Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)65.0 ft × 24.4 ft × 9.1 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAMELIA, LA, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portYONGES ISLAND, SC
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 16 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton 67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 38 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 18 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
The fire detection system must provide visual alarms that identify the zone of origin of the fire. During operational testing of detectors in the fidley and galley, the visual alarm did not correctly identify the zone of origin of the activated detectors. Correct the fire detection system to ensure all zones are properly identified and the visual alarm accurately indicates the zone of origin.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2026
Resolved 6 July 2026
Resolution: MIs witnessed proper testing of alarm panel
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2026Resolved
Unless otherwise specified in this section, the Vessel Security Officer must keep records of the activities as set out in paragraph (b) of this section for at least 2 years and make them available to the Coast Guard upon request.VSO was unable to produce drill and exercise records prior to March 2026.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 July 2026
Resolved 6 July 2026
Resolution: MIs discussed proper proceduers of retaining security drills/exercises for a period of nlt 2 years
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 July 2024Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces.
Starboard exhaust stack automatic vent closure stuck in the closed position. Vessel will be given 14 days to correct issue since vents closures are are in the closed position.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 24 July 2024
Resolution: Received video and tech report validating repairs have been made and def was corrected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 March 2022Resolved
Each towing vessel must have either a self priming pump, fixed fire main, and hozes and nozzles in accordance with paragraphs (a) through (d) of this section. Leaks were observed coming from the pump volute and the pump connection.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2022
Resolved 25 March 2022
Resolution: Received third party report showing repairs and testing completed.
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. The WTDs for for the E/R, Wheelhouse, and Forward Hold failed a water pressure test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 25 March 2022
Resolution: Received third party report showing repairs and testing completed.
During testing of high temp alarm on the port generator, it was identified that the alarm was inoperable. Replace high temp alarm to function as intended.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2021
Resolved 9 June 2021
Resolution: Alarm sensor was replaced and tested by Port Eng, alarm activated within design parameters (220F +/- 4F), all sat.
The owner/operator must ensure that the towing vessel is in compliance with the applicable laws and regulations at all times and any non-conformities and deficiencies are corrected in a timely manner. Towing vessel [name withheld] reported to USCG that it was stuck aground near Bulls Bay SC. Vessel must report to USCG once she is floating/underway and report any damage. Vessel is required to conduct in the presence of USCG a ISE prior to next trip.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2020
Resolved 27 May 2020
Resolution: Conducted ISE with satisfactory results.
Closure devices must be provided for hull penetrations which open to the exterior of the vessel and which may allow water to enter the vessel; the watertight hatch to the fore-peak void is broken and cannot be properly secured. 46 CFR 144.320 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 May 2020Resolved
Closure devices must be provided for hull penetrations which open to the exterior of the vessel and which may allow water to enter the vessel; the watertight door to the cargo hold is not properly adjusted to provide a seal. 46 CFR 144.320 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2020Resolved
There must be an installed or portable bilge pump for emergency dewatering; the fixed bilge suction from the lazzarette is not performing adequately. 46 CFR 143.275
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2020Resolved
Electrical systems must be designed and installed to minimize fire and shock hazards; there is a portable electric cord running in the overhead of the Master's stateroom to the television on the mess deck. 46 CFR 143.400
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2020
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 13 May 2020Resolved
All smoke and fire detection systems must be inspected or tested; there is no record of smoke detector testing and two were found disabled. 46 CFR 142.240 (a) (8)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 May 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2020Resolved
Individual circuit breakers on distribution panels must be labeled with a description of the loads they serve; the index card for the 220 volt panel in the engine room is not filled out. 46 CFR 143.400 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2020
Accommodation/Occupational Safety
Issued 23 February 1998Resolved
REMOVE BLOCK OFF MSD VENTILATION PIPE.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Lifesaving
Issued 23 February 1998Resolved
LIFERAFT NEEDS TO BE SERVICED.
Condition: Unknown
Due 23 February 1998
Resolved 9 March 1998
Fire Fighting
Issued 23 February 1998Resolved
PROVIDE PROPER MARKINGS FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Engineering
Issued 23 February 1998Resolved
PROVIDE OIL TRANSFER PROCEDURES FOR VESSEL.
Condition: Unknown
Due 23 February 1998
Resolved 9 March 1998
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.