Records from 1985 to 2010. Most recent: inspection, 21 January 2010.
Inspection history · 65
21 January 2010
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3667583
27 August 2009
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3577885
27 August 2009
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3577886
26 March 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3432154
9 March 2009
Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3427526
28 March 2008
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3172956
12 March 2007
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2886382
14 March 2006
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2601767
22 March 2005
Internal Structural Exam · COI Inspection · MTSA Verification · Cargo Tank Internal
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2316403
17 October 2004
Damage Survey
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2222446
13 October 2004
Damage Survey · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2220365
9 September 2004
Permit to Proceed
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2191234
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1974694
3 November 2003
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1943021
4 October 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1684257
9 January 2002
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1476954
21 November 2000
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1469988
20 May 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 56578
7 January 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463539
29 June 1999
Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1081157
25 February 1999
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1393095
11 December 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 528856
24 November 1998
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 806318
24 April 1998
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 466282
4 March 1998
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 653155
23 February 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1424531
7 February 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 653154
10 December 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448983
15 November 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 531991
15 November 1997
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 787099
31 October 1997
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 213620
20 February 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363974
9 April 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438424
15 March 1995
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428433
29 December 1993
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 850701
22 September 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1151116
22 February 1993
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 837016
13 January 1993
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1137627
22 September 1992
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 501362
13 July 1992
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 949874
10 July 1992
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1262663
16 January 1992
Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 947636
19 November 1991
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 446480
21 May 1991
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 522644
29 November 1990
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 901234
11 September 1990
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 526757
25 April 1990
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 528587
28 October 1989
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1032066
8 December 1988
Hull Examination · COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1033841
15 July 1988
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1343479
23 February 1988
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 512560
9 October 1987
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1326102
13 May 1987
MARPOL Annex II Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1022253
7 May 1987
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 469130
5 May 1987
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1322534
28 March 1987
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 515572
10 October 1986
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1007879
25 September 1986
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 535853
18 September 1986
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1006593
8 September 1986
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1329813
26 January 1986
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 452525
21 October 1985
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 496448
15 October 1985
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1300607
10 October 1985
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 518169
23 January 1985
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 976307
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 28 March 2008
Resolved
Vessel's emergncy shutdown does not operate properly. Vessel is required to repair the shutdown prior to conducting cargo operations.
Action required: 705 - Other - as specified
Resolved 9 March 2009
Resolution: Witnessed satisfactory test of ESD.
Construction/Loadline › Hull › Bottom Plating
Issued 17 October 2004
Resolved
Make satisfactory repairs to approximately 4 inch hull fracture in bottom plate in the bilge knuckle, port side in way of turn and connection between slope sheet transition to straight bottom knuckle.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 October 2004
Resolved 17 October 2004
Resolution: damaged plate heated and faired, and the fracture gouged and welded.
Construction/Loadline › Hull › Longitudinal Frame
Issued 17 October 2004
Resolved
Make satisfactory repairs to the fractured weld in way of the 1st bottom longitudinal connecting to the aft side of 1st chord frame in the #1 port wing tank.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 October 2004
Resolved 17 October 2004
Resolution: Fractured weld cleaned and rewelded.
Construction/Loadline › Hull › Longitudinal Frame
Issued 17 October 2004
Resolved
Make satisfactory repairs to the fractured weld in the 2nd sideshell longitudinal from the bottom connecting to the afterside of the 1st chord frame in the #1 Port wing void.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 October 2004
Resolved 17 October 2004
Resolution: fractured weld was cleaned and rewelded.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 9 September 2004
Resolved
The #1 cargo tank has a small fracture/pinhole, approximately 3.5' below the deck, leaking Ethylene Glycol into the #1 port wing void. A temporary repair, a strongback is successfully stopping further leakage. Issued PTP to offload current cargo and proceed to shipyard to make permanent repairs.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 October 2004
Resolution: Cleared PTP.
Documentation
Issued 25 February 1999
Resolved
VESSEL IS PROHIBITED FROM CARRIAGE OF ANY OIL PRODUCT UNTIL VESSEL RESPONSEPLAN IS DEVELOPED, APPROVED AND ON BOARD.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Documentation
Issued 10 December 1997
Resolved
On 06NOV97 the vessel took on a load of ethanol. This product was not authorized on the COI.
Condition: Unknown
Due 10 December 1997
Resolved 7 February 1998
Unknown
Issued 15 November 1997
Resolved
DISCHARGE CARGO FROM TANK BARGE PRIOR TO DEPARTING PEORIA, IL.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Deck/Cargo
Issued 15 November 1997
Resolved
PRIOR TO LOADING BARGE, GAS FREE AND REPAIR FRACTURED CARGO TANK BOTTOM.
Condition: Unknown
Due 15 November 1997
Resolved 15 November 1997
Deck/Cargo
Issued 16 January 1992
Resolved
THE VAPOR RECOVERY SYSTEM SHALL NOT BE USED FOR THE COLLECTION OF CARGO VAPORS UNTIL PLANS HAVE BEEN APPROVED BY THE MARINE SAFETY CENTER AND THE CERTIFICATE OF INSPECTION IS ENDORSED AUTHORIZING USE OF SAME.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992