Records from 2003 to 2026. Most recent: inspection, 26 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 21
26 May 2026
Internal Structural Exam · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8382911
10 March 2026
Vessel Attendance · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8323621
13 June 2025
Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8198272
26 February 2025
Internal Structural Exam · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8088511
15 March 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7879917
6 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7861599
11 May 2023
Internal Structural Exam · COI Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7690489
8 December 2022
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7606436
13 October 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7577164
18 May 2022
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7454075
23 December 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7372500
9 August 2021
Special Consideration
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7282607
27 April 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7183399
18 May 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6955031
4 February 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6901911
21 February 2019
COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6629449
9 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6506182
21 May 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6414780
23 March 2018
Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6373131
15 May 2017
Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6144831
21 March 2016
Administrative Inspection · Deficiency Check · Annual Inspection · Hull Examination · Internal Structural Exam · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5837173
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 March 2024
Resolved
A Certificate of Inspection is valid for 5 years. Vessel did not complete COI renewal inspection prior to drop dead date due February 21, 2024. Vessel will need to complete COI inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2024
Resolution: Conducted COI inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2023
Resolved
All electrical installations shall be to the satisfaction of the officer in charge, Marine Inspections. Found several dead end wires in space behind operating station. Remove/repair all dead end wires behind operating station.
46 CFR 183.01-15
Old "T"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2023
Resolved 3 October 2023
Resolution: received photos
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 May 2023
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Found broken float light bracket located starboard side of radar mast above cabin. Replace broken float light bracket.
46 CFR 180.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2023
Resolved 3 October 2023
Resolution: Received photo
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 May 2022
Resolved
Breaker panel on bridge had missing individual breaker covers presenting a shock risk. Cover with apppropriate means.
46 CFR 183.01-15(a)
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 14 October 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 May 2022
Resolved
Identified 6 dead end wires in space behind operating station. Remove or place in electrical box for safety.
46 CFR 183.01-15(a)
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 20 October 2022
Resolution: Provided photo evidence.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 18 May 2022
Resolved
Vessel master was missing Marine Radio Operators Permit. Show proof of permit.
46 CFR 80.156
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 14 October 2022
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 May 2022
Resolved
Epirb hydrostatic release was expired. Replace or provide verification of installation date. Vessel is restricted to 3nm.
46 CFR 185.740(b)
Action required: 705 - Other - as specified
Resolved 14 October 2022
Resolution: installed new HSU
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 May 2022
Resolved
Engine room ventilation closures were permanently mounted not allowing for rapid closure in an emergency. Replace with releasable hardware.
46 CFR 181.20-35(a)
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 14 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2022
Resolved
Port side fire station valve was inoperable. Repair/replace.
46 CFR 181.15-5(c)
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 14 October 2022
Resolution: replaced valve
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 May 2022
Resolved
First aid kid had expired ammonia inhalants. Provide appropriate replacement.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 20 October 2022
Resolution: Provided photo evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2022
Resolved
Retro-reflective tape on both port and starboard lifebuoys were worn. Replace with appropriate Type I retro-reflective tape.
46 CFR 180.70 (b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 14 October 2022
Resolution: re applied retro
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 May 2022
Resolved
Lash lifefloat paddles appropriately to lifefloat.
46 CFR 180.175(f)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 14 October 2022
Resolution: lashed
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 April 2021
Resolved
Label all circuit breakers in the #1, #2,& #3 Distribution panels and install Blanks in all open breakers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 18 May 2022
Resolution: Reattended vessel. Labeled all breakers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021
Resolved
Engine Room starboard Generator Start battery; wire connections needs proper terminals installed and replace solid copper wire with UL Marine Boat Cable or Copper Stranded wire.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 18 May 2022
Resolution: Reattended vessel. Installed new wire.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 27 April 2021
Resolved
Lighting in engine room spaces need to be properly shielded. Port Engine overhead light missing protective cover. Install appropriate cover to overhead light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 18 May 2022
Resolution: Reattended vessel. Covered all lights in engine room with cages.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2021
Resolved
Port Generator exhaust leak at water injection. Provide plan proposal for temp repair. Permanent repair will be required for upcoming Dry Dock.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 18 May 2022
Resolution: Reattended vessel. During drydock, has port generator exhaust leak repaired at Yanks Marine.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021
Resolved
Re-arrange electrical equipment installations (Microwave, Kureg, Toaster oven, etc...) in port Galley
amongst the 3 localized outlets to eliminate the outlet multiplier.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 18 May 2022
Resolution: Reattended vessel. Removed outlet multiplier.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021
Resolved
Open Ground found in the Galley outlet, port outboard side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 18 May 2022
Resolution: Reattended vessel. Repaired ungrounded outlet in galley.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2021
Resolved
Apply Type-II reflective tape to 3 ring life buoys. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 28 May 2021
Resolved 28 April 2021
Resolution: Vessel representative acquired Reflective tape and placed it on all 3 ring life buoys.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 April 2021
Resolved
Vessels over 65 feet are required to be fitted with 2 fixed Self-Priming power driven bilge pumps. Bilge pumps connected to the Fire main, must also be Self-Priming. Replace existing pumps with required Self-Priming pumps that meet the operating capacity requirements of 46 CFR 182.25-10(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 9 August 2021
Resolution: Special consideration granted to fire pump PSI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 May 2020
Resolved
Obtain 2 paddles for life float and mark with vessel's name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2020
Resolved 5 June 2020
Resolution: Received email containing pictures of new life float paddles.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 February 2020
Resolved
Identified 02 cracks in stbd keel approx. 30' from bow.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2020
Resolved 18 May 2020
Resolution: Area repaired to the satisfaction of the attending CG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 February 2020
Resolved
Port and Stbd main engines were missing double hose clamps in exhaust cooling hose.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2020
Resolved 18 May 2020
Resolution: Vessel added missing double hose clamps.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018
Resolved
Vsl is broadcasting: Invalid MMSI, invalid Call Sign, no static draft information, greater/smaller than expected vessel length, and broadcasting invalid AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 6 November 2018
Resolution: AIS information updated.
Fire Fighting › Fire Pumps › Arrangement
Issued 23 March 2018
Resolved
KNS01: Provide specs for previous and new firepump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 26 April 2018
Resolution: Received via email 26APR2018.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 23 March 2018
Resolved
KNS02: Provide manufacturer U-1A data report for air receiver engine.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 26 April 2018
Resolution: Received via email 26APR2018.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 May 2017
Resolved
Vessel shall conduct man overboard and firefighting drills in presence of marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 23 August 2017
Resolution: Conducted drill on similar vessel with same crew, owned by same person. All sat.
Engineering › Compressed Air System (control) › Valve
Issued 15 May 2017
Resolved
Prove proper operation of relief valves on installed air compressor and air receiver. Prior to operation of air receiver.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 December 2017
Resolution: [name withheld] proved proper operation.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 15 May 2017
Resolved
Total capacity of persons onboard reduced to 124 until 10 condemned lifejackets are replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 7 December 2017
Resolution: [name withheld] showed new purchase.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2017
Resolved
Install machinery guard over moving belt on starboard generator.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 7 December 2017
Resolution: Observed machinery guard.
Fire Fighting › Fire Pumps › Pressure
Issued 15 May 2017
Resolved
Repair pressure gauge on port fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 7 December 2017
Resolution: Repaired.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 15 May 2017
Resolved
Identify source and repair ground to satisfaction of attending marine inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 23 August 2017
Resolution: Received sat picture of rectification.
Construction/Loadline › Penetrations › Gasket
Issued 17 May 2016
Resolved
Make hatch gasket on void #1 watertight.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 22 June 2016
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 17 May 2016
Resolved
Wire nuts on run STBD side AFT and in way of Marine Radio make permanent conncections.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 31 May 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 17 May 2016
Resolved
Provide guard for light in port side void #2.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 31 May 2016
Fire Fighting › Ventilation Systems › Ducts
Issued 17 May 2016
Resolved
Provide covers for upper deck machinery space ventilation.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 31 May 2016
Engineering › Compressed Air System (control) › Compressor
Issued 17 May 2016
Resolved
Perform hydrostatic test on air receiver or remove from vessel.
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 2 August 2016
Resolution: Pressure vessel is ASME approved, pictures entered into system.
Electrical › Electric Generation Source (service) › Panelboard
Issued 17 May 2016
Resolved
Label all breaker panels
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 31 May 2016
Fire Fighting › Grease Extraction Hood › General
Issued 17 May 2016
Resolved
Clean grease in galley hood.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 18 May 2016
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 17 May 2016
Resolved
Secure MSD overboard discharge.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 31 May 2016