MAURY USCG vessel records
← All vessels

ALTAIR

ALTAIR is a 1973 public vessel, unclassified. The Coast Guard has recorded 19 inspections since 2016, most recently in September 2024, along with 21 deficiencies and 1 casualty investigation in 2019.

Records from 2016 to 2024. Most recent: inspection, 9 September 2024.

Built
1973
Last inspected
9 September 2024
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 September 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7315571
Flag
UNITED STATES
Maury page id
psix-47638

Documentation record

Registered dimensions (L × B × D)892.2 ft × 105.5 ft × 59.1 ft
Registered tonnagegross 48,524 / net 30,576
ITC dimensions (L × B × D)Not recorded
ITC tonnagegross 49,262 / net 18,314
BuilderRHEINSTAHL NORDSEEWERKE · EMDEN, GERMANY · built 1973
Hull materialSteel
PropulsionSteam Turbine
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsRegistry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPublic Vessel, Unclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48524 - Regulatory (Subpart C or D), Gross Ton
49262 - Convention (Subpart B), Gross Ton
55350 - Displacement, Gross Ton
30576 - Regulatory (Subpart C or D), Net Ton
18314 - Convention (Subpart B), Net Ton
32295 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

9 September 2024 ISM Oversight · TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7999252
31 July 2024 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7965872
14 August 2023 ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7757836
15 August 2022 ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7525002
15 July 2022 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7507568
12 July 2021 ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7179038
15 June 2021 TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7225984
7 April 2021 MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7170209
29 April 2020 ACP Additional Oversight – Risk Assessment · Re-Inspection · Administrative Inspection · ACP Annual Oversight · ACP COI Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6945760
7 April 2020 ACP Drydock Oversight · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6936665
11 December 2019 Drydock Extension
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6917760
2 December 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6870849
25 September 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6821463
17 April 2019 Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6665338
28 November 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6588665
28 March 2018 MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6379842
27 October 2017 Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6300434
29 March 2017 MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6109848
9 May 2016 ACP Annual Oversight
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5831448

Deficiency record · 21

01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 17 April 2019 Resolved
During an inspection of the port lifeboat, found the search light battery was dead, and upon asking for a new battery and the 2 required spare bulbs, none were found, flares were relocated temporarily to the bridge and will be returned prior to departure, expanded and crew was not familiar that a lifeboat equipment inventory checklist was needed, looked into the vessel SMS (called Safety Quality Environmental) which referenced the lifeboat manufacture manual, inside was a general inventory equipment table, did not state the required number/amount of equipment needed. Chief Mate then stated the manufacturer verifies lifeboat equipment, approx 1 year ago, evident that #1, the crew has not conducted the monthly lifeboat equipment checks for both lifeboats as they should be, and #2, a checklist was never created since the new lifeboats were installed approx 1 year ago. This indicates missing gaps in the vessel's SMS implementation.
Action required: 10 - Deficiency Rectified
Resolved 17 April 2019
Resolution: Accepted by Class, finding number within ABS Statutory Survey Report Number NO3599101
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 April 2019 Resolved
Fire station 22 “Y” gate valve on station frozen hard to open. This system of fire stations is on the vessels PMS schedule as a quarterly inspection and was last completed on 11Dec2018. The PMS includes detailed instructions on how to clean and service each valve. It is questionable if this station was missed or that it will corrode up after only a quarter of sitting idle. If it is the latter then the PMS Schedule needs to be changed to a monthly PMS Cycle.
Action required: 10 - Deficiency Rectified
Resolved 17 April 2019
Resolution: Accepted by Class, finding number within ABS Statutory Survey Report Number NO3599101
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 April 2019 Resolved
On the forecastle deck, the fire/ventilation damper closures were deficient. Many of the closures had been PMS’d as evident of the fresh grease on fittings, but not all fittings were satisfactory. Dog wing nuts on them were frozen and could not be moved, broken dog bolts on the closures. In checking the PMS schedule for these damper closures, it was discovered that these type closures are not on a specific PMS category, internal fire dampers are but not the exterior ones. This PMS item will need to be added to their schedule.
Action required: 10 - Deficiency Rectified
Resolved 17 April 2019
Resolution: Accepted by Class, finding number within ABS Statutory Survey Report Number NO3599101
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 April 2019 Resolved
On the upper deck FWD house, the life raft stations on both the port and stbd side of the vessel were examined and deficiencies were found. The removable stanchions on the outboard side of each raft, are not so removable. The FWD stanchion on each raft was frozen in place, rusted with no apparent PMS for maintain these pieces. The PMS schedule for the life rafts was examined and nowhere in the PMS is any mention of checking the stanchions that are removable for manual deployment of the rafts. This will have to be added even though the vessel rep. stated it should be common sense to check them.
Action required: 10 - Deficiency Rectified
Resolved 17 April 2019
Resolution: Accepted by Class, finding number within ABS Statutory Survey Report Number NO3599101
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 April 2019 Resolved
Forecastle deck FWD of the FWD house centerline watertight door, which is also an egress route from the house was not working properly. The center top dog on the door took almost the full weight of a person on it to open the door. There is a PMS for these doors but not being followed for some reason. Attention to the PMS Quality needs to be stepped up.
Action required: 10 - Deficiency Rectified
Resolved 17 April 2019
Resolution: Accepted by Class, finding number within ABS Statutory Survey Report Number NO3599101
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 April 2019 Resolved
Upon testing of the 3 sliding watertight doors, bridge watertight door panel/diagram lights not functioning and lights installed backwards, after corrections and then testing of all doors, panel satisfactory, issue was not identified before our inspection. Same issue found during previous CG inspection of Mar 2018.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 April 2019
Resolved 17 April 2019
Resolution: fixed on the spot.
Lifesaving › Inflatable Liferafts › Float Free
Issued 29 March 2018 Resolved
Newly installed liferafts were not installed in a float free arrangement in that the painter lines were attached directly to the hull of the ship vice the weak link.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2018
Resolution: Rcvd report from ABS that liferafts were reinstalled correctly.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 March 2018 Resolved
Several Life ring lanyards that attach the floating light were deteriorated and in need of replacement.
Action required: 705 - Other - as specified
Resolved 30 March 2018
Resolution: Accepted as conditions of class.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 28 March 2018 Resolved
Several weatherdeck outlets were missing covers.
Action required: 705 - Other - as specified
Resolved 30 March 2018
Resolution: Accepted as condition of class.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 March 2018 Resolved
Firefighting air bottles stowed on shelf with necks lying across knife edge of shelf creating potential missle hazard.
Action required: 705 - Other - as specified
Resolved 30 March 2018
Resolution: Accepted as condition of class.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 28 March 2018 Resolved
Weatherdeck house to steering room did not create a watertight envelope, adjust to secure correctly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2018
Resolution: RCVD confirmation from class that adjustments made and visually verified.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 28 March 2018 Resolved
Indicator lights on bridge for all watertight doors in E/R were out.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2018
Resolution: Accepted as condition of class. Verified corrected by MI on 29Mar2018.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 March 2018 Resolved
Several distribution panels had incorrect or missing labeling.
Action required: 705 - Other - as specified
Resolved 30 March 2018
Resolution: Accepted as condition of class.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 March 2018 Resolved
Forward superstructure workshop had dead end wiring that was not correctly capped.
Action required: 705 - Other - as specified
Resolved 30 March 2018
Resolution: Accepted as condition of class
Stability › Watertight Integrity › Weathertight Enclosure
Issued 28 March 2018 Resolved
noted several ventillation enclosures on weatherdeck did not secure correctly and/or did have appropriate nuts for closure.
Action required: 705 - Other - as specified
Resolved 30 March 2018
Resolution: Accepted as condition of class
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 28 March 2018 Resolved
Forward stair tower door did not close correctly.
Action required: 705 - Other - as specified
Resolved 30 March 2018
Resolution: Accepted as condition of class
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 28 March 2018 Resolved
X3 fire extinguishers where not properly secured, the brackets being damaged.
Action required: 705 - Other - as specified
Resolved 30 March 2018
Resolution: Accepted as Condition of Class
Electrical › Electrical Distribution System (service) › Switchboard
Issued 28 March 2018 Resolved
Most of the Engine Room gauges had not been calibrated since 2009.
Action required: 705 - Other - as specified
Resolved 30 March 2018
Resolution: Accepted as Condition of Class
Construction/Loadline › Structures › Scuttle
Issued 28 March 2018 Resolved
Hatch to 'B' deck, hold #3 recently had spring replaced but needs adjustment to operate correctly.
Action required: 705 - Other - as specified
Resolved 30 March 2018
Resolution: Accepted as Condition of Class
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 28 March 2018 Resolved
Several fire boundary doors found with holdbacks in place. Remove all hold back on fire boundary doors.
Action required: 705 - Other - as specified
Resolved 30 March 2018
Resolution: Accepted as Condition of Class
Electrical › Lighting (service) › Lighting Fixture
Issued 28 March 2018 Resolved
Verify paint locker explosion proof lights/switches will operate as intended. Currently it appears that the gas release holes have been painted over.
Action required: 705 - Other - as specified
Resolved 30 March 2018
Resolution: Accepted as Condition of Class

Casualty record · 1

2 December 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6870849
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.