Records from 1985 to 2012. Most recent: inspection, 11 June 2012.
Inspection history · 43
11 June 2012
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4340538
5 October 2010
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3858778
30 March 2010
Drydock Extension · Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3714695
23 December 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3656315
1 July 2009
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3520944
2 October 2008
Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3337001
25 June 2008
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3247527
13 January 2004
Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1983261
11 July 2001
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1397673
10 July 2001
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1068756
22 February 2001
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1057986
29 July 2000
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 150922
19 July 2000
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1054422
22 June 2000
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1389122
20 April 2000
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1451544
8 April 1999
COI Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1372844
9 February 1999
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1461223
30 March 1998
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 786218
11 April 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1094878
9 January 1997
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1106405
26 March 1996
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1078338
12 April 1995
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 871052
27 February 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 871051
23 January 1995
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 867584
27 January 1994
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1422325
15 November 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135866
21 September 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1148707
7 April 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 836625
28 January 1993
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1356211
17 September 1992
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1270517
7 February 1992
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 950790
1 March 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932666
8 February 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 908323
20 February 1990
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 922103
19 May 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039961
28 March 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202251
5 April 1988
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030159
3 August 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1033403
18 March 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1324119
30 May 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 987007
8 April 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309251
12 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 981193
12 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287778
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 11 June 2012
No resolution recorded
IBA removed from vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Hull Plating
Issued 30 March 2010
Resolved
Make permanent repairs to hole in side shell port forward engine room and holes in side shell in port side lazzerrette these areas will need to be inserted.
Condition: Improper/Lack of Maintenance
Due 9 April 2010
Resolved 12 July 2010
Resolution: repaired sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 March 2010
Resolved
Conduct Dry-docking to the satisfaction of attending Marine Inspector prior to carrying passengers.
Due 9 April 2010
Resolved 12 July 2010
Resolution: dry-dock inspection conducted sat.
Operations/Management › Pollution › Removal Methods/Procedures
Issued 30 March 2010
Resolved
Remove flammables (paint, gasoline power washer, spillage of flam liquid in bilge) from space and stow or properly disposed of.
Due 9 April 2010
Resolved 12 July 2010
Resolution: All flammables removed sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 30 March 2010
Resolved
Starboard exhaust pipe, repair hole in pipe located just fwd of drain plug, outboard side of pipe.
Condition: Improper/Lack of Maintenance
Due 9 April 2010
Resolved 12 July 2010
Resolution: pipe welded sat.
Engineering › Bilge Water Management System › Piping
Issued 30 March 2010
Resolved
Replace wasted bilge piping IWO void #4 port side. All bilge piping will need to be tested in presents of CG Inspector following repair.
Condition: Improper/Lack of Maintenance
Due 9 April 2010
Resolved 12 July 2010
Resolution: bilge piping repaired and tested sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 July 2009
Resolved
PROVIDE AND INSTALL DECK LIGHT CAGES
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 July 2009
Resolved
PROVIDE THE VESSELS CURRENT COD.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2009
Resolved
REMOVE ALL EXTENION CORDS AND PROPERLEY HARD WIRE THE EQUIPMENT.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Construction/Loadline › Structures › Superstructure
Issued 1 July 2009
Resolved
CROP AND RENEW FRAME MEMBERS AT THE INTERSECTION OF THE MAIN DECK AND THE SIDE SHELL OF THE VESSEL.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 July 2009
Resolved
PROVIDE AND INSTALL 5 CHILD LIFE JACKET SIGN.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2009
Resolved
REMOVE THE ELECTRICAL OUTLET IN THE BALLAST VOID AND TERMINATE THE WIREING AT THE ELECTRICAL DISTRIBUTION PANEL.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Construction/Loadline › Hull › Hull Plating
Issued 1 July 2009
Resolved
CROP AND RENEW THE WASTED HULL PLATING IN THE BALLAST VOID ON THE PORT SIDE AT THE SHEER AS NEEDED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Construction/Loadline › Structures › Deck Plating
Issued 1 July 2009
Resolved
CROP AND RENEW THE WASTED DECK UNDER THE YELLOW STANTIONS ON THE STERN.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 1 July 2009
Resolved
REMOVE ALL SPACE HEATERS.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Construction/Loadline › Structures › Superstructure
Issued 1 July 2009
Resolved
CROP AND RENEW THE WASTED STAIR RISER AT THE MAIN DECK, STARBOARD SIDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 July 2009
Resolved
PROVIDE AND INSTALL 2 EMERGENCY LIGHTS (12V) IN THE ENGINEROOM.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Lifesaving › Lifebuoys › Serviceable
Issued 1 July 2009
Resolved
PROVDE AND INSTALL RETRO TAPE ON THE 2 STERN LIFE RINGS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2009
Resolved
110V EXTENSION CORD AT THE SWITCHBOARD IN THE ENGINE ROOM (ER), PERMANETLY WIRE.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 July 2009
Resolved
REPAIR THE LEAK ON THE STBD GENERATOR JACKET WATER COOLER NIPPLE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Engineering › Sea-water System (primary cooling) › Valve
Issued 1 July 2009
Resolved
REPAIR THE INOP SEA CHEST VALVE FOR THE GENERATOR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Engineering › Bilge Water Management System › Valve
Issued 1 July 2009
Resolved
LABLE THE BILGE VALVE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Engineering › Lubricating Oil Service System › Pump
Issued 1 July 2009
Resolved
MDE OIL SUMP PUMP, HARD WIRE SWITCH.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 1 July 2009
Resolved
MDE PORT SIDE, REPLACE THE AIR INTAKES.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Electrical › Electric Generation Source (service) › Generator
Issued 1 July 2009
Resolved
PROVE PROPPER OPERATION OF THE PORT GENERATOR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 July 2009
Resolved
PROPERLY REPAIR THE SOFT PATCH ON THE MDE REDUCTION GEAR COOLING LINE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 1 July 2009
Resolved
PROVIDE AND INSTALL A HANDLE FOR THE SHAFT WATER SEAL REMOTE SHUT OFF VALVE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Accommodation/Occupational Safety › Heating › Piping
Issued 1 July 2009
Resolved
REPLACE THE FURNACE EXHAUST LAGGING.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 21 July 2009
Documentation
Issued 22 June 2000
Resolved
PROVIDE A COPY OF THE DRUG TESTING ENROLLMENT LETTER TO THE MSO BOSTON.
Condition: Unknown
Due 29 June 2000
Resolved 27 June 2000
Engineering
Issued 22 June 2000
Resolved
RELAG PORT MAIN ENGINE EXHAUST PIPING INCLUDING TURBO'S.
Condition: Unknown
Due 29 June 2000
Resolved 27 June 2000
Lifesaving
Issued 22 June 2000
Resolved
PROVIDE WATER LIGHTS FOR EACH BUOYANT APPARATUS.
Condition: Unknown
Due 29 June 2000
Resolved 27 June 2000
Fire Fighting
Issued 22 June 2000
Resolved
LABEL INSTRUCTIONS FOR FIXED CO2 FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 29 June 2000
Resolved 27 June 2000
Lifesaving
Issued 22 June 2000
Resolved
CONDUCT FIRE AND MAN OVERBOARD DRILLS IN THE PRESENCE OF AN COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 29 June 2000
Resolved 27 June 2000
Fire Fighting
Issued 30 March 1998
Resolved
PRIOR TO CARRYING PASSENGERS, THE FIXED CO2 SYSTEM BOTTLES MUST BE HYDROSTATICALLY TESTED BY A SERVICING COMPANY. THE SYSTEM PIPING/CONTROLS MUST BE TESTED/EXAMINED IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Construction/Loadline
Issued 9 January 1997
Resolved
Clean bilge strainer in void #2 (from forward).
Condition: Unknown
Due 9 February 1997
Resolved 9 July 1997
Lifesaving
Issued 9 January 1997
Resolved
Repair leaking valve on lube oil tank in engineroom.
Condition: Unknown
Due 9 February 1997
Resolved 9 July 1997
Lifesaving
Issued 9 January 1997
Resolved
Provide guards for sight glass on lube oil tank.
Condition: Unknown
Due 9 February 1997
Resolved 9 July 1997
Construction/Loadline
Issued 9 January 1997
Resolved
Crop & renew lower 12 inches of transverse deep frame under port shaft, approximately 30 inches long.
Condition: Unknown
Due 9 February 1997
Resolved 9 July 1997
Deck/Cargo
Issued 9 January 1997
Resolved
Renew approximately 10 feet of the begining of the anchor cable.
Condition: Unknown
Due 9 February 1997
Resolved 9 July 1997
Lifesaving
Issued 9 January 1997
Resolved
Tighten union on hydraulic line in void #1 (from forward).
Condition: Unknown
Due 9 February 1997
Resolved 9 July 1997
Deck/Cargo
Issued 9 January 1997
Resolved
Remove steel where chafing on the anchor cable.
Condition: Unknown
Due 9 February 1997
Resolved 9 July 1997
Construction/Loadline
Issued 9 January 1997
Resolved
Continuously weld transverse deck frames in aft centerline ballast tank. Reweld cracked welds where overhead meets frames in port void.
Condition: Unknown
Due 9 February 1997
Resolved 9 July 1997
Electrical
Issued 27 January 1994
Resolved
REMOVE DEAD-ENDED WIRING FROM INSIDE THE PILOTHOUSE CONSOLE.
Condition: Unknown
Due 24 February 1994
Resolved 24 February 1994
Lifesaving
Issued 28 January 1993
Resolved
PAROVIDE 188 ADDITIONAL ADULT LIFE PRESERVERS.
Condition: Unknown
Due 31 March 1993
Resolved 24 February 1993
Lifesaving
Issued 28 January 1993
Resolved
PROVIDE 25 ADDITIONAL CHILD SIZE LIFE PRESERVERS.
Condition: Unknown
Due 31 March 1993
Resolved 24 February 1993
Electrical
Issued 28 January 1993
Resolved
SHOW PROPER OPERATION OF GENERATOR LOW LUBE OIL ALARM.
Condition: Unknown
Due 31 March 1993
Resolved 24 February 1993
Documentation
Issued 28 March 1989
Resolved
OBTAIN AND PLACE ONBOARD A VALID UPDATED FCC CERTIFICATE.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Navigation
Issued 28 March 1989
Resolved
OBTAIN AND PLACE ONBOARD A COMPASS DEVIATION CARD.
Condition: Unknown
Due 28 March 1989
Resolved 28 March 1989
Engineering
Issued 18 March 1987
Resolved
INSTALL LAGGING ON BOTH MAIN ENGINES AND STARBOARD GENERATOR EXHAUST PIPING.
Condition: Unknown
Due 18 March 1987
Resolved 18 March 1987
Navigation
Issued 18 March 1987
Resolved
PLACE ONBOARD ONE COPY EACH OF THE INTERNATIONAL - INLAND RULES OF THE ROAD AND SMALL PASSENGER REGULATIONS ( 46 CFR 175).
Condition: Unknown
Due 18 March 1987
Resolved 18 March 1987
Navigation
Issued 18 March 1987
Resolved
INSTALL OUT OF COMMAND LIGHTS IN ACCORDANCE WITH THE INTERNATIONAL - INLAND RULES OF THE ROAD.
Condition: Unknown
Due 18 March 1987
Resolved 18 March 1987
Fire Fighting
Issued 18 March 1987
Resolved
REPLACE TWO BROKEN SPRINKLER HEADS ON THE VEHICLE DECK SPRINKLER SYSTEM.
Condition: Unknown
Due 18 March 1987
Resolved 18 March 1987
Navigation
Issued 30 May 1986
Resolved
PROVIDE ONE ANCHOR LIGHT IN ACCORDANCE WITH THE INTERNATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986