Records from 1998 to 2009. Most recent: inspection, 23 July 2009.
Inspection history · 39
23 July 2009
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3546572
22 July 2009
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3542905
21 July 2009
ISPS II Exam · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3541761
12 May 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3202134
12 May 2008
ISPS I Exam
Physical examination · USCGC POMPANO (WPB 87339) · USCG East District (CGD-E) · Activity 3213488
24 March 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3170459
18 November 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3100489
29 June 2007
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2977180
24 March 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2894148
23 August 2006
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2757131
21 August 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2755337
16 March 2006
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2603843
18 January 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2568925
14 January 2006
ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2566894
23 May 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2366938
23 May 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2367749
9 May 2005
COC-TVE Renew
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2352878
5 February 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2287358
31 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2284153
7 January 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2272568
8 October 2004
ISPS III Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2216673
12 July 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2202092
16 June 2004
MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2100778
18 March 2004
Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2026770
18 March 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2027018
3 February 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1999844
14 February 2003
Certificate of Compliance · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1743839
12 April 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1604108
26 December 2001
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1475824
2 November 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 713924
22 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 169890
22 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 294009
11 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 5516
4 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293462
5 September 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 281818
10 September 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 432920
10 September 1999
Tank Vessel Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 785516
13 November 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 422526
3 September 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 420080
Deck/Cargo › Inert Gas System › IGS Blower
Issued 21 July 2009
Resolved
GAS TEMPERATURE SENSOR UNABLE TO DETECT HIGH TEMPERATURES ABOVE 65C AND NOT GENERATING ALARM AND SECURING IGS BLOWER. REPAIRS MADE BY VESSEL ENGINEERS AND REPORT MADE TO COMPANY. FSS CODE CH. 15 REG. 2.41
Due 24 July 2009
Resolved 24 July 2009
Resolution: REPAIRS MADE ON SCENE
Deck/Cargo › Ballast › Dedicated Clean Ballast Tanks
Issued 14 January 2006
Resolved
Find source of oil in #6 PBWT; submit repair proposal. SOLAS Consolidated 2004 Ch. II-1 Reg. 3-1
17 A,C-Prior to departure to the satisfaction of the Coast Guard and the vessel's Class Society.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2006
Resolved 18 January 2006
Resolution: repair proposal delayed and now rerquired completed repairs approved by class prior to arrival in US.
Deck/Cargo › Ballast › Dedicated Clean Ballast Tanks
Issued 14 January 2006
Resolved
Make permanent repair to #6 PBWT. SOLAS Consolidated 2004 Ch. II-1 Reg. 3-1
17 A,C-To satisfaction of Coast Guard and Vessel's Class Society prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2006
Resolved 18 January 2006
Resolution: Make permanent repair to #6 PBWT. SOLAS Consolidated 2004 Ch. II-1 Reg. 3-1
17 A,C-To satisfaction of Coast Guard and Vessel''s Class Society prior to arrival back in US Port.
Deck/Cargo › Ballast › Segregated Ballast Tank
Issued 14 January 2006
Resolved
Product found in #6 PBWT; segregated BWT must be cleaned via approved repair/action proposal.
MARPOL Annex 1 Reg. 13 A,F 17 A,C-Must be completed prior to departure to the satisfaction of the Coast Guard and vessel's class society.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2006
Resolved 18 January 2006
Resolution: Product found in #6 PBWT; segregated BWT must be cleaned Amended to require no discharge of ballast until class survey of cleaned ballast system
Deck/Cargo › Cargo Stowage › General
Issued 14 January 2006
Resolved
Unable to determine source of oil found in #6 port ballast tank, require class survey prior to entry into US waters.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 March 2006
Resolution: Received ABS Statutory Survey Report stating deficiency rectified.
Deck/Cargo › Ballast › Piping
Issued 14 January 2006
Resolved
Oil present in #6 port ballast tank piping, vessel required to NOT discharge ballast system until cleaned and surveyed.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 March 2006
Resolution: Received ABS Statutory Survey Report stating deficiency rectified.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 14 January 2006
Resolved
Fixed gas detection system in #6 port ballst tank (lower hold) unable to calibrate as per SMS because instrument inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 March 2006
Resolution: Received ABS Statutory Survey Report stating deficiency rectified.
Fire Fighting › Fire Hoses › Condition
Issued 9 May 2005
Resolved
Fire Hose in station on port side adjacent to Life Boat was holed and replaced prior to the completion of exam.
Action required: 705 - Other - as specified
Due 9 May 2005
Resolved 9 May 2005
Resolution: Replaced with onboard spare
Navigation
Issued 22 September 2001
Resolved
During interview of Houston Pilot #130, he mentioned there was excessive static when communicating via the radio COMMS onboard the bride of the T/S NEW AMITY. He used a hand set, which allows the user to set volume from 1 watt (low) to 5 watts (high). [name withheld] kept his setting at 1 watt.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 January 2002
Resolved 6 January 2002
Resolution: Resolved. Deficiency not part of original case conducted by HOUMS & enterred in MSIS. Conclusion is that it was erroneously transferred from MSIS to MISLE.
Construction/Loadline
Issued 22 September 2001
Resolved
Side shell damage IWO starboard quarter adjacent to fuel oil tank; SOLAS 74Am I/11; Repair to the satisfaction of the Safety Construction CertificateIssuing Authority prior to departure from the Port of Houston.
Condition: Unknown
Due 22 September 2001
Resolved 29 September 2001
Deck/Cargo
Issued 3 September 1998
Resolved
VESSEL TO PROVIDE TO USCG EVIDENCE OF THE EFFECTIVINESS TEST OF THE COW SYSTEM IN ACCORDANCE WITH VESSEL'S IOPP NO LATER THEN 01NOV98.
Condition: Unknown
Due 13 November 1998
Resolved 13 November 1998