13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 June 2025
Resolved
All automatically or remotely controlled or monitored vital systems addressed by part 62 of this subchapter must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. Test procedures must be submitted to the Coast Guard for approval. Submit QFAs and DVTPs for propulsion control system using microprocessors to Marine Safety Center for approval IAW CG-CVC Policy Letter 17-07.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 September 2025
Resolution: Requirement did not apply to this vessel. Controls from the wheelhouse to the control box are mechanical.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2023
Resolved
An adult lifejacket must be provided for each person carried onboard a vessel.
Provide 63 Adult PFDs.
Vessel passenger capacity is reduced to 71 adults and three crew until new adult PFDs are provided for the full complement of passengers as per the COI.
Action required: 705 - Other - as specified
Resolved 10 May 2023
Resolution: New PFDs provided. Full passenger count allowed as per the COI.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 May 2023
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a thru-hull fitting.
The high water level alarm in the crew quarters space was inoperable.
Action required: 705 - Other - as specified
Resolved 9 May 2023
Resolution: New float switch provided
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 May 2023
Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely.
Post COI and Stability Letter in the passenger space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2023
Resolution: COI and Stability Letter posted
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 9 May 2023
Resolved
Except when operating on lakes, bays, and sounds, or rivers routes in calm weather, all hatches and openings in the hull, except loading doors, of a vessel must be kept tightly closed except when being used.
Aft house door on the main deck cannot be closed from the inside and needs new dogs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2023
Resolution: New dog installed on door.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 11 May 2022
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission.
Missing Safety radio and Bridge to Bridge certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 27 May 2022
Resolution: Vessel recieved the required FCC documents
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
21 life jackets missing or failed passenger count reduced to 113 passengers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 June 2022
Resolution: Placed 21 new life jackets in service with lights and whistles
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 May 2022
Resolved
For a life float - Approved under approval series 160.027 or other standard specified by the Commandant.
Two 12 man life floats wasted. Vessel reduced to 60 persons on Oceans route. 120 passengers with 20 miles of harbor of safe refuge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 May 2022
Resolution: replaced bottom of the two life floats.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 May 2022
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
EPIRB hydrostatic release expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 13 May 2022
Resolution: replaced hydrostaatic release
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 May 2022
Resolved
A whistle fitted in a vessel shall provide, in the direction of maximum intensity of the whistle and at a distance of 1 meter from it.
Ships whistle was not operable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 13 May 2022
Resolution: corrected loose wire on horn.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 May 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 27 May 2022
Resolution: Vessel placed current chart and navigational pubs onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: Prevent electrical ignition of flammable vapors.
Genset windings are coated with oil, require proper cleaning
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 13 June 2022
Resolution: Received documentation that windings were cleaned
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 May 2022
Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device: (i) A self-propelled vessel of 65 feet or more in length, engaged in commercial service.
Prove proper operation of installed AIS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2022
Resolved 13 June 2022
Resolution: received documentation that AIS is broadcasting.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 June 2021
Resolved
Vessel required to carry current/up to date navigational charts for areas transited. Existing charts were outdated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 1 November 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 June 2021
Resolved
Vessel required to carry current/up to date navigational publications for areas transited. Existing navigational publications, i.e.: USCG Light List was expired/out of date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 31 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 June 2021
Resolved
Batteries in lifesaving equipment shall be renewed annually. Existing batteries in floating water lights for ring buoys and life floats required replacement due to age/damage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 31 August 2021
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 June 2021
Resolved
VHF-FM radiotelephones equipped with DSC must be capable of broadcasting vessels position. Existing VHF-FM radiotelephone is not interfaced with installed GPS.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 1 November 2021
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 22 June 2021
Resolved
Vessel is required to be equipped with a ship's whistle with an audible range of 1.5 miles. Existing ships whistle was found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 26 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 June 2021
Resolved
Vessel required to be equipped with navigational lights. Existing N.U.C. light (lower) was found inoperable due to broken wiring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 9 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 June 2021
Resolved
Fire hazards should be minimized on board vessels. Fuel leaks noted IWO RACOR fuel filters for MDE's & inboard side of the starboard MDE @ fuel rack.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 9 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 June 2021
Resolved
Vessels fixed bilge piping system is required to be equipped with a reach rod assembly if valve is located fwd of the collision bulkhead. Existing reach rod assembly was found disconnected from bilge suction valve.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 7 September 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 June 2021
Resolved
Vessels watertight hatches are required to be marked "WATERTIGHT HATCH KEEP CLOSED". Existing hatches were improperly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 31 August 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2021
Resolved
Vessels seating is required to be secured/mounted properly. Existing seating hardware was found loose/unsecured in way of starboard side accomodation space, row #3.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 7 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 June 2021
Resolved
Vessel required to be equipped with emergency lighting from crew accomodations spaces below the main deck. Existing emergency lighting IWO forward storeroom/workshop was found inoperable.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 7 September 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 June 2021
Resolved
The scope of the annual inspection is the same as the inspection for certification but in less detail unless the cognizant marine inspector finds deficiencies. Attending Inspector(s) identified fractures in way of port/starboard chines just aft of fwd watertight bulkhead in 2nd compartment/void (former rod room). Affected areas to be closely monitored at subsequent inspections. Repairs due NLT next scheduled drydock.
Action required: 705 - Other - as specified
Due 25 March 2022
Resolved 25 January 2023
Resolution: cleared at drydock inspection
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 April 2020
Resolved
Vessel required to carry operable Cat. 1 406 MHz EPIRB if operating on the high seas. Vessels Cat. 1 406 MHz EPIRB battery was found expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified installation of new EPIRB/bracket/HRU.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 April 2020
Resolved
Vessel required to be equipped with a self priming, power driven fire pump. Vessels fire pump was removed from the vessel for servicing/repair.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified installation of (new) fire pump. Witnessed operational test.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 April 2020
Resolved
Vessels portable fire extinguishers require annual servicing/maintenance. Vessels portable fire extinguishers were out of date/annual service expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified annual servicing of portable fire extinguishers.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 30 April 2020
Resolved
Vessel required to carry current/up to date navigational publications for areas transited. Vessels existing navigational publications were expired (2019).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications for areas transited.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 April 2020
Resolved
Vessel required to carry current/up to date marine charts for areas transited. Existing marine chart is out of date/does not cover vessels entire area of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified carriage of current/up to date marine charts for areas transited.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 April 2020
Resolved
Vessel required to carry proper type/size of first aid kit for vessels service. Expired items noted in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified renewal of expired items in first aid kit(s).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2020
Resolved
Vessels paddles for life floats are required to be marked with vessels name. Life float paddle markings were worn/faded.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified renewal of markings for life float paddles.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 April 2020
Resolved
Vessels Operator/Crew required to be enrolled in an approved drug testing consortium. Owner/Operator could not produce a current/up to date proof of enrollment in an approved consortium.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified proof of enrollment in an approved consortium.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 April 2020
Resolved
PFD stowage locations are required to be marked with size/qty. Existing PFD stowage location markings are worn/faded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified renewal of PFD stowage markings.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 April 2020
Resolved
Vessels means of escape must be legibly marked on both sides. Vessels exterior doors that lead to the main accomodations space are not properly marked (Emerency Escape).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified emergency exit markings IWO side (sliding) doors for main accomodations space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2020
Resolved
Vessel required to be equipped with a fixed bilge system capable of dewatering all compartments. Gate valve for forepeak suction IWO fwd compartment was "frozen" shut.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified operation of gate valve for forepeak suction (fixed bilge system).
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2020
Resolved
Vessels conductors shall be properly secured to prevent movement/chafing. Conductors IWO fwd comparment (outboard/stbd side) are not properly secured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified installation of securing devices for electrical conductors.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 April 2020
Resolved
Vessels watertight bulkhead penetrations are required to be made watertight. Existing bulkhead penetrations IWO fwd compartment aft bulkhead (stbd/outboard) are not properly sealed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified sealing of bulkhead penetrations.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 30 April 2020
Resolved
An inspection for renewal of a COI is conducted to determine if the vessel is in satisfactory condition, fit for service intended and complies with applicable regulations. Attending Inspector(s) called out fractured weldment(s) IWO chine bar/transverse framing IWO rod room compartment (port side).
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 18 March 2021
Resolution: Corrected during 2021 drydock.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 April 2020
Resolved
An inspection for the renewal of a COI is conducted to determine if the vessel is in satisfactory condition, fit for service intended, and complies with applicable regulations. Ladder assembly for machinery space/engine room was missing mounting/securing hardware.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified installation of mounting hardware for vertical ladder assembly IWO engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 April 2020
Resolved
Vessel required to be equipped with emergency lighting. 12V lighting fixture IWO engine room overhead (stbd) was missing securing hardware.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified installation of mounting hardware for 12V lighting IWO engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 April 2020
Resolved
An inspection for renewal of a COI is condcuted to determine if vessel is in satisfactory condition, fit for route intended, and complies with applicable regulations. Vessels ships service diesel generator has a rear main oil seal leak resulting in lubricating oil seeping into the generator fan assembly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 21 June 2021
Resolution: Oil leak has slowed and is being monitored by vessels crew.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 April 2020
Resolved
Vessels lifesaving equipment/arrangements require annual servicing of water lights. Existing water light batteries are expired/require renewal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified renewal of life saving equipment batteries.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 30 April 2020
Resolved
Vessels main deck watertight hatches are required to be fitted with proper type/size of gasketing. Existing gasketing is worn/requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2020
Resolved 13 May 2020
Resolution: Attending Inspector(s) verified installation of gasketing material for main deck hatches. Witnessed satisfactory water test.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2019
Resolved
Junction box/switch IWO operators console not properly installed/mounted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified proper installation of box/cover.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 July 2019
Resolved
Dead ended wiring identified IWO main operators console.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Witnessed removal of dead ended wiring.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 July 2019
Resolved
Expired marine chart(s) for areas transited.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified carriage of current/up to date marine charts for areas transited.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 July 2019
Resolved
Expired/out of date navigational publications for areas transited.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified carrige of current/up to date navigational publications for areas transited.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 July 2019
Resolved
Ship's whistle/horn was inoperable at time of inspection. Vessel carried means to make an "efficient sound signal" (aerosol air horn/can).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified installation/operation of ship's whistle/horn.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 July 2019
Resolved
Missing/deteriorated gasketing material IWO pilothouse exterior doors (port/stbd) & aft main deck door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified repairs to exterior door gasketing.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 July 2019
Resolved
Emergency lighting fixture IWO fwd crew quarters required replacement due to improper mounting/fractured base.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified installation/operation of emergency lighting fixture.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 July 2019
Resolved
Missing double hose clamps for fixed bilge flex lines IWO fwd engine room/centerline.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified proper installation of clamps.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 29 July 2019
Resolved
Inoperable/fractured lens IWO engine room lighting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified repairs/installation of engine room lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2019
Resolved
Excess water in battery boxes IWO engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified removal of excess water in battery boxes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2019
Resolved
SSDG battery not properly braced to prevent movement for SSDG.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified installation of blocking/bracing for battery installations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2019
Resolved
Flexible hose connections for drain IWO engine room/centerline required replacement due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified installation/renewal of flexible hose connections IWO drains.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2019
Resolved
Breakers IWO panelboard (port aft engine room @ bulkhead) not properly labeled/identified.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified labeling for breakers IWO port aft panelboard (engine room).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2019
Resolved
SSDG raw water intake flexible hose connections not properly secured with double hose clamps.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified installation of clamps IWO SSDG raw water intake.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 29 July 2019
Resolved
Main vertical ladder for engine room missing hardware @ base.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified installation of hardware for ladder assembly (engine room).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2019
Resolved
Main SSDG electrical switchboard gauges broken/inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified installation/operation of main switchboard gauges.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2019
Resolved
Battery conductors IWO starboard engine room (aft of main engine) are not properly secured (laying in bilges).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified installation of supports for battery conductors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2019
Resolved
Openings IWO port aft panelboard (engine room).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified installation of "blanks" IWO port aft panelboard (engine room).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 July 2019
Resolved
Fixed bilge piping IWO lazarette missing double hose clamps IWO flex couplings.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified installation of clamps IWO fixed bilge piping flexible hose (lazarette).
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 July 2019
Resolved
Intermittent operation of navigational lighting (stbd side light/fwd mast head light).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified operation of navigational lights.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 July 2019
Resolved
Missing upper rail course IWO main vertical ladder between main deck and bow.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified installation of upper rail course for vertical ladder (fwd).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 July 2019
Resolved
Worn retro-reflective markings IWO ring life buoys.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified renewal of retro-reflective markings for life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 July 2019
Resolved
12-person life float was deemed unserviceable and was removed from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 June 2021
Resolution: CG-835V was issued reducing passenger count.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2019
Resolved
Emergency fuel shut-off valves were not properly marked with operating instructions.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2019
Resolved 22 August 2019
Resolution: Verified operating instructions for emergency fuel shut-off valves.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 July 2018
Resolved
Vessels VHF-FM radiotelephones are required to be programmed with vessels MMSI # (for DSC equipped radiotelephones). Vessel is equipped with two VHF-FM marine radiotelephones, neither of which are properly programmed with vessels MMSI #.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 9 October 2018
Resolution: Attending Inspector(s) verified programming of VHF-FM radio-telephones with MMSI #.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 July 2018
Resolved
Vessel is required to carry a properly programmed Class A AIS system on board. Vessels is equipped with a Class A AIS system, however, the vessels call sign is not properly programmed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 28 August 2019
Resolution: Vessel is equipped with operable Class A AIS unit. Cleared from previous inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 July 2018
Resolved
Vessels emergency exits are required to be marked/identified. Vessels port side accomodations sliding door was not properly marked/identified with emergency exit markings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 9 October 2018
Resolution: Attending Inspector(s) verified posting of emergency exit markings IWO port side accomodations sliding door.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 27 July 2018
Resolved
Vessel is required to be fitted with an operable MSD system on board since it is fitted with installed toilets. Vessels flex couplings IWO machinery space piping for MSD system was found cracked/deteriorated. *To be corrected at next scheduled drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 28 August 2019
Resolution: Discrepancy was addressed during MAR 2019 dry-dock (SEC CHAR).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2018
Resolved
Vessel is equipped with battery chargers. Vessels battery charger IWO port aft machinery space was found damaged beyond repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 9 October 2018
Resolution: Attending Inspector(s) verified installation of new battery charger IWO machinery space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2018
Resolved
Vessel is equipped with panelboards in various spaces on board. The panelboards located in the rod room and machinery space were found with open breaker slots.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 9 October 2018
Resolution: Attending Inspector(s) verified installation of blanks IWO panelboard (machinery space).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2018
Resolved
Vessels lifesaving arrangment(s) are required to have spacers installed between each float. Vessels life floats were noted without spacers installed between each float.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 9 October 2018
Resolution: Attending Inspector(s) verified installation of spacers between life floats.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 27 July 2018
Resolved
Vessel is required to have adequate lighting in all working spaces. Vessels overhead lighting fixture IWO starboard machinery space was found damaged & required repair/replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 9 October 2018
Resolution: Attending Inspector(s) verified installation of (new) lighting fixture IWO starboard machinery space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 July 2018
Resolved
Vessel's watertight doors/hatches are required to seal properly to prevent ingress of water. Vessels main deck watertight hatch gaskets required replacement (loss of sealing capability/non pliable).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 9 October 2018
Resolution: Attending Inspector(s) verified installation of hatch gaskets IWO main deck watertight hatches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2018
Resolved
Vessels exhaust systems may be equipped with a flexible non-metallic hose where necessary for flexibility. Vessels exhaust systems IWO flexible hose connections show signs of salt corrosion/pitting in the aluminum piping at flex hose connections. *Remove flex hose couplings for all exhaust piping at next scheduled drydock for further inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 28 August 2019
Resolution: Discrepancy addressed during MAR2019 drydock (SEC CHAR).
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 27 July 2018
Resolved
Vessel's machinery space shall be free from fire hazards, i.e.: accumulation of oil. Vessels ships service diesel generator's rear main seal has failed causing oil/oil mist to be introduced into the machinery space/overhead/adjacent machinery. *Generator repair to be effected within 30 days. Removal of oil/oil residue IWO machinery space to be cleaned immediately.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 9 October 2018
Resolution: Attending Inspector(s) verified the removal of oil/oily residue from machinery space bulkhead/bilges/piping.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 July 2018
Resolved
Fractured weldments noted IWO port aft ladder between main/upper deck. *Located on outer edges of weldments. To be corrected at next scheduled drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 18 March 2021
Resolution: Corrected during drydock 2021.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 27 July 2018
Resolved
Vessel is equipped with emergency lighting IWO machinery space. Vessels emergency lighting IWO fwd/centerline watertight bulkhead (machinery space) was found damaged/inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 9 October 2018
Resolution: Attending Inspector(s) verified installation of (new) emergency exit lighting fixture IWO machinery space.
Navigation › Piloting/Steering › Marine Charts
Issued 22 May 2017
Resolved
Vessel did not carry current/up to date navigational publications for areas transited.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 29 June 2017
Resolution: Attending Inspector verified carriage of current/up to date navigational publications for vesels route/areas transited.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 May 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 29 June 2017
Resolution: Attending Inspector verified carriage of current/up to date FCC documentation/certificates.
Communications › Radio Communications › EPIRB
Issued 22 May 2017
Resolved
Vessels hydro-static release for EPIRB was expired/out of date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 29 June 2017
Resolution: Attending Inspector verified installation of new hydro-static release for EPIRB.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 22 May 2017
Resolved
EAP (program) was not implemented/posted on board.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 28 July 2018
Resolution: Attending Inspector(s) verified implementation/posting of EAP (program).
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 May 2017
Resolved
Vessels navigation lights have been altered to accept household bulbs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 28 July 2018
Resolution: Attending Inspector(s) verified installation of approved LED marine bulbs.
Lifesaving › Lifefloat › Float Free
Issued 22 May 2017
Resolved
Vessels life float stowage missing spaces for tiered storage.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 29 June 2017
Resolution: Attending Inspector verified installation of wooden spaces for life float stowage.
Fire Fighting › Nozzles › Type
Issued 22 May 2017
Resolved
Vessels fire nozzles were not the proper type (fog/straight stream)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 29 June 2017
Resolution: Attending Inspector verified the carriage of proper size/type of fire nozzles.
Documentation › Markings/Placards › Warning Signs
Issued 22 May 2017
Resolved
Vessels main deck hatches were not properly marked (Watertight Hatch Keep Closed)
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 29 June 2017
Resolution: Attending Inspector verified markings for watertight hatches.
Documentation › Markings/Placards › Warning Signs
Issued 22 May 2017
Resolved
Vessel emergency exits were not properly identified/marked.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 29 June 2017
Resolution: Attending Inspector verified markings for emergency escapes along the main deck.
Stability › Watertight Integrity › General
Issued 22 May 2017
Resolved
Vessels watertight bulheads were not properly sealed in way of cableways.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 29 June 2017
Resolution: Attending Inspector verified repairs made in way of cableways.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 22 May 2017
Resolved
Owner could not provide proof of enrollment in an approved/recognized drug & alcohol testing consortium.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 28 July 2018
Resolution: Attending Inspector(s) verified proof of enrollment in an approved consortium.