METAL VALVES IN PVC PIPING AT WATERTIGHT BULKHEAD PENETRATION BETWEEN 2ND AND 3RD COMPARTMENT IN THE STBD HULL.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Engineering
Issued 13 April 1988 Resolved
INSTALL 30"X30" MESH FLAME SCREENS ON BOTH FUEL TANK VENTS.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Electrical
Issued 13 April 1988 Resolved
INSTALL PROTECTIVE GUARD OVER BELT DRIVES ON BOTH S/S GENERATORS DIESELS.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Electrical
Issued 13 April 1988 Resolved
PROVIDE A COMPLETE SET OF MEGGAR READINGS FOR ALL ELECTRICAL CIRCUITS.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Navigation
Issued 13 April 1988 Resolved
HAVE VHF RADIO CHECKED FOR CAUSE OF BACKGROUND NOISES DURING TRANSMISSION AND OBTAIN VALID FCC CERTIFICATE FCC-824. VESSEL IS LIMITED TO OPERATION NOT MORE THAN 1000 FT. FROM SHORE UNTIL CERTIFICATE IS ON BOARD.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Lifesaving
Issued 13 April 1988 Resolved
PROVIDE 6 NEW PARACHUTE FLARES AND 6 NEW ORANGE SMOKE FLARES, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Unknown
Issued 29 June 1987 Resolved
PROVIDE AND ATTACH ONE ADDITIONAL RING BUOY TO THE VESSEL'S BUOYANT APPARATUS.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Unknown
Issued 30 April 1987 Resolved
REPLACE ONE BUOYANT APPARATUS WATERLIGHT.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Unknown
Issued 30 April 1987 Resolved
PROVIDE 6 ADDITIONAL ADULT LIFE JACKETS. UNTIL THIS ITEM IS CORRECTED, TOTAL PASSENGERS IS LIMITED TO 102.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Unknown
Issued 30 April 1987 Resolved
HAVE VHF RADIO SERVICED, PROVIDE COPY OF SERVICING REPORT.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Unknown
Issued 30 April 1987 Resolved
PERMANENTLY REPAIR FIRE MAIN LINE IN WAY OF AFT FIRE STATION.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Unknown
Issued 30 April 1987 Resolved
REPAIR/REPLACE SIGNAL HORN.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Unknown
Issued 30 April 1987 Resolved
REPAIR PORT SIDE EMERGENCY FUEL OIL CUTOFF VALVE.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Unknown
Issued 30 April 1987 Resolved
PROVIDE FUEL OIL FILTER FLAME DEFLECTOR SHIELDS FOR BOTH MAIN ENGINES AND GENERATOR FUEL OIL FILTERS (4 TOTAL).
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Unknown
Issued 30 April 1987 Resolved
REPAIR/REPLACE SEWAGE PUMP.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Unknown
Issued 30 April 1987 Resolved
PROVIDE ONE ADDITIONAL (6 TOTAL) B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Electrical
Issued 19 March 1985 Resolved
REWORK STARBOARD SERVICE GENERATOR EXHAUST SYSTEM. PROPERLY SUPPORT SAME.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Accommodation/Occupational Safety
Issued 19 March 1985 Resolved
RENEW WASTED BILGE SUCTION LINE AS ORIGINAL IN NO. 2 SPACE STARBOARD HULL.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Accommodation/Occupational Safety
Issued 19 March 1985 Resolved
PROPERLY INSTALL LOCKING DEVICE FOR SANITARY OVERBOARD VALVE.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Engineering
Issued 19 March 1985 Resolved
INSTALL RIGID S.W. COOLING LINE FOR WET EXHAUST SYSTEM. PROPERLY SUPPORT PIPING PORT MAIN ENGINE.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Accommodation/Occupational Safety
Issued 19 March 1985 Resolved
PROPERLY SUPPORT/INSTALL SANITARY PRESSURE SET IN NO. 2 STARBOARD HULL.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Electrical
Issued 19 March 1985 Resolved
PROPERLY INSTALL MARINE TYPE (AS ORIGINAL) ELECTRICAL CONDUCTOR FOR SANITARY PRESSURE SET NO NO. 2 SPACE STARBOARD HULL.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Electrical
Issued 19 March 1985 Resolved
RENEW ALL WASTED JUNCTION BOXES/RECEPTACLES IN NO. 2 SPACE STARBOARD HULL.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Construction/Loadline
Issued 19 March 1985 Resolved
MAKE PERMANENT REPAIRS TO FRACTURES IN WAY OF NO. 1 TRANSVERSE FRAME AND LONGITUDINAL BOTTOM, SIDE, AND DECK FRAME IN NO. 1 SPACE PORT AND STARBOARDHULLS.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Engineering
Issued 19 March 1985 Resolved
INSTALL RIGID S.W. COOLING LINE FOR WET EXHAUST SYSTEM. PROPERLY SUPPORT PIPING STARBOARD MAIN ENGINE.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Unknown
Issued 19 March 1985 Resolved
CLEAN ALL OIL FROM STARBOARD ENGINE ROOM BILGE.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Construction/Loadline
Issued 19 March 1985 Resolved
INSTALL WATERTIGHT COVERS TO ACCESSES TO VOID SPACES BETWEEN PORT AND STARBOARD ENGINEROOMS AND STEERING SPACES. REMOVE ALL STORAGE FROM VOID SPACES.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Navigation
Issued 19 March 1985 Resolved
MAKE PROPER REPAIRS TO LEAKING HYDRAULIC STEERING LINES IN PORT AND STARBOARD STEERING SPACE.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Construction/Loadline
Issued 19 March 1985 Resolved
PROVE STARBOARD STEERING SPACE HATCH COVER WATERTIGHT.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Engineering
Issued 19 March 1985 Resolved
MAKE PERMANENT REPAIRS TO ALL EXHAUST LEAKS IN STARBOARD MAIN ENGINE EXHAUST PIPING SYSTEM.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Accommodation/Occupational Safety
Issued 19 March 1985 Resolved
PLUG ALL UNUSED PIPING SYSTEMS. RENEW WASTED PIPING SYSTEMS IN USE AS ORIGINALS.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Electrical
Issued 19 March 1985 Resolved
DETERMINE CAUSE AND MAKE REPAIRS TO F.W. PRESSURE PUMP CONTROLLER, NO. 2 SPACE PORT HULL.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Accommodation/Occupational Safety
Issued 19 March 1985 Resolved
PROPERLY SUPPORT/HANG ALL PIPING IN NO. 2 SPACE, PORT HULL.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Electrical
Issued 19 March 1985 Resolved
PROPERLY HANG ALL ELECTRICAL CONDUCTORS/RENEW WASTED JUNCTION BOXES/ ELECTRICAL EQUIPMENT WHERE NECESSARY IN NO. 2 SPACE, PORT HULL.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Electrical
Issued 19 March 1985 Resolved
INSTALL RIGID EXHAUST EXCEPT FOR SMALL SECTION FOR VIBRATION TO PORT SERVICE GENERATOR EXHAUST LINE PROPERLY SUPPORT EXHAUST PIPING.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Engineering
Issued 19 March 1985 Resolved
MAKE PERMANENT REPAIRS TO ALL EXHAUST LEAKS, PROPERLY SUPPORT EXHAUST PIPING FOR PORT MAIN ENGINE.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Engineering
Issued 19 March 1985 Resolved
DETERMINE CAUSE OF EXCESSIVE EXHAUST SMOKE AND MAKE PROPER REPAIR TO PORT MAIN ENGINE.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Unknown
Issued 19 March 1985 Resolved
CLEAN ALL OIL FROM PORT ENGINEROOM BILGE.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985

Casualty record · 4

31 October 2013Routine · role: Involved in a Marine Casualty · activity 4745218
2 January 2014Routine · role: Involved in a Marine Casualty · activity 4777347
7 July 2017Routine · role: Transiting Vicinity of Primary Subject · activity 6205976
9 March 2019Routine · role: Involved in a Marine Casualty · activity 6660877
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.