MAURY USCG vessel records Sign in
← All vessels

ISLANDER

ISLANDER is a 1973 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1985, most recently in November 2025, along with 135 deficiencies and 2 casualty investigations between 2005 and 2008.

Records from 1985 to 2025. Most recent: inspection, 13 November 2025.

Built
1973
Last inspected
13 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP5466
Flag
UNITED STATES
368363690 (licence lapsed)
Maury page id
psix-47434

Inspections, by type

…with no type recorded5
Years with a record 36 calendar years (1985–2025)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)33.5 ft × 12.7 ft × 5.4 ft
Registered tonnagegross 13 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHOMPSON TRAWLER · TITUSVILLE, FL, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Regulatory (Subpart C or D), Net Ton
13 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5466MMSI 368363690 · cancelled · compulsorily equipped · granted 23 April 2024, cancelled 21 January 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT KG Towing Vessel · MISLE 114151 · 8 January 2005 · activity 2271327CTC 9536 Freight Barge · MISLE 425073 · 8 January 2005 · activity 2271327

Inspection history · 75

13 November 2025 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8268027
14 October 2025 COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8251540
25 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8194490
19 April 2024 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7896037
8 March 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7876134
28 September 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7800702
23 January 2023 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7628115
28 January 2022 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7386504
29 September 2021 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7322385
23 March 2021 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7162025
12 January 2021 Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7123440
9 November 2020 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7057761
8 January 2020 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6885543
27 August 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6796473
8 February 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6606297
12 February 2018 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6352692
20 September 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6269325
8 February 2017 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6081830
18 May 2016 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5884610
4 May 2016 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5866967
16 November 2015 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5763103
19 October 2015 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5749225
18 March 2014 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4818182
29 December 2011 Type not recorded
No type recorded · Station Ponce De Leon Inlet · USCG Southeast District (CGD-SE) · Activity 4215808
29 December 2011 Type not recorded
No type recorded · Station Ponce De Leon Inlet · USCG Southeast District (CGD-SE) · Activity 4215809
12 May 2009 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3473470
6 April 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3447958
17 June 2008 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3240511
10 June 2008 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3234547
10 June 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3235635
7 April 2008 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3180466
17 October 2007 Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3054570
16 April 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2907281
2 April 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2900090
22 March 2007 COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2892283
27 March 2006 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2611061
8 September 2005 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2486380
29 March 2005 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2322253
1 March 2005 Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2301632
8 January 2005 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2271327
27 April 2004 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2052910
23 September 2003 Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1912529
24 March 2003 Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1762576
28 March 2002 COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1599527
6 September 2001 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1436626
15 March 2001 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1060307
9 February 2001 Deficiency Check · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1058072
10 December 1999 COI Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 811758
6 December 1999 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 811756
19 May 1999 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 797160
7 April 1999 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1123826
9 March 1999 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 805127
2 March 1999 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1372537
9 March 1998 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1433321
26 September 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 780763
5 September 1997 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1390605
12 February 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1106245
6 January 1997 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1363905
8 January 1996 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1190360
6 September 1995 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1189865
10 January 1995 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 859676
31 January 1994 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 851880
25 August 1993 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1151091
21 June 1993 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 847121
19 November 1991 Re-Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1260088
5 February 1991 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1217808
1 June 1990 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 930813
25 January 1990 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1225492
24 January 1989 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 894195
6 December 1988 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1207824
9 February 1988 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1327590
10 June 1987 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1029535
26 March 1987 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1018779
13 February 1986 Credit Drydock
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 991643
19 February 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1287353

Deficiency record · 135

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 October 2025 Resolved
A vessel to which this subchapter (T) applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel does not have a valid Certificate of Inspection on board. Carriage of PAX is prohibited until a valid COI has been issued to the vessel. 46 CFR 176.100 (a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2025
Resolution: Completed a satisfactory COI inspection. Issued Temp COI.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 April 2024 Resolved
Provide a FCC Radio Station and Safety Certificate prior to operating more than 1000 feet from shore with passengers for hire.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 April 2024
Resolved 23 April 2024
Resolution: O/O provided license and safety inspection certificate information.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 27 January 2020 Resolved
The master shall conduct drills and give instructions as necessary to ensure that all crewmembers are familiar with their duties. Crewmember not familiar with man overboard drill.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2020
Resolved 3 February 2020
Resolution: Drill conducted satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 January 2020 Resolved
Each battery must be replaced during the annual inspection if the expiration date of battery has passed. Lifebuoy waterlight has expired battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2020
Resolved 3 February 2020
Resolution: Battery replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 January 2020 Resolved
Supervisory personnel must receive at least 60 minutes of training. EAP training not completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2020
Resolved 3 February 2020
Resolution: Training conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 February 2019 Resolved
A suitable marine type strainer meeting the requirements of engine manufacture must be fitted to fuel supply. Plastic petcocks found on both fuel water separators without plug to prevent leakage. Install new, metal type petcocks with plugs to meet manufacture requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Owner has provided pictures of metal fittings for both fuel water seperators.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2019 Resolved
Wire installation in engine compartment shall be installed with metal supports spaced not more than 24” apart. Existing wire installation found using plastic zip ties for mounting. Install proper metal type supports for permanent installation requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Owner has provided photos of metal type cable securing devices for cable run in engine compartment.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 February 2019 Resolved
Emergency instruction are to be mounted at operating station to cover actions to be taken in the event of fire and man overboard. Vessel emergency instructions are being stored in binder at operating station. Mount emergency instructions at operating station, visible to crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Owner has posted emergency instructions originally found in paperwork binder, at operating station for crew to see. Verification was done by photos provided by owner.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 8 February 2019 Resolved
Placards containing instructions for the donning and use of life jackets must be posted in a conspicuous place. Instructions currently being used are not model specific. Replace existing instructions to match actual model of life jackets onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Owner has printed out the correct brand and model of instructions for life jackects on board and posted in original location as previous instructions.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 February 2018 Resolved
Repair Bilge alarm IWO Port Side fuel tank room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2018
Resolved 13 February 2018
Resolution: Owner replaced faulty bilge alarm.
Stability › Watertight Integrity › General
Issued 8 February 2017 Resolved
Seal multiple penetrations in watertight bulkheads.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 22 February 2017
Resolution: Watertight Penetrations sealed to satisfaction of attending marine isnpector.
Electrical › Electric Supply System (service) › Cable
Issued 8 February 2017 Resolved
Cap dead end wires in starboard bow speaker.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 22 February 2017
Resolution: Speaker was reinstalled to the satisfaction of attending marine inspector.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 8 February 2017 Resolved
Replace 10 lifejackets on board that are no longer serviceable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: 10 lifejackets were replaced on board to the satisfaction of marine inspector.
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 February 2017 Resolved
Ensure there are lifejackets donning placards for each type of lifejacket on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Corrected on the spot.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 February 2017 Resolved
Emergency instructions were not correctly posted on board the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Deficiency corrected on the spot. Emergency instructions found and posted on board.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 February 2017 Resolved
Vessel was missing two nautical publications. Vessel had ordered them and recieved them before inspectors left the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Deficiency corrected on the spot.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 8 February 2017 Resolved
Install bonding wire from lip of fuel supply line to fuel tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Deficiency was corrected on the spot. Engineer installed bonding wire.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 4 May 2016 Resolved
Vessel is required to have 02 portable flashlights on board. Vessel had 01 inoperable on board. 01 brought onboard by master. 01 addtional required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 May 2016
Resolution: Received e-mail with pictures of new lights.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 May 2016 Resolved
Water light battery was expired and light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Corrected on the spot. Battery replaced and light tested.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 4 May 2016 Resolved
Vessel is required to have emergency instructions posted on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 4 May 2016
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 May 2016 Resolved
Remove or cap dead end wiring found in accomodation space forward on both port/stbd side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 May 2016
Resolution: Received e-mail with pictures of terminated/secured dead end wiring.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 March 2014 Resolved
Remove or repair RADAR system.
Due 18 April 2014
Resolved 25 March 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 March 2014 Resolved
Replace expired items in first aid kit.
Due 2 April 2014
Resolved 25 March 2014
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 March 2014 Resolved
Reseal watertight bulkhead thru-fitting.
Due 2 April 2014
Resolved 25 March 2014
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 18 March 2014 Resolved
Adjust stuffing boxes to eliminate excessive drip.
Due 2 April 2014
Resolved 25 March 2014
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 6 April 2009 Resolved
Fire bowl on the STARBOARD engine fuel filter is missing. Provide and properly install fire bowl.
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 27 May 2009
Resolution: Bowls were properly installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 6 April 2009 Resolved
AFT watertight bulkhead in the engine room is fractured at the bottom near the bilge. Perform repairs to as-new condition.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 27 May 2009
Resolution: Completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 April 2009 Resolved
Wire run in fuel tank compartment improperly installed. Effect repairs to properly secure wire run.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 27 May 2009
Resolution: Calbe clamps installed.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 April 2009 Resolved
Shaft packing on PORT and STARBOARD shafts is loose. Properly tighten or replace shaft packing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 27 May 2009
Resolution: Item cleared and re-issued.
Documentation › Markings/Placards › Warning Signs
Issued 6 April 2009 Resolved
Emergency procedures were not posted. Draft and post emergeny procedures.
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 27 May 2009
Resolution: Instruction posted.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 6 April 2009 Resolved
Tighten both (port and starboard) shaft packing and demonstrate proper operation to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2009
Resolved 23 October 2009
Resolution: Package adjusted...
Construction/Loadline › Structures › End Bulkhead
Issued 6 April 2009 Resolved
Replace broken/fractured vertical under deck support member, portside in the fuel tank compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 June 2009
Resolved 23 October 2009
Resolution: Vertical support repaired.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 April 2008 Resolved
Obtain proper amount of adult life jackets per the vessel's COI (40). Ensure all life jackets are stenciled w/ vessel's name and all retroreflective tape replaced as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2008
Resolution: Received receipt for 3 additional adult life jackets and statement from master attesting completion of requirement.
Fire Fighting › Fire Bucket › Quantity
Issued 7 April 2008 Resolved
Obtain 3 fire buckets per regulations w/ lanyard and labeled fire bucket.
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 8 April 2008
Resolution: Received statement from master attesting to completion of requirement.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 April 2008 Resolved
Have all fire-fighting equipment serviced & provide technician's report.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2008
Resolution: Received technicians report for all portable fire extinguishers and fixed CO2 system for engine compartment.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 April 2008 Resolved
Properly mount emergency broadcast placard and life jacket donning instructions.
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 8 April 2008
Resolution: Received statement from master attesting to completion of requirement.
Construction/Loadline › Hull › Keel
Issued 18 October 2007 Resolved
Renew keel back to good wood, remove at leat two keel bolts for C.G. inspection. Repair with compatable wood and to original deminsions.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2007
Resolution: Keel properly repaired, all sat.
Construction/Loadline › Hull › Transverse Frame
Issued 18 October 2007 Resolved
Repair or renew two transverse deck frames just aft of engine room hatches. Make proper joints for transverse frame at forward engine room hatch. Make all repairs IAW applicable rules and regulations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2007
Resolution: Transverse frames renewed.
Engineering › Bilge Water Management System › Valve
Issued 18 October 2007 Resolved
Install positive closing valves on all electric bilge pump overboard discharge ports, as close to the hull as possible. Bilge pump in fuel tank compartment does not work, repair or replace as needed.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2007
Resolution: All bilge pumps have new discharge valves installed, new pump installed in fuel tank space, all sat.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 18 October 2007 Resolved
Remove automatic float switch for engine room bilge pump. Repair/reseal forward engine room bulkhead at bottom center, so not to allow engine room water and oil mixture to migrate to forward compartment.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2007
Resolution: Automatic float switch is removed and bilge pump is on manual operation. Hole in bottom of forward engine room bulkhead was sealed to prevent bilge slops from entering the forward compartment.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 18 October 2007 Resolved
Properly secure all passenger deck and seats. Seating partitions on port and starboard are rotten. Renew as needed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 November 2007
Resolution: Seats secured properly, rotted partitions replaced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 October 2007 Resolved
Properly secure all bulkhead penetrations throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2007
Resolved 13 November 2007
Resolution: Penetrations properly secured.
Construction/Loadline › Hull › Transverse Frame
Issued 17 October 2007 Resolved
Properly secure #3 vertical under deck beam port side in way of fuel oil tank. Also secure the 4th under deck gusset starboard side in fuel oil tank compartment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2007
Resolution: Properly secured frame and gusset as required, all sat.
Engineering › Steering Gear System › Rudder
Issued 17 October 2007 Resolved
Repack both port and starboard rudder packings, and renew rudder bushings if needed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2007
Resolution: Both rudders were repacked, new bushings not required. All sat.
Construction/Loadline › Hull › Hull Plating
Issued 17 October 2007 Resolved
Remove bondo type faring material and use C.G. approved faring material.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2007
Resolution: Removed all unauthorized bondo and used epoxy based faring material. All Sat.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 March 2007 Resolved
All openings (shaft penetrations, cable runs, and fuel line penetrations) in the forward and aft bulkheads in the engine compartments are to be sealed and made vapor tight due to the installation of the fixed fire system in the engine compartment.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 16 April 2007
Resolution: Cleared.
Engineering › Fuel Oil Service System › Filter
Issued 22 March 2007 Resolved
Flame impingement bowls are to be installed under both main engine racor fuel filters.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 16 April 2007
Resolution: Cleared
Engineering › Fuel Oil Service System › Hose
Issued 22 March 2007 Resolved
The flexible fuel line connecting the starboard main engine to the copper fuel line is to be renewed due to excessive cracking and wear and shall not exceed 30" in length.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 16 April 2007
Resolution: Cleared
Engineering › Fuel Oil Service System › Filter
Issued 22 March 2007 Resolved
The racor fuel filter for the starboard main engine is to be properly mounted and secured.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 16 April 2007
Resolution: Cleared
Engineering › Sea-water System (primary cooling) › Valve
Issued 22 March 2007 Resolved
Double clamping of the fleixble hose to sea valve connections is to be provided as needed and where missing.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 16 April 2007
Resolution: Cleared
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 22 March 2007 Resolved
A means must be provided for securing the engine compartment ducts/cowls located on the port and starboard sides of the vessel due to the installation of a fixed fire extinguishing system.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 16 April 2007
Resolution: Cleared
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 22 March 2007 Resolved
The flexible fuel fill hose for the diesel storage tank is to be renewed.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 16 April 2007
Resolution: Cleared
Construction/Loadline › Structures › Machinery Space Opening
Issued 22 March 2007 Resolved
The hatches located on the main deck leading to the steering compartment, fuel tank compartment and below the operating station are to be provided with hinges and securing devices.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 16 April 2007
Resolution: Cleared
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 22 March 2007 Resolved
The diesel saturated carpet located IWO the diesel fuel fill fitting is to be removed.
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 22 March 2007
Resolution: Carpet was removed while onboard.
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 March 2006 Resolved
Vessel is to conduct fire and man overboard drills as required and properly document in training and drill log IAW 46 CFR 185.524(d).
Action required: 705 - Other - as specified
Due 27 April 2006
Resolved 15 June 2006
Resolution: Cleared
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 27 March 2006 Resolved
One additional crewmember is required to be certified for first aid/CPR.
Action required: 705 - Other - as specified
Due 27 April 2006
Resolved 15 June 2006
Resolution: Cleared
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 March 2006 Resolved
Machinery guards over port and starboard engines are to be installed IWO rotating machinery.
Action required: 705 - Other - as specified
Due 27 April 2006
Resolved 15 June 2006
Resolution: Cleared
Fire Fighting › Fire Bucket › Quantity
Issued 27 March 2006 Resolved
Provide (3) 2.5 gallon fire buckets properly marked w/lanyards attached.
Action required: 705 - Other - as specified
Due 27 April 2006
Resolved 15 June 2006
Resolution: Cleared
Engineering › Steering Gear System › Rudder Stock
Issued 27 March 2006 Resolved
Excessive leaks IWO port rudder post are to be stopped.
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 27 March 2006
Resolution: packing tightened
Engineering › Bilge Water Management System › Hose
Issued 8 September 2005 Resolved
Renew discharge hoses on submersible bilge pumps with suitable marine grade hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 7 October 2005
Resolution: Renewed with suitable hoses.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 September 2005 Resolved
Renew port engine exhaust elbow where wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 7 October 2005
Resolution: new elbow now installed.
Construction/Loadline › Structures › Machinery Space Opening
Issued 8 September 2005 Resolved
Renew under deck support for engine hatch where wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 7 October 2005
Resolution: supports renewed.
Construction/Loadline › Structures › Deck Plating
Issued 8 September 2005 Resolved
Renew plywood decking on starboard side IWO engine hatch where wasted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 7 October 2005
Resolution: decking renewed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 September 2005 Resolved
Renew handrails where pulled from deck on port side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 7 October 2005
Resolution: rails renewed.
Construction/Loadline › Penetrations › Pipe Flange
Issued 8 September 2005 Resolved
Make forward & aft bulkheads in the engine compartment vapor tight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 7 October 2005
Resolution: penetrations sealed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 September 2005 Resolved
Make windows throughout vessel weathertight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 7 October 2005
Resolution: gaskets in windows renewed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 September 2005 Resolved
Permanently mount port side aft bench seats where rotted out.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 7 October 2005
Resolution: mounted.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 1 March 2005 Resolved
Switches on bridge switchboard need labeled.
Condition: Unknown
Due 8 March 2005
Resolved 29 March 2005
Resolution: All switches on bridge switchboard have been labeled, including blanks.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 March 2005 Resolved
Starboard light needs repaired. Stern light needs replaced (very worn on sides, decreasing arc of visibility).
Condition: Improper/Lack of Maintenance
Due 8 March 2005
Resolved 29 March 2005
Resolution: Starboard light was repaired. New stern light was installed.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 1 March 2005 Resolved
Emergency shut-off valves for fuel pipes need labeled for purpose and direction.
Condition: Unknown
Due 8 March 2005
Resolved 29 March 2005
Resolution: Labels have been placed for purpose and direction on fuel shut-off valves.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 March 2005 Resolved
Wiring throughout vessel (under bridge console and in passenger area) needs housekeeping (dead-ended wires, improperly taped wires, butt connectors not shrink-wrapped, etc.).
Condition: Improper/Lack of Maintenance
Due 15 March 2005
Resolved 29 March 2005
Resolution: All wiring has been cleaned up throughout vessel.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 March 2005 Resolved
Lights in passenger area need proper guards or heavy-duty plastic covers.
Condition: Unknown
Due 8 March 2005
Resolved 29 March 2005
Resolution: Guards have been installed on lights in passenger area.
Construction/Loadline › Penetrations › Gasket
Issued 1 March 2005 Resolved
Small leak at starboard rudder post. Must provide repair proposal.
Condition: Unknown
Due 15 March 2005
Resolved 29 March 2005
Resolution: Starboard rudder post in steering compartment has been repaired. No leak was detected.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 1 March 2005 Resolved
Replace 6 adult & 2 child lifejackets. Damaged ones were destroyed in presence of CG inspectors.
Condition: Unknown
Due 8 March 2005
Resolved 29 March 2005
Resolution: Lifejackets have been replaced with new ones.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 March 2005 Resolved
Cleat on port side door to passenger area is loose. Must be removed or repaired at next drydock.
Condition: Improper/Lack of Maintenance
Due 1 October 2005
Resolved 29 March 2005
Resolution: Cleat was removed since it was not necessary.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 1 March 2005 Resolved
Alarms need repaired: audible bilge alarm for engine compartment and audible and visual alarms for port side fuel compartment.
Condition: Unknown
Due 15 March 2005
Resolved 29 March 2005
Resolution: Loose wire for fuel compartment alarms was re-connected. Switches for audible/visual bilge alarm in engine and steering spaces were replaced. All alarms now working properly.
Documentation › Logs/Records › Drug Test Records
Issued 1 March 2005 Resolved
Need proof of enrollment in random drug testing program for deckhand.
Condition: Unknown
Due 15 March 2005
Resolved 29 March 2005
Resolution: Proof of enrollment in drug testing program for deckhand was provided.
Navigation › Piloting/Steering
Issued 27 April 2004 Resolved
PROVIDE TIDE/TIDAL CURRENT TABLE LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 28 April 2004
Resolved 3 May 2004
Lifesaving › Hand Flares
Issued 27 April 2004 Resolved
PROVIDE THREE ORANGE DAY SIGNAL. LEGACY COMPONENT DESC: Quantity
Due 4 May 2004
Resolved 3 May 2004
Lifesaving › Lifejacket/PFD (General)
Issued 27 April 2004 Resolved
POST LISE JACKET DONNING PLACRD
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 27 April 2004 Resolved
PROVIDE CG APPROVED OR EQUIVALENT FIRST AID KIT.
Due 4 May 2004
Resolved 3 May 2004
Engineering › Bilge Water Management System
Issued 27 April 2004 Resolved
REPAIR E/R AND AFT HIGH LEVEL BILGE ALARM TO WORK INDEPENDENTLY IN THE VISIBLE POSITION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2004
Resolved 3 May 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 September 2003 Resolved
REPAIR NAVIGATION LIGHTS AND PROVE PROPER OPERATION
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2003
Resolved 1 October 2003
Engineering › Bilge Water Management System
Issued 23 September 2003 Resolved
REMOVE WATER FROM LAZARETTE
Due 1 October 2003
Resolved 1 October 2003
Engineering › Sea-water System (primary cooling) › Valve
Issued 23 September 2003 Resolved
REPLACE THROUGH HULL VALVES FOR BOTH ENGINE AND MSD SYSTEM
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 1 October 2003
Engineering › Fuel Oil Service System › Valve
Issued 23 September 2003 Resolved
REPLACE PORT FUEL EMERCENCY SHUT OFF VALVE
Due 1 October 2003
Resolved 1 October 2003
Electrical › Electric Supply System (service) › Cable
Issued 23 September 2003 Resolved
PERMANENT WIRE IN SHORE POWER CABLE AND MOUNT 110 VOLT RECEPTACLE OUTLET
Due 1 October 2003
Resolved 1 October 2003
Electrical
Issued 23 September 2003 Resolved
REPLACE STBD ENGINE ELECTRICAL COVER
Due 1 October 2003
Resolved 1 October 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 23 September 2003 Resolved
REPAIR MOUNT FOR FWD SEAT
Due 1 October 2003
Resolved 1 October 2003
Documentation › Certificates/Documents
Issued 24 March 2003 Resolved
POST STABILITY LETTER LEGACY COMPONENT DESC: Stability Letter
Due 1 May 2003
Resolved 2 April 2003
Fire Fighting
Issued 24 March 2003 Resolved
PROVIDE ANNUAL FIRE EXTINGUISHER SERVICE REPORT
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2003
Resolution: VESSEL INSTALL NEW FIRE EXTINGUISHERS
Fire Fighting
Issued 24 March 2003 Resolved
REPAIR SMOKE DETECTER IN E/R
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2003
Personnel › Training
Issued 24 March 2003 Resolved
PROVIDE FIRST AID/CPR CARDS FOR 50% OF CREW (TRAINING SCHEDULED FOR 17 MAY03) LEGACY COMPONENT DESC: First Aid/CPR
Due 24 April 2003
Resolved 2 April 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 March 2003 Resolved
REPAIR NAVIGATION LIGHTS
Due 28 March 2003
Resolved 25 March 2003
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 24 March 2003 Resolved
REPAIR TOILET( VOYAGES LIMITED TO 30 MINUTES UNTIL REPAIRED)
Due 1 April 2003
Resolved 25 March 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 March 2003 Resolved
REPLACE ITEMS IN FIRST AID KIT
Due 1 April 2003
Resolved 25 March 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 24 March 2003 Resolved
CLEAN ALL LIFE JACKETS AND REPLACE (10) BY 28 MAY03
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2003
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 24 March 2003 Resolved
REPLACE EXHAUST HOSE ON STBD ENGINE
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2003
Engineering › Diesel Engine (auxiliary)
Issued 24 March 2003 Resolved
ATTACH MACHINERY GUARDS ON BOTH ENGINE
Due 1 April 2003
Resolved 25 March 2003
Engineering › Bilge Water Management System
Issued 24 March 2003 Resolved
INSTALL VISIBLE AND AUDIBLE BILGE ALARM AT HELM
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2003
Electrical
Issued 24 March 2003 Resolved
PROPERLY TERMINATE ELECTRICAL WIRES ON VESSEL
Due 1 April 2003
Resolved 25 March 2003
Electrical
Issued 24 March 2003 Resolved
PERMANENT INSTALL ELECTRICAL CABLE FOR POWER INVERTER IN E/R
Due 1 April 2003
Resolved 25 March 2003
Construction/Loadline › Structures
Issued 24 March 2003 Resolved
SUBMIT REPAIR PROPOSAL FOR VESSEL WOOD ROOF
Due 30 June 2003
Resolved 4 April 2003
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 24 March 2003 Resolved
INSTALL SHORE POWER RECEPTACLES IN ELECTRICAL BOX
Due 1 April 2003
Resolved 1 April 2003
Pollution Prevention/Response › Prevention Equipment
Issued 28 March 2002 Resolved
Repair head - voyages limited to 30 minutes until repaired. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Damaged By Earlier Event
Due 2 April 2002
Resolved 29 March 2002
Fire Fighting › Fixed Fire Detection System
Issued 28 March 2002 Resolved
Replace battery in smoke detector in engine room and ensure proper operation. LEGACY COMPONENT DESC: Smoke Detectors
Due 2 April 2002
Resolved 4 April 2002
Resolution: Replaced smoke detector.
Lifesaving › Lifejacket/PFD (Type II)
Issued 28 March 2002 Resolved
Re-lable and replace retroreflective material on 29 life jackets. LEGACY COMPONENT DESC: Retroreflective Material
Due 2 April 2002
Resolved 4 April 2002
Operations/Management › Lifesaving
Issued 28 March 2002 Resolved
Vessel restricted to daylight hours until retro-reflective tape is replaced on 29 lifejackets.
Due 2 April 2002
Resolved 4 April 2002
Resolution: relabeled and replaced retro-reflective tape.
Construction/Loadline
Issued 6 September 2001 Resolved
INSTALL BILGE PUMP AND ALARM IN CENTER COMPARTMENT.
Condition: Unknown
Due 14 September 2001
Resolved 18 September 2001
Engineering
Issued 6 September 2001 Resolved
DEMO AND PROVE PROPER OPERATION OF THE EMERGENCY FUEL SHUT OFF VALVE.
Condition: Unknown
Due 14 September 2001
Resolved 18 September 2001
Lifesaving
Issued 6 September 2001 Resolved
INSTALL BRACKET FOR RING BUOY LIGHT
Condition: Unknown
Due 14 September 2001
Resolved 18 September 2001
Navigation
Issued 6 September 2001 Resolved
INSTALL RUDDER STOPS TO PREVENT HITTING IN AFT COMPARTMENT.
Condition: Unknown
Due 14 September 2001
Resolved 18 September 2001
Lifesaving
Issued 6 September 2001 Resolved
PROVIDE COAST GUARD APPROVAL FIRST AID KIT
Condition: Unknown
Due 14 September 2001
Resolved 18 September 2001
Construction/Loadline
Issued 6 September 2001 Resolved
PRIOR TO THE OPERATION WITH PASSENGERS FOR HIRE ENSURE WATERTIGHT INTEGRITYIN ALL COMPARTMENTS.
Condition: Unknown
Due 14 September 2001
Resolved 18 September 2001
Construction/Loadline
Issued 9 February 2001 Resolved
PROVIDE A VISUAL BILGE HIGH LEVEL ALARM IN ACCORDANCE WITH 46 CFR 182.53
Condition: Unknown
Due 9 February 2001
Resolved 9 February 2001
Lifesaving
Issued 9 February 2001 Resolved
PROVIDE AN ADDITIONAL 13 ADULT TYPE I PFD'S. UNTIL SUCH TIME TOTAL PERSONSALLOWED ON BOARD IS REDUCED TO 27 PERSONS.
Condition: Unknown
Due 14 February 2001
Resolved 21 February 2001
Lifesaving
Issued 9 February 2001 Resolved
PROVIDE RING BUOY LIGHT APPROVED IN ACCORDANCE WITH 161.010. VESSEL RESTRICTED TO DAYLIGHT OPERATION ONLY.
Condition: Unknown
Due 14 February 2001
Resolved 21 February 2001
Construction/Loadline
Issued 9 February 2001 Resolved
PROVIDE ELECTRIC BILGE PUMPS CAPABLE OF DISCHARGING 10 GPM (600 GPH) IN ACCORDANCE WITH 46 CFR 182.520
Condition: Unknown
Due 9 February 2001
Resolved 9 February 2001
Lifesaving
Issued 9 February 2001 Resolved
PROVIDE MEANS TO RECOVER A HELPLESS PERSON OVERBOARD.
Condition: Unknown
Due 9 February 2001
Resolved 9 February 2001
Navigation
Issued 6 December 1999 Resolved
COMPLETE PERMANENT REPAIRS TO STARBOARD RUDDER POST AT PACKING LOCK NUT WHERE EPOXY IS APPLIED.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Construction/Loadline
Issued 6 December 1999 Resolved
REPLACE WASTED WOOD AT ACCESS TO FUEL TANK COMPARTMENT HATCH (PORT SIDE)
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Construction/Loadline
Issued 6 December 1999 Resolved
REPAIR FRP WHERE DAMAGED PORTSIDE AT CHINE ABEAM PILOT HOUSE.
Condition: Unknown
Due 6 December 1999
Resolved 10 December 1999
Engineering
Issued 9 March 1999 Resolved
REPLACE NON COAST GUARD APPROVED FUEL HOSE ON PORT ENGINE WITH APPROVED TYPE. PROPER FLARE OR NIPPLE CONNECTION IS REQUIRED.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Engineering
Issued 2 March 1999 Resolved
PRIOR TO CARRYING PASSENGERS, REPLACE THE FLEXABLE FUEL HOSE CONNECTING METAL FUEL LINE TO FUEL PUMP ON PORT ENGINE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 March 1999
Resolved 11 March 1999
Engineering
Issued 2 March 1999 Resolved
REPLACE OR PROVE SUITABLE OPERATION OF DETERIATING EXHAUST ELBOW CONNECTINGRUBBER EXHAUST HOSE AFT OF PORT ENGINE MANIFOLD.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Lifesaving
Issued 2 March 1999 Resolved
REPLACE RETRO REFLECTICE TAPE ON 8 DESIGNATED LIFE PRESERVERS.
Condition: Unknown
Due 2 March 1999
Resolved 11 March 1999
Lifesaving
Issued 2 March 1999 Resolved
PERMANETLY ATTACH REQUIRED LANYARD TO WATER FLOAT LIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 March 1999
Resolved 11 March 1999
Lifesaving
Issued 2 March 1999 Resolved
ATTACH THE 60 RETIEVEL LINE TO THE RING LIFE BUOY.
Condition: Unknown
Due 2 March 1999
Resolved 11 March 1999
Construction/Loadline
Issued 2 March 1999 Resolved
REPLACE NON MARINE APPROVED WIRE CONNECTING THE BILGE PUMPS IN THE STEERINGCOMPARTMENT AND THE FORWARD COMPARTMENT WITH U/L APPROVED MARINE WIRE AND PROPER CONNECTIONS. _x001C_ _x001C_
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Lifesaving
Issued 9 March 1998 Resolved
REPLACE FADED AND LOOSE RETRO REFLECTIVE TAPE ON THE 20 NOTED ADULT PFD'S
Condition: Unknown
Due 10 March 1998
Resolved 17 March 1998
Navigation
Issued 5 September 1997 Resolved
CORRECT/LUBRICATE SEIZED LINKAGES IN STEERING CONTROL CHAIN LOCATED IN AFT LAZERETTE AS NECESSARY.
Condition: Unknown
Due 5 September 1997
Resolved 14 October 1997
Documentation
Issued 6 January 1997 Resolved
PROVIDE PROOF OF COMPLIANCE WITH 46 CFR PART 16, RANDOM DRUG TESTING OF EMPLOYEES.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Engineering
Issued 6 January 1997 Resolved
DOUBLE LOCK ENGINE THROTTLE CABLE CONNECTIONS AND REDUCTION CABLE CONNECTIONS AT GEAR BOX.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Navigation
Issued 6 January 1997 Resolved
DOUBLE LOCK NUT THE RUDDER CROSS BAR CONNECTION AT BOTH RUDDERS.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Documentation
Issued 21 June 1993 Resolved
PROVIDE A WRITTEN CHEMICAL TESTING PROGRAM IN ACCORDANCE WITH_x001C_ 46CFR PART 16.
Condition: Unknown
Due 5 July 1993
Resolved 15 July 1993

Casualty record · 2

8 January 2005Routine · role: Transiting Vicinity of Primary Subject · activity 2271327
10 June 2008Routine · role: Involved in a Marine Casualty · activity 3235635
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MANATEE (2005–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.