MAURY USCG vessel records Sign in
← All vessels

MICHAEL UHL

MICHAEL UHL is a 1972 unclassified. The Coast Guard has recorded 49 inspections since 1981, most recently in July 2022, along with 37 deficiencies — 3 with no resolution recorded — and 1 operational control, 1 with no removal date recorded.

Records from 1981 to 2022. Most recent: inspection, 19 July 2022.

Built
1972
Last inspected
19 July 2022
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

Flag
UNITED STATES
366639220, 366760390, 369169000 (licence lapsed)
Maury page id
psix-47372

Inspections, by type

…with no type recorded15
…past their stated due date1
Years with a record 25 calendar years (1981–2022)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)86.5 ft × 24.0 ft × 7.1 ft
Registered tonnagegross 82 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOFFSHORE TRAWLERS · BAYOU LA BATRE, AL, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORRO BAY, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 September 2025 · expires 30 September 2026
Service, as the file records itUnclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WXARMMSI 369169000 · expired · compulsorily equipped · granted 3 July 2012, cancelled 17 September 2022
WCY8394MMSI 366760390 · expired · voluntarily equipped · granted 20 January 1999, cancelled 28 March 2009 · licensed under a name not among this hull’s recorded names (not shown)
WAO6871MMSI not assigned · expired · voluntarily equipped · granted 21 June 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
WCM5280MMSI 366639220 · expired · voluntarily equipped · granted 30 August 1994, cancelled 30 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KAIMI Commercial Fishing Vessel · MISLE 178899 · 27 October 1992 · activity 131054KINGFISHER Commercial Fishing Vessel · MISLE 273314 · 27 October 1992 · activity 131054

Inspection history · 49

19 July 2022 In-Service Inspection · Hull Examination · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7518496
27 September 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6822616
25 September 2019 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6821193
17 June 2019 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6716383
15 November 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6307543
20 September 2010 Excursion Permit
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3853488
11 February 2010 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3679167
6 January 2010 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3651431
14 December 2009 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3650282
28 July 2009 Inclining Experiment
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3557273
25 March 2009 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3439858
31 July 2008 Internal Structural Exam · Drydock Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3274818
11 April 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3181594
18 January 2007 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2849394
10 February 2006 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2583002
23 May 2005 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2366875
19 May 2005 Liferaft Servicing
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2362802
31 January 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2287833
2 December 2004 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2235570
2 April 2004 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2036203
11 July 2003 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1843231
14 April 2003 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1773371
17 October 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1691691
18 January 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1479888
6 February 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1361953
5 January 2001 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1056798
30 October 2000 Damage Survey · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1056800
25 October 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 182369
25 October 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 222318
25 October 2000 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1055256
22 September 2000 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1470309
9 March 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1451521
2 August 1999 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 774245
2 July 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1464861
11 January 1999 Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1411750
7 October 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1413424
6 August 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1470733
23 February 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 663506
24 November 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 101545
27 October 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 131054
28 May 1987 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1333329
13 March 1987 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1015205
19 February 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004978
18 February 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299624
13 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289319
10 February 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1283392
7 February 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277776
16 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275513
1 May 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272234

Deficiency record · 37

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 September 2019 No resolution recorded
Prior to conducting towing, demonstrate compliance with 46 CFR subchapter M.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 17 June 2019 No resolution recorded
Crop and renew wasted door coaming on engine room and house water tight doors.
Action required: 60 - Rectify deficiencies prior to movement
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 17 June 2019 No resolution recorded
Provide 30X30 mesh screens for port side forward fuel tank vent and starboard aft vent.
Action required: 60 - Rectify deficiencies prior to movement
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 11 February 2010 Resolved
Prior to operating beyond 200NM, all licensed personnel must provide proper STCW certificates.
Action required: 705 - Other - as specified
Resolved 11 March 2010
Construction/Loadline › Markings › Load Line Mark
Issued 11 February 2010 Resolved
Provide load line certficate IAW 46 CFR 42.03-5. Vessel restricted to domestic voyages only.
Action required: 705 - Other - as specified
Resolved 11 March 2010
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 6 January 2010 Resolved
Provide blanks to fill holes in distribution panel A-1.
Condition: Unknown
Due 3 February 2010
Resolved 8 January 2010
Resolution: Installed blanks to fill holes.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 January 2010 Resolved
Provide updated light list.
Due 6 February 2010
Resolved 8 January 2010
Resolution: Provided new light list.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 January 2010 Resolved
Provide retro-reflective tape on liferings.
Due 6 February 2010
Resolved 8 January 2010
Resolution: Installed retro reflective tape on life rings.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 6 January 2010 Resolved
Provide lagging on turbine side of MDE turbo's.
Condition: Unknown
Due 6 February 2010
Resolved 8 January 2010
Resolution: Installed lagging on both turbo.
Communications › Radio Communications › EPIRB
Issued 6 January 2010 Resolved
Provide new NOAA decal for epirb and place on epirb verses on epirb cover.
Condition: Improper Installation
Due 6 February 2010
Resolved 8 January 2010
Resolution: Installed NOAA decal on epirb.
Communications › Public Address System › Loudspeaker
Issued 6 January 2010 Resolved
Provide loudspeaker for public address system in berthing area.
Condition: Unknown
Due 6 February 2010
Resolved 8 January 2010
Resolution: Installed speaker in berthing area.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 April 2009 Resolved
Provide valid radio operators permit
Action required: 705 - Other - as specified
Due 1 June 2009
Resolved 1 June 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 9 April 2009 Resolved
Provide valid radio safet telephony radio safety cert
Action required: 705 - Other - as specified
Due 1 June 2009
Resolved 9 June 2009
Engineering › Compressed Air System (control) › Valve
Issued 25 March 2009 Resolved
Conduct test of safety relief valve for air receiver located in E/R
Action required: 705 - Other - as specified
Due 1 June 2009
Resolved 11 March 2010
Resolution: This deficiency has been converted to a special note as o/o has no intentions of installing a replacement compressor in the near future.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 April 2008 Resolved
Rewire galley fan; remove orange extension cord; relocate electrical receptacle box.
Due 11 May 2008
Resolved 19 June 2008
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 11 April 2008 Resolved
Replace fire pump pressure gauge; current gauge inoperable.
Due 11 May 2008
Resolved 19 June 2008
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 11 April 2008 Resolved
Relocate O2 bottle adjacent to exhaust stack.
Action required: 705 - Other - as specified
Due 11 May 2008
Resolved 11 April 2008
Communications › Radio Communications › EPIRB
Issued 11 April 2008 Resolved
Replace expired EPIRB hydrostatic release.
Due 11 May 2008
Resolved 11 April 2008
Stability › Watertight Integrity › General
Issued 11 April 2008 Resolved
Install captive chain for E/R hatch.
Action required: 705 - Other - as specified
Due 11 May 2008
Resolved 11 April 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 January 2007 Resolved
Mark 01 ring lifebuoy with vessel name.
Action required: 705 - Other - as specified
Due 18 February 2007
Resolved 19 January 2007
Resolution: Vessel name was marked on ring lifebuoy.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 January 2007 Resolved
Re-affix retro-reflective material (Type 1) on 02 ring lifebuoys.
Action required: 705 - Other - as specified
Due 18 February 2007
Resolved 19 January 2007
Resolution: 02 ring lifebuoys provided with retro-reflective material.
Navigation › Piloting/Steering › Marine Charts
Issued 18 January 2007 Resolved
Provide currently correct charts, Coast Pilot, CG Light List, tide tables, and tidal current tables for areas vessel transits.
Action required: 705 - Other - as specified
Due 18 February 2007
Resolved 9 February 2007
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 18 January 2007 Resolved
Provide 30 x 30 mesh flame screen on day tank fuel vent.
Action required: 705 - Other - as specified
Due 18 February 2007
Resolved 9 February 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 January 2007 Resolved
Use, terminate, or remove dead end wires under helm.
Action required: 705 - Other - as specified
Due 18 February 2007
Resolved 19 January 2007
Resolution: Dead end wires under helm were removed and/or properly terminated.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 January 2007 Resolved
Repair inoperable port navigation light prior to getting vessel underway at night or reduced visability.
Action required: 705 - Other - as specified
Due 18 February 2007
Resolved 19 January 2007
Resolution: Port navigation light repaired and operating properly.
Lifesaving › Rescue Boat › Boarding Ladder
Issued 18 January 2007 Resolved
Provide rescue ladder for recovery of man overboard.
Action required: 705 - Other - as specified
Due 18 February 2007
Resolved 19 January 2007
Resolution: Rescue ladder provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 May 2005 Resolved
Lanyard for waterlight too long and attached to ring buoy by eye splice. Other ring buoy onboard had correct configuration for waterlight. Vsl crew mbr removed additional waterlight.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 23 May 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 April 2003 Resolved
Prove proper operation of installed high water bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2003
Resolved 14 April 2003
Resolution: Proved proper operation of installed high water bilge alarm.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 14 April 2003 Resolved
Mark lifejackets IAW 46CFR185.604.
Due 14 May 2003
Resolved 14 April 2003
Resolution: Marked lifejackets IAW 46CFR185.604.
Stability › Unintentional Flooding
Issued 18 January 2002 Resolved
Excessive water in steering space. 10inch + of water in steering space, bilge high level alarm float ball was extended to the max. Possible source of leak is starboard side ballast tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2002
Resolved 23 January 2002
Resolution: Repaired top of bulkhead on starboard side ballast tank. Repaired through bulkhead longitudinal on starboard side bottom shell.
Engineering › Bilge Water Management System
Issued 18 January 2002 Resolved
Metalic bilge piping in steering space was wasted. Was unable to completely dewater space, pump lost prime due to pin hole leaks on piping. CG 835 to replace bilge piping in steering space and asses remaining piping and replace as needed. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2002
Resolved 23 January 2002
Resolution: Conducted re-inspection, bilge piping in steering space was wasted all the way through. Replaced piping and footing, all satisfactory.
Engineering › Compressed Air System (start air)
Issued 18 January 2002 Resolved
Air receivers due for hydro test. Verbal CG835 via phone call, 18JAN02, requireing hydro test of air receivers. LEGACY COMPONENT DESC: Receiver/Bottle
Action required: 705 - Other - as specified
Due 18 February 2002
Resolved 23 January 2002
Resolution: Received fax report of results for air receiver tanks hydro stest, all satisfactory. Tanks tested to 325 PSI, relief valves opened at 185 PSI.
Fire Fighting
Issued 6 February 2001 Resolved
SEAL ON FIRE PUMP LEAKS.
Condition: Unknown
Due 13 February 2001
Resolved 9 February 2001
Lifesaving
Issued 6 February 2001 Resolved
Expired EPIRB hydrostatic release.
Condition: Unknown
Due 6 March 2001
Resolved 9 February 2001
Construction/Loadline
Issued 25 October 2000 Resolved
CONDUCT PRESSURE TEST OF DAMAGED FUEL TANK TO SATISFACTION OF COGNIZANT [name withheld] 08NOV00.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Construction/Loadline
Issued 9 March 2000 Resolved
THE FORWARD COMPARTMENT HAS A CRACKED STRINGER 2ND FROM THE BOW PORT SIDE THAT NEEDS TO BE CROPED AND RENEWED AND REINSPECTED BY THE COAST GUARD. THIS REPAIR IS TO BE COMPLETED BY 28MAR00.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Engineering
Issued 7 October 1998 Resolved
REPLACE EXISTING NON-APPROVED NON-METALLIC FUEL HOSES ASSEMBLIES WITH "APPROVED" PER SAE J1942-1 IN WAY OF FUEL OIL PURIFIER AND PORT MAIN ENGINEF/O FILTER. EXISTING HOSES ASSEMBLIES ARE NOT APPROVED FOR FUEL SERVICE.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.