Records from 1996 to 2026. Most recent: inspection, 6 January 2026.
Inspection history · 48
6 January 2026
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8290541
14 January 2025
Annual Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8075396
19 December 2023
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7838963
7 February 2023
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7633564
12 April 2022
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7429405
27 December 2021
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7372851
22 November 2021
Initial Certification · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7355913
25 October 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7103808
27 September 2020
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7073038
4 December 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6867850
12 April 2019
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6665287
9 May 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6409831
27 March 2018
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6399753
20 August 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6245780
4 June 2017
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6168629
3 September 2016
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5994387
12 July 2016
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5937742
1 March 2016
Administration · DAPI Audit · Industry Initiated Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5825432
8 August 2015
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5211571
29 March 2015
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5093567
3 March 2015
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5081798
11 February 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4801891
27 June 2013
Administration
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4633075
12 April 2012
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4285386
29 November 2010
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3901441
29 December 2009
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3656721
19 December 2006
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2847589
2 March 2006
Type not recorded
No type recorded · Station Emerald Isle · USCG East District (CGD-E) · Activity 2594301
1 March 2006
Type not recorded
No type recorded · Station Emerald Isle · USCG East District (CGD-E) · Activity 2594561
14 February 2006
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2586377
11 January 2006
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2580704
1 January 2006
Type not recorded
No type recorded · Station Fort Macon · USCG East District (CGD-E) · Activity 2559411
21 July 2004
Type not recorded
No type recorded · Station Oak Island · USCG East District (CGD-E) · Activity 2145494
18 March 2004
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2026894
4 June 2003
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1828144
5 July 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1647567
16 August 1999
Uninspected Towing Vessel
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1114809
5 February 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 193194
5 February 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 761103
20 December 1997
Uninspected Towing Vessel
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1105090
10 December 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 168779
18 March 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 652602
25 February 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 193143
17 October 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 652603
3 October 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 51036
23 September 1996
Type not recorded
No type recorded · District 7 (B) · USCG Southeast District (CGD-SE) · Activity 652604
29 March 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 690688
17 March 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 99210
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 January 2025
Resolved
Piping and tanks exposed to the outside of the hull must be made of metal and maintained in a leak free condition. Port generator exhaust found leaking into the eng room.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 March 2025
Resolution: Received email from vessel rep that elbow joint has been replaced and working properly
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 14 January 2025
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Vessel had 1 expired rocket, 2 which expire at the end of the month.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2025
Resolution: New rockets were ordered and placed into service on the vessel per email from vessel rep.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 February 2023
Resolved
The following items must be recorded in the TVR or log book: Personnel safety orientation. The master did not have his orientation in the log.
Action required: 10 - Deficiency Rectified
Resolved 7 February 2023
Resolution: Vessel operations manager conducted and logged the master's training on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe
operation of the towing vessel and safety of persons onboard under normal and emergency
conditions. The hydraulic piping support straps were not properly reinstalled as designed.
Action required: 10 - Deficiency Rectified
Resolved 7 February 2023
Resolution: New straps were installed on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Open wires in the wheel house crawl space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2021
Resolved 5 January 2022
Resolution: No open wires were identified and any hanging wirs were properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
wire nuts connecting the fire detection panel power supply
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2021
Resolved 5 January 2022
Resolution: Compression conectors were fitted in way of the power supply for the fire detection system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 December 2021
Resolved
Working in an area on the exterior of the vessel without rails and guards must wear a lifejacket meeting requirements in 46 CFR 141.340, an immersion suit meeting requirements in 46 CFR 141.350, or a work vest approved by the Commandant under 46 CFR subpart 160.053.
Work vests not of approved type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 5 January 2022
Resolution: Observed five new work vests with approval number CG 160.053, marked with the vessel name and fitted with lights and whistles.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 December 2021
Resolved
A fixed fire pump must be capable of:Being energized remotely from a safe place outside the engine room and at the pump.
no local fire pump controller
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 5 January 2022
Resolution: A local switch was installed at the pump location in the port side engineroom. Pump was started locally and found to be in satisfactory operation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.DC switch panel and main switch board not dead front type
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 5 January 2022
Resolution: Main switch board panel was observed to be a dead front type.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 December 2021
Resolved
Individuals, other than crewmembers, must be provided with sufficient information or training on hazards relevant to their potential exposure on or around the vessel.
chemicals not labeled as directed by health and safety plan
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 January 2022
Resolved 5 January 2022
Resolution: Spot checked chemicals on board and found proper warning labels on the containers.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 December 2021
Resolved
Every towing vessel equipped with an inflatable survival craft must have, in conspicuous places near each inflatable survival craft, approved placards or other posted instructions for launching and inflating inflatable survival craft.
missing life raft launching instructions
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 5 January 2022
Resolution: Launching instructions were posted at the life raft launching station.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 6 December 2021
Resolved
Prior to getting underway, the master or officer in charge of a navigational watch of the vessel must examine and test the steering gear, signaling whistle, propulsion control, towing gear, navigation lights, navigation equipment, and communication systems of the vessel. Crew unfamiliar with the operation of Rose point
(navigation charts and publications program)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 5 January 2022
Resolution: The master demonstrated ability to use the Rose Point Program to obtain nav publications, tidal data and latest notice to mariners.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 6 December 2021
Resolved
The instructions supplied by the manufacturer must contain directions for each of the following:Installation of a vent or flue pipe.
MSD vent broken and venting in the engine room
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 13 January 2022
Resolution: Received photographic evidence of a new MSD, Type II tank installed on the vessel.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 6 December 2021
Resolved
Each device must have a placard suitable for posting on which is printed the operating instructions, safety precautions, and warnings pertinent to the device. The size of the letters printed on the placard must be one-eighth of an inch or larger.
MSD operating placard not posted
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 13 January 2022
Resolution: Received photographic evidence of a new MSD, Type II tank installed on the vessel.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 6 December 2021
Resolved
Each production device must be legibly marked in accordance with paragraph (b) of this section.
MSD label not proper, states was mfg 10/21 but is existing
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 13 January 2022
Resolution: Received photographic evidence of a new MSD, Type II tank installed on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 December 2021
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided:High bilge levels;
No bilge level sensor provided for bow hold
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 5 January 2022
Resolution: A new float switch was added to the bow hold. Alarm was tested and found satisfactory. The alarm display for the bow hold is located on a separate panel on the portside of the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 6 December 2021
Resolved
Annual instruction for each crew member. Unless otherwise stated, each crewmember must receive the instruction required by this section annually. Missing annual abandon ship training
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 December 2021
Resolution: Conducted abandon ship drill
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 December 2019
Resolved
Propulsion machinery, including main engines must be maintained to ensure proper operation. Stbd main engine spring for governor is breaking free from bracket. Failure will lead to loss of control of MDE.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2019
Resolved 16 December 2019
Resolution: Bracket for governor was replaced in-kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 December 2019
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquids. Port generator windings are soaked in oil from prime mover. Engine is leaking into bilge. Clean generator windings and secure leaks.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2019
Resolved 16 December 2019
Resolution: Oil leaks are secured and windings were cleaned.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 December 2019
Resolved
All seals and gaskets must be maintained to prevent leaks of flammable or combustible liquids. Stbd fuel tank fwd sight glass valve is leaking fuel. Additionally fuel leaks in E/R must be identified and secured.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2019
Resolved 16 December 2019
Resolution: Leaks in engine room were addressed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 December 2019
Resolved
Each towing vessel must have a reliable means to provide notification when a emergency condition exist for high bilge levels. E/R does not have bilge alarms.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2019
Resolved 16 December 2019
Resolution: High level bilge alarm is operational.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 4 December 2019
Resolved
Each towing vessel must be fitted with a general alarm. E/R General alarm does not sound or flash.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2019
Resolved 16 December 2019
Resolution: General alarm is operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 December 2019
Resolved
A towing vessel pushing ahead must be equipped with an approved 160-B. Hose connecting to horn is cracked, service extinguisher.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2019
Resolved 16 December 2019
Resolution: Hose was replaced and service report was issued.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 December 2019
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. This extinguisher is in addition to the required. Additionally remove any flammable paint or products from fwd hold.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2019
Resolved 16 December 2019
Resolution: Extinguisher was provided for locker and hold was cleared of flammable products.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 December 2019
Resolved
All seals and gaskets must be maintained to prevent leaks. Engine room has 4-6" of oil, fuel and water in bilge. This condition is a fire and personnel hazard. Remove fluid and secure leaks.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2019
Resolved 16 December 2019
Resolution: Bilge slops were removed from vessel's bilge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 December 2019
Resolved
Machinery and electrical systems must be maintained to provide safety to persons on board under normal and emergency conditions. Stbd gen alternator is missing the cover exposing wires and terminals.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2019
Resolved 16 December 2019
Resolution: Covers were provided for terminals.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 December 2019
Resolved
Record of drills and instructions must be maintained in TVR or official log book. Ensure fire and man overboard drills are being recorded and conducted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2019
Resolved 16 December 2019
Resolution: Drills were conducted and are being recorded in official log book.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 4 December 2019
Resolved
Health and safety plan must be implemented by 22 July 2019 and is not available to crew or USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2020
Resolved 5 January 2022
Resolution: Reviewed the Company Health and Safety Plan and found it met the requirements of 46 CFR 140.500.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 4 December 2019
Resolved
Results of examination of Pre-underway checks and testing must be recorded in TVR or official log book. No record is being made.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2019
Resolved 16 December 2019
Resolution: Pre-underway checks are being recorded in log book.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 4 December 2019
Resolved
A record of type, size and service of each two line, face wire and spring line used to make the towing vessel fast to her tow must be made available to the USCG for review. No towing record is available.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2019
Resolved 16 December 2019
Resolution: Weekly check sheets were created and are being maintained.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 4 December 2019
Resolved
The OCMI may require additional examinations of the vessel when he or she discovers damage or deterioration to the hull or structural members that may affect the seaworthiness or fitness. Fwd stbd facing wire winch deck plating is deteriorating below the winch. Repair at next dry-dock.
Action required: 705 - Other - as specified
Due 5 December 2019
Resolved 5 December 2019
Resolution: Repairs to be completed at 2024 DDX.
Navigation
Issued 20 December 1997
Resolved
PROVIDE AN 8" BELL FOR VESSEL.
Condition: Unknown
Due 20 December 1997
Resolved 30 January 1998