09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 1 October 2024
Resolved
The Inspection shall be such as to insure that the vessel, as regards to structure... and other equipment, is in satisfactory condition and fit for the service for which it is intended, and that it complies with the applicable regulations or such vessels... The catwalk for the crane has several areas that are wasted and broken welds. Barge rep was on scene and USCG MI pointed out the areas to be crop and renewed to original by October 31st, 2025, during Class survey. (705)
46 CFR 91.25-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2025
Resolved 19 September 2025
Resolution: Welds were repaired and verified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2024
Resolved
The installations of all systems of an electrical engineering or interior communication nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter J of this chapter. Battery in machinery space missing cover and battery on deck for hydraulic power unit not in a battery box.
46 CFR 96.05-1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2024
Resolved 14 October 2024
Resolution: O/O submitted photos batteries covered and in a battery box.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 14 July 2023
Resolved
The pressure portions of pressure vessels shall normally have a corrosion allowance of one-sixth of the calculated thickness, or one-sixteenth inch, whichever is smaller added to the calculated thickness as determined by the applicable design formula. The #1 Air Receiver had excessive corrosion on the top 1/3 portion of the interior of the pressure vessel. The operator was unable to provide the U1A to verify the corrosion allowance. Repair with a pre-approved repair proposal submitted to the marine inspector or replace with a Coast Guard approved air receiver that meets 46 CFR 54.01-5(c)(3).
46 CFR 54.01-35
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2023
Resolution: #1 Air receiver replaced with new unit. U1A provided and reveiwed, SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2023
Resolved
Each cable installation must meet sections 25 except 25.11 of IEEE 45-2002. The cables and wire in the overhead of the engine space were not properly supported by metal brackets and some lights were found to be wire tied to the brackets instead of properly supported.
46 CFR 111.60-5(a)(1)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2023
Resolution: Support brackets installed. SAT.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 14 July 2023
Resolved
The renewal survey shall be such as to ensure that the structure, equipment, systems, fittings, arrangements and material fully comply with applicable requirements of Chapter 3 of this Annex. The vessel does not currently have on board: Bunker Delivery Notes for the current fuel oil; Fuel oil samples properly labeled and secured for the fuel oil on board; EIAPP for each engine over 130 KW; Technical Files for each engine over 130 KW. Correct prior to making an international voyage.
MARPOL 73/76 (2017) Annex VI Reg. 5.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2023
Resolution: Procedure for documenting and labelling fuel oil samples updated and reviewed. Vessel rep will follow established procedures and regs for all future handling of fuel oil. Vessel rep could not provide the EIAPP documents. IAPP not issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 July 2023
Resolved
Grab line. The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. Replace deteriorated lines on all lifebuoys.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2023
Resolved 14 July 2023
Resolution: New ring buoys were purchased and placed on board in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 July 2023
Resolved
Attachments and fittings. Lifejackets must have the following attachments and fittings: (i) Each lifejacket must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the lifejacket. Multiple lights inoperative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2023
Resolved 14 July 2023
Resolution: New lights were purchased and placed in service on the lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 July 2023
Resolved
vent outlets from all tanks which may emit flammable or combustible vapors, such as bilge slop tanks and contaminated drain tanks, must be fitted with a single screen of corrosion-resistant wire of at least 30 by 30 mesh, or two screens of at least 20 by 20 mesh spaced not less than one-half inch (13mm) nor more than 11/2 inches (38mm) apart. The clear area through the mesh must not be less than the internal unobstructed area of the required pipe. No flame screen on generator day tank.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2023
Resolved 14 July 2023
Resolution: Flame screens were replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 July 2023
Resolved
Remaining worklist items issued via email to vessel rep and uploaded into documents section.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2023
Resolved 27 July 2023
Resolution: Worklist items complete.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 November 2020
Resolved
If sediment was discharged within the jurisdiction of the United States, include the name and location of the facility where sediment disposal took place. The master, owner, operator, agent or person in charge of a vessel subject to this section must retain a signed copy of this information on-board the vessel for 2 years. Vessel representative was unable to provide USCG Inspectors with ballast water records as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 19 September 2025
Resolution: Vessel's ballast records in order.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 November 2020
Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern of the vessel under 67.123 of part 67 of this chapter. Vessel's lifebuoys required markings are severely faded/have been worn off. Rectify prior to vessel certification.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 19 September 2025
Resolution: Markings on Lifebuoy sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2020
Resolved
Lifejackets must be stowed as follows: Lifejackets must be readily accessible. Lifejackets were not stowed in designated stowage location. Rectify prior to vessel certification.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 19 September 2025
Resolution: Lifejackets has a designated area.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 November 2020
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens and meet the requirements of § 84.15. Navigation light screens were not painted matt black. Rectify prior to vessel certification.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 19 September 2025
Resolution: Navigation lights have black back panels.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2018
Resolved
Lifejackets must be readily accessible when stowed.
Action required: 66 - Prior to drilling or production operations
Due 28 December 2018
Resolved 10 December 2018
Resolution: O/O mitigate deficiency to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2018
Resolved
Each lifejacket must have a lifejacket light approved and attached to the lifejacket. The light was expired.
Action required: 66 - Prior to drilling or production operations
Due 28 December 2018
Resolved 10 December 2018
Resolution: O/O mitigated deficiency to the satisfaction of the attending Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 November 2018
Resolved
A current Federal Communications Commission (FCC) station license must be posted at the principal control point of each station. The FCC license was expired.
Action required: 66 - Prior to drilling or production operations
Due 28 December 2018
Resolved 10 December 2018
Resolution: O/O mitigated deficiency to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 November 2018
Resolved
Barge did not maintain a current and accurate transfer procedure for governing the tranfer of the fuel oil for the deck and miscellaneous engineering/deck equipment.
Action required: 705 - Other - as specified
Due 28 December 2018
Resolved 10 December 2018
Resolution: O/O mitigated deficiency to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 29 November 2018
Resolved
A valid Non-Tank Response Plan (NT-VRP) is required to be on board. The NT-VRP was not on board.
Action required: 66 - Prior to drilling or production operations
Resolved 30 November 2018
01 - Certificates & Documentation › 013 - Documents › Certificate or documentary evidence of financial security relating to shipowners liability
Issued 29 November 2018
Resolved
A vessel that is 300 gross tons must be able to present a valid Certificat of Financial Responsibility (COFR). COFR was not made available to inspector. Reviewed ECOFR.com and verified COFR is in good standing.
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 29 November 2018
Resolved
All vessels engaged in domestic voyages by sea shall be subject to the applicable Load Line requirements. The vessels Load Line certificate was expired. Operations are limited to inside the boundary line.
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
14 - Pollution Prevention › 147 - Anti-Fouling › AFS supporting documentation
Issued 29 November 2018
Resolved
Ships of 400 gros tons or more shall comply with Anti-Fouling systems convention. The AFS certificate was expired. Operations are limited to inside the boundary line.
Action required: 705 - Other - as specified
Resolved 4 December 2018
Documentation › Certificates/Documents › Stability Letter
Issued 12 December 2017
Resolved
A stablity booklet must be prepared for each vessel. No proof of a valid stabilty booklet was onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current certificate/document while onboard.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 12 December 2017
Resolved
A valid SOPEP is required to be onboard. Vessel did not provide a valid SOPEP or Non Tank Vessel Response Plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current cerificate/document while onboard.
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 12 December 2017
Resolved
Each operator or agent of a vessel with a capacity of 250 or more barrels shall designate, either by name or by position in the crew, the person in charge (PIC) of each transfer to or from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current cerificate/document while onboard.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 12 December 2017
Resolved
The vessel operator required to have transfer procedures shall require vessel personnel to use the transfer procedures for each transfer operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current cerificate/document while onboard.
Electrical › Electric Generation Source (service) › Generator
Issued 12 December 2017
Resolved
Make machinery space available and machinery operational to attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Space was made available and all machinery that was necessary was tested.
Personnel › Training › Lifeboatman
Issued 12 December 2017
Resolved
The barge's COI requires 01 certified Lifeboatman to be onboard when industrial personnel are onboard working. No proof of Lifeboatman training onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current certificate/document while onboard.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 December 2017
Resolved
Provide proof of enrollment in Drug and Alcohol Testing Program, and proof that Industrial Personnel onboard vessel are enrolled in Drug and Alcohol Testing Program.
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current certificate/document while onboard.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 12 December 2017
Resolved
Maintain a ballast water management (BWM) plan that has been developed specifically for the vessel.
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current certificate/document while onboard.
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 12 December 2017
Resolved
Lifejackets must be readily accessible when stowed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Life jackets were placed in an accessible area.
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 December 2017
Resolved
Every crewmember must participate in at least one abandon ship drill and one fire drill every month. There was no record of drills onboard.
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Vessel began documentig items in Log Book.
Documentation › Logs/Records › Logbook (official)
Issued 12 December 2017
Resolved
Vessel needs to maintain a logbook and records onboard for drills conducted and daily activity onboard vessel.
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Vessel is maintaining log book.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 8 March 2017
Resolved
Fuel oil transfer hoses shall be locked-out/tagged-out until hydrostatically tested IAW 46 CFR 156.170.
Action required: 705 - Other - as specified
Resolved 5 April 2018
Resolution: Attending marine inspectors cleared deficiencies during exam, when reviewing case work def was never cleared. Dating resolve date as date which case was reviewed, after discussing def with attending marine inspectors. Hose is no longer onboard.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 6 March 2017
Resolved
Properly dispose of all oil-soaked rags/absorbent pads. ID and repair sourses of oil leaks on all machinery.
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 10 April 2017
Resolution: Unauthorized equipment removed.
Engineering › Pressure Vessel › Pressure Gauge
Issued 6 March 2017
Resolved
Demonstrate proper operation of the pressure switch on the fwd-most air receiver in the machinery space.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Witnessed satisfactory test.
Documentation › Logs/Records › Declaration of Inspection
Issued 6 March 2017
Resolved
Provide a copy of the signed DOI for the last fuel oil transfer and a copy of the BDN.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Reviewed records and provided additional training to crew.
Electrical › Electric Generation Source (service) › Generator
Issued 6 March 2017
Resolved
Demonstrate proper operation of overspeed and loss of LOP shutdowns on each generator prime mover.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 24 April 2017
Resolution: Witnessed overspeed tests, reviewed technician service reports.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 March 2017
Resolved
Mount each fire extinguisher in a suitable approved bracket which provides quick and positive release of the extinguisher for immediate use.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified placement and brackets.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 March 2017
Resolved
Exhaust sys piping, including exhaust manifold, shall be provided with protective guards, jacketing, or covers wherever temp exceeds 200*F.
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 4 May 2017
Resolution: Verified all manifold exhaust jacketing in place.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 6 March 2017
Resolved
No flammable or combustible liquids may be stowed in any accommodation, control or services space (other than a paint locker). Move fuel samples to appropriate location.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified storage location of fuel samples.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 March 2017
Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified markings.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 March 2017
Resolved
Each self igniting light used with a lifebuoy needs to be attached to the body of the lifebuoy.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified placement.
Lifesaving › Lifebuoys › Serviceable
Issued 6 March 2017
Resolved
Replace all worn/broken grab lines.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified condition.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 6 March 2017
Resolved
Each lifejacket shall have a light and whistle firmly attached to the lifejacket.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified attachments.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 6 March 2017
Resolved
The liferaft must have a painter system providing a connection between the vessel and the liferaft and be arranged in a float-free arrangement.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified installation.
Documentation › Logs/Records › Drug Test Records
Issued 6 March 2017
Resolved
Provide proof of a vailid company enrollment in a drug and alcohol program.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified documentation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 March 2017
Resolved
Failure to complete the requierd annual or periodic inspection.
Action required: 705 - Other - as specified
Resolved 6 March 2017
Resolution: Sector NY attended for periodic inspection.