Inspection history · 53
31 March 2026
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8351435
3 June 2025
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8155979
10 September 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7999622
4 January 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7845789
4 January 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7848667
12 September 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7790274
11 April 2022
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7428841
11 April 2022
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7471873
3 November 2021
Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7344955
9 July 2019
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6750500
25 January 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6617854
24 January 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6633396
23 January 2019
Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6614728
24 July 2018
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6490023
16 July 2018
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6482117
16 July 2018
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6482260
16 July 2018
Marine Casualty Follow Up · Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6482868
8 June 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6475524
22 October 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6052781
18 October 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6048304
19 July 2015
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5201848
18 July 2015
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5201798
14 April 2015
Industry Initiated Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5796056
29 March 2015
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5093567
17 February 2015
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5070653
8 January 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4780124
29 November 2013
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4769883
17 September 2013
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4722760
8 April 2013
DAPI Audit
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4564593
20 December 2012
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4510816
16 July 2012
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4380836
11 August 2011
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4112368
6 July 2011
DAPI Audit · Industry Initiated Exam · Deficiency Check · Administration
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4071803
25 June 2011
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4061432
29 October 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3882415
14 July 2010
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3812930
28 January 2010
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3671800
17 December 2001
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1473847
5 December 2001
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1480715
14 December 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 643945
13 December 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 435741
18 August 1999
Uninspected Towing Vessel
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 779295
25 March 1999
Type not recorded
No type recorded · Station Georgetown · USCG Southeast District (CGD-SE) · Activity 1508578
23 February 1998
Uninspected Towing Vessel
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1117287
18 November 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 664668
18 September 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 143371
17 September 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 212086
3 June 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 69777
3 June 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 222225
3 June 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 230143
11 April 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 93885
16 April 1994
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 79771
24 February 1994
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 140735
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 January 2024
Resolved
Any vessel of at least 5 net tons which engages in coastwise trade, must have a COD bearing valid endorsement. Vessel was operating on 4 Jan, 2024, with a COD that expired on 31 Dec, 2023.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2024
Resolution: New COD provided via email from O/O.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 September 2023
Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the lifejackets stowed inside the container. The equipment may be identified in words or with the appropriate symbol from IMO Resolution A.760(18)
Life jacket storage areas are not marked.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 12 September 2023
Resolution: life jacket stowage marked
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 12 September 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention.
High bilge levels
Fwd hold missing bilge high level alarm
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 14 September 2023
Resolution: installed bilge high level alarm in fwd hold.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 12 September 2023
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route.
fwd hold hatch wasted and warped provide repair proposal
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 25 September 2023
Resolution: New hatch cover fabricated and installed, passed satisfactory hose test.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 12 September 2023
Resolved
Acceptable methods of securing the device include—
(1) Closing the seacock and removing the handle;
(2) Padlocking the seacock in the closed position;
(3) Using a non-releasable wire-tie to hold the seacock in the closed position; or
(4) Locking the door to the space enclosing the toilets with a padlock or door handle key lock.
sewage ovbd missing ability to be locked or secured
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 14 September 2023
Resolution: added ability to lock ovbd valve.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 September 2023
Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section.
fire main on stbd side has leak
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 14 September 2023
Resolution: Repaired the leak.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 September 2023
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation.
multiple nav lights partially extinguished, restricted to daytime and clear visibility operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 September 2023
Resolution: cleaned or replaced worn navigation lights.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 September 2023
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route.
both galley and port E/R weather tight doors failed hose test
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 14 September 2023
Resolution: hatches were adjusted and tested satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 July 2022
Resolved
Make permanent repairs to small hole (old mount) in superstructure (Aft of WTD STBD side) IAW 46CFR144.200. Currently a temp repair is installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 11 July 2022
Resolution: Small hose has been plugged with a bolt, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2022
Resolved
Remove dead end wiring in wheelhouse associated with bridge radio IAW 46CFR143.230(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 11 July 2022
Resolution: Dead end wiring removed, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 July 2022
Resolved
Replace/repair oil pressure sending unit (port) and the guage for oil pressure portside in the engine room IAW 46CFR143.230.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 11 July 2022
Resolution: Gauges replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 July 2022
Resolved
Replace temp sensor on port generator IAW 46CFR143.230.
Action required: 10 - Deficiency Rectified
Due 6 July 2022
Resolved 6 July 2022
Resolution: Temp sensor replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 July 2022
Resolved
Refasten loose generator head tank. The tank is loose and ready to collapse. Repair IAW 46CFR143.205(a)
Action required: 10 - Deficiency Rectified
Due 6 July 2022
Resolved 6 July 2022
Resolution: Tank properly fastened, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 November 2021
Resolved
Machinery must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions.
Propulsion machinery, including main engines and systems must be maintained to ensure proper operation.
During a scheduled damage survey, M/I’s expanded the inspection and discovered both main diesel engines, have been accumulating excessive air into the cooling water system preventing them from operating properly as designed. The crew reported having to bleed both keel coolers, particularly the port every three hours to prevent an overheat condition. It was reported by crew this condition on several occasions, when not bleed in time, has led to the expansion tank relieving hot water from the overhead of the engine room. Which poses a serious personnel hazard beneath, when doing rounds or maintenance.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 November 2021
Resolution: Port Engineer installed six new fuel injector copper sleeve kits with necessary seals. MI attended vessel to verify corrections were made IAW provided service report. Report is located in documents section.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 November 2021
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following;
(a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids.
M/I's observed an excessive amount of unmaintained oil and fuel mixture in the vessels engine rooms bilges. The crew stated this conditions had been had been ongoing for about three weeks. The total amount of mixture, appeared to be approximately 400-500 gallons. This posed a serious personnel hazard and an undue fire risk on board.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 5 November 2021
Resolution: Oily mixture from engine room bilges were pumped to a shore side containment truck for proper disposal. Bilges were steam cleaned professionally and wiped down to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 November 2021
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following;
(a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids.
M/I's observed multiple fuel oil leaks on the following machinery: the port and starboard main diesel engines supply and return lines, including the starboard filter housing. The starboard generator had soaked rags which presented a fire hazard, the source appeared to be the high pressure injection pumps and lines.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 15 November 2021
Resolution: M/I conducted operational test of all machinery and verified all leaks were repaired to the the satisfaction of the attending inspector.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 5 November 2021
Resolved
Nothing in this subpart limits the marine inspector from conducting any test or inspections they deem necessary to be assured of the vessels sea worthiness or fitness for its routes and service.
After removal of hatches for purpose of damage survey, it was discovered the forward space had approximately 4-8" of unmaintained water within the space. As well, the aft void space had approximately 2-3'. When asked about the amount of water in the space, the master stated he uses it as ballast. Given the void was only half full, M/I questions the stability arrangement and due to the lack of documentation attesting to the acceptability as utilized on board.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2021
Resolution: Master provided stability attestation for vessel, which was found satisfactory of the attending inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 November 2021
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly.
M/I noted the aft port engine room, water tight door was completely missing the gasket to make the door water tight as designed. Multiple hatches were observed wasted throughout the vessel. Additionally, the hatch forward leading into the storage room on lower fore deck, had hinges severally wasted preventing them from closing effectively and being watertight.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2021
Resolution: M/I conducted operational test of all water tight hatches, scuttles, and verified all were repaired and working as designed to the the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 November 2021
Resolved
Machinery must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions.
Propulsion machinery, including main engines and systems must be maintained to ensure proper operation.
M/I noted the starboard propeller has damage to the multiple blade tips and fractures.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2021
Resolution: Attending inspector conducted visual inspection of installation of repaired propeller. Prop scan and work was completed by third party, found satisfactory to the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 November 2021
Resolved
Machinery must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions.
Propulsion machinery, including main engines and systems must be maintained to ensure proper operation.
The company reported the vessel has experienced a leak in the keel cooler on the starboard main engine. During the initial haul out it was noted water was draining from the starboard side in the vicinity of the hull coolers.
Determine the cause and extent of the repairs to be made proper in accordance with the provisions of 46 CFR 143.205. Provide a repair plan to be approved to the satisfaction of the attending Coast Guard.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 5 November 2021
Resolved 17 November 2021
Resolution: Port Engineer installed six new fuel injector copper sleeve kits with necessary seals. MI attended vessel to verify corrections were made IAW provided service report. Report is located in documents section.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 3 November 2021
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly.
During an expanded inspection, M/I's noted it took the crew 2-3 minutes of beating with metal sledge hammer on the forward fore peak hatch to gain entrance.
Additionally, the same method was observed at the aft void space hatches to gain entrance. All three hatches were observed painted over and unmaintained.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 15 November 2021
Resolution: M/I conducted operational test of all water tight hatches, scuttles, and verified all were repaired and working as designed to the the satisfaction of the attending inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 July 2018
Resolved
Hole in port bow repair damage in associated area by way od an deck and side shell insert
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Due 24 August 2018
Resolved 28 August 2018
Resolution: Conducted multiple inserts on the bow.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2018
Resolved
Multiple cracks in way of port and stbd struts. Major wastage in both port and stbd struts. Hole in stbd stern tube. Crop and renew.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Due 24 August 2018
Resolved 28 August 2018
Resolution: Struts were repaired via crop and renew cracked or wated areas. STBD stern tube was cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 July 2018
Resolved
Both rudders have excessive play in the pintle and gudgeon bearings. Renew all associated bearings to acheive manufactures specifications.
Action required: 30 - Ship detained
Due 24 August 2018
Resolved 28 August 2018
Resolution: Rudder stocks were replaced and bearing renewed.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 13 December 1999
Resolved
A violation of 47 CFR 80.25 in that the UTV ROYAL ENGINEER was operating without a valid FCC ships license.
Condition: Unknown
Due 13 January 2000
Resolved 3 August 2010
Resolution: Cleared deficiency due to the amount of time passed since the issue date.
Navigation › Piloting/Steering › Magnetic Compass
Issued 13 December 1999
Resolved
A violation of 33 CFR 164.72 (a)(4) in that the UTV ROYAL ENGINEER operating underway without a magnetic compass.
Condition: Unknown
Due 13 January 2000
Resolved 3 August 2010
Resolution: Cleared deficiency due to the amount of time passed since the issue date.
Lifesaving › Lifebuoys › Serviceable
Issued 13 December 1999
Resolved
A violation of 46 CFR 25.25-5(d) in that the UTV ROYAL ENGINEER was operating with a substandard life ring buoy.
Condition: Unknown
Due 13 January 2000
Resolved 3 August 2010
Resolution: Cleared deficiency due to the amount of time passed since the issue.
Documentation
Issued 23 February 1998
Resolved
PROVIDE ORIGINAL VESSEL CERTIFICATE OF DOCUMENTATION
Condition: Unknown
Due 23 February 1998
Resolved 9 March 1998
Lifesaving
Issued 23 February 1998
Resolved
PROVIDE DISTRESS FLARES FOR VESSEL
Condition: Unknown
Due 23 February 1998
Resolved 9 March 1998