MAURY USCG vessel records Sign in
← All vessels

THOMAS W

THOMAS W is a 1976 industrial vessel. The Coast Guard has recorded 62 inspections since 1984, most recently in September 2025, along with 99 deficiencies and 1 casualty investigation in 2013.

Records from 1984 to 2025. Most recent: inspection, 19 September 2025.

Built
1976
Last inspected
19 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8758354 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-48888

Inspections, by type

…with no type recorded13
Years with a record 29 calendar years (1984–2025)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)225.1 ft × 78.1 ft × 14.3 ft
Registered tonnagegross 2,468 / net 2,468
ITC dimensions (L × B × D)216.0 ft × 78.0 ft × 15.0 ft
ITC tonnagegross 2,371 / net 711
BuilderPACECO · ALAMEDA, CA, UNITED STATES · built 1976
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portEVANSVILLE, IN
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2468 - Regulatory (Subpart C or D), Gross Ton
2371 - Convention (Subpart B), Gross Ton
2468 - Regulatory (Subpart C or D), Net Ton
711 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ALTAIR Public Vessel, Unclassified · MISLE 47638 · 26 January 2004 · activity 1997664DENISE C. DUTRA Freight Barge · MISLE 53132 · 25 August 1996 · activity 54449SARAH REED Towing Vessel · MISLE 202372 · 25 August 1996 · activity 54449TERILYN Towing Vessel · MISLE 107535 · 6 October 1992 · activity 174252TERILYN Towing Vessel · MISLE 107535 · 29 January 1992 · activity 149542

Inspection history · 62

19 September 2025 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8244558
1 October 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8008912
14 August 2024 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7980865
6 July 2023 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7741065
12 December 2022 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7613344
25 August 2022 Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7543461
13 November 2020 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7092988
9 October 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6831226
29 November 2018 COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6589187
12 December 2017 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6322761
30 May 2017 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6159818
3 March 2017 Administrative Inspection · Deficiency Check · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6098277
6 May 2016 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5870718
10 November 2015 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5760760
16 July 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4390310
14 December 2009 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3648865
13 June 2008 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3239014
21 February 2008 Deficiency Check · Internal Structural Exam · Drydock Extension · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3150412
26 January 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1997664
9 April 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1393643
11 April 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1373014
9 November 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 812289
30 August 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 939915
25 August 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 54449
10 July 1996 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1093043
28 March 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1079656
16 February 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 880656
15 August 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 443166
17 July 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 874983
3 February 1995 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1150052
18 August 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 865067
20 January 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1163997
4 October 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 846751
29 June 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1157576
19 March 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 834962
26 February 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 838242
20 November 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1138081
6 October 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 174252
10 April 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 953450
7 April 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 945430
3 March 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1134347
21 February 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1262831
29 January 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 149542
1 July 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1249406
12 December 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 929026
6 July 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 925487
23 February 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 929389
21 February 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1235273
9 February 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 907249
8 January 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 900729
15 December 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1032216
27 June 1988 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1207815
2 February 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1017161
23 December 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1008509
12 December 1986 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1025552
24 June 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1304935
18 December 1985 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1301337
31 October 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 994697
31 October 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1003194
5 October 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 995555
31 January 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1285179
14 December 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 976065

Deficiency record · 99

09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 1 October 2024 Resolved
The Inspection shall be such as to insure that the vessel, as regards to structure... and other equipment, is in satisfactory condition and fit for the service for which it is intended, and that it complies with the applicable regulations or such vessels... The catwalk for the crane has several areas that are wasted and broken welds. Barge rep was on scene and USCG MI pointed out the areas to be crop and renewed to original by October 31st, 2025, during Class survey. (705) 46 CFR 91.25-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2025
Resolved 19 September 2025
Resolution: Welds were repaired and verified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2024 Resolved
The installations of all systems of an electrical engineering or interior communication nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter J of this chapter. Battery in machinery space missing cover and battery on deck for hydraulic power unit not in a battery box. 46 CFR 96.05-1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2024
Resolved 14 October 2024
Resolution: O/O submitted photos batteries covered and in a battery box.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 14 July 2023 Resolved
The pressure portions of pressure vessels shall normally have a corrosion allowance of one-sixth of the calculated thickness, or one-sixteenth inch, whichever is smaller added to the calculated thickness as determined by the applicable design formula. The #1 Air Receiver had excessive corrosion on the top 1/3 portion of the interior of the pressure vessel. The operator was unable to provide the U1A to verify the corrosion allowance. Repair with a pre-approved repair proposal submitted to the marine inspector or replace with a Coast Guard approved air receiver that meets 46 CFR 54.01-5(c)(3). 46 CFR 54.01-35
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2023
Resolution: #1 Air receiver replaced with new unit. U1A provided and reveiwed, SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2023 Resolved
Each cable installation must meet sections 25 except 25.11 of IEEE 45-2002. The cables and wire in the overhead of the engine space were not properly supported by metal brackets and some lights were found to be wire tied to the brackets instead of properly supported. 46 CFR 111.60-5(a)(1)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2023
Resolution: Support brackets installed. SAT.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 14 July 2023 Resolved
The renewal survey shall be such as to ensure that the structure, equipment, systems, fittings, arrangements and material fully comply with applicable requirements of Chapter 3 of this Annex. The vessel does not currently have on board: Bunker Delivery Notes for the current fuel oil; Fuel oil samples properly labeled and secured for the fuel oil on board; EIAPP for each engine over 130 KW; Technical Files for each engine over 130 KW. Correct prior to making an international voyage. MARPOL 73/76 (2017) Annex VI Reg. 5.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2023
Resolution: Procedure for documenting and labelling fuel oil samples updated and reviewed. Vessel rep will follow established procedures and regs for all future handling of fuel oil. Vessel rep could not provide the EIAPP documents. IAPP not issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 July 2023 Resolved
Grab line. The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. Replace deteriorated lines on all lifebuoys.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2023
Resolved 14 July 2023
Resolution: New ring buoys were purchased and placed on board in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 July 2023 Resolved
Attachments and fittings. Lifejackets must have the following attachments and fittings: (i) Each lifejacket must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the lifejacket. Multiple lights inoperative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2023
Resolved 14 July 2023
Resolution: New lights were purchased and placed in service on the lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 July 2023 Resolved
vent outlets from all tanks which may emit flammable or combustible vapors, such as bilge slop tanks and contaminated drain tanks, must be fitted with a single screen of corrosion-resistant wire of at least 30 by 30 mesh, or two screens of at least 20 by 20 mesh spaced not less than one-half inch (13mm) nor more than 11/2 inches (38mm) apart. The clear area through the mesh must not be less than the internal unobstructed area of the required pipe. No flame screen on generator day tank.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2023
Resolved 14 July 2023
Resolution: Flame screens were replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 July 2023 Resolved
Remaining worklist items issued via email to vessel rep and uploaded into documents section.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2023
Resolved 27 July 2023
Resolution: Worklist items complete.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 November 2020 Resolved
If sediment was discharged within the jurisdiction of the United States, include the name and location of the facility where sediment disposal took place. The master, owner, operator, agent or person in charge of a vessel subject to this section must retain a signed copy of this information on-board the vessel for 2 years. Vessel representative was unable to provide USCG Inspectors with ballast water records as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 19 September 2025
Resolution: Vessel's ballast records in order.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 November 2020 Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern of the vessel under 67.123 of part 67 of this chapter. Vessel's lifebuoys required markings are severely faded/have been worn off. Rectify prior to vessel certification.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 19 September 2025
Resolution: Markings on Lifebuoy sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2020 Resolved
Lifejackets must be stowed as follows: Lifejackets must be readily accessible. Lifejackets were not stowed in designated stowage location. Rectify prior to vessel certification.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 19 September 2025
Resolution: Lifejackets has a designated area.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 November 2020 Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens and meet the requirements of § 84.15. Navigation light screens were not painted matt black. Rectify prior to vessel certification.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 19 September 2025
Resolution: Navigation lights have black back panels.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2018 Resolved
Lifejackets must be readily accessible when stowed.
Action required: 66 - Prior to drilling or production operations
Due 28 December 2018
Resolved 10 December 2018
Resolution: O/O mitigate deficiency to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2018 Resolved
Each lifejacket must have a lifejacket light approved and attached to the lifejacket. The light was expired.
Action required: 66 - Prior to drilling or production operations
Due 28 December 2018
Resolved 10 December 2018
Resolution: O/O mitigated deficiency to the satisfaction of the attending Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 November 2018 Resolved
A current Federal Communications Commission (FCC) station license must be posted at the principal control point of each station. The FCC license was expired.
Action required: 66 - Prior to drilling or production operations
Due 28 December 2018
Resolved 10 December 2018
Resolution: O/O mitigated deficiency to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 November 2018 Resolved
Barge did not maintain a current and accurate transfer procedure for governing the tranfer of the fuel oil for the deck and miscellaneous engineering/deck equipment.
Action required: 705 - Other - as specified
Due 28 December 2018
Resolved 10 December 2018
Resolution: O/O mitigated deficiency to the satisfaction of the attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 29 November 2018 Resolved
A valid Non-Tank Response Plan (NT-VRP) is required to be on board. The NT-VRP was not on board.
Action required: 66 - Prior to drilling or production operations
Resolved 30 November 2018
01 - Certificates & Documentation › 013 - Documents › Certificate or documentary evidence of financial security relating to shipowners liability
Issued 29 November 2018 Resolved
A vessel that is 300 gross tons must be able to present a valid Certificat of Financial Responsibility (COFR). COFR was not made available to inspector. Reviewed ECOFR.com and verified COFR is in good standing.
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 29 November 2018 Resolved
All vessels engaged in domestic voyages by sea shall be subject to the applicable Load Line requirements. The vessels Load Line certificate was expired. Operations are limited to inside the boundary line.
Action required: 10 - Deficiency Rectified
Resolved 30 November 2018
14 - Pollution Prevention › 147 - Anti-Fouling › AFS supporting documentation
Issued 29 November 2018 Resolved
Ships of 400 gros tons or more shall comply with Anti-Fouling systems convention. The AFS certificate was expired. Operations are limited to inside the boundary line.
Action required: 705 - Other - as specified
Resolved 4 December 2018
Documentation › Certificates/Documents › Stability Letter
Issued 12 December 2017 Resolved
A stablity booklet must be prepared for each vessel. No proof of a valid stabilty booklet was onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current certificate/document while onboard.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 12 December 2017 Resolved
A valid SOPEP is required to be onboard. Vessel did not provide a valid SOPEP or Non Tank Vessel Response Plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current cerificate/document while onboard.
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 12 December 2017 Resolved
Each operator or agent of a vessel with a capacity of 250 or more barrels shall designate, either by name or by position in the crew, the person in charge (PIC) of each transfer to or from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current cerificate/document while onboard.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 12 December 2017 Resolved
The vessel operator required to have transfer procedures shall require vessel personnel to use the transfer procedures for each transfer operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current cerificate/document while onboard.
Electrical › Electric Generation Source (service) › Generator
Issued 12 December 2017 Resolved
Make machinery space available and machinery operational to attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Space was made available and all machinery that was necessary was tested.
Personnel › Training › Lifeboatman
Issued 12 December 2017 Resolved
The barge's COI requires 01 certified Lifeboatman to be onboard when industrial personnel are onboard working. No proof of Lifeboatman training onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current certificate/document while onboard.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 December 2017 Resolved
Provide proof of enrollment in Drug and Alcohol Testing Program, and proof that Industrial Personnel onboard vessel are enrolled in Drug and Alcohol Testing Program.
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current certificate/document while onboard.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 12 December 2017 Resolved
Maintain a ballast water management (BWM) plan that has been developed specifically for the vessel.
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Inspector saw current certificate/document while onboard.
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 12 December 2017 Resolved
Lifejackets must be readily accessible when stowed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Life jackets were placed in an accessible area.
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 December 2017 Resolved
Every crewmember must participate in at least one abandon ship drill and one fire drill every month. There was no record of drills onboard.
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Vessel began documentig items in Log Book.
Documentation › Logs/Records › Logbook (official)
Issued 12 December 2017 Resolved
Vessel needs to maintain a logbook and records onboard for drills conducted and daily activity onboard vessel.
Action required: 705 - Other - as specified
Resolved 11 January 2018
Resolution: Vessel is maintaining log book.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 8 March 2017 Resolved
Fuel oil transfer hoses shall be locked-out/tagged-out until hydrostatically tested IAW 46 CFR 156.170.
Action required: 705 - Other - as specified
Resolved 5 April 2018
Resolution: Attending marine inspectors cleared deficiencies during exam, when reviewing case work def was never cleared. Dating resolve date as date which case was reviewed, after discussing def with attending marine inspectors. Hose is no longer onboard.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 6 March 2017 Resolved
Properly dispose of all oil-soaked rags/absorbent pads. ID and repair sourses of oil leaks on all machinery.
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 10 April 2017
Resolution: Unauthorized equipment removed.
Engineering › Pressure Vessel › Pressure Gauge
Issued 6 March 2017 Resolved
Demonstrate proper operation of the pressure switch on the fwd-most air receiver in the machinery space.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Witnessed satisfactory test.
Documentation › Logs/Records › Declaration of Inspection
Issued 6 March 2017 Resolved
Provide a copy of the signed DOI for the last fuel oil transfer and a copy of the BDN.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Reviewed records and provided additional training to crew.
Electrical › Electric Generation Source (service) › Generator
Issued 6 March 2017 Resolved
Demonstrate proper operation of overspeed and loss of LOP shutdowns on each generator prime mover.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 24 April 2017
Resolution: Witnessed overspeed tests, reviewed technician service reports.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 March 2017 Resolved
Mount each fire extinguisher in a suitable approved bracket which provides quick and positive release of the extinguisher for immediate use.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified placement and brackets.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 March 2017 Resolved
Exhaust sys piping, including exhaust manifold, shall be provided with protective guards, jacketing, or covers wherever temp exceeds 200*F.
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 4 May 2017
Resolution: Verified all manifold exhaust jacketing in place.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 6 March 2017 Resolved
No flammable or combustible liquids may be stowed in any accommodation, control or services space (other than a paint locker). Move fuel samples to appropriate location.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified storage location of fuel samples.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 March 2017 Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified markings.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 March 2017 Resolved
Each self igniting light used with a lifebuoy needs to be attached to the body of the lifebuoy.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified placement.
Lifesaving › Lifebuoys › Serviceable
Issued 6 March 2017 Resolved
Replace all worn/broken grab lines.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified condition.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 6 March 2017 Resolved
Each lifejacket shall have a light and whistle firmly attached to the lifejacket.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified attachments.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 6 March 2017 Resolved
The liferaft must have a painter system providing a connection between the vessel and the liferaft and be arranged in a float-free arrangement.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified installation.
Documentation › Logs/Records › Drug Test Records
Issued 6 March 2017 Resolved
Provide proof of a vailid company enrollment in a drug and alcohol program.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 10 April 2017
Resolution: Verified documentation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 March 2017 Resolved
Failure to complete the requierd annual or periodic inspection.
Action required: 705 - Other - as specified
Resolved 6 March 2017
Resolution: Sector NY attended for periodic inspection.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 10 November 2015 Resolved
The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks that operates in the waters of the United States must Maintain a ballast water management (BWM) plan that has been developed specifically for the vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 15 January 2016
Resolution: Vessel has created and implemented Ballast Water Management Plam.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 November 2015 Resolved
All vessels shall have efficient guard rails or bulwarks on deck. The height of the rail or bulwark shall b at least 39.5 inches from the deck. At exposed peripheries of the freeboard deck the rails should be at least three courses, including the top.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 23 June 2016
Resolution: CVC-1 has allowed barge to be exempt from hand rail requirements while operating exclusively at the Tappan Zee Bridge Work site.
Lifesaving › Inflatable Liferafts › Float Free
Issued 10 November 2015 Resolved
Each liferaft must be arranged for float-free launching. The liferaft is not hooked up with a float free arrangement and is also located under the crane overhang, potentially preventing the liferaft floating free during an emergency. Provide a float free arrangement for the liferaft.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 8 December 2015
Resolution: Liferaft has been relocated and properly hooked up in a float-free arrangement.
Personnel › Certificates/Documents/Licenses › MMD, Lifeboatman
Issued 10 November 2015 Resolved
The COI issued by an Officer in Charge, Marine Inspection (OCMI) to a vessel required to be inspected specifies the minimum complement of officers and crew necessary for the safe operation of the vessel. The barge's COI requires (01) certified lifeboatsman to be onboard when industrial personnel are onboard working. No lifeboatsman was onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 15 January 2016
Resolution: Crew members have received liferaft training. Training is good for 2 years.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 10 November 2015 Resolved
All portable fire extinguishers shall be mounted on an approved mounting bracket. Multiple fire extinguishers were missing brackets or mounted on the wrong type.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 8 December 2015
Resolution: All fire extinguishers have been mounted in approved mounts.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 February 2008 Resolved
Conduct internal sturctural exam due 16DEC2007.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Resolution: ISE complete.
Construction/Loadline › Hull › Hull Plating
Issued 21 February 2008 Resolved
Conduct drydock exam or get USCG HQ extension to align with ABS surveys. Drydock due 16DEC2007.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2008
Resolution: Vessel given verbal approval to depart 21MAR08; CG-5341 approval signed 24MAR08.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 21 February 2008 Resolved
Provide original Certificate of Documentation.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Resolution: SAT. Second time issued in 2 inspections.
Construction/Loadline › Markings › Load Line Mark
Issued 21 February 2008 Resolved
Paint deck reference lines P/S above plimsol
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Resolution: SAT
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 21 February 2008 Resolved
Provide current SOPEP approval letter dated 13SEP07; letter on board expired in Dec07.
Due 21 March 2008
Resolved 4 March 2008
Resolution: SAT.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 21 February 2008 Resolved
SOPEP-OOPS Plan 2005 Sector San Diego phone numbers are incorrect
Due 21 March 2008
Resolved 4 March 2008
Resolution: Corrected
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 21 February 2008 Resolved
Provide current SOPEP IMO Annex 2 annual update
Due 21 March 2008
Resolved 4 March 2008
Resolution: SAT
Fire Fighting › Ventilation Systems › Ducts
Issued 21 February 2008 Resolved
Repair air louvers P/S Engineroom to properly operate.
Due 21 March 2008
Resolved 4 March 2008
Resolution: Test SAT.
Construction/Loadline
Issued 16 February 1996 Resolved
Prior to operations, demonstrate proper operation of a portable pump with sufficient hose length to remove water from all compartments.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Accommodation/Occupational Safety
Issued 16 February 1996 Resolved
Place flammable spray cans in flammable locker.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Unknown
Issued 16 February 1996 Resolved
Provide documentation that the fuel hose has been pressure tested.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Lifesaving
Issued 16 February 1996 Resolved
Prior to operations above 35 degrees north latitude, provide 5 Coast Guard approved exposure suits.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Lifesaving
Issued 16 February 1996 Resolved
Properly mount liferaft.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Engineering
Issued 16 February 1996 Resolved
Demonstrate proper operation of generator's overspeed trips and loss of lube oil trip.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Electrical
Issued 20 January 1994 Resolved
REPAIR/REPLACE PANEL DOORS FOR TWO PANELBOARDS, ONE IN MACHINERY SPACE AND ONE BEHIND REFRIGERATOR.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Electrical
Issued 20 January 1994 Resolved
PROVE GENERATOR OVERSPEED.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Electrical
Issued 20 January 1994 Resolved
PROPERLY WIRE DECK LIGHT ONE LEVEL ABOVE MAIN DECK PORTSIDE.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Electrical
Issued 20 January 1994 Resolved
PROVE OPERATION OF ALL DECK LIGHTING. (2) ON CRANE OOC.
Condition: Unknown
Due 30 June 1994
Resolved 15 February 1994
Lifesaving
Issued 20 January 1994 Resolved
CLEAN OIL OFF DECK PORT SIDE AFT.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Accommodation/Occupational Safety
Issued 20 January 1994 Resolved
PROVIDE LOCKING DEVICE/WARNING SIGN FOR MSD OVBD VALVE.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Electrical
Issued 20 January 1994 Resolved
PROVE PROPER OPERATION OF GENERATOR LOW L/O ALARM, AUDIBLE AND VISUAL.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Engineering
Issued 20 January 1994 Resolved
PROVE OVERSPEED ON FORWARD AUXILIARY DIESEL.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Lifesaving
Issued 20 January 1994 Resolved
PROVIDE ONE WATER LIGHT FOR RING BUOY.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Lifesaving
Issued 20 January 1994 Resolved
PROVIDE RETRO REFLECTIVE TAPE ON ALL RING BUOYS.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Engineering
Issued 20 January 1994 Resolved
PROVE PROPER OPERATION OF HOIST MAIN DIESEL LOW L/O ALARMS.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Documentation
Issued 20 January 1994 Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Lifesaving
Issued 20 November 1992 Resolved
PRIOR TO THE CARRIAGE OF INDUSTRIAL PERSONNEL, PROVIDE ONE TYPE I PFD FOR EACH PERSON CARRIED.
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Engineering
Issued 20 November 1992 Resolved
PROVIDE A LIST OF NAMES, THAT WILL ACT AS PERSONS IN CHARGE DURING OIL TRANSFERS. THIS ITEM IS TO BE ACCOMPLISHED PRIOR TO TRANSFERING OF OIL OR 20 JANUARY 1993, WHICHEVER OCCURS FIRST.
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Lifesaving
Issued 20 November 1992 Resolved
PRIOR TO THE CARRIAGE OF INDUSTRIAL PERSONNEL, PROVIDE ONE APPROPRIATELY SIZED PRIMARY LIFESAVING EQUIPMENT FOR PERSONS CARRIED.
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Electrical
Issued 20 November 1992 Resolved
PLACE ELECTRICAL MAT IN FRONT OF SWITCH BOARD.
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Electrical
Issued 20 November 1992 Resolved
REPLACE MISSING OVERHEAD LIGHT DIFFUSER COVERS.
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Construction/Loadline
Issued 21 February 1992 Resolved
CHANGE THE HOME PORT PAINTED ON THE STERN FROM "ALAMEDA" TO "SAN FRANCISCO,CA."
Condition: Unknown
Due 16 March 1992
Resolved 16 March 1992
Documentation
Issued 21 February 1992 Resolved
PROVIDE EVIDENCE OF CURRENT FMC CERTIFICATE.
Condition: Unknown
Due 16 March 1992
Resolved 16 March 1992
Electrical
Issued 21 February 1992 Resolved
INSTALL BLANK OR CIRCUIT BREAKER IN "TUB" POWER PANEL POSITION #11.
Condition: Unknown
Due 16 March 1992
Resolved 16 March 1992
Navigation
Issued 21 February 1992 Resolved
REINSTALL NAVIGATION LIGHT BRACKETS.
Condition: Unknown
Due 21 February 1992
Resolved 21 February 1992
Engineering
Issued 21 February 1992 Resolved
REMOVE TRASH FROM PORT AND STARBOARD FUEL TANK VENT CONTAINMENTS.
Condition: Unknown
Due 16 March 1992
Resolved 16 March 1992
Construction/Loadline
Issued 21 February 1992 Resolved
CROP AND RENEW BENT VERTICAL STIFFENER IN FORWARD PORT-CENTER RAKE. (SECONDSTIFFENER INBOARD FROM OUTBOARD BULKHEAD, BOW AREA.)
Condition: Unknown
Due 16 March 1992
Resolved 16 March 1992
Engineering
Issued 21 February 1992 Resolved
MAKE AVAILABLE OIL TRANSFER PROCEDURES PRIOR TO NEXT OIL TRANSFER AND NO LATER THAN 21 MARCH 1992.
Condition: Unknown
Due 16 March 1992
Resolved 16 March 1992
Construction/Loadline
Issued 8 January 1990 Resolved
PROPERLY INSTALL SOUNDING TUBES/DEVICES FOR FORWARD BALLAST TANKS
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Electrical
Issued 8 January 1990 Resolved
LABLE CIRCUTS IN ELECTRICAL CIRCUT BREAKER BOX.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Deck/Cargo
Issued 8 January 1990 Resolved
REPAIR/REPLACE (MAKE READABLE) IDENTIFICATION TAG ON EXPOSED AIR TANK
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Electrical
Issued 23 December 1987 Resolved
PROVIDE SUITABLE BOX FOR EMERGENCY DIESEL GENERATOR BATTERY BOX. BOTTOM AND LOWER 3 INCH OF SIDES MUST BE LINED WITH A MATERIAL CORROSION RESISTANT TO THE ELECTROLYTE.
Condition: Unknown
Due 23 December 1987
Resolved 23 December 1987
Electrical
Issued 23 December 1987 Resolved
PROVIDE 3 NEW BATTERY CAPS TO REPLACE BROKEN ONES.
Condition: Unknown
Due 23 December 1987
Resolved 23 December 1987
Engineering
Issued 18 December 1985 Resolved
REMOVE DEBRIS FROM FUEL OIL CONTAINMENTS AND PROVIDE SUITABLE PLUGS.
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985
Electrical
Issued 18 December 1985 Resolved
REPAIR OR REMOVE DISCONNECTED WIRE AND WORN WIRE AT ELECTRIC PANEL BOARD IN CRANE TUB.
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985
Lifesaving
Issued 31 October 1985 Resolved
PROVIDE COAST GUARD APPROVED TYPE 1 LIFEJACKETS FOR ALL PERSONS ONBOARD TRIP FROM OAKLAND TO SAN JOSE ON OR ABOUT 2000, 07 NOVEMBER 1985.
Condition: Unknown
Due 31 October 1985
Resolved 31 October 1985
Lifesaving
Issued 31 October 1985 Resolved
REQUIRED TO CARRY 14 ADULT PFD'S TO BE ONBOARD FOR SINGLE VOYAGE FROM OAKLAND,CA TO SAN JOSE, CA ON OR ABOUT 2000, 7 NOV 85.
Condition: Unknown
Due 31 October 1985
Resolved 31 October 1985

Casualty record · 1

13 April 2013Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4568401
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

BARGE 5 (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.