MAJESTY

MAJESTY is a 1984 passenger vessel (inspected). The Coast Guard has recorded 105 inspections since 1985, most recently in August 2025, along with 125 deficiencies — 1 with no resolution recorded — and 3 casualty investigations between 2005 and 2016.

Records from 1985 to 2025. Most recent: inspection, 27 August 2025.

Built
1984
Last inspected
27 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE6843
231763
Flag
UNITED STATES
367385630
Maury page id
psix-231763

Inspections, by type

…with no type recorded10
…past their stated due date1
Years with a record 38 calendar years (1985–2025)
The 105 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)113.0 ft × 31.0 ft × 9.0 ft
Registered tonnagegross 92 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1984
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE6843MMSI 367385630 · active · compulsorily equipped · granted 6 September 2018, expires 22 November 2028
WST3634MMSI 366929760 · cancelled · compulsorily equipped · granted 6 March 2004, cancelled 31 March 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PAULA Passenger (Inspected) · MISLE 58839 · 28 May 2016 · activity 5893954GATEWAY ENDEAVOR Passenger (Inspected) · MISLE 258403 · 28 May 2016 · activity 5893954ASTERIA Passenger (Inspected) · MISLE 478192 · 28 May 2016 · activity 5893954SANCTUARY Passenger (Inspected) · MISLE 489830 · 28 May 2016 · activity 5893954

Inspection history · 105

27 August 2025 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8219273
30 April 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8124220
19 April 2025 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8129094
12 December 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8046937
4 December 2024 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8043694
19 September 2024 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8005598
10 May 2024 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7910092
31 July 2023 Damage Survey · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7764065
20 April 2023 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7738438
20 January 2023 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7623358
16 December 2022 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7610039
20 August 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7292192
24 May 2021 Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7205542
20 May 2020 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6952986
24 October 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6841097
21 August 2019 Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6790149
12 April 2019 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6662647
11 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6537761
6 August 2018 MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6502725
4 May 2018 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6405627
16 October 2017 Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6288857
1 September 2017 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6256708
28 June 2017 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6189715
20 June 2017 Type not recorded
No type recorded · Base Support Unit Boston · Activity 6181721
22 March 2017 Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6109627
23 February 2017 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6093344
24 August 2016 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5988522
29 May 2016 Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5894788
28 May 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5893954
3 June 2014 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4879550
15 May 2012 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4313127
3 February 2012 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4239685
15 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4208793
23 August 2011 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4124697
23 April 2009 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3459247
20 April 2009 Excursion Permit · Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3456559
15 April 2009 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3453439
2 December 2008 MTSA Verification · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3372459
11 August 2008 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3297588
26 July 2007 MARPOL Annex V Examination · Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3008150
11 April 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2905754
3 August 2006 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2739916
3 October 2005 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2506838
2 October 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2508958
19 April 2005 Deficiency Check · COI Inspection · MARPOL Annex V Examination · MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2338416
29 March 2005 Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2322269
3 March 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2302665
1 December 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2251235
23 August 2004 MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2174385
13 April 2004 MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2042871
25 November 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1954789
12 June 2003 Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1815435
28 February 2003 Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1750690
27 June 2002 Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1637890
18 July 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1068243
27 May 2001 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1417294
26 May 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 71864
11 April 2001 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1432487
8 February 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1415542
1 May 2000 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 817011
19 April 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1423355
28 June 1999 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1079646
9 June 1999 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1460312
30 March 1999 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1418504
26 February 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 798572
25 February 1999 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1402795
8 February 1999 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1473091
9 September 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 799795
24 April 1998 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1392915
15 April 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1456585
25 February 1997 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1097332
4 February 1997 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1096933
4 March 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 884516
7 March 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1170207
19 January 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1144205
4 January 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1171479
7 December 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1140842
14 March 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165849
9 March 1994 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 854365
9 March 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 838361
14 December 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1132604
30 July 1992 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 962057
10 March 1992 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1268118
11 March 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 903935
13 February 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 911161
17 September 1990 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902792
1 June 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1218788
2 May 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 906820
17 April 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1228476
6 April 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1233370
13 March 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1241477
14 March 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1338342
2 March 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1338341
31 May 1988 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1198045
21 March 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1302120
20 October 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016256
16 September 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006117
24 August 1987 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031473
26 May 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1333212
25 March 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327182
8 April 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997911
20 February 1986 Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1292843
21 November 1985 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 994153
3 September 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1295142
3 June 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1292034

Deficiency record · 125

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 April 2025 No resolution recorded
13101 - This part contains requirements for the design, construction, installation, and operation of propulsion and auxiliary machinery, piping and pressure systems, steering apparatus, and associated safety systems. Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Wing clamp on port shaft packing gland was cracked. Repairs completed to the satisfaction of attending Marine Inspector. Wing Clamp to be replaced at next credit drydock (NLT 5/31/2026)
Action required: 705 - Other - as specified
Due 31 May 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2025 Resolved
This part contains requirements for the design, construction, installation, and operation of propulsion and auxiliary machinery, piping and pressure systems, steering apparatus, and associated safety systems. Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Wing clamp on port shaft packing gland is cracked. Repair must be made proir to getting underway with passengers. Pier side dinner cruise is authorized until 21Apr2025.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2025
Resolved 21 April 2025
Resolution: Deficiency was repaired and inspected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 December 2024 Resolved
13108 - Propulsion machinery must capable of operating at constant marine load under such requirements without exceeding its designed limitations. While underway the vessel's crew noticed the port side generator was running at a high temperature. The cause is still to be determined. 46 CFR 182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2024
Resolution: Received tech report for the generator.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 September 2024 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gauge. The vessels fire pump gauge was inoperable and the pressure was not able to be verified. Pressure at the hose was inadequate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2024
Resolution: Received video showing proper operation and psi of fire pump.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 19 September 2024 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Vessels public address system was inoperable on the interior passenger decks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2024
Resolution: Verified proper operation of public address system throughout vessel.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 August 2021 Resolved
Where fire extinguisher systems are not required, but are installed, the system or equipment and its installation shall meet the requirements of 46 CFR 181. The system was found to have leaks and is inoperable. Make permanent repairs to the system and provide documentation from a servicing technician that the system is fully operable. 46CFR181.05-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2021
Resolution: System inspected and servicing report reviewed, sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 August 2021 Resolved
A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17 “Dry Chemical Extinguishing Systems,” 17A “Wet Chemical Extinguishing Systems,” or other standard specified by the Commandant, and must be listed by an independent laboratory recognized by the Commandant. The vessel’s hood has not been serviced. Provide documentation of the systems servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2021
Resolution: Provided documentation of full system test, sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 August 2021 Resolved
EPIRB shall be installed to automatically float free. The vessels hydrostatic release mechanism is expired in 2018. Replace the hydrostatic release with a valid unit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2021
Resolved 1 September 2021
Resolution: EPIRB installation inspected, sat.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 20 August 2021 Resolved
Vessel is required to ensure a garbage management plan is in place. Vessel did not have a garbage management plan IAW 33 CFR part 151. Ensure the signed management plan is retained on board and posted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2021
Resolved 1 September 2021
Resolution: waste management plan inspected, sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 May 2021 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] the extent of material defect and mark repairs in kind at the following identified locations to the satisfaction of the attending marine inspector: (1) Hole identified on the stbd bow rub rail (2) 02 most outboard wasted frames and numerous holes in the deck on the stbd quarter. (3) Marked area on port quarter deck.
Action required: 705 - Other - as specified
Resolved 1 June 2021
Resolution: Repairs were made to the damaged plate identified on the stbd bow, port quarter deck area and the frames and holes on the stbd quarter. Conducted visual inspection of all repairs and associated weldment. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018 Resolved
Vsl is broadcasting no IMO #, no dimension information (AIS Antenna Position ABCD values equals 0) and no static draft information.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 21 August 2019
Resolution: AIS WAS REPAIRED BY TECHNICIAN
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2017 Resolved
Enclose exposed wires in FWD head
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Exposed wires enclosed in outlet box.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 1 September 2017 Resolved
Remove excess paints, thinners and alcohol gels.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Combustible materials removed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 September 2017 Resolved
Mount electrical box's near sprinkler head tank #1 and engine room bilge pump boxes
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Electrical boxes mounted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 1 September 2017 Resolved
Mount fire extinguisher behind the bar and in the pilot house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Extinguishers for bar and pilot house are mounted.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 1 September 2017 Resolved
Mark emergency escape for galley and engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Both emergency escapes marked.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 1 September 2017 Resolved
Prove proper operation of fire door separating the galley and accommodation space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Witnessed proper operation of fire door.
Engineering › Lubricating Oil Service System › Manifold
Issued 1 September 2017 Resolved
Replace both generators by NOV 1st, 2017
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 12 December 2017
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 September 2017 Resolved
Remove hold back device and install sill/jam of fire door separating bridal suite and main accommodation space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 26 September 2017
Resolution: A threshold has been installed. The holdback device is authorized.
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 1 September 2017 Resolved
Pack wire penetration separating pilot house from female head with approved fire stop material.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Observed penetration packing/fire stop material.
Engineering › Bilge Water Management System › Strainer
Issued 1 September 2017 Resolved
Replace bilge strainer in galley. Current strainer does not have enough open area.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Bilge strainer replaced.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 September 2017 Resolved
Remove hold back device and install latch on fire door separating female head and 2nd deck bar.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 1 September 2017
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 1 September 2017 Resolved
Adjust shaft packing on port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Observed satisfactory operation of port side shaft packing.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 September 2017 Resolved
Man overboard arrangements are not adequate to recover a helpless victim from the water. Demonstrate procedures for recovery of a helpless victim.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2017
Resolved 1 September 2017
Resolution: Recived e-mail from vessel master attensting to additional arrangements to assist in recovery of a helpless victim.
Construction/Loadline › Hull › Side Shell
Issued 11 May 2017 Resolved
Properly repair wasted pipe guard on STBD FWD bow in front of the main deck windows.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 4 May 2018
Resolution: Received photo evidence of sat repair.
Construction/Loadline › Hull › Side Shell
Issued 11 May 2017 Resolved
Properly repair the STBD side lower fender plate from the 5th to the 7th windows forward.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 June 2017
Resolved 30 November 2017
Construction/Loadline › Hull › Side Shell
Issued 11 May 2017 Resolved
Properly repair the port side rub rail half pipe from the loading door forward approximately 20' where holed/ wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 4 May 2018
Resolution: Received photo evidence of sat repair.
Construction/Loadline › Hull › Bottom Plating
Issued 11 May 2017 Resolved
Reinstall concrete in sewage tank to original condition. Approximately to top of keel with exception of two sumps.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 26 October 2017
Construction/Loadline › Hull › Bottom Plating
Issued 23 February 2017 Resolved
Crop and renew to good metal the bottom plating and associated framing in the galley starboard side. The vessel is restricted to Boston Harbor.
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 30 October 2017
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 August 2016 Resolved
Permanently hardwire electrical receptacle on stbd side of steering consol. Or alternatively remove.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 7 September 2016
Resolution: Electrical outlet was permanently hardwired on the stbd side of the steering console.
Electrical › Electric Supply System (service) › Cable
Issued 24 August 2016 Resolved
Permanently hardwire electrical equipment connected to 02 power strips installed on stbd side of steering consol.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 7 September 2016
Resolution: The power strip cords were removed from under the steering console. The remaining electrical equipment was permanently hardwired.
Electrical › Electric Supply System (service) › Cable
Issued 24 August 2016 Resolved
Remove extension cord in engine room powering air compressor. Make permanent electrical cord for power.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 7 September 2016
Resolution: Extension cord in engine room was removed and a permanent cord was installed for air compressor power.
Construction/Loadline › Hull › Transverse Frame
Issued 24 August 2016 Resolved
Several transverse frames were found wasted in vessel's bilge in galley room. Vessel is restricted to Boston Harbor and Harbor Islands and not more than 1 mile from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 26 October 2017
Resolution: 5/2017 the port side framing is completed and several frames on the starboard side have been doubled. In Nov 2017 the remainder of the bottom in the galley will be replaced along with the wasted framing.
Construction/Loadline › Hull › Hull Plating
Issued 29 May 2016 Resolved
Due to grounding vessel must complete insternal structural exam conducted by CGMI and also conduct a dive survey to be reviewed by attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2016
Resolution: All requirements completed.
Engineering › Bilge Water Management System › Interface Detector
Issued 3 June 2014 Resolved
audible alarm inoperable, make repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2014
Resolution: repaired, tested sat.
Fire Fighting › Fire Pumps › Pressure
Issued 3 June 2014 Resolved
No pressure gage installed and pressure inadequate. Install gage, demonstrate 6o psi.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2014
Resolution: Installed pressure gage and demonstrated 60 psi.
Documentation › Markings/Placards › Warning Signs
Issued 3 June 2014 Resolved
Escape hatch from engine room not marked and obstructed. Mark emergency escape hatch, do not block and remove obstruction.
Action required: 705 - Other - as specified
Due 18 June 2014
Resolved 19 June 2014
Resolution: Marked emergency escape hatch and removed obstructions.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 3 June 2014 Resolved
Home port not marked on transom. Mark transom with home port.
Action required: 705 - Other - as specified
Due 18 June 2014
Resolved 19 June 2014
Resolution: Marked home port on transom.
Documentation › Markings/Placards › Capacity Marking
Issued 3 June 2014 Resolved
Upper most deck max passenger capacity not accurately marked. Mark capacity wit correct number 177.
Action required: 705 - Other - as specified
Due 18 June 2014
Resolved 19 June 2014
Resolution: Marked upper deck capacity correctly.
Electrical › Lighting (service) › Lighting Fixture
Issued 3 June 2014 Resolved
Engine room lights missing all covers. Cover light fixtures as per design.
Action required: 705 - Other - as specified
Due 18 June 2014
Resolved 19 June 2014
Resolution: Installed all light covers in engine room.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 3 June 2014 Resolved
Shaft seal on port and stbd shafts leaking excessively. Repair/adjust as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2014
Resolution: Adjusted shaft seals on port and stbd shafts, tested sat.
Engineering › Bilge Water Management System › Piping
Issued 3 June 2014 Resolved
Bilge suction strainer for Galley bilge clogged. clear strainer, test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2014
Resolution: Cleaned strainer, tested sat.
Documentation › Markings/Placards › Capacity Marking
Issued 16 May 2012 Resolved
Upper deck capacity must be posted in accordance with current stability letter.
Due 25 May 2012
Resolved 11 June 2012
Resolution: Upper deck capacity is posted in accordance with current stability letter.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 May 2012 Resolved
Battery boxes must be cleaned and properly stowed with dunnage. Provide non-corrosive lining.
Due 22 June 2012
Resolved 22 June 2012
Resolution: Provide non-corrosive lining for all batteries.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 May 2012 Resolved
Provide covers for vented caps on batteries.
Due 22 June 2012
Resolved 22 June 2012
Resolution: Provided covers for vented caps on batteries
Engineering › Bilge Water Management System › Piping
Issued 16 May 2012 Resolved
Properly wire and install bildge pumps for port and stbd aft engine room.
Due 25 May 2012
Resolved 11 June 2012
Resolution: Properly wired and installed bildge pumps for port and stbd aft engine room.
Documentation › Certificates/Documents › Tanker Maneuvering Capability Letter
Issued 15 December 2011 Resolved
The vessel's owner/operator has not requested an initial or updated stability letter or has not certified compliance with the revised stability criteria for assumed average weight per person (AAWPP) of 185 pounds. Based upon a weight ratio calculation, the vessel's capacity is therefore limited to: 263 persons (passengers and crew). 46 CFR 170.090
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 3 February 2012
Resolution: New stability letter recieved from Marine Safety Center.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 23 April 2009 Resolved
Mounting arrangement of vessels rescue platform not suitable for safe and timely recovery of a person in the water.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 6 May 2009
Resolution: Platform repaired sat.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 April 2009 Resolved
Vessel currently does not have a vald FIRE CONTROL PLAN in accordance with 46 CFR 116.530. Owner required to submit plan in accordance with regulations to CG for approval.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 6 May 2009
Resolution: Fire control and evac plan provided sat.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 23 April 2009 Resolved
Vessel currently does not have a vald Emergency Evacuation Plan in accordance with 46 CFR 116.520. Owner required to submit plan in accordance with regulations to CG for approval.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 6 May 2009
Resolution: evac plan provided sat.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 26 July 2007 Resolved
Provide Senior Deckhand letters onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2007
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 26 July 2007 Resolved
Provide proof of enrollment of crew in Drug Testing Program IAW 46 CFR Part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 3 August 2006 Resolved
Provide updated US Coast Pilot IAW 46 CFR 121.420.
Due 24 August 2006
Resolved 14 September 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 August 2006 Resolved
Provide updated CG Light List IAW 46 CFR 121.420
Due 24 August 2006
Resolved 14 September 2006
Construction/Loadline › Structures › Deck Plating
Issued 3 August 2006 Resolved
Permanently repair holed deck drain piping in lazarette IAW 46 CFR 115.802
Due 24 August 2006
Resolved 14 September 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 3 August 2006 Resolved
Provide new glass cover for remote ventilation shutdown IVO engine room door IAW 46 CFR 116.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2006
Resolution: New glass was purchased and installed.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 3 August 2006 Resolved
Post a copy of vsl fire control plan by the pilothouse IAW 46 CFR 116.530
Due 24 August 2006
Resolved 14 September 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 3 August 2006 Resolved
Provide (02) caps on fixed firefighting system for galley vent hood system IAW 46 CFR 118.425
Due 24 August 2006
Resolved 14 September 2006
Engineering › Fuel Oil Service System › Hose
Issued 3 August 2006 Resolved
Various hoses in the e/r do not meet the J-1942 standard. Replaces the hoses as discussed.
Due 3 October 2006
Resolved 10 October 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 3 August 2006 Resolved
Install covers on the light fixtures (02) 2nd deck fwd (weather deck)
Due 24 August 2006
Resolved 14 September 2006
Engineering › Bilge Water Management System › Piping
Issued 3 August 2006 Resolved
Repair the holed bilge suction pipe for the aft void.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2006
Resolution: Bilge suction pipe was replaced with new pipe.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 August 2006 Resolved
Place splice for ice maker, stbd side, 2nd deck, in a enclosure.
Due 24 August 2006
Resolved 14 September 2006
Fire Fighting › Automatic Sprinkler System › Testing Means for Pump
Issued 3 August 2006 Resolved
Prove proper operation of the automatic sprinkler system. Until requirement is satisified vsl is restricted to 150 passengers.
Due 24 August 2006
Resolved 14 September 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 3 October 2005 Resolved
Replace inoperable emergency lighting fixtures.
Condition: Unknown
Due 11 October 2005
Resolved 6 October 2005
Resolution: Replaced.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 3 October 2005 Resolved
Install cover on P/S 01 deck emergency lighting fixture.
Condition: Unknown
Due 11 October 2005
Resolved 6 October 2005
Resolution: Repaired.
Fire Fighting › Fire Pumps › Pressure
Issued 19 April 2005 Resolved
Prove proper operation of main and aux fire pumps up to 50 PSI, vessel restricted from commercial service, no-sail.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2005
Resolved 4 May 2005
Resolution: Viewed proper operation of main and aux fire pumps, pressure went up to 80 psi. Vsl no longer restricted from commercial service.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 April 2005 Resolved
Replace/prove proper operation of emergency lighting in galley and female head on 01 deck.
Due 26 April 2005
Resolved 4 May 2005
Resolution: Emergency lighting fixtures in the galley and female head on the 01 deck were replaced.
Electrical › Electrical Distribution System (service)
Issued 13 April 2004 Resolved
Repair or replace broken circuit breaker panel doors at the following areas: upper deck galley, entrance to engine room, access space behind mens room lower deck.& galley ivo sprinkler pump.
Due 13 May 2004
Resolved 3 June 2004
Accommodation/Occupational Safety › Potable Water System
Issued 13 April 2004 Resolved
Make permanent repair to wasted elbow for bar drain in void space under bar stbd side aft.
Due 13 May 2004
Resolved 3 June 2004
Deck/Cargo › Holds/Tanks
Issued 13 April 2004 Resolved
Replace missing or dry rotted gasket on p/s midship main deck cargo doors. LEGACY COMPONENT DESC: Watertight Door
Due 13 May 2004
Resolved 3 June 2004
Electrical › Electrical Distribution System (service)
Issued 13 April 2004 Resolved
Make permanent repairs to electrical cords under bridge console ( remove extension cords/surge protector) LEGACY COMPONENT DESC: Wiring
Due 13 May 2004
Resolved 3 June 2004
Construction/Loadline › Hull
Issued 13 April 2004 Resolved
Renew deck stiffener at bottom of ladder to galley entrance. LEGACY COMPONENT DESC: Stiffener
Due 13 May 2004
Resolved 3 June 2004
Accommodation/Occupational Safety › Cooking Systems
Issued 13 April 2004 Resolved
Install sea rails on galley stoves.
Due 13 May 2004
Resolved 3 June 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 June 2003 Resolved
Repare Stbd running light so that it does not go on and off everytime you touch it.
Due 12 June 2003
Resolved 12 June 2003
Electrical › Lighting (service) › Switch
Issued 12 June 2003 Resolved
Replace light switch covers in Linen closet and bar area on 2nd deck.
Due 20 June 2003
Resolved 24 June 2003
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 12 June 2003 Resolved
Post Emergency Broadcast Placard.
Due 12 June 2003
Resolved 12 June 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 June 2003 Resolved
Replace electrical cord to the frezer in galley.
Due 20 June 2003
Resolved 24 June 2003
Accommodation/Occupational Safety › Heating
Issued 12 June 2003 Resolved
Clean out and repair leak in small water heater in galley. LEGACY COMPONENT DESC: Water heater tank
Due 20 June 2003
Resolved 27 June 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 June 2003 Resolved
Remove improper wiring and properly splice wire leading to radio on bridge.
Due 12 June 2003
Resolved 12 June 2003
Electrical › Electrical Distribution System (service)
Issued 12 June 2003 Resolved
Install cover to distribution panel IWO E/R access on main deck. LEGACY COMPONENT DESC: Panelboard
Due 20 June 2003
Resolved 24 June 2003
Engineering › Freshwater System (intermediary cooling)
Issued 12 June 2003 Resolved
Replace keel cooler flex hose to stbd MDE LEGACY COMPONENT DESC: Keel Cooler Line
Due 20 June 2003
Resolved 24 June 2003
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 12 June 2003 Resolved
Install non-conductive matting to E/R deck on backside of Main Distribution panel.
Due 20 June 2003
Resolved 24 June 2003
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 June 2003 Resolved
Make lazarette fwd bulkhead penetrations water tight.
Due 20 June 2003
Resolved 24 June 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 12 June 2003 Resolved
Intall covers on two flourescent lights in galley.
Due 20 June 2003
Resolved 27 June 2003
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 June 2003 Resolved
Replace receptical outlets at entrance to galley.
Due 20 June 2003
Resolved 24 June 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 12 June 2003 Resolved
Install covers to four flourescent lights in E/R.
Due 20 June 2003
Resolved 24 June 2003
Construction/Loadline
Issued 14 May 2002 Resolved
Replace cracked window, port side upper deck on "door" entry to bow weather deck.
Due 14 June 2002
Resolved 11 June 2002
Resolution: Window replaced. JJJ
Construction/Loadline
Issued 14 May 2002 Resolved
PAX restricted at "03" level until guard rails permanently repaired.
Due 14 June 2002
Resolved 11 June 2002
Resolution: Rails permanently repaired. [name withheld]
Navigation
Issued 27 May 2001 Resolved
Prior to operating steering solenoid mechanizm with passengers, contact Marine inspector to verify satisfactory operation.
Condition: Unknown
Due 27 May 2001
Resolved 27 May 2001
Documentation
Issued 27 May 2001 Resolved
Submit CG-2692 by 31MAY01.
Condition: Unknown
Due 22 June 2001
Resolved 22 June 2001
Electrical
Issued 11 April 2001 Resolved
Provide proper power distribution for items on extension cords, port side upper fwd bulkhead in galley.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Electrical
Issued 11 April 2001 Resolved
Provide proper power distribution for lighting circuit in E/R access trunk.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Lifesaving
Issued 11 April 2001 Resolved
Mark entrances to upper deck with 205 person limit IAW stability letter.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Fire Fighting
Issued 11 April 2001 Resolved
Make repairs/renew ventilation switch at E/R trunk and re-test shut downs with USCG.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Fire Fighting
Issued 11 April 2001 Resolved
Clean and prove proper operation of fusible link cable to galley fire extinguisher (third party certificate OK).
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Electrical
Issued 11 April 2001 Resolved
Remove heat tape from cold water pipe in galley.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Fire Fighting
Issued 11 April 2001 Resolved
Vessel is restricted from cooking grease producing foods until galley fixedfoam fire extinguishing system is re-assembled after hydro of bottles.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Navigation
Issued 11 April 2001 Resolved
Provide a 12"(300 mm) bell in accordance with Nav Rules technical requirements for vessels >65 ft.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Electrical
Issued 11 April 2001 Resolved
Prove proper operation of overspeed trip on stbd generator.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Fire Fighting
Issued 11 April 2001 Resolved
Remove carpet from under fire door to galley.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Accommodation/Occupational Safety
Issued 8 February 2001 Resolved
Repair rails iwo port quarter prior to carrying passengers
Condition: Unknown
Due 8 March 2001
Resolved 28 February 2001
Fire Fighting
Issued 8 February 2001 Resolved
Replace sea suction butterfly valve for sprinkler system.
Condition: Unknown
Due 28 February 2001
Resolved 12 February 2001
Engineering
Issued 8 February 2001 Resolved
Inspect/clean all fuel oil vent/flame screens
Condition: Unknown
Due 8 March 2001
Resolved 28 February 2001
Lifesaving
Issued 19 April 2000 Resolved
replace retro-reflective tape on PFDs as needed.
Condition: Unknown
Due 1 May 2000
Resolved 5 May 2000
Lifesaving
Issued 19 April 2000 Resolved
Properly label location fo PFDs
Condition: Unknown
Due 1 May 2000
Resolved 5 May 2000
Lifesaving
Issued 19 April 2000 Resolved
Replace weak links on life floats.
Condition: Unknown
Due 21 April 2000
Resolved 5 May 2000
Lifesaving
Issued 25 February 1999 Resolved
Provide proposal to meet rescue boat requirements 46 CFR 180.10-35/117.210 and NYCMI Policy 1/89. If rescue boat is provided it must meet requirements of 46 CFR 160.056.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Lifesaving
Issued 25 February 1999 Resolved
Replace missing buoyant apparatus as required by COI (8 BA's). Vessel can carry 280 total persons, until this requirement is completed to the satisfaction of an attending marine inspector.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Lifesaving
Issued 25 February 1997 Resolved
REPAIR/PATCH SURFACE DEFECTS IN BOUYANT APPARATUS.
Condition: Unknown
Due 4 March 1997
Resolved 25 February 1997
Lifesaving
Issued 25 February 1997 Resolved
GALLEY GRILL/OVEN & AREA AJACENT TO RANGE HOOD HAS EXCESSIVE GREASE BUILDUPCREATING AN UNSANITARY & FIRE HAZARD CONDITION. DEGREASE GALLEY AND_x001C_ MAINTAIN IN GREASEFREE CONDITION.
Condition: Unknown
Due 4 March 1997
Resolved 18 April 1997
Construction/Loadline
Issued 4 January 1995 Resolved
CONDUCT BELT GAUGINGS. SEND RESULTS TO [name withheld].
Condition: Unknown
Due 4 January 1995
Resolved 4 January 1995
Accommodation/Occupational Safety
Issued 4 January 1995 Resolved
PROVE PROPER OPERATION OF ESCAPE HATCH IN STEERING COMPARTMENT.
Condition: Unknown
Due 4 January 1995
Resolved 4 January 1995
Construction/Loadline
Issued 4 January 1995 Resolved
PERMANENTLY MARK DRAFT MARKS ON VSL'S BOW AND STERN.
Condition: Unknown
Due 4 January 1995
Resolved 4 January 1995
Accommodation/Occupational Safety
Issued 4 January 1995 Resolved
MARK THE GALLEY EMERGENCY ESCAPE BOTH INSIDE, OUTSIDE, AND THE STEERING EMERGENCY ESCAPE.
Condition: Unknown
Due 4 January 1995
Resolved 4 January 1995
Engineering
Issued 4 January 1995 Resolved
MAKE ENGINEROOM BATTERY BOXES LEAK PROOF. (LEAD ACID LEAKING INTO BILGES CAUSING CORROSION.)
Condition: Unknown
Due 4 January 1995
Resolved 4 January 1995
Construction/Loadline
Issued 4 January 1995 Resolved
INSTALL PROPER WATERTIGHT BULKHEAD PENETRATIONS IN STEERING COMPT STBD SIDE, AND IN THE MEN'S HOT WATER HTR COMPARTMENT.
Condition: Unknown
Due 4 January 1995
Resolved 4 January 1995
Construction/Loadline
Issued 4 January 1995 Resolved
MAKE READY FOR INSPECTION THE BILGE AREA BELOW THE GALLEY. (BILGES FULL OF GREASE SANITATION ISSUE)
Condition: Unknown
Due 4 January 1995
Resolved 4 January 1995
Construction/Loadline
Issued 7 December 1994 Resolved
MAKE VESSEL AVAILABLE FOR CREDIT DRYDOCKING NLT 09JAN95.
Condition: Unknown
Due 7 December 1994
Resolved 7 December 1994
Unknown
Issued 9 March 1994 Resolved
REMOVE TEMPORARY PATCH AND MAKE PERMANENT REPAIR TO SANITARY DRAIN LINE LOCATED IN FIRST VOID AFT OF FOREPEAK.
Condition: Unknown
Due 9 March 1994
Resolved 9 March 1994
Navigation
Issued 10 March 1992 Resolved
REPAIR RUDDER FOLLOW UP UNIT HOUSING IN LAZARETTE.
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Navigation
Issued 10 March 1992 Resolved
DOUBLE NUT PORT HYDRAULIC STEERING GEAR RAM.
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Construction/Loadline
Issued 13 February 1991 Resolved
REPAIR BROKEN RUB-BAR-PORT SIDE.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Electrical
Issued 13 March 1990 Resolved
ELIMINATE THE FAULT IN THE GROUND FAULT DETECTION SYSTEM; LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 13 March 1990
Resolved 13 March 1990
Fire Fighting
Issued 13 March 1990 Resolved
PROPERLY TEST THE FIXED DRY CHEMICAL FIRE EXTINGUISHING SYSTEM IN THE GALLEY RANGE; ASSURE LINES ARE CLEAR, CABLE AND JOINTS ARE FREE, ACTUATOR NOZZEL IS FUNCTIONAL OR REPLACE THE SYSTEM.
Condition: Unknown
Due 13 March 1990
Resolved 13 March 1990
Accommodation/Occupational Safety
Issued 26 May 1987 Resolved
SUBMIT PLANS FOR REVIEW FOR PROPER INSTALLATION OF DECORATIVE LIGHTS OR REMOVE PRESENTLY INSTALLED DECORATIVE LIGHTS.
Condition: Unknown
Due 26 May 1987
Resolved 26 May 1987

Casualty record · 3

2 October 2005Routine · role: Involved in a Marine Casualty · activity 2508958
10 July 2010Routine · role: Involved in a Marine Casualty · activity 3793284
28 May 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 5893954
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

LORIANNA (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.