POT 103 is a 1972 tank barge. The Coast Guard has recorded 60 inspections since 1982, most recently in January 2015, along with 60 deficiencies.

Records from 1982 to 2015. Most recent: inspection, 14 January 2015.

Built
1972
Last inspected
14 January 2015
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 14 January 2015
…with no type recorded14
Operational controls None recorded without a removal date
Years with a record 32 calendar years (1982–2015)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-47328

Documentation record

Registered dimensions (L × B × D)175.1 ft × 44.0 ft × 12.3 ft
Registered tonnagegross 785 / net 785
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAMERICAN MARINE CORPORATION · NEW ORLEANS, LA, UNITED STATES · built 1972
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 April 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it785 - Regulatory (Subpart C or D), Net Ton
785 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS SARAH Towing Vessel · MISLE 81635 · 21 August 2002 · activity 1729167MISS SARAH Towing Vessel · MISLE 81635 · 29 September 1999 · activity 110002ROYAL ENGINEER Towing Vessel · MISLE 88403 · 18 September 1997 · activity 143371ISLAND BOY Towing Vessel · MISLE 104192 · 1 December 1996 · activity 57162MISS OCIE Towing Vessel · MISLE 71496 · 14 May 1992 · activity 133209

Inspection history · 60

14 January 2015 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5053320
8 May 2014 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4853173
11 June 2013 MARPOL Annex I Examination · MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4616589
20 August 2012 MTSA Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4417176
2 July 2012 Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4364636
26 August 2011 Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4127708
20 September 2010 MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3850897
26 June 2009 Drydock Extension · MARPOL Annex I Examination · COI Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3514694
18 September 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3330650
20 March 2008 Damage Survey · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3168395
18 September 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3060840
23 August 2007 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3060809
30 July 2007 MTSA Verification · Hull Examination · Annual Inspection · Cargo Tank Internal
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3012219
27 September 2006 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2788351
20 September 2006 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2782672
3 August 2006 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2735235
9 January 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2563622
19 August 2005 Annual Inspection · MTSA Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2467934
9 May 2005 MTSA Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2354999
21 April 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2339868
11 March 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2307976
6 May 2004 Hull Examination · COI Inspection · MARPOL Annex I Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2061949
23 October 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979755
5 September 2003 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1897478
7 August 2003 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1867468
26 August 2002 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1666781
21 August 2002 Permit to Proceed
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1664570
21 August 2002 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1729167
4 June 2002 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1626006
5 July 2001 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1382323
8 June 2000 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 819053
30 May 2000 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1471407
29 September 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 110002
24 June 1999 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 883152
14 May 1999 Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1375767
3 June 1998 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1471996
18 September 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 143371
21 May 1997 Re-Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1105193
1 December 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 57162
9 August 1996 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1090195
3 June 1996 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1409510
8 June 1995 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1186268
8 May 1995 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1350445
1 June 1994 COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1015230
18 November 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1145089
17 November 1993 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 834087
16 September 1992 Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 956735
14 May 1992 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 133209
17 April 1991 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 910900
17 April 1991 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1222458
21 May 1990 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 901956
12 September 1989 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 896665
19 May 1989 COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1034517
6 June 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325781
29 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985284
15 October 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1296777
6 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972812
6 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282076
24 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275050
30 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275548

Deficiency record · 60

Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 11 June 2013 Resolved
Renew Oil Pressure Gauge on Stbd. pump engine.
Due 18 June 2013
Resolved 19 June 2013
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 11 June 2013 Resolved
Service/Test port and stbd PRV on both cargo pumps as per 46CFR35.35-70(B).
Condition: Improper/Lack of Maintenance
Due 18 June 2013
Resolved 19 June 2013
Construction/Loadline › Penetrations › Gasket
Issued 20 August 2012 Resolved
Repair fwd, aft hatch gasket to satisfaction of attending MI.
Due 15 September 2012
Resolved 21 August 2012
Resolution: Vessel owner repaired hatch and was witnessed by ABS surveyor.
Construction/Loadline › Markings › Fresh Water Load Line
Issued 20 August 2012 Resolved
Place proper lettering on port and stbd plimsoll mark (load line) to satisfaction of attending MI.
Due 20 August 2012
Resolved 20 August 2012
Resolution: Vessel representative corrected discrepancy on the spot.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 August 2009 Resolved
Determine/investigate source of bad air supply, and provide results to Coast Guard in writing.
Action required: 705 - Other - as specified
Resolved 24 August 2009
Resolution: No source found.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 August 2009 Resolved
Re-certify via certified marine chemist all spaces on all barges fed by air supply.
Action required: 705 - Other - as specified
Resolved 24 August 2009
Resolution: All spaces re-certified safe by certified marine chemist.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 August 2009 Resolved
Halt all internal work on all barges until otherwise directed, or until tested safe by a certified marine chemist.
Action required: 705 - Other - as specified
Resolved 24 August 2009
Resolution: All spaces certified safe by a marine chemist.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 August 2009 Resolved
Provide specifications for shipyard gas-free meter and provide calibration and servicing by certified technician.
Action required: 705 - Other - as specified
Resolved 24 August 2009
Resolution: New device provided as old device was found to be faulty.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 26 June 2009 Resolved
Provide testing of cargo pump relief valves(2) IAW 46 CFR 35.35-70(b).
Due 9 October 2009
Resolved 14 September 2009
Resolution: Pump relief valves satisfactorily tested.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 26 June 2009 Resolved
Renew gasket on #3 STBD hatch.
Due 9 October 2009
Resolved 9 September 2009
Resolution: gasket renewed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 26 June 2009 Resolved
Calibrate or renew discharge manifold gage.
Due 9 October 2009
Resolved 9 September 2009
Resolution: Renewed gage.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 26 June 2009 Resolved
Demonstrate proper operation of all cargo gaging devices prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2009
Resolution: All gages operating properly.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 26 June 2009 Resolved
Provide open/closed indicators on all cargo valves.
Due 9 October 2009
Resolved 14 September 2009
Resolution: Indicators provided.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 18 September 2008 Resolved
Wire rope on boom showed signs of damage, Company to replace
Due 19 September 2008
Resolved 22 September 2008
Resolution: Wire rope replaced with new
Construction/Loadline › Hull › Hull Plating
Issued 20 March 2008 Resolved
Crop and renew the bottom, center hull plate over the #1 port and stbd cargo tanks. Crop the good steel.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2008
Resolution: Air test insert with 1.75 PSI on Cargo tanks
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 March 2008 Resolved
Crop and renew appx. 5ft of the bulkhead between the #1 port and stbd cargo tanks, in-way of the fwd bulkhead.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2008
Resolution: Air test Cargo tanks with 1.75 PSI,
Construction/Loadline › Hull › Stiffener
Issued 20 March 2008 Resolved
In the bow rake. Repair two deck longs and two bulkhead stiffeners, in-way of the aft bulkhead.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2008
Resolution: Hose test repair
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 23 August 2007 Resolved
Vessel found operating without a valid COFR.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2007
Resolved 27 August 2007
Resolution: Vessel obtained valid COFR.
Engineering › Fuel Oil Service System › Hose
Issued 20 September 2006 Resolved
Port engine fuel tank return line corroded at hose end fitting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 27 September 2006
Resolution: Hose end fitting replaced
Engineering › Fuel Oil Service System › Valve
Issued 20 September 2006 Resolved
Port engine fuel tank supply valve missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 27 September 2006
Resolution: Valve replaced
Engineering › Fuel Oil Service System › Hose
Issued 20 September 2006 Resolved
Provide chaffing gear to secure starboard engine fuel tank return line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 27 September 2006
Resolution: Chaffing gear placed on return line.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 20 September 2006 Resolved
Port engine emergency shutdown cable piping wasted approximately 12 feet forward of engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 27 September 2006
Resolution: Rubber sleeve placed over wasted area.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 20 September 2006 Resolved
Replace #2 starboard PV Valve, #1 port & starboard, #2 port cargo tank sample post, starboard fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 27 September 2006
Resolution: Flame screens replaced
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 September 2006 Resolved
Obtain original copy of COD
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 27 September 2006
Resolution: New copy obtained.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 20 September 2006 Resolved
Repaint draft markings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 27 September 2006
Resolution: Draft markings repainted
Construction/Loadline › Markings › Load Line Mark
Issued 20 September 2006 Resolved
Repaint load line markings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 27 September 2006
Resolution: Load line markings repainted
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 20 September 2006 Resolved
Repaint vessel name and home port on stern.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 27 September 2006
Resolution: Vessel name and homeport repainted on stern
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 20 September 2006 Resolved
Port fire extinguisher mounting bracket corroded and in need of repair or replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 27 September 2006
Resolution: Port fire extinguisher mounting bracket replaced.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 19 August 2005 Resolved
Repair / Renew emergency shutoff and warning signs.
Action required: 705 - Other - as specified
Due 19 September 2005
Resolved 3 August 2006
Resolution: Shutoff repaired and a new sign posted..
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 7 August 2003 Resolved
01 Fire ext found expired and missing from vessel, Ext is to be use during cargo ops LEGACY COMPONENT DESC: Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2003
Resolved 5 September 2003
Resolution: Attended vsl cleared
Deck/Cargo › Holds/Tanks
Issued 7 August 2003 Resolved
Reachrod packing gland assembly lose with no packing installed, reachrod show's sign of wastage around stem. Vessel needs to replace reachrod and repair gland, and prove proper operation LEGACY COMPONENT DESC: Valve, Pressure Vacuum Relief
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2003
Resolved 5 September 2003
Resolution: Attended vsl cleared
Pollution Prevention/Response › Prevention Equipment
Issued 7 August 2003 Resolved
Compartment door wasted off hinges, replace door on shed/workstation.
Due 7 September 2003
Resolved 5 September 2003
Resolution: Attended vsl cleared
Construction/Loadline › Hull
Issued 21 August 2002 Resolved
Barge attended by MI's and found to have leaked cargo (JP-5). Hole could not be located. Barge issued permit to proceed to Jacksonville, FL from Beaufort, SC. Barge not permitted to conduct any cargo ops until repairs are approved by an attending [name withheld]: Hull Plating
Condition: Unknown
Due 24 August 2002
Resolved 29 August 2002
Resolution: Inspected repairs to hull, found sat, returned barge COI.
Construction/Loadline
Issued 30 May 2000 Resolved
REPAIR OR REPLACE WTH TO STERN VOID.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Documentation
Issued 30 May 2000 Resolved
PROVIDE BENZENE SIGN PRIOR TO CARRYING A BENZENE CARGO.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Engineering
Issued 30 May 2000 Resolved
PROVE PROPER OPERATION OF THE STBD. CARGO PUMP DIESEL ENGINE AND EMERGENCY PULL CABLE SHUTDOWN.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Deck/Cargo
Issued 30 May 2000 Resolved
CARGO TANK #2 STARBOARD REACH ROD REQUIRES AN OPERABLE PACKING GLAND.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Documentation
Issued 14 May 1999 Resolved
PROVIDE A VALID BENZENE PLAN AND SIGN ABOARD THE VESSEL.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Deck/Cargo
Issued 14 May 1999 Resolved
Provide a ventilated metal hood or metal housing for each cargo pump engineprior to 07Jun99.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Deck/Cargo
Issued 3 June 1998 Resolved
REPLACE PACKING ON CUTOUT VALVE RODS, IN WAY OF ALL 6 CARGO TANKS.
Condition: Unknown
Due 18 August 1998
Resolved 18 August 1998
Deck/Cargo
Issued 3 June 1998 Resolved
REPLACE INADEQUATE CARGO PRESSURE GAUGE IN WAY OF THE MANIFOLD, WITH A SUITABLE GAUGE HAVING NLT 1/2" NUMBERS, EASILY READ FROM PIC'S OPERATING STATION.
Condition: Unknown
Due 18 August 1998
Resolved 18 August 1998
Electrical
Issued 3 June 1998 Resolved
REMOVE DEADWIRING FROM CIRCUIT BOX IN DECKHOUSE.
Condition: Unknown
Due 18 August 1998
Resolved 18 August 1998
Fire Fighting
Issued 3 June 1998 Resolved
PROVIDE SERVICING FOR 2 CO2 PORTABLE EXTINGUISHERS ON BOARD, OR RMV FM BARGE.
Condition: Unknown
Due 18 August 1998
Resolved 18 August 1998
Deck/Cargo
Issued 3 June 1998 Resolved
OBTAIN HYDROSTATIC TEST OF CARGO PIPING MANIFOLD AND ALL CARGO HOSES ATTACHED, AND PROPERLY MARK THEM.
Condition: Unknown
Due 18 August 1998
Resolved 18 August 1998
Construction/Loadline
Issued 3 June 1996 Resolved
RENEW MISSING HATCH COVER DOG, #3 STARBOARD CARGO TANK NO LATER THAN NEXT DRYDOCK.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Deck/Cargo
Issued 3 June 1996 Resolved
RESURFACE AND CLEAN ULLAGE OPENINGS (STEEL SEALING SURFACE IS WASTED).
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Navigation
Issued 3 June 1996 Resolved
REPAIR STAND FOR TOWING LIGHT.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Deck/Cargo
Issued 3 June 1996 Resolved
REPACK REACH RODS AND REPLACE REACH RODS AT NEXT DRYDOCK.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Deck/Cargo
Issued 3 June 1996 Resolved
HYDROSTATICALLY TEST CARGO HOSES AND STENCIL CARGO HOSES PRIOR TO THE TRANSFERING OF CARGO.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Deck/Cargo
Issued 8 May 1995 Resolved
REPAIR/RENEW AS ORIGINAL ONE (1) P/V VALVE ON #2 STBD CARGO TANK.
Condition: Unknown
Due 8 May 1995
Resolved 8 May 1995
Construction/Loadline
Issued 1 June 1994 Resolved
Provide a copy of Belt gauging report.
Condition: Unknown
Due 30 June 1994
Resolved 7 June 1994
Documentation
Issued 1 June 1994 Resolved
Provide copy of a valid Loadline Certificate. Vessel is prohibited from operating seaward of the Boundary Line until this requirement is completed.
Condition: Unknown
Due 10 June 1994
Resolved 7 June 1994
Documentation
Issued 17 November 1993 Resolved
PLACE IN OIL TRANSFER PROCEDURES AN UPDATED LIST OF TANKERMAN/PERSON IN CHARGE IAW 33CFR155.700.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Deck/Cargo
Issued 17 November 1993 Resolved
HYDROSTATICALLY TEST ALL CARGO HOSE IAW 33CFR156.170 PRIOR TO USING FOR TRANSFER OF CARGO. MARK HOSE OR MAINTAIN WRITTEN RECORD ON BOARD VESSEL.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Deck/Cargo
Issued 17 November 1993 Resolved
HYDROSTATICALLY TEST STEEL CARGO TRANSFER MANIFOLD IAW 33CFR156.170 TO AT LEAST 1.5 TIMES RELIEF VALVE SETTING. MARK MANIFOLD OR MAINTAIN WRITTEN RECORD ON BOARD VESSEL.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Documentation
Issued 17 November 1993 Resolved
PLACE "DISCHARGE OF OIL PROHIBITED" PLACARD IN CONSPICUOUS LOCATION ON BARGE IAW 33CFR155.450.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Deck/Cargo
Issued 21 May 1990 Resolved
INSTALL GUARDS AROUND FANS AND BELTS OF BOTH PUMP DRIVE ENGINES.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Deck/Cargo
Issued 21 May 1990 Resolved
INSTALL FLAME SCREENS IN VENTS FOR BOTH ENGINE'S FUEL TANKS.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Deck/Cargo
Issued 21 May 1990 Resolved
DEMONSTRATE HYDROSTATIC TESTING OF THE CARGO PIPING AND HOSES.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Documentation
Issued 29 May 1986 Resolved
PROVIDE VALID MAILING ADDRESS FOR VESSEL' S CURRENT OPERATOR. MAIL SENT TOPRESENT ADDRESS ON COI IS RETURED AS UNDERLIVERABLE.
Condition: Unknown
Due 29 May 1986
Resolved 29 May 1986

Ownership record