Records from 1997 to 2026. Most recent: inspection, 1 July 2026.
Documentation record
Registered dimensions (L × B × D)65.0 ft × 24.4 ft × 9.1 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · AMELIA, LA, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portYONGES ISLAND, SC
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 38
1 July 2026
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8416621
3 September 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8227558
20 June 2025
Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8266752
12 March 2025
Deficiency Check · Drydock Exam · Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8092058
22 July 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7961573
29 March 2023
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7659431
22 March 2022
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7417059
6 December 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7370855
28 November 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7357968
27 November 2021
Administrative Inspection · In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7359650
26 November 2021
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7864559
8 June 2021
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7222476
22 July 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7013171
7 July 2020
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6999277
4 July 2020
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7011436
26 June 2020
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6999325
9 June 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6972125
25 May 2020
In-Service Inspection · Internal Structural Exam · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6959785
25 May 2020
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6970885
13 May 2020
Administrative Inspection · Initial Certification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6951800
27 November 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6866645
25 January 2019
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6617854
27 December 2018
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6611094
17 March 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5835261
20 October 2015
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5746671
8 April 2015
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5099416
5 February 2015
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5161175
1 December 2014
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5033280
19 September 2014
Industry Initiated Exam · DAPI Audit · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4987622
1 November 2011
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4208280
28 July 2011
Industry Initiated Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4097384
20 August 2006
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2758613
14 June 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2680197
18 August 2001
Type not recorded
No type recorded · Station Wrightsville Beach · USCG East District (CGD-E) · Activity 1520371
6 April 2001
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 165130
23 February 1998
Uninspected Towing Vessel
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1094032
28 September 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 82661
8 March 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 133907
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 1 July 2026
Resolved
The fire detection system must provide visual alarms that identify the zone of origin of the fire. During operational testing of detectors in the fidley and galley, the visual alarm did not correctly identify the zone of origin of the activated detectors. Correct the fire detection system to ensure all zones are properly identified and the visual alarm accurately indicates the zone of origin.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2026
Resolved 6 July 2026
Resolution: MIs witnessed proper testing of alarm panel
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2026
Resolved
Unless otherwise specified in this section, the Vessel Security Officer must keep records of the activities as set out in paragraph (b) of this section for at least 2 years and make them available to the Coast Guard upon request.VSO was unable to produce drill and exercise records prior to March 2026.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 July 2026
Resolved 6 July 2026
Resolution: MIs discussed proper proceduers of retaining security drills/exercises for a period of nlt 2 years
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 July 2024
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces.
Starboard exhaust stack automatic vent closure stuck in the closed position. Vessel will be given 14 days to correct issue since vents closures are are in the closed position.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 24 July 2024
Resolution: Received video and tech report validating repairs have been made and def was corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 March 2022
Resolved
Each towing vessel must have either a self priming pump, fixed fire main, and hozes and nozzles in accordance with paragraphs (a) through (d) of this section. Leaks were observed coming from the pump volute and the pump connection.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2022
Resolved 25 March 2022
Resolution: Received third party report showing repairs and testing completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 March 2022
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. The WTDs for for the E/R, Wheelhouse, and Forward Hold failed a water pressure test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 25 March 2022
Resolution: Received third party report showing repairs and testing completed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 June 2021
Resolved
During testing of high temp alarm on the port generator, it was identified that the alarm was inoperable. Replace high temp alarm to function as intended.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2021
Resolved 9 June 2021
Resolution: Alarm sensor was replaced and tested by Port Eng, alarm activated within design parameters (220F +/- 4F), all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 May 2020
Resolved
The owner/operator must ensure that the towing vessel is in compliance with the applicable laws and regulations at all times and any non-conformities and deficiencies are corrected in a timely manner. Towing vessel [name withheld] reported to USCG that it was stuck aground near Bulls Bay SC. Vessel must report to USCG once she is floating/underway and report any damage. Vessel is required to conduct in the presence of USCG a ISE prior to next trip.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2020
Resolved 27 May 2020
Resolution: Conducted ISE with satisfactory results.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 May 2020
Resolved
Closure devices must be provided for hull penetrations which open to the exterior of the vessel and which may allow water to enter the vessel; the watertight hatch to the fore-peak void is broken and cannot be properly secured. 46 CFR 144.320 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 May 2020
Resolved
Closure devices must be provided for hull penetrations which open to the exterior of the vessel and which may allow water to enter the vessel; the watertight door to the cargo hold is not properly adjusted to provide a seal. 46 CFR 144.320 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2020
Resolved
There must be an installed or portable bilge pump for emergency dewatering; the fixed bilge suction from the lazzarette is not performing adequately. 46 CFR 143.275
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2020
Resolved
Electrical systems must be designed and installed to minimize fire and shock hazards; there is a portable electric cord running in the overhead of the Master's stateroom to the television on the mess deck. 46 CFR 143.400
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2020
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 13 May 2020
Resolved
All smoke and fire detection systems must be inspected or tested; there is no record of smoke detector testing and two were found disabled. 46 CFR 142.240 (a) (8)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 May 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2020
Resolved
Individual circuit breakers on distribution panels must be labeled with a description of the loads they serve; the index card for the 220 volt panel in the engine room is not filled out. 46 CFR 143.400 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2020
Accommodation/Occupational Safety
Issued 23 February 1998
Resolved
REMOVE BLOCK OFF MSD VENTILATION PIPE.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Lifesaving
Issued 23 February 1998
Resolved
LIFERAFT NEEDS TO BE SERVICED.
Condition: Unknown
Due 23 February 1998
Resolved 9 March 1998
Fire Fighting
Issued 23 February 1998
Resolved
PROVIDE PROPER MARKINGS FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Engineering
Issued 23 February 1998
Resolved
PROVIDE OIL TRANSFER PROCEDURES FOR VESSEL.
Condition: Unknown
Due 23 February 1998
Resolved 9 March 1998