HOKUA

HOKUA is a 1998 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1993, most recently in October 2025, along with 64 deficiencies and 3 casualty investigations between 2009 and 2012.

Records from 1993 to 2025. Most recent: inspection, 21 October 2025.

Built
1998
Last inspected
21 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB8016
475436
Flag
UNITED STATES
366951480
Maury page id
psix-475436

Inspections, by type

…with no type recorded11
Years with a record 27 calendar years (1993–2025)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.0 ft × 13.0 ft × 8.0 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDOUGLAS PHILLIPS · KILAUEA, HI, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionJet Drive
Hull shapeShip
Hull configurationTwin Hull
Hailing portMAALAEA, HI
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 27 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB8016MMSI 366951480 · active · compulsorily equipped · granted 13 March 2024, expires 26 May 2034
WCZ2632MMSI not assigned · expired · compulsorily equipped · granted 13 May 1999, cancelled 18 July 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LIQUID ALOHA Passenger (Inspected) · MISLE 461284 · 30 January 2012 · activity 4290812

Inspection history · 60

21 October 2025 COI Inspection · Drydock Exam · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8256648
15 October 2024 Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8018853
5 December 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7833476
17 October 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7810104
25 October 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7583685
19 July 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7513198
18 December 2021 Damage Survey · Deficiency Check · Construction Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7370268
2 November 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7343673
21 September 2021 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7316851
20 May 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7309614
28 October 2020 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7085580
31 January 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6900713
13 November 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6855267
14 August 2019 Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6785488
17 May 2019 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6686808
12 December 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6596560
21 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6585146
21 September 2017 Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6272224
6 February 2017 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6087838
3 November 2015 Administrative Inspection · COI Inspection · DAPI Audit · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5756038
20 July 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5191685
20 June 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4894342
13 July 2012 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4377732
24 May 2012 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4321122
30 January 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4290812
12 September 2010 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 3847821
15 July 2009 Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3535581
15 April 2009 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3453216
30 March 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3457065
17 March 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3435208
13 March 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3434611
25 June 2008 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3247831
12 July 2007 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2992747
26 April 2007 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2916545
22 January 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2860035
26 April 2006 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2634310
1 January 2006 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 2559413
11 September 2005 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2492559
30 May 2005 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2374934
6 April 2005 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2349326
3 June 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2093865
17 July 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1855394
27 May 2003 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1811402
18 June 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1631266
16 May 2001 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1444528
10 April 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 139182
27 February 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1060259
14 February 2001 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361970
13 February 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 113082
4 August 2000 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1450512
27 April 2000 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 819369
7 March 2000 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1046301
25 February 2000 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378958
15 February 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 189034
16 September 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1391118
24 June 1999 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1079315
14 May 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378690
28 August 1998 Plan Review "T" Boat · Hull Examination · Initial Certification · Construction Oversight
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1393010
14 December 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1183714
10 September 1993 Initial Construction-Excluding Oversight
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 834624

Deficiency record · 64

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Port and starboard Hydraulic pump hose lines forward of both engines worn and wasted. Both hoses require renewal. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2025
Resolution: Hydraulic Hose renewed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 October 2025 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by table 46 CFR 181.500(a)and other provisions of this section. Vessel carries (04) 10 B:C portable fire extinguishers. Vessels COI requires 1-10 B:C and 2-40 B:C. Provide (02) 40 B:C's as required by COI. 46 CFR 181.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2025
Resolution: (02) 40 B:C Fire extinguishers installed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 October 2025 Resolved
At inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each hydrostatic release unit (HRU) to determine that it is in compliance with the servicing and usage requirements of 185.740 of this chapter. Hydrostatic release for EPIRB expired. Install new HRU. 46 CFR 176.808(a)(5)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2025
Resolution: Hydrostatic release unit renewed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 October 2024 Resolved
At each inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the inspection and operation of all watertight closures in decks. Starboard engine hatch support rod, outboard side plate detached from frame and port forward hatch support rod broken. Both require repair or replacement. 46 CFR 176.802(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2024
Resolved 6 November 2024
Resolution: Starboard engine hatch and port forward hatch strut (support rods) replaced.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 October 2024 Resolved
A duct must be of rigid permanent construction, made of the same material as the hull or of noncombustible material. Provision must be made for closing all exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Engine compartment vent openings require closing mechanism. Blocking vent opening with a rag is not accepted. 46 CFR 182.460(h)(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2024
Resolved 6 November 2024
Resolution: New fabricated aluminum vent closures installed on to vessel.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 15 October 2024 Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited the operator must secure each Type I or Type II device in a manner which prevents discharge. Acceptable methods include: Padlocking the seacock in the closed position. MSD overboard discharge valve located in head unsecured. Requires new padlock. 33 CFR 159.7(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2024
Resolved 6 November 2024
Resolution: Padlock installed at MSD discharge valve.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 15 October 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit on board found with expired contents and unsuitable condition. Requires replacement. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2024
Resolved 6 November 2024
Resolution: New CG approved first aid kit installed on vessel
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 October 2024 Resolved
A vessel on an oceans, coastwise, or limited coastwise route must carry (1)Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q and(2)Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter. Vessels distress signals found expired. 46 CFR 180.68(a)(1)(2)
Action required: 10 - Deficiency Rectified
Resolved 15 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel COI calls for 38 adult like jackets. 37 counted on board. Requires 01 additional. 46 CFR 180.71(a)
Action required: 10 - Deficiency Rectified
Resolved 15 October 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel does not have any means to test for presence of alcohol. 46 CFR 4.06-15 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2024
Resolved 15 December 2023
Resolution: Test devices provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2023 Resolved
The employer shall provide an Employee Assistance Program for all crewmembers that includes both education and training on the effects and consequences of drug and alcohol use. Crewmember must receive training. Vessel's O/O has established an Employee Assistance Program as part of the company's chemical testing program, but has not completed the program. Provide satisfactory evidence of an Employee Assistance Program training for crew. 46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2024
Resolved 15 December 2023
Resolution: Training provided.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 December 2023 Resolved
Each vessel must be equipment with at least two operable portable battery lights and one for each engine space. Vessel does not have light for each engine space. Provide portable lights. 46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2024
Resolved 13 December 2023
Resolution: Portable lights provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 December 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's stbd fuel shutoff valve did not fully close. Provide fully operational fuel shutoff. 46 CFR 182.455(b)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2023
Resolution: Fuel shutoff operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2022 Resolved
Machinery and equipment installed must be suitable for the vessel and its operation. Hydraulic hose fittings both port and starboard showing signs of corrosion. Remove fitting and provide new approved J-1942 hydraulic hose and fitting. 46 CFR 182.100 46 CFR 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 7 November 2022
Resolution: New hoses and fittings provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 October 2022 Resolved
The Life Float Light must be attached by 3/8 inch lanyard, resistant to UV, and at least 18 feet in length. Life Float light line deteriorated and not of proper length. Provide new line that meets length. 46 CFR 180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 4 November 2022
Resolution: New line provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 October 2022 Resolved
Ring buoy must be fitted with a lifeline 60 ft in length, be at least 5/16 inch, be dark color if synthetic or a type certified to be resistant to deterioration from UV light. Line from ring buoy deteriorated. Provide new line. 46 CFR 180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 4 November 2022
Resolution: New line provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 October 2022 Resolved
Life float painter must be at least 100 ft in length, be of a dark color if synthetic, or of a type certified to be resistant to deterioration from UV light, and be stowed in a way that it runs out freely when the life float floats away. Painter deteriorated. Provide new painter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 4 November 2022
Resolution: New painter provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 October 2022 Resolved
Each survival craft must be secured by a painter with a float-free link permanently attached to the vessel. Weak link(float free device)did not have tag showing its ability to float-free. Provide weak link with appropriate tag. 46 CFR 180.130(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 4 November 2022
Resolution: New weak link provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 October 2022 Resolved
Vessel must be provided with one fixed power bilge pump and one portable hand pump. Portable hand pump was leaking. Provide new portable hand pump. 46 CFR 182.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 7 November 2022
Resolution: New hand pump provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 October 2022 Resolved
Vessel does not currently meet the requirements of Work Instruction 31. Mandated crew posted on COI may not enter the water or act as lifeguard until policy and procedure provided. Provide written procedure. 46 CFR 176.100(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2022
Resolved 2 November 2022
Resolution: Work Instruction 31 procedures provided.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 December 2021 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Crewmembers from the HOKUA reported sucking the spring line into the portside jet drive which caused an approximate one inch wide by seven inch crack in the port side grate and is splintering approximately one half inch into the hull. Vessel must be hauled out, damage assessment conducted and permanent repairs made to engine and/or hull.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2021
Resolved 27 December 2021
Resolution: Repairs made, sea trials conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 November 2021 Resolved
Vessel must be equipped with portable lights at the operating station and access to the machinery space. No portable lights on vessel. Provide dedicated portable lights for operating station and engine space. 46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 5 November 2021
Resolution: Lights provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 November 2021 Resolved
Installation of portable fire extinguisher must be in accordance with manufacture. Extinguisher not placed in bracket. Provide bracket for lower forward fire extinguisher. 46 CFR 181.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 5 November 2021
Resolution: Extinguisher provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 November 2021 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each machinery space. Visual indication of high water not operational at operating station for starboard engine room. Provide operational visual indicator at operating station for stbd engine room. Conduct and rounds every 30 minutes until operational. Rectify within 14 days. 46 CFR 182.530
Action required: 705 - Other - as specified
Due 16 November 2021
Resolved 15 November 2021
Resolution: Visual indicator operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 November 2021 Resolved
All electrical equipment must be suitable for the voltage and current. Dead end wires found behind helm. Remove dead end wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 15 November 2021
Resolution: Dead end wires removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel. 46 CFR 16.401(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 29 November 2021
Resolution: Drug training completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 October 2020 Resolved
Starboard engine room bilge high water visual indicator at helm not operational. Provide operational high water visual indicator at helm.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 27 November 2020
Resolution: Indicator operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 October 2020 Resolved
Gasoline cans located in lazarette. Remove hazardous cans from vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 27 November 2020
Resolution: Gasoline cans removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2020 Resolved
Hot water pump (soda pump) in starboard battery space not secured. Mount pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 27 November 2020
Resolution: Pump secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 28 October 2020 Resolved
02 hatches on forward deck cracked. Provide hatches that are not cracked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 29 December 2020
Resolution: New hatches installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 October 2020 Resolved
Fuel vent missing proper 30x30 screen. Provide 30x30 screen at fuel vent opening.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 27 November 2020
Resolution: Screen provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 October 2020 Resolved
Aft deck railing and entrance railing not meeting 39.5 inch requirement. Provide railing that meets 39.5 inch height requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2020
Resolved 27 November 2020
Resolution: Rail provided.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 November 2019 Resolved
Life float light was extinguished. Provide functional light in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2019
Resolved 11 February 2020
Resolution: Light repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2019 Resolved
Stbd emergency fuel valve did not close completely. Repair in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 11 February 2020
Resolution: Valve closes completely.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 November 2019 Resolved
Stbd running light was extinguished. Repair in accordance with 46 CFR 176.816. Vessel limited to day light operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 February 2020
Resolution: Stbd running light repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 November 2019 Resolved
Radio Safety Certificate was not provided. Provide in accordance with 46 CFR 184.502.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 11 February 2020
Resolution: Certificate provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 November 2019 Resolved
VHF DSC radio function was not programmed. Prove function in accordance with 46 CFR 184.502.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 11 February 2020
Resolution: DSC VHF radio function programmed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 August 2019 Resolved
Port installed extinguishing system audible and visual alarm did not function at operating station when tested. Prove correct operation in accordance with 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2019
Resolved 13 November 2019
Resolution: System test satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 November 2018 Resolved
Stbd Fireboy system did not secure engine after activation. Prove proper function of Fireboy system in accordance with 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2018
Resolution: System operates correctly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 November 2018 Resolved
Port Fireboy system did not allow engine to start after activation. Prove proper function of Fireboy system in accordance with 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2018
Resolution: System operates correctly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 November 2018 Resolved
Cabin and operating station portable extinguishers were not mounted. Mount in accordance with 46 CFR 181.520.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2018
Resolution: Extinguishers mounted.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 6 February 2017 Resolved
Prove proper operation of port and STBD Fireboy pull cable and shutdown switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2017
Resolution: Fireboy system operating properly.
Lifesaving › Lifefloat › Float Free
Issued 6 February 2017 Resolved
Provide current hydrostatic release for Lifefloat and Epirb.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2017
Resolution: New hydrostatic releases are installed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 February 2017 Resolved
Conduct drill in presence of CG Marine Inspector.
Due 3 March 2017
Resolved 10 February 2017
Resolution: Drills were conducted at pier due to weather and Crew conducted U/W next day.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 6 February 2017 Resolved
Provide proof of monthly required lifesaving equipment maintenance and quarterly drills.
Due 1 June 2017
Resolved 13 October 2017
Resolution: Provided.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 5 November 2015 Resolved
Epirb battery has expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2015
Resolution: Epirb battery was replaced.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 20 June 2014 Resolved
Provide Employee Assistance Program information to crew and employees in a public location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 18 May 2015
Resolution: Drug program is in place and crew knows were the EAP information is.
Documentation › Markings/Placards › Official Number (US)
Issued 20 June 2014 Resolved
Mark the vessel's Official Number on some clearly visible interior structural part of the hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2014
Resolved 18 May 2015
Resolution: Vessel installed offical number placard in engine room stbd side.
Communications › Radio Communications › EPIRB
Issued 13 July 2012 Resolved
Provide non-expired hydro for EPIRB.
Action required: 705 - Other - as specified
Due 21 July 2012
Resolved 16 July 2012
Communications › Radio Communications › EPIRB
Issued 13 July 2012 Resolved
Provide NOAA reg for EPIRB.
Action required: 705 - Other - as specified
Due 17 July 2012
Resolved 16 July 2012
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 15 April 2009 Resolved
Renew impeller on port side jet outdrive.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 15 July 2009
Documentation › Markings/Placards › Capacity Marking
Issued 12 July 2007 Resolved
Second deck was missing a capacity placard.
Due 12 July 2007
Resolved 13 July 2007
Engineering › Thrusters › Pump
Issued 11 September 2005 Resolved
Effect repairs to the hydraulic pump used to control the Starboard steering bucket on the jet drive.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2005
Resolved 13 September 2005
Resolution: Changed the plastic gear on connecting the belt drive to the hydraulic pump.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 3 June 2004 Resolved
Provide materials for DAPI audit prior to carrying passengers.
Condition: Unknown
Due 3 June 2004
Resolved 16 June 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 3 June 2004 Resolved
Install manual pull cables for both port and starboard fixed fire systems located in engine room.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2004
Resolved 16 June 2004
Lifesaving › Buoyant Apparatus
Issued 3 June 2004 Resolved
Provide sea painter and waterlight for 22 man lifefloat. LEGACY COMPONENT DESC: sea painter and water light
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2004
Resolved 16 June 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 July 2003 Resolved
Provide adequate First Aid Kit IAW 46 CFR 184.710. LEGACY COMPONENT DESC: First Aid Kit
Due 18 July 2003
Resolved 3 June 2004
Construction/Loadline › Markings
Issued 17 July 2003 Resolved
Install vessel's name and hailing port in appropriate locations IAW 46 CFR 185.602 LEGACY COMPONENT DESC: Vessel Name/Home Port
Due 18 August 2003
Resolved 3 June 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 17 July 2003 Resolved
Replace all fuel lines to meet J-1942 standards IAW 46 CFR 182.720(e). LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 18 August 2003
Resolved 3 June 2004
Communications › Radio Communications
Issued 17 July 2003 Resolved
Install new hydrostatic release for EPIRB IAW 46 CFR 180.64 prior to carrying passengers. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 June 2004
Engineering › Bilge Water Management System
Issued 17 July 2003 Resolved
Install working bilge pump in stbd aft compartment, prior to carrying passengers. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 June 2004
Engineering › Steering Gear System
Issued 17 July 2003 Resolved
Replace alignment cable in stbd jet-drive IAW176.814. LEGACY COMPONENT DESC: Alignment cable
Condition: Improper/Lack of Maintenance
Due 18 August 2003
Resolved 3 June 2004
Lifesaving › Lifebuoys
Issued 17 July 2003 Resolved
Replace grabline on ring lifebuoy IAW 180.70 prior to carrying passengers. LEGACY COMPONENT DESC: Grabline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 June 2004
Construction/Loadline
Issued 14 February 2001 Resolved
Complete repairs as approved on damaged fiberglass on forward and aft sidesof centerline bulwark at transom attachment._x001C_ Repair prior to carriage of passengers.
Condition: Unknown
Due 14 February 2001
Resolved 14 February 2001

Casualty record · 3

30 March 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3457065
30 July 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3832921
30 January 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4290812
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.