HOKUA

Built
1998
Last inspected
21 October 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 October 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB8016
475436
Flag
UNITED STATES
Maury page id
psix-475436

Documentation record

Registered dimensions (L × B × D)40.0 ft × 13.0 ft × 8.0 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDOUGLAS PHILLIPS · KILAUEA, HI, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionJet Drive
Hull shapeShip
Hull configurationTwin Hull
Hailing portMAALAEA, HI
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 27 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 45 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

21 October 2025 COI Inspection · Drydock Exam · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8256648
15 October 2024 Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8018853
5 December 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7833476
17 October 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7810104
25 October 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7583685
19 July 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7513198
18 December 2021 Damage Survey · Deficiency Check · Construction Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7370268
2 November 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7343673
21 September 2021 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7316851
20 May 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7309614
28 October 2020 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7085580
31 January 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6900713
13 November 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6855267
14 August 2019 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6785488
17 May 2019 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6686808
12 December 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6596560
21 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6585146
21 September 2017 Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6272224
6 February 2017 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6087838

Deficiency record · 45

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Port and starboard Hydraulic pump hose lines forward of both engines worn and wasted. Both hoses require renewal. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2025
Resolution: Hydraulic Hose renewed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 October 2025 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by table 46 CFR 181.500(a)and other provisions of this section. Vessel carries (04) 10 B:C portable fire extinguishers. Vessels COI requires 1-10 B:C and 2-40 B:C. Provide (02) 40 B:C's as required by COI. 46 CFR 181.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2025
Resolution: (02) 40 B:C Fire extinguishers installed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 October 2025 Resolved
At inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each hydrostatic release unit (HRU) to determine that it is in compliance with the servicing and usage requirements of 185.740 of this chapter. Hydrostatic release for EPIRB expired. Install new HRU. 46 CFR 176.808(a)(5)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2025
Resolution: Hydrostatic release unit renewed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 October 2024 Resolved
At each inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the inspection and operation of all watertight closures in decks. Starboard engine hatch support rod, outboard side plate detached from frame and port forward hatch support rod broken. Both require repair or replacement. 46 CFR 176.802(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2024
Resolved 6 November 2024
Resolution: Starboard engine hatch and port forward hatch strut (support rods) replaced.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 October 2024 Resolved
A duct must be of rigid permanent construction, made of the same material as the hull or of noncombustible material. Provision must be made for closing all exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Engine compartment vent openings require closing mechanism. Blocking vent opening with a rag is not accepted. 46 CFR 182.460(h)(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2024
Resolved 6 November 2024
Resolution: New fabricated aluminum vent closures installed on to vessel.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 15 October 2024 Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited the operator must secure each Type I or Type II device in a manner which prevents discharge. Acceptable methods include: Padlocking the seacock in the closed position. MSD overboard discharge valve located in head unsecured. Requires new padlock. 33 CFR 159.7(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2024
Resolved 6 November 2024
Resolution: Padlock installed at MSD discharge valve.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 15 October 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit on board found with expired contents and unsuitable condition. Requires replacement. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2024
Resolved 6 November 2024
Resolution: New CG approved first aid kit installed on vessel
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 October 2024 Resolved
A vessel on an oceans, coastwise, or limited coastwise route must carry (1)Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q and(2)Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter. Vessels distress signals found expired. 46 CFR 180.68(a)(1)(2)
Action required: 10 - Deficiency Rectified
Resolved 15 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel COI calls for 38 adult like jackets. 37 counted on board. Requires 01 additional. 46 CFR 180.71(a)
Action required: 10 - Deficiency Rectified
Resolved 15 October 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel does not have any means to test for presence of alcohol. 46 CFR 4.06-15 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2024
Resolved 15 December 2023
Resolution: Test devices provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2023 Resolved
The employer shall provide an Employee Assistance Program for all crewmembers that includes both education and training on the effects and consequences of drug and alcohol use. Crewmember must receive training. Vessel's O/O has established an Employee Assistance Program as part of the company's chemical testing program, but has not completed the program. Provide satisfactory evidence of an Employee Assistance Program training for crew. 46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2024
Resolved 15 December 2023
Resolution: Training provided.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 December 2023 Resolved
Each vessel must be equipment with at least two operable portable battery lights and one for each engine space. Vessel does not have light for each engine space. Provide portable lights. 46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2024
Resolved 13 December 2023
Resolution: Portable lights provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 December 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's stbd fuel shutoff valve did not fully close. Provide fully operational fuel shutoff. 46 CFR 182.455(b)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2023
Resolution: Fuel shutoff operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2022 Resolved
Machinery and equipment installed must be suitable for the vessel and its operation. Hydraulic hose fittings both port and starboard showing signs of corrosion. Remove fitting and provide new approved J-1942 hydraulic hose and fitting. 46 CFR 182.100 46 CFR 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 7 November 2022
Resolution: New hoses and fittings provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 October 2022 Resolved
The Life Float Light must be attached by 3/8 inch lanyard, resistant to UV, and at least 18 feet in length. Life Float light line deteriorated and not of proper length. Provide new line that meets length. 46 CFR 180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 4 November 2022
Resolution: New line provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 October 2022 Resolved
Ring buoy must be fitted with a lifeline 60 ft in length, be at least 5/16 inch, be dark color if synthetic or a type certified to be resistant to deterioration from UV light. Line from ring buoy deteriorated. Provide new line. 46 CFR 180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 4 November 2022
Resolution: New line provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 October 2022 Resolved
Life float painter must be at least 100 ft in length, be of a dark color if synthetic, or of a type certified to be resistant to deterioration from UV light, and be stowed in a way that it runs out freely when the life float floats away. Painter deteriorated. Provide new painter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 4 November 2022
Resolution: New painter provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 October 2022 Resolved
Each survival craft must be secured by a painter with a float-free link permanently attached to the vessel. Weak link(float free device)did not have tag showing its ability to float-free. Provide weak link with appropriate tag. 46 CFR 180.130(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 4 November 2022
Resolution: New weak link provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 October 2022 Resolved
Vessel must be provided with one fixed power bilge pump and one portable hand pump. Portable hand pump was leaking. Provide new portable hand pump. 46 CFR 182.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 7 November 2022
Resolution: New hand pump provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 October 2022 Resolved
Vessel does not currently meet the requirements of Work Instruction 31. Mandated crew posted on COI may not enter the water or act as lifeguard until policy and procedure provided. Provide written procedure. 46 CFR 176.100(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 2 November 2022
Resolution: Work Instruction 31 procedures provided.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 December 2021 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Crewmembers from the HOKUA reported sucking the spring line into the portside jet drive which caused an approximate one inch wide by seven inch crack in the port side grate and is splintering approximately one half inch into the hull. Vessel must be hauled out, damage assessment conducted and permanent repairs made to engine and/or hull.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2021
Resolved 27 December 2021
Resolution: Repairs made, sea trials conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 November 2021 Resolved
Vessel must be equipped with portable lights at the operating station and access to the machinery space. No portable lights on vessel. Provide dedicated portable lights for operating station and engine space. 46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 5 November 2021
Resolution: Lights provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 November 2021 Resolved
Installation of portable fire extinguisher must be in accordance with manufacture. Extinguisher not placed in bracket. Provide bracket for lower forward fire extinguisher. 46 CFR 181.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 5 November 2021
Resolution: Extinguisher provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 November 2021 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each machinery space. Visual indication of high water not operational at operating station for starboard engine room. Provide operational visual indicator at operating station for stbd engine room. Conduct and rounds every 30 minutes until operational. Rectify within 14 days. 46 CFR 182.530
Action required: 705 - Other - as specified
Due 16 November 2021
Resolved 15 November 2021
Resolution: Visual indicator operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 November 2021 Resolved
All electrical equipment must be suitable for the voltage and current. Dead end wires found behind helm. Remove dead end wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 15 November 2021
Resolution: Dead end wires removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel. 46 CFR 16.401(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 29 November 2021
Resolution: Drug training completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 October 2020 Resolved
Starboard engine room bilge high water visual indicator at helm not operational. Provide operational high water visual indicator at helm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 27 November 2020
Resolution: Indicator operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 October 2020 Resolved
Gasoline cans located in lazarette. Remove hazardous cans from vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 27 November 2020
Resolution: Gasoline cans removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2020 Resolved
Hot water pump (soda pump) in starboard battery space not secured. Mount pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 27 November 2020
Resolution: Pump secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 28 October 2020 Resolved
02 hatches on forward deck cracked. Provide hatches that are not cracked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 29 December 2020
Resolution: New hatches installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 October 2020 Resolved
Fuel vent missing proper 30x30 screen. Provide 30x30 screen at fuel vent opening.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 27 November 2020
Resolution: Screen provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 October 2020 Resolved
Aft deck railing and entrance railing not meeting 39.5 inch requirement. Provide railing that meets 39.5 inch height requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 27 November 2020
Resolution: Rail provided.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 November 2019 Resolved
Life float light was extinguished. Provide functional light in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 11 February 2020
Resolution: Light repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2019 Resolved
Stbd emergency fuel valve did not close completely. Repair in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 11 February 2020
Resolution: Valve closes completely.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 November 2019 Resolved
Stbd running light was extinguished. Repair in accordance with 46 CFR 176.816. Vessel limited to day light operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 February 2020
Resolution: Stbd running light repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 November 2019 Resolved
Radio Safety Certificate was not provided. Provide in accordance with 46 CFR 184.502.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 11 February 2020
Resolution: Certificate provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 November 2019 Resolved
VHF DSC radio function was not programmed. Prove function in accordance with 46 CFR 184.502.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 11 February 2020
Resolution: DSC VHF radio function programmed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 August 2019 Resolved
Port installed extinguishing system audible and visual alarm did not function at operating station when tested. Prove correct operation in accordance with 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2019
Resolved 13 November 2019
Resolution: System test satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 November 2018 Resolved
Stbd Fireboy system did not secure engine after activation. Prove proper function of Fireboy system in accordance with 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2018
Resolution: System operates correctly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 November 2018 Resolved
Port Fireboy system did not allow engine to start after activation. Prove proper function of Fireboy system in accordance with 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2018
Resolution: System operates correctly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 November 2018 Resolved
Cabin and operating station portable extinguishers were not mounted. Mount in accordance with 46 CFR 181.520.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2018
Resolution: Extinguishers mounted.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 6 February 2017 Resolved
Prove proper operation of port and STBD Fireboy pull cable and shutdown switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2017
Resolution: Fireboy system operating properly.
Lifesaving › Lifefloat › Float Free
Issued 6 February 2017 Resolved
Provide current hydrostatic release for Lifefloat and Epirb.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2017
Resolution: New hydrostatic releases are installed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 February 2017 Resolved
Conduct drill in presence of CG Marine Inspector.
Due 3 March 2017
Resolved 10 February 2017
Resolution: Drills were conducted at pier due to weather and Crew conducted U/W next day.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 6 February 2017 Resolved
Provide proof of monthly required lifesaving equipment maintenance and quarterly drills.
Due 1 June 2017
Resolved 13 October 2017
Resolution: Provided.

Ownership record