Documentation record
Registered dimensions (L × B × D)33.5 ft × 12.7 ft × 5.4 ft
Registered tonnagegross 13 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHOMPSON TRAWLER · TITUSVILLE, FL, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 15 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Regulatory (Subpart C or D), Net Ton
13 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
13 November 2025
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8268027
14 October 2025
COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8251540
25 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8194490
19 April 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7896037
8 March 2024
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7876134
28 September 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7800702
23 January 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7628115
28 January 2022
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7386504
29 September 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7322385
23 March 2021
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7162025
12 January 2021
Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7123440
9 November 2020
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7057761
8 January 2020
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6885543
27 August 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6796473
8 February 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6606297
12 February 2018
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6352692
20 September 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6269325
8 February 2017
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6081830
18 May 2016
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5884610
4 May 2016
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5866967
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 October 2025
Resolved
A vessel to which this subchapter (T) applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel does not have a valid Certificate of Inspection on board. Carriage of PAX is prohibited until a valid COI has been issued to the vessel. 46 CFR 176.100 (a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2025
Resolution: Completed a satisfactory COI inspection. Issued Temp COI.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 April 2024
Resolved
Provide a FCC Radio Station and Safety Certificate prior to operating more than 1000 feet from shore with passengers for hire.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 April 2024
Resolved 23 April 2024
Resolution: O/O provided license and safety inspection certificate information.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 27 January 2020
Resolved
The master shall conduct drills and give instructions as necessary to ensure that all crewmembers are familiar with their duties. Crewmember not familiar with man overboard drill.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2020
Resolved 3 February 2020
Resolution: Drill conducted satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 January 2020
Resolved
Each battery must be replaced during the annual inspection if the expiration date of battery has passed. Lifebuoy waterlight has expired battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2020
Resolved 3 February 2020
Resolution: Battery replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 January 2020
Resolved
Supervisory personnel must receive at least 60 minutes of training. EAP training not completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2020
Resolved 3 February 2020
Resolution: Training conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 February 2019
Resolved
A suitable marine type strainer meeting the requirements of engine manufacture must be fitted to fuel supply. Plastic petcocks found on both fuel water separators without plug to prevent leakage. Install new, metal type petcocks with plugs to meet manufacture requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Owner has provided pictures of metal fittings for both fuel water seperators.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2019
Resolved
Wire installation in engine compartment shall be installed with metal supports spaced not more than 24” apart. Existing wire installation found using plastic zip ties for mounting. Install proper metal type supports for permanent installation requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Owner has provided photos of metal type cable securing devices for cable run in engine compartment.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 February 2019
Resolved
Emergency instruction are to be mounted at operating station to cover actions to be taken in the event of fire and man overboard. Vessel emergency instructions are being stored in binder at operating station. Mount emergency instructions at operating station, visible to crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Owner has posted emergency instructions originally found in paperwork binder, at operating station for crew to see. Verification was done by photos provided by owner.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 8 February 2019
Resolved
Placards containing instructions for the donning and use of life jackets must be posted in a conspicuous place. Instructions currently being used are not model specific. Replace existing instructions to match actual model of life jackets onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2019
Resolved 6 March 2019
Resolution: Owner has printed out the correct brand and model of instructions for life jackects on board and posted in original location as previous instructions.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 February 2018
Resolved
Repair Bilge alarm IWO Port Side fuel tank room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2018
Resolved 13 February 2018
Resolution: Owner replaced faulty bilge alarm.
Stability › Watertight Integrity › General
Issued 8 February 2017
Resolved
Seal multiple penetrations in watertight bulkheads.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 22 February 2017
Resolution: Watertight Penetrations sealed to satisfaction of attending marine isnpector.
Electrical › Electric Supply System (service) › Cable
Issued 8 February 2017
Resolved
Cap dead end wires in starboard bow speaker.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 February 2017
Resolved 22 February 2017
Resolution: Speaker was reinstalled to the satisfaction of attending marine inspector.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 8 February 2017
Resolved
Replace 10 lifejackets on board that are no longer serviceable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: 10 lifejackets were replaced on board to the satisfaction of marine inspector.
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 February 2017
Resolved
Ensure there are lifejackets donning placards for each type of lifejacket on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Corrected on the spot.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 February 2017
Resolved
Emergency instructions were not correctly posted on board the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Deficiency corrected on the spot. Emergency instructions found and posted on board.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 February 2017
Resolved
Vessel was missing two nautical publications. Vessel had ordered them and recieved them before inspectors left the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Deficiency corrected on the spot.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 8 February 2017
Resolved
Install bonding wire from lip of fuel supply line to fuel tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 8 February 2017
Resolution: Deficiency was corrected on the spot. Engineer installed bonding wire.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 4 May 2016
Resolved
Vessel is required to have 02 portable flashlights on board. Vessel had 01 inoperable on board. 01 brought onboard by master. 01 addtional required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 May 2016
Resolution: Received e-mail with pictures of new lights.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 May 2016
Resolved
Water light battery was expired and light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Corrected on the spot. Battery replaced and light tested.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 4 May 2016
Resolved
Vessel is required to have emergency instructions posted on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 4 May 2016
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 May 2016
Resolved
Remove or cap dead end wiring found in accomodation space forward on both port/stbd side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 May 2016
Resolution: Received e-mail with pictures of terminated/secured dead end wiring.