Records from 1998 to 2015. Most recent: inspection, 12 November 2015.
Documentation record
Registered dimensions (L × B × D)130.4 ft × 26.0 ft × 11.1 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)130.4 ft × 26.0 ft × 11.1 ft
ITC tonnagegross 243 / net 72
BuilderSWIFTSHIPS INC · MORGAN CITY, LA, UNITED STATES · built 1998
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
72 - Convention (Subpart B), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
243 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 25
12 November 2015
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5762499
1 December 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4199999
29 September 2011
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4156924
24 September 2010
Re-Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3858102
1 October 2008
Internal Structural Exam · Administrative Inspection · Drydock Exam · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3336196
16 July 2008
Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3269668
14 July 2008
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3267954
28 September 2007
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3071179
29 September 2006
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2789719
26 July 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2750774
7 October 2005
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2510117
1 October 2004
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2054503
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977693
13 November 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1950728
30 September 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1923892
14 July 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1845982
30 September 2002
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1660526
1 October 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470050
27 September 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449380
30 September 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434934
7 June 1999
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805179
7 June 1999
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 810577
16 May 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 109772
30 September 1998
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468474
19 August 1998
Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 795780
Construction/Loadline › Hull › Hull Plating
Issued 14 July 2008
Resolved
Proceed to shipyard to make perminant repairs to hull IWO Generator space from collision damage.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 16 July 2008
Communications › Audible Communications › Horn/Whistle
Issued 29 September 2006
Resolved
Ships whistle switch was stuck.
Due 29 September 2006
Resolved 29 September 2006
Resolution: Switch was lubricated ensuring free movement.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 29 September 2006
Resolved
CO2 horn inoperable during CO2 system test.
Due 29 September 2006
Resolved 29 September 2006
Resolution: CO2 Horn repaired.