Records from 1998 to 2026. Most recent: inspection, 29 June 2026.
Inspection history · 128
29 June 2026
Re-Inspection · ACP COI Oversight · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8418401
21 February 2026
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8313892
20 February 2026
Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8308903
24 May 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8142561
13 April 2025
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8110932
4 December 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8042952
23 September 2024
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8041110
13 September 2024
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8001736
11 September 2024
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8041106
4 August 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8035433
21 May 2024
ACP Periodic Oversight · Administrative Inspection · Periodic Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7916119
12 July 2023
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7742245
3 May 2022
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7470828
14 April 2022
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7432784
24 March 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7418133
11 June 2021
Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7222498
25 May 2021
ACP COI Oversight · Re-Inspection · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7202020
20 November 2020
Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7099191
6 November 2020
ACP Drydock Oversight · Permit to Proceed
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7090988
2 November 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7137778
11 May 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6951213
11 April 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6938134
15 March 2020
Periodic Inspection · ACP Periodic Oversight
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6926749
28 February 2020
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6917332
15 July 2019
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6792181
19 March 2019
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6644982
16 May 2018
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6416493
2 April 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6383800
30 March 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6383099
11 December 2017
Periodic Inspection · ACP COI Oversight · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6322422
13 November 2017
MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6306013
18 October 2017
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6295308
19 September 2017
ISM SMC Audit
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6274322
10 August 2017
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6236796
7 April 2017
In-Service Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6119481
22 November 2016
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6046376
14 October 2016
ACP Periodic Oversight · Periodic Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6019690
27 June 2016
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5921932
14 June 2016
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5906759
16 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5855745
29 September 2015
ACP Annual Oversight · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5732058
1 August 2014
ACP Periodic Oversight
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4954178
27 May 2014
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4870056
17 July 2012
Special
Type not classified · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4381261
26 January 2012
Administrative Inspection · Liferaft Servicing
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4231858
6 September 2011
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4159288
26 August 2011
Periodic Inspection · ACP Handover Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4127362
26 August 2011
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4136431
19 July 2011
Underwater Inspection in lieu of Drydock · Examination of Repairs · Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4086677
21 February 2011
Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3949423
20 February 2011
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3954693
24 January 2011
Administrative Inspection · In-Service Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3932341
11 October 2010
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3954704
2 October 2010
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3952865
25 September 2010
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3945433
21 September 2010
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3855346
21 September 2010
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3945426
9 March 2010
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3693376
1 March 2010
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3688936
24 February 2010
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3685373
16 February 2010
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3684532
22 January 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3668031
2 July 2009
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3521313
2 April 2009
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3447377
5 July 2008
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3257951
2 July 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3271141
27 June 2008
Drydock Exam · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3249621
14 April 2008
In-Service Inspection · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3185149
29 February 2008
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3159427
2 November 2007
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3091988
19 July 2007
Administrative Inspection · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3011921
12 April 2007
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2906633
11 August 2006
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2743428
1 August 2006
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2733531
31 July 2006
Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2703115
27 June 2006
Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2699393
12 April 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2622888
13 February 2006
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2583885
6 February 2006
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2686411
5 October 2005
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2508064
6 September 2005
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2446467
26 May 2005
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2349972
12 May 2005
In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2355930
12 October 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2219360
16 September 2004
Administrative Inspection
Administrative · Activities Europe · Activity 2291887
31 July 2004
MTSA/ISPS Verification · Internal Structural Exam · Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2215823
23 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2108083
9 April 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2040648
20 March 2004
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2092578
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976351
16 December 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1965450
9 August 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1900701
27 June 2003
COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1779552
10 March 2003
Administrative Inspection
Administrative · Activities Europe · Activity 1755044
9 March 2003
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1754590
7 March 2003
Type not recorded
No type recorded · Activities Europe · Activity 1758416
11 February 2003
Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1743134
3 February 2003
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1752895
30 July 2002
Annual Inspection · Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1664745
27 April 2002
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1609960
9 April 2002
In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1602882
20 February 2002
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1487899
8 February 2002
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1485095
29 January 2002
Permit to Proceed
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1482075
28 January 2002
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1490686
25 October 2001
Damage Survey
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1366641
3 July 2001
COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1362324
12 April 2001
Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1062268
7 March 2001
Damage Survey
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1362038
21 February 2001
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 58133
12 February 2001
Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 81388
2 February 2001
Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 825172
3 January 2001
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 517003
4 October 2000
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 823449
29 August 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 28409
29 August 2000
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 43282
19 August 2000
Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1365932
28 June 2000
Re-Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1361662
26 May 2000
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 111127
23 May 2000
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 39411
22 March 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 513661
5 January 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 96796
15 December 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 812940
3 November 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 799661
2 November 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 140555
23 July 1999
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1402981
1 July 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1129462
1 April 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 788883
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 June 2026
No resolution recorded
Internal combustion engines of 2,250 kW and above or having cylinders of more than 300 mm bore shall be provided with crankcase oil mist detectors. Oil mist detectors found INOP on Aux. Engines 4 and 5. Complete repairs within 30 days.
74SOLAS(20) II-1/47.2
Action required: 50 - Rectify deficiencies w/in 30 days
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 June 2026
No resolution recorded
The purpose of this regulation is to suppress and swiftly extinguish a fire in the space of origin, except for paragraph 1.2... Fire extinguishing appliances shall be readily available. Foam analysis report is invalid. Submit report within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 24 May 2025
Resolved
If a ship is fitted with marine evacuation systems (MES), drills shall include exercising of the procedures for the deployment of such a system up to the point immediately preceding actual deployment of the system. This aspect of drills should be augmented by regular instruction using the on-board training aids required by regulation 35.4. Additionally every system party member shall, as far as practicable, be further trained by participation in a full deployment of a similar system into water, either on board a ship or ashore, at intervals of not longer than two years, but in no case longer than three years. This training can be associated with the deployments required by regulation 20.8.2. There is clear evidence that servicing of the MES is occurring on the rotational basis required by 8.2 and training videos and crew ability is present, however there is no implementation of SMS tracking or routine training to keep the crew current on the installed MES which could be problematic should a full MILDET be assigned on short notice.SOLAS III/19.3.3.8
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 August 2025
Resolution: Received evidence of from the vessels master that the following has been completed and implemented into the vessels SMS. PRO-0804-Policy update, Station Bill MES update, Training Muster Sheet for MES training, and orentaiton Training Video
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 May 2025
Resolved
Personal equipment shall consist of the following: An Axe with a handle provided with high-voltage insulation. The required on board FFE’s are missing the small personal equipment Axe as required by the FSS code for the fire-fighter's outfit.SOLAS II-2/10.1, FSS CODE 2.1.1.5
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 July 2025
Resolution: The vessel has acquired 4 handheld fire axes to fulfill the requirements for the 835 given to the vessel. Please see the attached picture of the items acquired. ABS has attended the vessel today and given the ok on the equipment acquired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. It was noted by the attending marine inspector that the port bow thruster is missing the gear box and is inoperable.SOLAS I/11(a)(Code 705 next drydock, schedueld for May 2026
Action required: 705 - Other - as specified
Resolved 2 August 2025
Resolution: Added to the next drydock scope and noted on Class documentation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 May 2025
Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out based on the guideline developed by the Organization and in a manner having due regard to ensuring reliability of such appliances. Reflective tape on the top of all lifeboats is faded and needs to be renewed.SOLAS III
LSA Code
Resolution MSC .481 (102)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2025
Resolved 5 August 2025
Resolution: Recieved and ABS Class reporting attesting to correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 May 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
During routine maintenance the ships force discovered a crack near the door seam on the lifeboat. Restore the lifeboat to original condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2025
Resolved 17 July 2025
Resolution: Recieved a service report from [name withheld] attesting to repairs and provided detailed repair images.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 11 June 2024
Resolved
Ships shall be maintained in complance with the structural, mechanical and electical requirements of a class society. Sewage piping in Emergency Diesel Generator Room 1-126-0 is wasted a dripping sewage on the Emergency Diesel Generator Air Compressor Motor Starter Controller. 74 SOLAS (2004)II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2024
Resolution: Wasted pipe cropped and repaired.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 25 May 2021
Resolved
Protection of openings and penetrations in fire-resisting divisions shall be kept in good order. Fire damper 2-54-1 on the C deck would not close. Repair fire damper prior to carrying cargo on C deck.
74SOLAS(20)II-2/14.2.1
Action required: 705 - Other - as specified
Resolved 3 June 2021
Lifesaving › Inflatable Liferafts › Capacity
Issued 16 March 2018
Resolved
Vessel has removed marine evacuation system (MES) to prevent damage during Panama Canal lock passages. Persons on board reduced to 100 until reinstallation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2018
Resolved 18 May 2018
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 October 2016
Resolved
Alarm system for OWS (Alpha Laval, Pure Bilge 2515) audible alarm is not exhibiting in ECR.
Due 18 November 2016
Resolved 22 November 2016
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 October 2016
Resolved
SOLAS 74/78 Chapter IV, Regulation 8, 9, and 10: Have current ship to station publication for DSC tests for respective areas.
Due 14 October 2016
Resolved 27 October 2016
Resolution: List V (List of Ship Stations and MMSIA) and List IV (List of Coast STations and Special Service Stations) received. Crew conducted DSC with acknolwedge received.
Engineering › Steering Gear System › Follow-up Assembly
Issued 14 June 2016
Resolved
Port steering system follow-up failure, circuit board failure with no spare onboard. Non-follow -up on port side is fully operational.
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 27 June 2016
Resolution: See class report.
Lifesaving › Lifeboat › Hull
Issued 23 July 2011
Resolved
Gouges were found in the forward and aft portion of the port side hull of the #1 lifeboat, caused by swinging into the davit cradle. Def write-up: Make proper repairs to hull of #1 lifeboat.
Action required: 705 - Other - as specified
Due 6 September 2011
Resolved 27 August 2011
Resolution: Technicians from Schat Harding concluded the gouges were superficial. Boat crew painted over the gouges.
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 23 July 2011
Resolved
Replace broken floodlight for rescue boat.
Action required: 705 - Other - as specified
Due 6 August 2011
Resolved 10 August 2011
Resolution: Floodlight was replaced.
Engineering › Steering Gear System › Linkage
Issued 21 February 2011
Resolved
Provide repair report from a certified technician and demonstrate proper operation of the steering gear in all modes.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2011
Resolution: Received repair report from [name withheld] attesting to repairs. Observed satisfactory test of steering in all modes.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 21 February 2011
Resolved
The Course Selector Repeater at the helm is not following the Gyro Compass.
Action required: 705 - Other - as specified
Due 3 April 2011
Resolved 31 March 2011
Resolution: Received Sperry Marine service report attesting to the repair of the Course Selector Repeater.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 21 September 2010
Resolved
Radar input to SVDR inoperative because of failed 3-cm radar that provides data.
Action required: 705 - Other - as specified
Resolved 2 October 2010
Resolution: Service report recieved from Sperry Marine Tech, repairs made to 3cm radar and S-VDR.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 21 September 2010
Resolved
Provide service report for annual tests to rescue boat launching gear.
Action required: 705 - Other - as specified
Due 21 October 2010
Resolved 11 October 2010
Resolution: Annual servicing completed by Schat-Harding representatives. Received service report.
Communications › Radio Communications › Satellite Communications Capability
Issued 24 February 2010
Resolved
Prove proper operation of newly installed GMDSS system to satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 9 March 2010
Resolution: Installed GMDSS system was satisfactorily repaired and tested by technical representative.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 19 February 2010
Resolved
The currently installed Nautica rescue boat on board is not SOLAS and Coast Guard approved. The Nautica rescue boat shall not be used until its SOLAS and Coast Guard approval is received and authorized. Lifeboat #1 is authorized for use as a resuce boat until an approved rescue boat is on board.
Action required: 705 - Other - as specified
Due 19 September 2010
Resolved 25 September 2010
Resolution: Vessel received their original rescue boat, which is SOLAS and Coast Guard approved.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 3 April 2009
Resolved
Replace master valve bypass valve on LP CO2 tank. Space restricted from personnel access without vessel master permission.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 May 2009
Resolved 21 April 2009
Resolution: Master valve bypass valve replaced with new valve and hardware.
Operations/Management › Drills/Instruction › Fire
Issued 27 June 2008
Resolved
Complete fire and abandon ship drills in presence of the USCG.
Condition: Unknown
Due 28 August 2008
Resolved 29 August 2008
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 27 June 2008
Resolved
Release and test life boats in presence of USCG.
Condition: Unknown
Due 28 August 2008
Resolved 29 August 2008
Stability › Watertight Integrity › General
Issued 27 June 2008
Resolved
Test operation of all Water tight doors from the bridge.
Due 28 August 2008
Resolved 29 August 2008
Engineering › Steam Turbine (propulsion) › Governor
Issued 27 June 2008
Resolved
Complete PSTP and Safety shut-downs of the generators and main propulsion.
Condition: Unknown
Due 28 August 2008
Resolved 29 August 2008
Lifesaving › Lifeboat › Hull
Issued 27 June 2008
Resolved
Repair holes found on the No. 2 Life boat. 1 hole is located where the original keel cooler foundation bolts mid-body, and the other is under the reinforcement plate. Examine all life boats and the rescue boat.
Condition: Improper/Lack of Maintenance
Due 2 October 2008
Resolved 8 September 2008
Construction/Loadline › Hull › Hull Plating
Issued 12 April 2007
Resolved
Re-submitted requirement to reflect new due date. Vessel sustained damage to bulbous bow, damage was inspected, NDT and hose tested at time of damage. Damage was reinspected during UWILD (27Jun2006) and found no further propagation or evidence of leaking. Ships force conducts quarterly inspection of damage. This item will be repaired no later than at next dry-docking (27JUN2008).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 1 August 2008
Engineering › Compressed Air System (start air) › Valve
Issued 12 April 2007
Resolved
Prove proper operation of air rec'r relief valves.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 18 May 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 31 July 2006
Resolved
Crop and renew as original the #2 seawater pump discharge piping.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 13 April 2007
Resolution: ABS Surveyor in Guam witnessed sat repairs (11/17/2006) and notified USCG in MSD Saipan same day. Cleared administratively this date by sector Charleston
Engineering › Bilge Water Management System › Piping
Issued 31 July 2006
Resolved
Make permanent repairs to MDV 13.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 11 August 2006
Resolution: Received class report for rectification.
Construction/Loadline › Penetrations › Pipe Flange
Issued 31 July 2006
Resolved
Crop and renew as original the coroded eductor piping located in the foam room.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 11 August 2006
Resolution: Received class report for rectification.
Construction/Loadline › Hull › Hull Plating
Issued 27 June 2006
Resolved
Previous damage to bulbous bow was reexamined during UWILD. Repairs are to be made as original.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 13 April 2007
Construction/Loadline › Hull › Hull Plating
Issued 27 June 2006
Resolved
Conduct internal structural examination to port and starboard Deep Tank DFM tanks # 8-32-2 and 8-32-1 and conduct repairs as required by attending CG inspector.
Action required: 705 - Other - as specified
Due 31 July 2006
Resolved 31 July 2006
Construction/Loadline › Hull › Weld
Issued 27 June 2006
Resolved
Conduct repairs to pitted areas in way of engine room oily water separating tank and cargo hold oily water separating tank.
Action required: 705 - Other - as specified
Due 31 July 2006
Resolved 31 July 2006
Engineering › Freshwater Generation System › Piping
Issued 6 September 2005
Resolved
Found flex air and water hoses permanently mounted to potable water tanks and evap chemical tank. Remove flex hoses and install hard piping.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 October 2005
Resolved 4 October 2005
Resolution: Inspected new hard pipe installation for both systems.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 September 2005
Resolved
Found oxygen and acetylene tanks not in racks under the bridge wing. Remove or install proper storage racks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 October 2005
Resolved 4 October 2005
Resolution: Inspected newly installed tank storage racks.
Lifesaving › Inflatable Liferafts › Markings
Issued 6 September 2005
Resolved
Found worn operating instructions at life rafts stations. Install legible instructions.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 October 2005
Resolved 4 October 2005
Resolution: Inspected rehabed operating instruction.
Construction/Loadline › Hull › Side Shell
Issued 16 September 2004
Resolved
Make permanent repairs to puncture in stern at frame 6-139-0 and monitor affected void space by daily inspections until such repairs are made.
Condition: Damaged By Earlier Event
Due 17 October 2004
Resolved 19 October 2004
Electrical › Electrical Distribution System (emergency)
Issued 27 June 2003
Resolved
RENEW FREQUENCY METER ON EMERGENCY GENERATOR SWITCHBOARD AS PER 46 CFR 111.30-29 (g) (4). LEGACY COMPONENT DESC: Switchboard
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 September 2003
Resolved 7 July 2003
Resolution: Received email with pictures of newly installed frequency meter.
Fire Fighting › Emergency Fire Pumps
Issued 10 March 2003
Resolved
Bearings failed in emergency fire pump. Vessel has a scheduled maintenance period during next US port call. Repairs are to be completed prior to departure form the scheduled maintenance period.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 14 April 2003
Resolved 27 June 2003
Resolution: VESSEL RENEWED BEARINGS IN EMERGENCY FIRE PUMP. CONDUCTED HOSE TEST AND PRESSURE TEST OF EMER FIRE PUMP.
Engineering
Issued 7 March 2001
Resolved
Make permanent repairs to the hydraulic servo valve on the starboard gas turbine engine.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Fire Fighting
Issued 28 June 2000
Resolved
PROVE PROPER OPERATION OF SMOKE DETECTOR IN ENGINEER'S STORE ROOM.
Condition: Unknown
Due 28 August 2000
Resolved 21 August 2000
Lifesaving
Issued 28 June 2000
Resolved
PROVE PROPER OPERATION OF #4 LIFEBOAT STARTING SYSTEM TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 30 August 2000
Resolved 30 August 2000
Lifesaving
Issued 28 June 2000
Resolved
PROVIDE LINE AS REQUIRED BY 46CFR199.170
Condition: Unknown
Due 15 September 2000
Resolved 12 September 2000
Engineering
Issued 28 June 2000
Resolved
PROVE PROPER OPERATION OF ALL BOILERS AND ASSOCIATED AUTOMATION TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 28 August 2000
Resolved 21 August 2000
Electrical
Issued 28 June 2000
Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR AUTO START SYSTEM.
Condition: Unknown
Due 28 August 2000
Resolved 21 August 2000
Electrical
Issued 3 November 1999
Resolved
PROVE PROPER AUTO START UP AND LOAD UP OF EMERGENCY GENERATOR PRIOR TO LEAVING THE PORT OF HAMPTON ROADS.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999