Inspection history · 32
6 June 2026
In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8393162
5 June 2026
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8403117
28 April 2026
PSC A · COC-CVE Quarterly
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8357320
26 November 2025
COC-CVE Annual · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8273522
24 June 2025
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8166253
3 May 2025
PSC B · COC-CVE Quarterly
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8127787
26 November 2024
COC-CVE Annual · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8038160
4 May 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7923334
30 April 2024
COC-CVE Quarterly
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7903680
13 April 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7901828
17 March 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7889465
16 December 2023
PSC A · COC-CVE Annual · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7839180
17 July 2023
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7744381
8 July 2023
COC-CVE Quarterly · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7733755
18 January 2023
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7623067
17 December 2022
COC-CVE Annual · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7605015
10 September 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7557798
13 August 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7532220
24 June 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7485926
10 May 2022
PSC A · COC-CVE Annual · In-Service Inspection · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7446658
10 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6937879
2 April 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6934436
30 March 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6933346
21 July 2019
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6762847
23 May 2019
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6691365
9 May 2019
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6680533
24 April 2019
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6668647
14 April 2018
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6390052
22 April 2017
ISPS II Exam · COC-CVE Annual
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6126696
26 September 2016
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6010138
9 September 2016
In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5996542
23 April 2016
COC-CVE Annual · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5856792
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2026
Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Special consideration shall be given to the malfunctioning of: the hydraulic, pneumatic or electrical means for control in main propulsion machinery including controllable pitch propellers. However, the administration, having regard to overall safety considerations, may accept a partial reduction in propulsion capability from normal operation. Vessel reported a ground fault in both windings of port Propulsion Electric Motor (PEM)
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 November 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Outboard forward life raft davit was not immediately ready for use due to an electrical failure. Life boat number 5's engine could not be stopped utilizing the engine stop button. - 74 SOLAS 20/III 20.2
Action required: 15 - Rectify deficiencies by next port
Resolved 26 November 2025
Resolution: Vessel's crew was able to fix life raft davit and life boat 5's engine prior to the completion of the exam.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 November 2025
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. The loft and video game room on deck 9, MVZ 1, is classified as a category 8 space. PSCO observed unauthorized stowage of approx. 30 cardboard boxes and other items. - 74 SOLAS 97 II-2/26.2.2
Action required: 15 - Rectify deficiencies by next port
Resolved 26 November 2025
Resolution: Vessel's crew removed items from both rooms and properly stowed them, prior to the completion of the exam.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 November 2025
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures, designed to re-open upon contacting an object in its path shall re-open sufficiently to allow a clear passage of at least 0.75 m but no more than 1 m. Sliding fire door 3.4.028 to atrium was not re-opening after contact was made.- 74 SOLAS 97 II-2/30.4.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 November 2025
Resolution: Vessel's crew was able to successfully repair crash bar on this sliding fire door prior to the completion of the exam.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 3 May 2025
Resolved
Where "A" class divisions are penetrated for the passage of electric cables, pipes, trunks, ducts, etc., or for girders, beams or other structural members, arrangements shall be made to ensure that the fire resistance is not impaired. Piping going through bulkhead in "Cascade Room" on deck 09 has gaps in SFP. 74 SOLAS 97 II-2/18.1.1 (16ac)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2025
Resolution: RO attested to rectification
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 3 May 2025
Resolved
Where "A" class divisions are penetrated for the passage of electric cables, pipes, trunks, ducts, etc., or for the girders, beams or other structural members, arrangements shall be made to ensure that the fire resistance is not impaired. Pipe going through A-60 is made of non-metallic material and is free moving with in the penetration in way of fire door A.1.098. 74 SOLAS 97 II-2/18.1.1 (16ac)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2025
Resolution: RO attested to rectification
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 May 2025
Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. There has been a curtain added to the "Kings Room" on deck 5 turning it into a space within a space. No secondary escape route or audible alarm was in place. 74 Solas 97 II-2/28.1.2 (16ac)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2025
Resolution: RO attested to rectification
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 November 2024
Resolved
The purpose of this requlation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Fire nozzle was found defective during drill.
74 SOLAS 97 II-2/14.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2024
Resolution: The defective fire nozzle was replaced with a new one and tested under pressure with satisfactory result.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 November 2024
Resolved
For determining the appropriate fire integrity standards tobe applied spaces are classified according to the fire risk. Gangway corridors on Decks 2 and 3, prot and starboard sides, are being imporperly used for storage; not meeting the fire integrity requirements of the designated space.
74 SOLAS 97 II-2/14.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2024
Resolution: Apart from the security equipment which are now secured at side to clear the space for safe entry, all other house keeping items were removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 November 2024
Resolved
Furniture shall not be permitted in the passenger and crew corridors forming escape routes in cabin areas. PSCO's observed a bench on Deck 6, Zone 1, stairwell not secured.
74 SOLAS 97 II-2/41-2.4.10
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2024
Resolution: The above bench is now secured to the wall.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 November 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Section valve indication on the SMCS does not match the correct indication on the fire detection system.
74 SOLAS 01 II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 December 2024
Resolved 4 January 2025
Resolution: Maintenance/adjustments carried out so that SMCS now matches fire detection system.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 November 2024
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than the power operated watertight doors and those which are normally locked shall satisfy the following requirements. A door designed to re-open not more than 1 m from the point of contact. All sliding fire doors do not immediately stop and re-open upon actuation of the crash bar.
74 SOLAS 97 II-2/9.4.1.1.5.11
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 December 2024
Resolved 19 January 2025
Resolution: Received class documentation showing satisfactory maintenance and repair of fire doors followed by testing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2024
Resolved
ELECTRICAL CONDITIONS SHALL BE SUCH THAT: THE SAFETY OF PASSENGERS, CREW, AND SHIP FROM ELECTRICAL HAZARDS WIL BE ENSURED. PSCO OBSERVED EXPOSED WIRING ON ELECTRICAL BOX ABOVE DOOR A-053.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 April 2024
Resolved 30 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 April 2024
Resolved
THE CONSTRUCTION OF ALL DOORS AND DOOR FRAMES IN "A" CLASS DIVISIONS, WITH THE MEANS OF SECURING THEM WHEN CLOSED, SHALL PROVIDE RESISTANCE TO FIRE AS WELL AS TO THE PASSAGE OF SMOKE AND FLAME, AS FAR AS PRACTICABLE, EQUIVALENT TO THAT OF THE BULKHEADS IN WHICH THE DOORS ARE SITUATED. SUCH DOORS AND DOOR FRAMES SHALL BE CONSTRUCTED OF STEEL OR OTHER EQUIVALENT MATERIAL. PSCO OBSERVED DOOR A041-A053 IN FIRE ZONE 4 WAS NOT SECURING AS INTENDED.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 April 2024
Resolved 30 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 December 2023
Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. Fire doors 6.3.018, 7.3.020 & 7.4.016 gaskets were deteriorated rendering the fire doors unable to seal appropriately. 74 SOLAS (97 CONS) II-2/30.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2024
Resolved 5 January 2024
Resolution: Class report reviewed and found satisfactory.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 8 July 2023
Resolved
Hydraulic power-operated steering gear shall be provided with a low-level alarm for each hydraulic fluid reservoir to give the earliest practicable indication of hydraulic fluid leakage. Audible and visual alarms shall be given on the navigation bridge and in the machinery space where they can be readily observed. After testing low hydrualic level at both port and starboard steering rooms, audible and visual low level alarms inoperable at both engine control room and navigation bridge. Steering alarm panel at engine control room and navigation bridge is not receiving alarm signal.
74SOLAS(04)II-1/29.12.2
Deficiency code was initially a code 17ac, but then updated to a 10c, as it was corrected on the spot prior to the team departing the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 July 2023
Resolved 8 July 2023
Resolution: Troubleshooting carried out by the [name withheld] immediately, and it was found that the fuse inside the distribution panel feeding the power to steering gear system ECR & bridge alarm unit burn out, now fuse was replaced with satisfactory spare part.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 8 July 2023
Resolved
Any main and auxiliary steering gear control system operable from the navigation bridge shall in the event of a failure of electrical power supply to the control system, an audible and visual alarm shall be given on the navigation bridge. After testing loss of power alarm at both port and starboard steering rooms, audible and visual loss of power alarms inoperable at both engine control room and navigation bridge. Steering alarm panel at engine control room and navigation bridge is not receiving alarm signal.
74SOLAS(04)II-1/29.8.4
Deficiency code was initially a code 17ac, but then updated to a 10c, as it was corrected on the spot prior to the team departing the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 July 2023
Resolved 8 July 2023
Resolution: Troubleshooting carried out by the [name withheld] immediately, and it was found that the fuse inside the distribution panel feeding the power to steering gear system ECR & bridge alarm unit burn out, now fuse was replaced with satisfactory spare part.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 17 December 2022
Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from emergency source of electrical power. 02 embarkation lights on the starboard side were found to be inoperable. 01 between life boat #1 and lifeboat # 3, and 01 aft of the starboard side launching station. 74SOLAS(97)iii/11.4.
Action required: 15 - Rectify deficiencies by next port
Resolved 18 January 2023
Resolution: def check on board.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 December 2022
Resolved
Fire-extingushing appliances shall be kept in good order and be available for immediate use at all times. On bulkhead deck, starboard side near sideshell door opening, section valves were blocked by excessive storage of palletized garbage/ship's stores. Improperly stored items were removed from area. Additionally at sprinkler station #22, 02 section valve gauges were missing fluid and out of callibration specifications, needing to be replaced. Gauges each read approx. 7 bar, which was the appropriate pressure for the system. 74SOLAS(97)II-2/21
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2023
Resolved 13 March 2023
Resolution: Section valve gauges replaced. Documentation attached.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 10 May 2022
Resolved
The public address system shall be clearly audible above the ambient noise in all spaces, and shall be provided with an override function controlled from one location on the navigational bridge. The entertainment sound system in the Ocean Bar on Deck 05 does not have an override function.
74 SOLAS 97 III/6.5.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 12 May 2022
Resolution: Verified by PSCO on board, The Ocean Lounge Override System is operational.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 10 May 2022
Resolved
To assist in casualty investigations, ships, when engaged on international voyages, subject to the provisions of regulation 1.4, shall be fitted with a voyage data recorder (VDR). if the ship's emergency source of electrical power supply fails, the VDR should continue to record Bridge Audio from a dedicated reserve source of power for a period of 2 h (resolution A.861(20)). Vessel's VDR alarm panel states "no battery pack connected".
74 SOLAS 20 V/20.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 12 May 2022
Resolution: Verified By PSCO and Received Class report attached.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 10 May 2022
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All lifeboats shall be properly constructed...Lifeboat No 10 has an approximate 12 inch crack around the forward part of the starboard fiberglass strut joint and an approximate 5 inch crack on the aft part of the strut joint. Lifeboat No 9 has an approximate 3 inch crack on the forward port side fiberglass strut joint.
74 SOLAS 20 III/34/ LSA Code 4.4.1
See Pictures in Documents to support Deficiency findings.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2022
Resolved 24 June 2022
Resolution: The vessel has submitted service and class reports attesting to the repairs of Lifeboat No 10 and Lifeboat No 9. Documents attached in MISLE Activity
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 24 April 2019
Resolved
The safety management system should include procedures ensuring that non-conformities, accidents and hazardout situations are reported to the company, investigated and analyzed. The company should establish procedures for the implementation of corrective action, including measures intended to prevent recurrence. Vessel does not have written procedures to properly montior structural cracking. Crew provided an inaccurate "crack log." Area of cracks and poor welding repairs at FSD A.5.011 deck A are not captured accurately. Picture and written description in the log did not represent the observed area. - ISM Code 9.1 & 9.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 8 May 2019
Resolution: Vessel provided LR Class Surveyor's Report attesting to the satisfactory resolution of the deficiency by including a "crack log" in the vessel's SMS and arranging for the major crack identified to be addressed at next dry-docking.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 April 2019
Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space. The digital workshop located on deck 5 is a room-in-room configuration. Additionally items #4&5 on letter 16710/PO4436/plc from the USCG Marine Safety Center have not been addressed. - 74SOLAS(2014)II-2/28.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 23 May 2019
Resolution: Room in a room alarms installed and tested ***See LR Report dated 18May2019***
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 24 April 2019
Resolved
In all ships general arrangement plans shall be permanently exhibited; Plans shall be kept up to date. Posted fire control plans & the escape & evacuation plans show conflicting arrangements for the digital workshop located on deck 5; to include but not limited to escape routes and fire doors. - 74SOLAS(1997)II-2/20.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 23 May 2019
Resolution: Plans amended and sent to MSC for review. See LR Report 18May2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 April 2019
Resolved
Sprinklers shall be placed in an overhead position and spaced in a suitable pattern. Numerous sprinkler heads located throughout the ship have been damaged and/or misaligned, thereby altering their intended spray pattern. - 74SOLAS(1997)II-2/12.3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 23 May 2019
Resolution: Sprinkler heads in all 5 fire zones corrected and now randomly examined. See LR Report 18May2019
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 24 April 2019
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Several stairway guides failed to display familiarity with their assigned emergency duties - 74SOLAS(2014)III/19.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 8 May 2019
Resolution: Vessel provided LR Class Surveyor's Report attesting to the satisfacotry resolution of the deficiency through additional stairway guide trainings and improvd records review of such trainings, as verified by attending LR Class Surveyor.
Engineering › Steam System (auxiliary) › Piping
Issued 22 April 2017
Resolved
01-1499-EVERY STEAM PIPE AND EVERY FITTING CONNECTED THERETO THROUGH WHICH STEAM MAY PASS SHALL BE SO DESIGNED, CONSTRCUTED, AND INSTALLED, AS TO WITHSTAND THE MAXIMUM WORKING STRESSES TO WHICH IT MAY BE SUBJECTED. STEAM SUPPLY LINE FLANGE TO NUMBER 3 FUEL OIL PURIFIER HEATER IS RUPTURED. - 74SOLAS (01 CONS) II-1/33.1 - 15C
Action required: 15 - Rectify deficiencies by next port
Due 6 May 2017
Resolved 25 April 2017
Resolution: Vessel submitted video showing the repair of equipment.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 April 2016
Resolved
02-0945-EMBARKATION STATIONS SHALL BE ADEQUATELY ILLUMINATED BY LIGHTING SUPPLIES FROM THE EMERGENCY SOURCE OF ELECTRICAL POWER. MULTIPLE EMBARKATION LIGHTS ARE OUT OF OPERATION. - 74SOLAS (09 CONS) III/11.4 - 40A
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 May 2016
Resolution: Vessel submitted documentation (photographs) that the deficiency has been corrected, with class' notification.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 23 April 2016
Resolved
01-2025-DUE TO BUNKERING OPERATIONS AND NO RECENT OBSERVATION BY USCG PERSONNEL, VESSEL IS TO SUBMIT PHOTO/VIDEO DOCUMENTATION OF THE DEPLOYMENT OF PORT SIDE LIFEBOATS 12, 14, AND TRAINING LIFERAFT. - 46CFR70.05-3 - 16C
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 4 May 2016
Resolution: Vessel submitted video documentation showing the proper launching of the lifeboats and training liferaft.