Documentation record
Registered dimensions (L × B × D)61.4 ft × 21.1 ft × 8.3 ft
Registered tonnagegross 89 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLIED SHIPYARD INC · LAROSE, LA, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJACKSONVILLE, FL
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 7 April 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it89 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
3 June 2026
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8380716
26 August 2025
Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8188171
24 September 2024
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8001214
15 September 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7785182
3 August 2023
Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7759456
3 August 2023
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7759688
12 December 2022
COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7606259
13 July 2022
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7505911
20 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7434681
30 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7421335
2 July 2021
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7255073
20 August 2015
Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5221379
16 April 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5104531
22 September 2014
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4991727
12 April 2012
DAPI Audit · Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4274126
17 August 2011
DAPI Audit · Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4117203
10 October 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2797237
8 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2305957
12 January 2005
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2273584
11 January 2005
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2272623
8 January 2005
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2271327
1 November 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1703914
8 December 1999
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1511230
8 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 11801
8 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 224124
19 March 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 53937
4 February 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 149561
27 January 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 126421
16 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 4247
22 March 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 146600
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 3 June 2026
Resolved
The line throwing appliance must have: An auxiliary line that: Is at least 1,500 ft long, has a breaking strength of at least 9,000 lbs-force, and is, if synthetic, of dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light.
Vessel did not have auxiliary line.
46 CFR 141.385(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2026
Resolved 25 June 2026
Resolution: Purchased new line and provided photo to CG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 June 2026
Resolved
The following systems must be equipped with gauges at the machinery location: Main engine lubricating oil pressure and main engine RPM.
Port engine RPM gauge was not reading proper RPM.
46 CFR 143.230(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2026
Resolved 11 June 2026
Resolution: RPM guage repaired and reading.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions.
Head: junction box exposed and hole in light switch housing. Engine Rm.: Hole in bottom of transfer switch housing. 02 unapproved power strips, one in upper berthing and one in galley.
46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2026
Resolved 11 June 2026
Resolution: Covered junction box.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2026
Resolved
Unless otherwise specified, all lifesaving equipment must be approved by the Commandant under the approval series specified in each section.
Replace retro-reflective tape on both STBD and Port lifebuoys.
46 CFR 141.200(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2026
Resolved 11 June 2026
Resolution: Replaced retro on lifering.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 3 June 2026
Resolved
Each integral fuel tank must have a vent that connects to the highest point of the tank, discharges on a weather deck through a bend of 180 degrees, and is fitted with a 30-by-30-mesh corrosion-resistant flame screen.
Forward STBD goose-neck venting is missing a flame screen.
46 CFR 143.265(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2026
Resolved 11 June 2026
Resolution: Sewage tank, not fuel tank. No 30x30 mesh required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. STBD battery box in engine room is not secured. Grounding wire on radar is loose.
46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2026
Resolved 11 June 2026
Resolution: Battery box secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 3 June 2026
Resolved
Electrical conductors passing though watertight bulkheads must be installed so that the bulkhead remains watertight.
Watertight bulkhead between engine room and tool room has a penetration that is not properly sealed.
46 CFR 143.400(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2026
Resolved 11 June 2026
Resolution: Installed metal cover over junction box.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 3 June 2026
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment.
Stove, and stove splash guard needs securing as to not be easily moved.
46 CFR 140.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2026
Resolved 11 June 2026
Resolution: Secured galley stove and guard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 September 2023
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of 141.370 for specified areas where the vessel operates. Vessel did not have 12 visual distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2023
Resolution: Vessel purchased required visual distress signals.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 12 December 2022
Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies. This includes abandoning the vessel, recovering persons from the water, responding to onboard fires and flooding, or responding to other threats to life, property, or the environment. Vessel's crew was unable to satisfactorily demonstrate competence while conducting two fire drills.
705c - Prior to Operation
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 December 2022
Resolution: MIs witnessed satisfactory fire, abandon ship, and man overboard drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 December 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Steering rams were found to be loose at the attachment point of the rudder stock.
705c - Prior to Operation
Action required: 705 - Other - as specified
Resolved 14 December 2022
Resolution: MIs verified temproary repair on steering gear rams, permanent reapirs to be made by next dry dock.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 December 2022
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. Semi-portable fire extinguisher was secured to a permanently attached bracket.
50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2023
Resolved 14 December 2022
Resolution: MIs verified installment of permanently afixed bracket for 160-B semi portable extinguisher.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 December 2022
Resolved
If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move and must be either: (1) A flammable liquid storage cabinet that satisfies UL 1275 (incorporated by reference, see § 136.112 of this subchapter); or (2) A flammable liquid storage cabinet that satisfies FM Approvals Standard 6050 (incorporated by reference, see § 136.112 of this subchapter); or (3) Another suitable steel container that provides an equivalent level of protection. Vessel's paint locker was of an unapproved type and had multiple holes in the siding rendering it wasted.
50c
Action required: 10 - Deficiency Rectified
Due 12 January 2023
Resolved 14 December 2022
Resolution: Vessel to remove all flammable liquids from vessel
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 December 2022
Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. This includes machinery, deck machinery, towing gear, ladders, embarkation devices, cranes, portable tools, and safety equipment. Forward stairwell had 02 steps that were wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2023
Resolved 14 December 2022
Resolution: MIs verified repairs to the stairwell.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Circuit breaker panel on the bridge was missing a cover over exposed/missing breaker.
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 14 December 2022
Resolution: MIs verified breaker panel was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 December 2022
Resolved
At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. If more than one lifebuoy is carried, at least one must not have a lifeline attached. Both ring life buoys on board vessel had life lines attached.
10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 12 December 2022