Records from 1985 to 2026. Most recent: inspection, 14 July 2026.
Inspection history · 88
14 July 2026
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8432834
26 February 2026
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8316431
5 June 2025
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8152878
7 January 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8049306
10 May 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7912883
8 February 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7854034
7 July 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7736152
20 March 2023
Construction Oversight · Inclining Experiment · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7653416
9 January 2023
Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7613276
17 March 2022
Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7413512
23 February 2022
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7400805
29 April 2021
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7178353
17 February 2021
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7141992
2 October 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7069883
9 June 2020
Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6971848
4 April 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6937338
24 October 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6840991
25 September 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6820502
6 September 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6805424
25 March 2019
Drydock Exam · Internal Structural Exam · In-Service Inspection
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6648698
14 March 2019
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6641108
17 October 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6563021
12 September 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6538755
23 August 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6520436
10 January 2018
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6334600
5 October 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6281750
10 August 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6236259
22 March 2017
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6109383
16 February 2017
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6090249
12 October 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6020807
19 August 2016
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5976954
11 July 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5936984
28 May 2016
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5893954
13 April 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5852467
15 October 2015
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5829535
30 September 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5732294
7 September 2015
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5829067
8 October 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5001357
4 June 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4879309
23 March 2010
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3702414
9 December 2009
Examination of Repairs · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3628103
9 December 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3647500
8 April 2009
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3448682
3 January 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3387918
15 August 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3302356
22 January 2008
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3134246
1 October 2007
Hull Examination · Examination of Repairs · Inclining Experiment · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3070190
11 August 2006
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2744193
18 August 2005
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2467208
21 June 2005
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2397039
3 March 2004
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2017049
2 March 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2039425
23 December 2003
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1992836
13 November 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1950728
13 November 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1950747
9 September 2003
Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1901155
10 February 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1742181
28 April 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1627966
17 January 2002
Re-Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1479175
7 February 2001
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 1521837
7 December 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442915
6 December 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214492
7 December 1998
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468032
21 January 1998
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1364536
23 November 1996
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1371583
10 November 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 11487
10 November 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 215489
10 November 1996
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1465887
10 January 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455320
28 February 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 9503
10 January 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434199
23 November 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 43543
4 January 1994
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1370769
7 January 1993
COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1132553
7 January 1993
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1162320
7 January 1993
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1162329
28 January 1992
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1008434
10 May 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224698
27 November 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899975
29 May 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1237312
17 May 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 924127
17 June 1989
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1339348
18 May 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1203148
17 June 1988
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1204338
19 August 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310547
12 March 1987
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327551
10 September 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1000258
21 October 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293328
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 14 July 2026
Resolved
Prove proper operation of bilge high water alarms in the machine space and passenger space.
Action required: 10 - Deficiency Rectified
Resolved 14 July 2026
Resolution: New float switched installed and tested sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2026
No resolution recorded
Diesel fuel (2oz) was found in the space forward of the fuel tank space and aft of the potable water tank. During the previous hull/ise exams fuel was also identified in the same location. The nearest fuel tanks were drained, cleaned and pressure tested with no defects found. At this time it is unknown where the fuel originated; adjacent fuel tanks are still empty. Vessel master is required to make daily checks of the space and log the checks and any presence of fuel for attending marine inspector to review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel had multiple extension cords plugged in berthing areas.
Action required: 10 - Deficiency Rectified
Resolved 7 January 2025
Resolution: Extension cords removed, crew instructed on dangers of unaithorized electrical installations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 February 2024
Resolved
Each fixed power bilge pump must be self priming. Vessel unable to remove nuisance water from lazerette bilge. Test all bilge suctions to satisfaction of CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 February 2024
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 8 February 2024
Resolved
Each buoyant work vest carried aboard must be approved under subpart 160.053 of this chapter or, as a commercial hybrid personal flotation device, under subpart 160.077 of this chapter. Vessel only has 02 approved work vests for 04 crew members.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 8 February 2024
Resolved
Vessel required FCC Radiosafety Telephony and FCC Bridge-to-Bridge certificates. No certificates were available upon request to CG marine inspector. Obtain certificates and present to CG.
47 CFR 80
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 February 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 February 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel had no evidence of being enrolled in a maritime drug testing consortium. Provide to CG marine inspector.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 February 2024
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 7 July 2023
Resolved
In accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter. Prior to operating in commercial service, no carriage of cargo, no passengers and no offshore workers, provide a valid stability letter to the satisfaction of the cognizant OCMI. Vessel may be operated IAW its current COI for crew training and vessel operational testing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2023
Resolved 1 August 2023
Resolution: Received Stability letter from USCG MSC
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 7 July 2023
Resolved
Equipment for impulse-projected rocket type line-throwing appliance. Four service lines, each 4 mm (5/32 in.) minimum diameter with a minimum breaking strength of at least 2,250 N (500 lb.) Vessel currently has one service line onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2023
Resolved 6 October 2023
Resolution: Vessel ordered & received additional line throwing devices
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 9 January 2023
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears and machinery. Shaft on port Generator was missing guard and exposed. 46. CFR 177.35-15 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 25 January 2023
Resolution: Verified adequate guards were installed on port generator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 January 2023
Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with
permanent type connectors. Spring clips or other temporary type clamps are not permitted. Batteries currently have wing nuts and need a permanent type nut.
46 CFR 183.05-20 (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 25 January 2023
Resolution: Battery terminals were corrected with nuts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 February 2021
Resolved
Each ring life buoy with a floating waterlight must
have a lanyard of at least 910 millimeters (3 feet)
in length, but not more than 1,830 millimeters (6
feet), securing the waterlight around the body of
the ring life buoy. The MI observed that the
waterlights were secured around the grablines for
the ring buoys.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 February 2021
Resolved 17 February 2021
Resolution: The lights were adjusted to be secured around the body of the buoy.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 February 2021
Resolved
Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas accessible to passengers. The MI observed that the emergency escape hatch in the exercise room was located too high to be accessible without a ladder and none was in the space.
46CFR177.15-1(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 February 2021
Resolved 17 February 2021
Resolution: Crew brought a stepladder into the space. Stepladder will remain in space for emergency purposes.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 2 October 2020
Resolved
A vessel with a coastwise route must have life floats with an aggregate capacity for 100% of persons on board. The vessel's 30-person IBA has been removed for annual servicing. The total number of persons allowed on board is limited to 25 until the IBA is re-installed to the satisfaction of an attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2020
Resolved 24 November 2020
Resolution: Received photos of satisfactory reinstallation and servicing certificate.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 4 April 2020
Resolved
Each overnight accommodation space on a vessel
with overnight accommodations for passengers must
be fitted with an independent modular smoke detection
and alarm unit in compliance with § 181.450. Vessel's
crew overnight accommodation spaces do not have
required UL217 smoke detectors installed. Install
required detectors in all overnight accom spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2020
Resolved 14 April 2020
Resolution: UL217 smoke detectors installed in all required spaces.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 March 2019
Resolved
C/R approximate section of WTB located at frame 13. Bulkhead was corroded and need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 April 2019
Resolution: Vessel completed C/R and water tested, all sat.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 5 October 2017
Resolved
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 November 2017
Resolved 26 October 2017
Resolution: IBA installed correctly.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 10 August 2017
Resolved
THE VESSEL'S 30-PERSON IBA HAS BEEN REMOVED FOR ANNUAL SERVICING. THE TOTAL NUMBER OF PERSONS ALLOWED ON BOARD IS LIMITED TO 24 UNTIL THE IBA HAS BEEN RE-INSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Due 10 September 2017
Resolved 16 August 2017
Resolution: Verified installation and servicing of IBA.
Lifesaving › Inflatable Liferafts › Servicing
Issued 12 October 2016
Resolved
THE VESSEL'S 25-PERSON INFLATABLE LIFE RAFT HAS BEEN REMOVED FOR SERVICING. TOTAL PERSONS ALLOWED ON BOARD IS LIMITED TO 30 UNTIL THE LIFE RAFT IS REINSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 November 2016
Resolved 26 October 2016
Resolution: Verified satisfactory re-installation of serviced life raft.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 11 July 2016
Resolved
The vessel's 30-person IBA has been removed to annual servicing. Total persons allowed on board is limited to 25 until IBA has been re-installed to the satisfaction of an attending marine inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2016
Resolved 17 August 2016
Resolution: IBA maintenance completed by LRSE and IBA reinstalled onboard vessel.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 13 April 2016
Resolved
Replace all expired life jacket lights to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 27 April 2016
Resolution: Recieved email and purchase statement from vessel rep. documenting the purchase and installation of new water lights.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 30 September 2015
Resolved
THE VESSEL'S 25-PERSON INFLATABLE LIFERAFT HAS BEEN REMOVED FOR ANNUAL SERVICING. PASSENGER CAPACITY IS LIMITED TO 27 UNTIL THE RAFT IS PROPERLY REINSTALLED. RE-INSTALLATION OF THE LIFERAFT MUST BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 October 2015
Resolved 14 October 2015
Resolution: Inspected life raft installation. SAT.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 8 October 2014
Resolved
THE VESSEL'S 25-PERSON LIFE RAFT HAS BEEN REMOVED FOR SERVICING. COMPLETE SERVICING AND REINSTALL RAFT TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR. TOTAL PERSONS ALLOWED ON BOARD: 30
Action required: 705 - Other - as specified
Due 22 October 2014
Resolved 29 October 2014
Resolution: Inspected Life Raft installation and servicing data. SAT.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 4 June 2014
Resolved
The vessel's 30-person life raft has been removed for annual servicing. Passenger capacity is limited to 22.
Action required: 705 - Other - as specified
Due 18 June 2014
Resolved 18 June 2014
Resolution: 30 person life raft has been reinstalled and the installation has been inspected by attending marine inspector. SAT.
Documentation › Certificates/Documents › FCC SSL
Issued 21 June 2005
Resolved
Vsl was unable to obtain new FCC station license b/c FCC reported having system delays. Vsl to obtain new license and call sign w/in 30 days.
Due 2 September 2005
Resolved 18 August 2005
Resolution: Observed new station license, effective 8/5/05.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 June 2005
Resolved
Vsl unable to obtain required safety radiotelephony cert and bridge-to-bridge cert until it receives valid station license and call sign.
Due 2 September 2005
Resolved 18 August 2005
Resolution: Observed required certs, issued to vsl 8/17/05.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 June 2005
Resolved
Vsl to obtain valid safety radiotelephone and bridge to bridge cert.
Due 2 September 2005
Resolved 18 August 2005
Resolution: Observed required certs, issued to vsl 8/17/05.
Fire Fighting › Fire Main
Issued 23 September 2003
Resolved
Make repairs to fire pump discharge pipe, fire station collar pipe, and fire pump control switch. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2003
Resolved 24 September 2003
Construction/Loadline › Structures › Door
Issued 23 September 2003
Resolved
Adjust Main Deck and Rudder Room watertight doors.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2003
Resolved 24 September 2003
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 September 2003
Resolved
Install emergency lighting fixture for Rudder Room emergency escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2003
Resolved 24 September 2003
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 September 2003
Resolved
Renew 60 lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2003
Resolved 23 September 2003
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 23 September 2003
Resolved
Make repairs to port generator exhaust flex-pipe.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 24 September 2003
Construction/Loadline › Hull › Weld
Issued 23 September 2003
Resolved
Make repairs to (2) pick-up welds on port foc'sle deck and (7) pick-up welds on aft main deck.
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 24 September 2003
Construction/Loadline › Hull › Stiffener
Issued 23 September 2003
Resolved
Renew 6" section of seventh gusset from forward IWO port foc'sle deck.
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 24 September 2003
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Trunking
Issued 23 September 2003
Resolved
Make repairs to stbd aft fuel vent and free-up stbd forward fuel vent.
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 24 September 2003
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 September 2003
Resolved
Renew retro-reflective tape on 01 deck lifebuoy.
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 24 September 2003
Lifesaving › Buoyant Apparatus
Issued 23 September 2003
Resolved
Re-splice all life float painter lines. LEGACY COMPONENT DESC: Painter
Action required: 705 - Other - as specified
Due 23 October 2003
Resolved 24 September 2003
Fire Fighting › Means of Escape › Stairways
Issued 23 September 2003
Resolved
Install an escape ladder from the lower passenger space to the upper passenger space.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2003
Resolved 24 September 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 17 January 2002
Resolved
Fabricate new ladder to accomodate safer evacuation from lower passenger compt. through emergency escape.
Action required: 705 - Other - as specified
Due 17 February 2002
Resolved 24 September 2003
Fire Fighting › Fire Hydrants
Issued 17 January 2002
Resolved
Remove Port fire station from cargo railing and establish a stand alone fire station. LEGACY COMPONENT DESC: Location/Position
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 February 2002
Resolved 24 September 2003
Electrical
Issued 23 November 1996
Resolved
RELOCATE GALLEY EMERGENCY SHUTDOWN TO A MORE ACCESSIBLE LOCATION.
Condition: Unknown
Due 30 December 1996
Resolved 25 November 1996
Construction/Loadline
Issued 10 November 1996
Resolved
PROCEED TO A SHIPYARD IN COTP HOUSTON-GALVESTON ZONE AND MAKE PERMANENT REPAIRS TO BOW SECTION, DAMAGE DURING COLLISION ON 10NOV96 AT 0515 CST IN GALVESTON LIGHTERING ZONE, PRIOR TO PUTTING VESSEL BACK INTO OPERATION.
Condition: Unknown
Due 10 December 1996
Resolved 26 November 1996
Construction/Loadline
Issued 10 November 1996
Resolved
DURING REPAIRWORK WHILE AT DRYDOCK, REPLACE STEEL UNIONN JOINT WITH A UNIONJOINT THAT IS NOT A DISSIMILAR METAL IN BILGE SUCTION LINE IN FOREPEAK COMPARTMENT.
Condition: Unknown
Due 10 December 1996
Resolved 26 November 1996
Construction/Loadline
Issued 10 November 1996
Resolved
DURING REPAIRWORK WHILE IN DRYDOCK, REPAIR PITTED AREA IWO LOWER COLLISION BULKHEAD AT THE KEEL IN THE AFTER SIDE OF THE BULKHEAD.
Condition: Unknown
Due 10 December 1996
Resolved 26 November 1996
Accommodation/Occupational Safety
Issued 17 May 1990
Resolved
REPAIR CLOSURES FOR MACHINERY SPACE VENTS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990