Records from 2005 to 2025. Most recent: inspection, 3 November 2025.
Inspection history · 55
3 November 2025
ISM Oversight · ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8268528
22 July 2025
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8191951
14 May 2025
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8135607
31 March 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8102989
13 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8034462
8 July 2024
Drydock Exam · Periodic Inspection · Internal Structural Exam · In-Service Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7953315
8 June 2023
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7706702
8 August 2022
Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7499837
1 July 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7492326
1 June 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7465388
24 May 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7458102
20 September 2021
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7301974
3 August 2020
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7023642
21 July 2020
Periodic Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7012429
23 January 2020
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6895378
11 September 2019
MTSA Verification · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6808096
9 July 2019
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6742913
5 May 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6677334
27 June 2018
Deficiency Check · Annual Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6455051
5 March 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6366365
7 November 2017
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6302463
31 May 2017
Examination of Repairs · Cargo Tank Internal · Administrative Inspection · Construction Oversight · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6161756
24 February 2016
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5825736
2 February 2015
Administrative Inspection · COI Inspection · MTSA Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5061592
12 January 2015
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5050231
17 September 2014
MARPOL Annex IV Survey · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4986685
5 September 2014
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4974444
23 October 2013
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4739762
13 September 2013
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4713996
27 July 2013
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4666084
18 July 2013
Deficiency Check · Periodic Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4660998
19 December 2012
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4504680
27 August 2012
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4423336
26 July 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4388159
21 May 2012
Construction Oversight · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4317986
2 November 2010
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3883185
18 May 2010
MTSA Verification · COI Inspection · MARPOL Annex IV Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3741096
21 January 2010
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3667181
10 September 2009
Annual Inspection · MARPOL Annex V Examination · MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3591050
8 January 2009
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3393939
3 January 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3387918
22 September 2008
Deficiency Check · Periodic Inspection · MTSA Verification · MARPOL Annex I Examination · MARPOL Annex V Examination · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3330047
7 January 2008
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3125814
23 August 2007
MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3036515
12 February 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2871257
21 December 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2844306
17 November 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2830057
26 October 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2808563
20 September 2006
MARPOL Annex II Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2782681
15 September 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2778896
14 September 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2778356
17 February 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2587357
25 January 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2574033
22 June 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2399062
3 January 2005
Initial Certification · Internal Structural Exam · Cargo Tank Internal · Hull Examination · MTSA Verification
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2375462
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 June 2023
Resolved
The frame or support of each size III, IV, and V fire extinguisher required by table 34.50-10(a) must be welded or otherwise permanently attached to a bulkhead or deck.
Forward & aft semi-portable fire extinguishers were found ratchet strapped to bracket on deck.
46 CFR 34.50-20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2023
Resolved 9 June 2023
Resolution: Vessel rep povided proof of permanent installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 June 2023
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapors, gases or liquids whose temperature exceeds 150 °F., shall be suitably insulated where necessary to preclude injury to personnel.
Exhaust flange shield missing from elbow after turbocharger on #2 generator.
46 CFR 56.50-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2023
Resolved 9 June 2023
Resolution: Vessel rep povided proof of flange shield installation.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 July 2022
Resolved
Every tank vessel subject to the regulations in this subchapter shall be inspected every 5 years. Vessel COI expired on 30 June 2022. Vessel is permitted one-way transit to Morgan City, LA to conduct routine drydock. Vessel must remain in a gas-free state until issued a new COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 August 2022
Resolution: Vessel given Issued/Effective COI
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 September 2021
Resolved
If the voltage of a distribution system is less than 1,00 volts, a tank vessel must not have a grounded distribution system.
A ground was detected via the ground detection at the 480 V panel.
Provide electrician report that ground has been eliminated.
46 CFR 111.05-19(a), 705 c- rectify def in 7 days
Action required: 705 - Other - as specified
Due 27 September 2021
Resolved 21 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 July 2020
Resolved
#1 Generator was not onboard at the time of inspection. Prove proper operation and conduct test of alarms and shutdowns prior to use in service in presence of attending CG marine inspector.
Action required: 705 - Other - as specified
Resolved 3 August 2020
Resolution: Generator installed and conducted visual inspection, overspeed trip, and low lube oil shutdown.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 July 2020
Resolved
The thermal fluid heater was not operated or tested during the inspection due to type of cargo onboard. Prove proper operation and conduct operational tests and checks in presence of attending CG marine inspector prior to operation of the thermal fluid heater.
Action required: 705 - Other - as specified
Resolved 5 August 2020
Resolution: Company informed CG the thermal fluid heater has been locked out, tagged out of service.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 July 2020
Resolved
The #2 generator expansion tank is leaking into unknown area. Find source of leak and make repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2020
Resolution: ABS surveyor oversaw repair and provided report attesting to repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 July 2020
Resolved
A hydraulic leak was identified on the starboard side crane. Make repairs and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2020
Resolution: Third party company conducted repairs to hydraulic winch. Reviewed service report.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 22 July 2020
Resolved
#1 Starboard Cargo hatch cover was leaking cargo vapors when closed. Make adjustments and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2020
Resolution: Cargo hatch cover gasket replaced. Conducted leak test with complressed air via manometer and soapy water solution inspecting area for leaks. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 July 2020
Resolved
Wire channels under the starboard deck house are wasted out. Make repairs and prove satisfaction to CG inspector
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2020
Resolution: Wire channels replaced, attending MI inspected. All sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 22 July 2020
Resolved
Steel wastage was identified underneath both deck houses. Gauge suspect areas and prove sufficient steel to prevent load line and vapor tightness concerns.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 August 2020
Resolution: ABS oversaw repairs and provided report attesting to temporary repairs scheduled to be permanently repaired on their next scheduled dry dock.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 July 2020
Resolved
Renew faded SOLAS stickers on each deck house.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2020
Resolution: New stickers were installed and verified by attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 September 2019
Resolved
Replace expired batteries in lifebuoy self-igniting lights. 46 CFR 199.70(a)(3)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2019
Resolution: Received e-mailed receipts and photos of replacement batteries on GM 11103.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2019
Resolved
Replace the portable fire extinguisher brackets located on the starboard bow and aft of the starboard manifold with approved fire extinguisher brackets. 46 CFR 34.05-10
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2019
Resolution: Received e-mailed receipts and photos of replacement fire extinguisher brackets installed on GM 11103.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2018
Resolved
Prove proper operation of overspeed and low lube oil shutdowns on the #2 auxiliary generator prior to running generator.
46 CFR 111.12-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2018
Resolved 12 July 2018
Resolution: Received report from tech, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2018
Resolved
Current Load Line shall be marked with contrasting color.
46 CFR 42.13-40
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 June 2018
Resolved 28 June 2018
Resolution: Load line was painted during inspection.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 2 February 2015
Resolved
The installed life rafts were not mounted in a way that they could be easily deployed over the side of the vessel. The raft would have had to be thrown at least 7 feet to clear the main deck. As such required vessel to install a launching device to ensure that the rafts would not crash on the deck below when deployed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2015
Resolution: The vessel''s crew welded "ramps" for each liferaft to allow for easy deployment over the side of the vessel. Cleared at end of inspection. Crew used pipes welded to the superstructure to accomplish this.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 5 September 2014
Resolved
Vessel crew could not demonstrate proper operation of the #2 and #3 ships generator under voltage relay. Prove proper operation of under voltage relays.
Action required: 705 - Other - as specified
Due 5 October 2014
Resolved 17 September 2014
Resolution: Vessel has replaced under voltage for the #2 and #3 generator tested both generators - all sat.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 5 September 2014
Resolved
Crew could not prove proper operation of the #1, #2, and #3 ships generators high engine temperature alarms. Prove proper operation of the high temperature alarms.
Action required: 705 - Other - as specified
Due 5 October 2014
Resolved 17 September 2014
Resolution: Completed testing of High engine temperature alarm on all 3 generators - all sat
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 5 September 2014
Resolved
Crew failed to prove operation of #2 ships generators loss of lube oil alarm.
Action required: 705 - Other - as specified
Due 5 October 2014
Resolved 5 October 2014
Resolution: Crew replaced faulty alarm sensor and proved proper operation of engine alarm to the attending marine inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 18 July 2013
Resolved
Operator could not perform reverse power relay test.
Action required: 705 - Other - as specified
Due 18 August 2013
Resolved 19 July 2013
Resolution: Operator successfully completed reverse power relay test with Coast Guard Inspector.
Deck/Cargo › Cargo Heating › General
Issued 18 July 2013
Resolved
Operator could not start thermal fluid heater.
Action required: 705 - Other - as specified
Due 18 August 2013
Resolved 19 July 2013
Resolution: Operator successfuly started thermal fluid heater and tested alarms.
Engineering › Fuel Oil Service System › Hose
Issued 18 July 2013
Resolved
Fuel hoses on generators were longer than 30 inches and were not SAE J1942.
Action required: 705 - Other - as specified
Due 2 September 2013
Resolved 11 September 2013
Resolution: Vessel installed fuel hose type SAE J1942 and in lenghts not exceeding 30 inches.
Lifesaving › Inflatable Liferafts › Servicing
Issued 14 January 2009
Resolved
Both barge life raft certificates of re-inspection state that raft first aid kits are expired. starboard, 10-08 and port 12-08. last sevicing was 9-08. provide proof of validity.
Action required: 705 - Other - as specified
Due 8 February 2009
Resolved 14 January 2009
Resolution: Kit remains current until next servicing date.
Electrical › Lighting (service) › Outlet Box
Issued 22 September 2008
Resolved
Repair junction box on Port side Nav light to original condition.
Action required: 705 - Other - as specified
Due 23 October 2008
Resolved 14 October 2008
Resolution: Received pictures from vessel rep with satisfactory repairs of junction box completed. Deficiency cleared.
Engineering › Generator (propulsion/auxiliary-electric) › Coil
Issued 22 September 2008
Resolved
Prove proper operation of low lube oil test on all gensets.
Action required: 705 - Other - as specified
Due 23 October 2008
Resolved 6 November 2008
Resolution: All gensets tested for low lube oil pressure shutdown, all operated satisfactory. Deficiency cleared.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 22 September 2008
Resolved
Properly stencil all oil cargo hoses Oil Service Only and MAWP 150 psi.
Action required: 705 - Other - as specified
Due 23 October 2008
Resolved 14 October 2008
Resolution: Received pictures from vessel rep showing that oil cargo hoses had been stenciled properly. Deficiency cleared.
Deck/Cargo › Cargo Heating › General
Issued 22 September 2008
Resolved
The Themal Fluid Heater was not inspected internally at last peridic inspection. TFH to be opened and visually inspected at next annual exam.
Action required: 705 - Other - as specified
Due 30 September 2009
Resolved 10 September 2009
Electrical › Electric Generation Source (service) › Generator
Issued 23 August 2007
Resolved
Demonstrate overspeed shutdown of #1 generator.
Condition: Unknown
Due 24 September 2007
Resolved 10 September 2007
Resolution: Verified proper operation of over speed shutdown on #1 generator.