GATEWAY ENDEAVOR

GATEWAY ENDEAVOR is a 1985 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2016, most recently in July 2026, along with 21 deficiencies — 1 with no resolution recorded — and 7 casualty investigations between 2002 and 2016.

Records from 2002 to 2026. Most recent: inspection, 14 July 2026.

Built
1985
Last inspected
14 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 July 2026
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE2656
258403
Flag
UNITED STATES
Maury page id
psix-258403

Documentation record

Registered dimensions (L × B × D)115.0 ft × 25.0 ft × 1.4 ft
Registered tonnagegross 99 / net 84
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT, INC. · PATTERSON, LA, UNITED STATES · built 1985
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 November 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
84 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PAULA Passenger (Inspected) · MISLE 58839 · 28 May 2016 · activity 5893954MAJESTY Passenger (Inspected) · MISLE 231763 · 28 May 2016 · activity 5893954ASTERIA Passenger (Inspected) · MISLE 478192 · 28 May 2016 · activity 5893954SANCTUARY Passenger (Inspected) · MISLE 489830 · 28 May 2016 · activity 5893954

Inspection history · 34

14 July 2026 COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8432834
26 February 2026 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8316431
5 June 2025 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8152878
7 January 2025 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8049306
10 May 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7912883
8 February 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7854034
7 July 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7736152
20 March 2023 Construction Oversight · Inclining Experiment · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7653416
9 January 2023 Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7613276
17 March 2022 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7413512
23 February 2022 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7400805
29 April 2021 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7178353
17 February 2021 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7141992
2 October 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7069883
9 June 2020 Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6971848
4 April 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6937338
24 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6840991
25 September 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6820502
6 September 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6805424
25 March 2019 Drydock Exam · Internal Structural Exam · In-Service Inspection
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6648698
14 March 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6641108
17 October 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6563021
12 September 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6538755
23 August 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6520436
10 January 2018 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6334600
5 October 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6281750
10 August 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6236259
22 March 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6109383
16 February 2017 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6090249
12 October 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6020807
19 August 2016 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5976954
11 July 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5936984
28 May 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5893954
13 April 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5852467

Deficiency record · 21

08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 14 July 2026 Resolved
Prove proper operation of bilge high water alarms in the machine space and passenger space.
Action required: 10 - Deficiency Rectified
Resolved 14 July 2026
Resolution: New float switched installed and tested sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2026 No resolution recorded
Diesel fuel (2oz) was found in the space forward of the fuel tank space and aft of the potable water tank. During the previous hull/ise exams fuel was also identified in the same location. The nearest fuel tanks were drained, cleaned and pressure tested with no defects found. At this time it is unknown where the fuel originated; adjacent fuel tanks are still empty. Vessel master is required to make daily checks of the space and log the checks and any presence of fuel for attending marine inspector to review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel had multiple extension cords plugged in berthing areas.
Action required: 10 - Deficiency Rectified
Resolved 7 January 2025
Resolution: Extension cords removed, crew instructed on dangers of unaithorized electrical installations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 February 2024 Resolved
Each fixed power bilge pump must be self priming. Vessel unable to remove nuisance water from lazerette bilge. Test all bilge suctions to satisfaction of CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 February 2024
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 8 February 2024 Resolved
Each buoyant work vest carried aboard must be approved under subpart 160.053 of this chapter or, as a commercial hybrid personal flotation device, under subpart 160.077 of this chapter. Vessel only has 02 approved work vests for 04 crew members.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 8 February 2024 Resolved
Vessel required FCC Radiosafety Telephony and FCC Bridge-to-Bridge certificates. No certificates were available upon request to CG marine inspector. Obtain certificates and present to CG. 47 CFR 80
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 February 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 February 2024 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel had no evidence of being enrolled in a maritime drug testing consortium. Provide to CG marine inspector.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 February 2024
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 7 July 2023 Resolved
In accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter. Prior to operating in commercial service, no carriage of cargo, no passengers and no offshore workers, provide a valid stability letter to the satisfaction of the cognizant OCMI. Vessel may be operated IAW its current COI for crew training and vessel operational testing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2023
Resolved 1 August 2023
Resolution: Received Stability letter from USCG MSC
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 7 July 2023 Resolved
Equipment for impulse-projected rocket type line-throwing appliance. Four service lines, each 4 mm (5/32 in.) minimum diameter with a minimum breaking strength of at least 2,250 N (500 lb.) Vessel currently has one service line onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2023
Resolved 6 October 2023
Resolution: Vessel ordered & received additional line throwing devices
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 9 January 2023 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears and machinery. Shaft on port Generator was missing guard and exposed. 46. CFR 177.35-15 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 25 January 2023
Resolution: Verified adequate guards were installed on port generator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 January 2023 Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Spring clips or other temporary type clamps are not permitted. Batteries currently have wing nuts and need a permanent type nut. 46 CFR 183.05-20 (c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 25 January 2023
Resolution: Battery terminals were corrected with nuts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 February 2021 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. The MI observed that the waterlights were secured around the grablines for the ring buoys.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 February 2021
Resolved 17 February 2021
Resolution: The lights were adjusted to be secured around the body of the buoy.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 February 2021 Resolved
Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas accessible to passengers. The MI observed that the emergency escape hatch in the exercise room was located too high to be accessible without a ladder and none was in the space. 46CFR177.15-1(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 February 2021
Resolved 17 February 2021
Resolution: Crew brought a stepladder into the space. Stepladder will remain in space for emergency purposes.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 2 October 2020 Resolved
A vessel with a coastwise route must have life floats with an aggregate capacity for 100% of persons on board. The vessel's 30-person IBA has been removed for annual servicing. The total number of persons allowed on board is limited to 25 until the IBA is re-installed to the satisfaction of an attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2020
Resolved 24 November 2020
Resolution: Received photos of satisfactory reinstallation and servicing certificate.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 4 April 2020 Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detection and alarm unit in compliance with § 181.450. Vessel's crew overnight accommodation spaces do not have required UL217 smoke detectors installed. Install required detectors in all overnight accom spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2020
Resolved 14 April 2020
Resolution: UL217 smoke detectors installed in all required spaces.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 March 2019 Resolved
C/R approximate section of WTB located at frame 13. Bulkhead was corroded and need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 April 2019
Resolution: Vessel completed C/R and water tested, all sat.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 5 October 2017 Resolved
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 November 2017
Resolved 26 October 2017
Resolution: IBA installed correctly.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 10 August 2017 Resolved
THE VESSEL'S 30-PERSON IBA HAS BEEN REMOVED FOR ANNUAL SERVICING. THE TOTAL NUMBER OF PERSONS ALLOWED ON BOARD IS LIMITED TO 24 UNTIL THE IBA HAS BEEN RE-INSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Due 10 September 2017
Resolved 16 August 2017
Resolution: Verified installation and servicing of IBA.
Lifesaving › Inflatable Liferafts › Servicing
Issued 12 October 2016 Resolved
THE VESSEL'S 25-PERSON INFLATABLE LIFE RAFT HAS BEEN REMOVED FOR SERVICING. TOTAL PERSONS ALLOWED ON BOARD IS LIMITED TO 30 UNTIL THE LIFE RAFT IS REINSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 November 2016
Resolved 26 October 2016
Resolution: Verified satisfactory re-installation of serviced life raft.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 11 July 2016 Resolved
The vessel's 30-person IBA has been removed to annual servicing. Total persons allowed on board is limited to 25 until IBA has been re-installed to the satisfaction of an attending marine inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2016
Resolved 17 August 2016
Resolution: IBA maintenance completed by LRSE and IBA reinstalled onboard vessel.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 13 April 2016 Resolved
Replace all expired life jacket lights to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 27 April 2016
Resolution: Recieved email and purchase statement from vessel rep. documenting the purchase and installation of new water lights.

Casualty record · 7

28 April 2002Routine · role: Involved in a Marine Casualty · 2 injured · activity 1627966
2 March 2004Routine · role: Involved in a Marine Casualty · activity 2039425
15 August 2008Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · activity 3302356
3 January 2009Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 2 dead · activity 3387918
9 December 2009Routine · role: Involved in a Marine Casualty · activity 3647500
23 March 2010Routine · role: Transiting Vicinity of Primary Subject · activity 3702414
28 May 2016Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · activity 5893954
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEABULK HOUSTON (2002–2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.