Records from 1985 to 2025. Most recent: inspection, 16 April 2025.
Inspection history · 97
16 April 2025
Deficiency Check · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8112435
9 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8103216
8 April 2024
Deficiency Check · DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7886012
2 April 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7888990
10 July 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7736056
6 July 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7735094
21 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7611925
8 December 2022
Drydock Exam · Internal Structural Exam · Deficiency Check · Plan Review "T" Boat · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7605895
13 April 2022
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7425953
29 March 2022
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7420733
1 September 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7301932
7 July 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7254272
2 July 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7242594
21 April 2021
Internal Structural Exam · Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7188609
2 July 2020
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6991019
16 April 2019
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6661410
1 April 2019
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6653847
13 February 2018
Examination of Repairs · Deficiency Check · Internal Structural Exam · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6354045
29 January 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6346632
29 January 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6381486
10 May 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6142206
13 December 2016
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6056923
19 April 2016
Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5857479
9 November 2015
Internal Structural Exam · Plan Review (Other than "T") · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5756461
21 May 2014
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4864279
2 February 2012
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4236632
17 November 2010
Administrative Inspection · COI Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3893558
9 December 2009
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3647391
1 December 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3642223
11 December 2008
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3373965
1 December 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3369939
22 October 2008
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3358540
1 May 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3200289
28 November 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3094635
9 February 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2869953
25 January 2006
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2573004
14 December 2005
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2542537
24 February 2005
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2296790
27 January 2005
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2277385
1 March 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2016545
2 December 2003
Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1957021
3 February 2003
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1739083
21 January 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1733543
16 September 2002
MARPOL Annex V Examination · In-Service Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1705815
2 September 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1672862
1 June 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1627821
24 January 2002
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1481116
11 January 2002
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1477918
27 February 2001
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1059671
10 February 2000
Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1046320
31 July 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 168053
25 January 1999
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 789329
26 February 1998
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 800467
11 December 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 779104
23 July 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 68327
19 May 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1108521
4 July 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 93177
2 July 1996
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1087116
17 May 1996
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1082281
19 March 1996
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 886374
23 May 1995
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 873916
26 May 1994
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 862873
17 May 1994
MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1169539
22 April 1994
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 859318
28 December 1993
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 850962
24 September 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 22956
17 May 1993
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 826301
19 May 1992
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 950150
21 May 1991
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1212330
14 May 1991
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1246768
6 May 1991
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1003166
24 May 1990
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 909530
24 May 1990
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1227994
20 November 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 912642
17 November 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 911798
2 November 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1313978
16 October 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1208978
15 August 1989
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1044781
7 June 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199642
12 May 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1210709
22 February 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1343843
5 October 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1195658
23 June 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206369
24 February 1988
Hull Examination · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1023940
16 June 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1001683
10 April 1987
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1003865
24 March 1987
Hull Examination · Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1019013
20 March 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1017342
24 September 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1005190
1 July 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1297586
3 June 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1301650
21 April 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1307177
2 April 1986
COI Inspection · Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306729
15 October 1985
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1300295
4 September 1985
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1296280
1 April 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 982272
22 March 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 980254
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 April 2025
Resolved
Tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant materials, adequately protected from mechanical damage, and provided at the tank connections with devices that will automatically close in the event of rupture of the gauge or gauge lines. Marine inspector identified flexible PVC tubing used as sight glass for tank in engine room. 46 CFR 182.440(a)(7)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 14 June 2025
Resolution: Received photo evidence of corrective action to satisfaction of MI.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 16 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect.. persons, and the vessel from electrical hazards, including fire...and electrical shock. Marine inspector found broken and dead end wires at aft bulkhead of void 2 along overhead in way of the access hatch. Remove or provide proper wire terminations to the satisfaction of the MI. 46 CFR 183.200(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 14 June 2025
Resolution: Operator provided satisfactory photo evidence of addition of proper wire termination to dead end wires.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 April 2025
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Escape hatch from engine room on port side is not marked. 46 CFR 185.606
Action required: 705 - Other - as specified
Resolved 14 June 2025
Resolution: Operator provided satisfactory photo evidence of means of escape markings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 April 2025
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck. Identified inoperative valve on bilge penetration of collision bulkhead.
46 CFR 182.25-5(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 9 April 2025
Resolution: Verified operation of bilge valve.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to... minimize accidental personnel contact with energized parts. Identified dead end wires not secured properly.
46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 9 April 2025
Resolution: Received photos of capped wires.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 April 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. The adult and child life jackets were stowed together.
46 CFR 180.78(a)(5)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 28 April 2025
Resolution: Received photo of mesh bag for life jacket separation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 April 2025
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be … made watertight. The bulkhead penetration cables were not watertight.
46 CFR 179.320(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 9 April 2025
Resolution: Received photo of cable penetrations filled with putty.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2025
Resolved
Wiring joints and splices shall be mechanically secure and made in a junction box.
46 CFR 183.05-50(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 9 April 2025
Resolution: Received photos of secured splices.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2024
Resolved
Piping used in a vital system must be composed of ferrous materials. Marine inspector witnessed fractured piping to pilge suction line #3 in the engine, forward of the manifold due to galvanic corrosion. 46 CFR 182.700(c)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2024
Resolved 28 May 2024
Resolution: Bilge line repaired and tested satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 April 2024
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment...Marine Inspector observed bilge suction arrangement in lazarette void unable to draw suction. Additionally, forepeak suction inadequately slow, Marine Inspector observed pinhole leak in forward accommodation space bilge piping at aft bulkhead, and deteriorated weld at piping bulkhead penetration. It was also observed bilge manifold piping connections in engine room were leaking with pump running. Investigate and provide root cause of failures. Repair proposals, if necessary, should be provided to MI prior to any permanent repairs are made. 46 CFR 182.25-1(a) Old T
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2024
Resolved 23 May 2024
Resolution: Tested bilge suction in lazarette, void 2, and void 3, all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 April 2024
Resolved
An internal structural examination ... may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. MI observed areas of visible wastage on main engine exhaust piping on both engines aft of flexible wet exhaust piping connections to overboard piping. Remove flexible piping from fixed piping, clean and descale for further inspection. 46CFR176.610(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2024
Resolved 6 June 2024
Resolution: Port and starboard exhausts were repaired satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 April 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Marine Inspector identified leaks on hydraulic fluid storage tank piping and lube oil tank within engine room. MI observed melted and leaking flexible hose on port generator coolant expansion tank. 46 CFR 182.01-5(a) Old T
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2024
Resolved 23 May 2024
Resolution: Hose has been rerouted around hot piping and replaced. No leaks evident.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2024
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Vessel's unlicensed crew was unfamiliar with operation of vessels emergency systems to include operation of bilge sytem and fire pump. 46 CFR 185.420(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2024
Resolved 23 May 2024
Resolution: Crew operated bilge and fire pump satisfactorily without assistance.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 April 2024
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Conduct abandon ship and man overboard drill to the satisfaction of the attending marine inspector prior to carriage of passengers. 46 CFR 176.808(g)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2024
Resolved 6 June 2024
Resolution: MOB and fire drills were conducted satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Marine Inspector identified (45) life jackets in unservicable condition. Authorized number of passengers reduced to 91 until additional lifejackets are put into service. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Replaced all faulty lifejackets. Number of lifejackets onboard is in excess of required amount on COI
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2024
Resolved
Each life jacket must be marked with Type I retroreflective material. Marine Inspector identified deteriorated retroreflective material on (14) life jackets. 46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Retroreflective material replaced on faded lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2024
Resolved
At least one ring life buoy must be fitted with a lifeline...Each lifeline on a ring life buoy must: (1) Be buoyant; (2) Be of at least 18.3 meters (60 feet) in length; (3) Be non-kinking; (4) Have a diameter of at least 7.9 millimeters (5/16 inch); (5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and (6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Required lifeline was observed to be insufficient length and a light color synthetic type. 46 CFR 180.70(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 28 May 2024
Resolution: Proper lifeline provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 April 2024
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens...MI observed faded inboard screens on port and starboard and improperly installed bulb on starboard side. 33 CFR 84.04(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Inboard screens repainted matte black and bulb replaced
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 April 2024
Resolved
Electrical equipment used in the following locations must be dripproof: (1) A machinery space. Electrical outlet on forward bulkhead of machinery space used for the multi-stage battery charger is missing dripproof covering. 46 CFR 183.210(a)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Cover installed on charger.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 April 2024
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10...The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector.. Vessel was unable to provide of portable fire extinguishing equipment servicing report.46 CFR 176.810(b)(iv)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 28 May 2024
Resolution: Vessel provided satisfactory evidence of fire servicing.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 8 April 2024
Resolved
A vessel equipped with pilothouse control must have a fixed means of two-way communications from the operating station to the location where the means of controlling the propulsion machinery. MI observed a lack of effective communication between pilothouse control and crew in working areas of the vessel. 46 CFR 184.602
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2024
Resolved 23 May 2024
Resolution: Obtained handheld radios.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 April 2024
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics. Vessel drill log does not include full date of training, or description of training topics. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics. Vessel drill log does not include full date of training, or description of training topics. 46 CFR 185.420(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Master created new logbook containing additional required information.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 8 April 2024
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. MI observed the vessel was missing emergency broadcast instructions at the radiotelephone installation. 46 CFR 184.506
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Emergency broadcast placard installed at operating station
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 April 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot. Vessel missing comprehensive Coast Pilot for area of operation. 46 CFR 184.420(a)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Current extracts of Coast Pilot printed and onboard.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 8 April 2024
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited ... the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include— (1) Closing each valve leading to an overboard discharge and removing the handle; (2) Padlocking each valve leading to an overboard discharge in the closed position; or (3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Overboard discharge valve for installed MSD is not secured in an approved method. 33 CFR 159.7(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Sewage overboard valve locked.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 April 2024
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Vessel was unable to produce proof of pre-employment drug testing for crewmembers onboard the vessel. 46 CFR 210(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 28 May 2024
Resolution: Pre-employment testing records for crewmembers were provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 April 2024
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers...Vessel was unable produce documentation of EAP education program, or training program for crewmembers or supervisors. Evidence of 60 minute supervisory training was unavailable for inspection, employers drug and alcohol policy not posted, crew members had not signed company drug/alcohol policy agreements, and vessel did not display informational material for EAP or contact information for Substance Abuse Professional. 46 CFR 16.401
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2024
Resolved 28 May 2024
Resolution: Supervisor was provided required training.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 April 2024
Resolved
Deck rails must be designed and constructed to withstand...a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. MI observed top deck rail forward of starboard side embarkation point is cracked on underside of weld. 46 CFR 177(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2025
Resolved 23 May 2024
Resolution: Cracked weld repaired
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 April 2024
Resolved
On a vessel...of more that 19.3 (65 feet) meters in length, the minimum capacity of the fire pump must mbe 189 liters (50 gallons) per minute...the pump outlet must be fitted wih a pressure gauge. MI observed installed gauge on the fire pump was inoperable with the pump running. 46 CFR 181.300(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 6 June 2024
Resolution: Fire pump gauge was observed functioning properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 April 2024
Resolved
You must submit your written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. The vessel did not schedule their Certificate of Inspection Renewal before the expiration date of 02APR2024. Vessel is unable to carry passengers until their inspection on 08APR2024.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2024
Resolution: Vessel completed satisfactory COI inspection.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 July 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Main deck cabin detector was missing.
46 CFR 181.405
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 July 2023
Resolution: Vessel hired technician to attend, reinstall detector, and conduct op test.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 July 2023
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel must undergo annual inspection prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2023
Resolution: Vessel completed annual.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2022
Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Unauthorized electrical connections were utilized in the Engine Room. Replace connectors with marine grade wire connectors, to the satisfaction of the Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 19 January 2023
Resolution: Electrical connectors replaced with marine grade connectors.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 8 December 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Holes in the bulkhead between Void 2 and Void 3. Make bulkheads watertight to the satisfaction of the Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 19 January 2023
Resolution: Bulkhead made watertight.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 March 2022
Resolved
Except as otherwise provided in this section, each space accessible to passengers or used by the crew on a regular basis, must have at least two means of escape. Engine room forward escape hatch was unable to be opened from inside the engine room due to a locking bolt arrangement that did not allow the securing bar to release far enough.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 March 2022
Resolved 29 March 2022
Resolution: Crew ground down extended channels that were preventing locking bar from being lowered.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 March 2022
Resolved
At each inspection for certification of a vessel, the owner shall be prepared to have the vessel ready for inspections of the hull structure. #2 and #3 voids have excessive pitting near their shared bulkhead. Provide report detailing remaining plate thickness for: #2 void - from aft bulkhead, keel up to first longitudinal stringers on either side, 3 frames forward from aft bulkhead. #3 void - from forward bulkhead, keel up to first longitudinal stringers on either side, 3 frames aft from forward bulkhead. Gauging report rcvd 29APR22, affect permanent repairs to areas ID'd over 25% at next credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 4 April 2023
Resolution: Witnessed satisfactory NDT of midbody insert.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 March 2022
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Forepeak and #3 void strainers found with multiple pinholes and require repair or replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 29 April 2022
Resolution: Received photos from owner for replaced strainers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 July 2021
Resolved
Vessel waste receptacles must be constructed of non-combustable meterial with no opening on side or bottom. MI observed plastic waste receptacles on vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 2 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI team observed 10 Adult Kapok life jackets were compromised and not in serviceable condition. Vessel restricted to carrying 143 adults until the life jackets are replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2021
Resolved 2 August 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 July 2021
Resolved
A vessel must carry an approved first aid kit. MI observed that some of the contents of the onboard first aid kit were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 2 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2021
Resolved
On a vessel of more than 65' in length, the minimum capacity of the fire pump must be 50 gpm at a pressure not less than 60 psi. During operational test of the fire pump, MI observed flow rate higher than 50 gpm from each fire hose while both were in operation, but only 45-50 psi at the fire pump outlet.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 7 September 2021
Resolution: Fire pump was replaced in kind. MI observed a flow rate of more than 50 gpm out of both fire hoses and 75 psi at the outlet of the pump.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 July 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers and crew from electrical hazards. MI observed lens on flourescent fixtures in engine room is broken.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 2 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Type approval equipment
Issued 2 July 2020
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. MI noted the FCC technician did not verify the installed EPIRB as per the FCC Safety Radiotelephony Certificate.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 16 July 2020
Resolution: Provided documentation that the EPIRB had been serviced in accoradance with the FCC on board, the technician forgot to mark the box for the EPIRB.
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 2 July 2020
Resolved
The vessel must have on board a properly installed, operational Coast Guard type-approved AIS Class B device. Vessel did not have the proper AIS unit installed.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2020
Resolved 2 August 2020
Resolution: Vessel has operational AIS-B.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 July 2020
Resolved
Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation. MI observed a 12 inch by 6 inch cutout in the overhead above the starboard engine with no insulation covering the cutout.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 16 July 2020
Resolution: Used flame resistant insulation that is suggested for use in engine rooms and covered hole.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 July 2020
Resolved
Vessel waste receptacles must be constructed of noncombustible material with no openings on side or bottom. MI observed plastic waste receptacles on vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 16 July 2020
Resolution: vessel removed bubber trash cans and replaced with metal.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 2 July 2020
Resolved
Each hatch exposed to the weather must be watertight. MI observed the hatch on port side deck level leading to the aft steering compartment had a worn gasket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 16 July 2020
Resolution: put on new rubber gasket on hatch
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 July 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI team observed 19 Adult Kapok life jackets and 2 child life jackets were compromised and not in serviceable condition. Vessel restricted to carrying 134 adults and 14 children until the life jackets are replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 July 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 July 2020
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. The vessel's alcohol testing equipment was found expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 16 July 2020
Resolution: Replaced old testing kits with new ones according to requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 July 2020
Resolved
Each survival craft on a vessel must be inspected monthly, using the manufacturer’s instructions to make sure it is complete and in good order. Vessel does not have proof of required monthly/annual life saving inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2020
Resolved 2 August 2020
Resolution: Vessel sent photos of logs.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 2 July 2020
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI observed cable run through bulkhead stbd side fwd of engine compartment was not watertight.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 2 July 2020
Resolved 2 July 2020
Resolution: Added compound to to make water-tight bulkhead.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 April 2019
Resolved
At each annual inspection, the owner, managing operator, or a qualified servicing facility shall conduct the following inspections and tests: for portable fire extinguishers, the inspections, maintenance procedures, and hydrostatic pressure test required by Chapter 4 of NFPA 10. Portable fire extinguishers require annual servicing; annual service is overdue having been last completed in February 2017. Vessel prohibited from carrying passenger for hire until annual servicing is completed. 46CFR176.810(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2019
Resolution: Fire extinguishers were service by a qualified servicing agent.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019
Resolved
A vessel must be provided with a main steering gear that is: of adequate strength and capable of steering the vessel at all service speeds and designed to operate at maximum astern speed without being damaged or jammed. Vessel has twin rudders; connections at the hydraulic ram pins are wallowed out and ball joints connecting to the rudder stock are loose. Loose connections make the system unreliable and cause undue stress to system components; system is not fit for service. Vessel is prohibited from carrying passengers for hire until repairs are completed and satisfactory operational tests are observed by the attending MI. 46CFR182.200
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2019
Resolved 11 April 2019
Resolution: Witness repair. Verified proper operation of steering gear.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 April 2019
Resolved
A vessel must comply with applicable requiremetns for any radio and electronic position indicating beacon, including the requirements for a station license and isntallation certificates to be issued by the FCC as set forth in 47 CFR part 80. Call Sign doesn't match current FCC Vessel Radio Station (BtB and Communication Safety Act) certificates. Update certificates.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 8 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 April 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts to make safe navigation possible. Charts are outdated and have no corrections, update or replace with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 11 April 2019
Resolution: Updated NAV charts aboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 April 2019
Resolved
A vessel over 65 feet must carry a minimum of three life buoys not less than 24 inches in diameter. Vessel carries three life buoys that are worn and need replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 10 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 April 2019
Resolved
Mechanically propelled T-L (over 65') vessels shall comply with the provisions of subchapter F of this chapter. Nonmetallic flexible hose must be in accordance with SAE J1942 (46 CFR 56.60-25(b) Nonmetallic materials). Vessel is utilizing nonmetallic hoses with hose clamps on entire MDE salt water cooling system. Install acceptable cooling system arrangement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 10 September 2019
Resolution: Existing hoses approved by CID.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2019
Resolved
Wiring methods and materials 50V or more. Wiring and cables shall be suitable for the particular installation and an addition, all wiring shall be run as high as practicable above the bilges. Single cable runs may be supported by metal clips screwed directly to deck or bulkhead. Supports shall be spaced no more than 18" vertical and 14" horizontal. Metal supports shall be designed to secure cable without damage to insulation or armor and bear length of at least 1/2" of cable. Bilge pump wire run through bilge alongside MDE and to the overhead, not properly installed. Make acceptable.[Applicability to existing vessels] 46 CFR 183.10-20(d) 46 CFR 111.60-25(b).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 9 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 April 2019
Resolved
Suitable covers or guards shall be installed in way of all exposed and hazardous places. Sight Glass for hydraulic fluid does not have adequate protection from breakage.Install sight glass guard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 April 2019
Resolved 16 April 2019
Resolution: Sight glass guard was installled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2019
Resolved
All vessels shall be provided a satisfactory arrangement for draining any water tight compartment. Bilge piping system has rubber hoses installed in the system with hose clamps. Replace with material IAW 46 CFR 56.60-1.[existing: 46 CFR 182.25-1]
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 8 May 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 April 2019
Resolved
An existing vessel must comply with the bilge high level alarm requirements. High Water Alarm in fwd engine room is in bilge and broken free from its plastic mounts and needs to be properly installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 16 April 2019
Resolution: Bilge alarm was properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019
Resolved
Wiring, where subject to mechanical damage shall be protected IAW NED article 346 for conduit. Wiring joints and splices shall be mechanically secure and made in junction boxes. Wire to directional control valve for bow thruster is not properly secured in housing, causing chaffing. Wiring needs to be properly secured.[46 CFR 183.05-50(2)(b)]
Action required: 703 - Prior to bunkering operations
Due 3 May 2019
Resolved 16 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 April 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date tide tables to make safe navigation possible. Tide tables are missing. Replace tide tables.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 11 April 2019
Resolution: Verified updated Tide Tables onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 2 April 2019
Resolved
Rails on passenger decks of a ferry or a vessel engaged in excursion trips, including but not limited to sightseeing-trips, dinner and party cruises, and overnight cruises, must be at least 39.5 inches. On passenger decks of a excursion vessel the following must be installed: Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter; or
Bars, slats, rail courses, or an equivalent spaced at
intervals of not more than 4 inches. Install appropriate railing.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 10 September 2019
Resolution: Existing deck rail heights approved by CID.
Construction/Loadline › Hull › Weld
Issued 13 February 2018
Resolved
V-out and weld cracks marked throughout void spaces. 46CFR176.802
Due 13 March 2018
Resolved 28 February 2018
Resolution: Inspected all welds.
Engineering › Bilge Water Management System › Piping
Issued 13 February 2018
Resolved
Provide repair proposal for bilge piping going overboard. 46CFR182.510b
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2018
Resolution: Conducted satisfactory test of bilge pump and observed piping to be in satisfactory condition.
Engineering › Bilge Water Management System › Piping
Issued 13 February 2018
Resolved
Repair overboard bilge piping prior to carrying passengers. 46CFR182.510b
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2018
Resolution: Conducted satisfactory test of bilge pump and observed piping to be in satisfactory condition.
Engineering › Generator (propulsion/auxiliary-electric) › Junction Box
Issued 13 February 2018
Resolved
Provide repair proposal for generator exhaust piping in lazarette. 46CFR182.430
Due 27 February 2018
Resolved 28 February 2018
Resolution: Observed generator exhausts to be repaired with schedule 80 piping.
Construction/Loadline › Structures › End Bulkhead
Issued 29 January 2018
Resolved
Vessel suffered damage to the stern deck and rail of the vessel as a result of an allision.
46 CFR 177.100
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 13 February 2018
Resolution: Observed weld repairs.
Construction/Loadline › Structures › Deck Plating
Issued 14 December 2016
Resolved
Make permanent repairs on bottom plate fracture. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2016
Resolved 22 December 2016
Resolution: Vessel croped and renewed area of concern. Inserted new bottom plating.
Construction/Loadline › Structures › Machinery Space Opening
Issued 14 December 2016
Resolved
Make permanent repairs for E/R overhead hole. 46CFR177.100
Condition: Improper/Lack of Maintenance
Due 12 January 2017
Resolved 22 December 2016
Resolution: Witnessed repairs to hole.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 December 2016
Resolved
Replace 01 Child-size PFD
Condition: Invalid
Due 14 December 2016
Resolved 22 December 2016
Resolution: Witnessed new child PFD onboard
Construction/Loadline › Structures › Scuttle
Issued 14 December 2016
Resolved
Repair aft cabin door coamings to ensure 6" watertight boundary or provide plan for alternative compliance. 46 CFR 179.360(d)
Condition: Design Flaw
Due 28 December 2016
Resolved 22 December 2016
Resolution: Operators welded patches on aft door coaming to meet watertight boundary.
Stability › Watertight Integrity › General
Issued 9 November 2015
Resolved
Repair or replace gasket on the emergency escape hatch from the engine room, to the satisfaction of attending Marine Inspector. “Old T” 46CFR176.25-5(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2015
Resolved 30 November 2015
Resolution: Gasket was replaced; picture provided.
Fire Fighting › Fire Pumps › Pressure
Issued 9 November 2015
Resolved
Repair or replace pressure gauge on the fire main to the satisfaction of Marine Inspector. “Old T” 46CFR181.10-1(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2015
Resolved 30 November 2015
Resolution: Gauge replaced; picture provided.
Lifesaving › Inflatable Liferafts › Capacity
Issued 9 November 2015
Resolved
Vessel is limited to 147 passengers, 2 crew, until total survival craft capacity is increased to 156 persons. 46CFR180.200
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 19 April 2016
Construction/Loadline › Hull › Weld
Issued 9 November 2015
Resolved
Five cracks in the welds in the hull structure were found in the #2 void, and 1 was found in the lazarette. Repair to the satisfaction of attending Marine Inspector at next dry dock.
**See narative for specific locations. “old T” 46CFR177.10-1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 29 April 2016
Construction/Loadline › Hull › Longitudinal Frame
Issued 21 May 2014
Resolved
For crack in deck beam overhead, port side in void #2: Provide record of the following for the material replacements conducted without USCG oversight; 100% sheer wave of the weld to be conducted by certifies 3rd party tech; if weld fails, appropriate repairs shall be conducted. All reports, and technicians certification, must be submitted to local OCMI and approved by qualified inspector.
Due 23 June 2014
Resolved 17 June 2014
Resolution: Re-conducted repairs IAW CG oversight.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 December 2010
Resolved
Vessel is currently past it's dry-dock due date. Do not operate vessel with passengers onboard until a dry-dock examination has been conducted by a USCG marine Inspector and to the satisfaction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2010
Resolution: Completed Credit Dry Dock.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 December 2010
Resolved
Remove SFO cable from E/R transformer and replace with marine grade cable.
Condition: Improper Installation
Due 14 January 2011
Resolved 20 January 2011
Resolution: Removed unaproved calbe and replaced with same gauge marine cable
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 14 December 2010
Resolved
Install no greater than 15 amp breaker for cabin lighting panel.
Condition: Improper Installation
Due 14 January 2011
Resolved 20 January 2011
Resolution: Replaced all breakers greater than 15amps and installed with 15amp breakers.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 December 2010
Resolved
Properly wire battery charger and port overhead lighting fixture.
Condition: Improper Installation
Due 14 January 2011
Resolved 20 January 2011
Resolution: Hard wired battery charger into existing junction box.
Electrical › Electric Generation Source (service) › Panelboard
Issued 14 December 2010
Resolved
Install amp meter for generator.
Condition: Improper Installation
Due 14 January 2011
Resolved 16 February 2011
Resolution: Installed amp gauge for installed generator.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 December 2010
Resolved
Install approved bracket for E/R B-II extinguisher.
Condition: Improper Installation
Due 14 January 2011
Resolved 11 January 2011
Resolution: Installed correct bracket.
Engineering › Bilge Water Management System › Piping
Issued 14 December 2010
Resolved
Repair bilge piping suction line to fore peak.
Condition: Improper/Lack of Maintenance
Due 14 January 2011
Resolved 20 January 2011
Resolution: Properly repaired forward bilge suction pipe and tested.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 December 2010
Resolved
Replace port generator R/W outlet hose.
Condition: Improper/Lack of Maintenance
Due 3 January 2011
Resolved 20 January 2011
Resolution: Replaced hose and tested.
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2009
Resolved
Company policy insufficient, as required by 46 CFR 16.401.
Due 7 January 2010
Resolved 17 December 2009
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2009
Resolved
Arrangements not made for post-casualty testing as required by 46 CFR 16.240.
Due 7 January 2010
Resolved 17 December 2009
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2009
Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Due 7 January 2010
Resolved 5 January 2010
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2009
Resolved
Supervisors has no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 7 January 2010
Resolved 5 January 2010
Engineering › Steering Gear System › Pin
Issued 1 December 2009
Resolved
Renew pins on steering system on both sides of linear actuator.
Action required: 705 - Other - as specified
Due 1 January 2010
Resolved 1 December 2009
Resolution: Received a picture verifying new pins were purchased and installed on the steering system for both sides of linear actuator.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 December 2008
Resolved
Properly insulate fraying wiring in bow thruster space.
Due 11 December 2008
Resolved 11 December 2008
Stability › Watertight Integrity › General
Issued 22 October 2008
Resolved
Complete credit dry dock. Vessel will be restricted from carrying passengers after 31Oct08 until credit for dry dock is given.
Action required: 705 - Other - as specified
Resolved 11 December 2008
Fire Fighting › Means of Escape › Blocked
Issued 28 November 2007
Resolved
Currently, no handle is installed on interior side of engine room emergency escape hatch, rendering it inoperable. Complete permanent repairs to engine room emergency escape hatch.
Due 29 November 2007
Resolved 28 November 2007
Resolution: Corrected on the spot.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 15 December 2005
Resolved
Prove proper operation of the fuel cut off valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2006
Resolved 15 December 2005
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 December 2005
Resolved
Renew 2 Adult PFDs.
Due 14 January 2006
Resolved 14 December 2005
Electrical › Electrical Distribution System (service) › Conductor
Issued 14 December 2005
Resolved
Renew the conductor for the electric outlet in the passenger accommodation space IVO the PFD locker.
Due 14 January 2006
Resolved 15 December 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 December 2005
Resolved
Renew the burn cream.
Due 14 January 2006
Resolved 14 December 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 December 2005
Resolved
Install a machinery guard for the port main diesel engine.
Due 14 January 2006
Resolved 15 December 2005
Electrical › Electric Generation Source (emergency) › Generator
Issued 14 December 2005
Resolved
Prove proper operation of the port generator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2006
Resolved 15 December 2005
Electrical › Lighting (service) › Switch
Issued 14 December 2005
Resolved
Renew the light switch and outlet box in void #2.
Due 14 January 2006
Resolved 15 December 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 14 December 2005
Resolved
Prove proper operation of the high level bilge alarm for the lazarette and void # 3.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2006
Resolved 15 December 2006
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 14 December 2005
Resolved
Provide a means to segregate Adult and Children PFDs in the PFD storage locker.
Due 14 January 2006
Resolved 15 December 2005
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 14 December 2005
Resolved
Properly label the correct number of Children PFDs.
Due 14 January 2006
Resolved 15 December 2005
Engineering › Fuel Oil Service System › Vent Pipe
Issued 14 December 2005
Resolved
Install a 30x30 mesh screen is for the Fuel Oil Service ventilation piping.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2006
Resolved 15 December 2005
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 14 December 2005
Resolved
Install a 30x30 mesh for the sewage tank vent piping.
Due 14 January 2006
Resolved 15 December 2005
Lifesaving › Buoyant Apparatus › Not on Board
Issued 14 December 2005
Resolved
Provide proof of installation of the (2) twenty-two passenger life float and (1) ten passenger life float IAW 46CFR180.137. Vessel is restricted to carrying 97 passengers for hire.
Due 14 January 2006
Resolved 27 December 2005
Communications › Radio Communications
Issued 21 January 2003
Resolved
Provide proof of EPIRB registration for 2003. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 21 February 2003
Resolved 3 February 2003
Resolution: Recieved fax confirmation of EPIRB registration.
Operations/Management › Drug and Alcohol Testing
Issued 21 January 2003
Resolved
Provide proof of Drug testing enrollment for 2003. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Improper/Lack of Maintenance
Due 21 February 2003
Resolved 3 February 2003
Resolution: Recieved fax confirmation of Consortium enrollment for 2003.
Documentation › Markings/Placards
Issued 21 January 2003
Resolved
Mark ladders to upper deck with maximum passenger capacity. LEGACY COMPONENT DESC: Capacity Marking
Condition: Improper/Lack of Maintenance
Due 21 February 2003
Resolved 3 February 2003
Resolution: Recieved fax confirmation of placards for maximum passenger capacity on upper deck.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 21 January 2003
Resolved
Provide proof of repairs to fixed seating legs in main cabin.
Condition: Improper/Lack of Maintenance
Due 21 February 2003
Resolved 3 February 2003
Resolution: Recieved fax confirmation of repairs to fixed seating in main cabin.
Construction/Loadline › Structures
Issued 16 September 2002
Resolved
Repair holes to deck IWO aft rail at the centerline. LEGACY COMPONENT DESC: Deck Plating
Due 31 October 2002
Resolved 1 November 2002
Engineering › Pressure Vessel
Issued 16 September 2002
Resolved
Remove unapproved air receiver beneath operating station (must be stamped with either ASME U or ASME UM)
Due 31 October 2002
Resolved 1 November 2002
Construction/Loadline › Hull
Issued 16 September 2002
Resolved
C/R sideshell IWO sideshell long #2. Inserts to be at least 18" x 18" w/ radiused corners. LEGACY COMPONENT DESC: Side Shell
Due 31 October 2002
Resolved 15 November 2002
Construction/Loadline › Hull
Issued 16 September 2002
Resolved
C/R sideshell long #2 above upper chine from bay 4 to bay 6 in compartment #3. LEGACY COMPONENT DESC: Side Shell
Due 31 October 2002
Resolved 15 November 2002
Electrical
Issued 27 February 2001
Resolved
MAKE WATERTIGHT WIRE RUN ON AFT BULKHEAD IN #2 COMPARTMENT.
Condition: Unknown
Due 27 March 2001
Resolved 22 March 2001
Accommodation/Occupational Safety
Issued 27 February 2001
Resolved
PROVIDE SUPPORT BRACKET FOR GALLEY PUBLIC ADDRESS SPEAKER.
Condition: Unknown
Due 27 March 2001
Resolved 22 March 2001
Navigation
Issued 27 February 2001
Resolved
PROVIDE PROOF OF OPERATIONS ON VESSEL PUBLIC ADDRESS SYSTEM.
Condition: Unknown
Due 27 March 2001
Resolved 22 March 2001
Electrical
Issued 27 February 2001
Resolved
PROVIDE SUPPORT FOR S/S GENERATOR PIPING IN AFT STEERING.
Condition: Unknown
Due 27 March 2001
Resolved 22 March 2001
Electrical
Issued 27 February 2001
Resolved
REPLACE HOSES AND HOSE CLAMPS ON S/S GENERATOR PIPING.
Condition: Unknown
Due 27 March 2001
Resolved 22 March 2001
Lifesaving
Issued 27 February 2001
Resolved
PROVIDE 33 LIGHTS FOR OCEANS LIFEJACKETS.
Condition: Unknown
Due 27 March 2001
Resolved 22 March 2001
Lifesaving
Issued 27 February 2001
Resolved
PROVIDE VESSEL NAME ON ALL LIFE RINGS.
Condition: Unknown
Due 27 March 2001
Resolved 22 March 2001
Navigation
Issued 27 February 2001
Resolved
REPLACE STERN LIGHT BULB.
Condition: Unknown
Due 27 March 2001
Resolved 22 March 2001
Electrical
Issued 27 February 2001
Resolved
RENEW OR REPLACE ALL INOPERATIVE LIGHTING AND MISSING FIXTURES.
Condition: Unknown
Due 27 March 2001
Resolved 22 March 2001
Lifesaving
Issued 27 February 2001
Resolved
PROVIDE BREAKING STRENGTH TAG FOR WEAK-LINK ON UPPERMOST LIFE FLOAT.
Condition: Unknown
Due 27 March 2001
Resolved 22 March 2001
Electrical
Issued 27 February 2001
Resolved
REMOVE OR REPLACE LIGHTING FIXTURES IN AFT STEERING.
Condition: Unknown
Due 27 March 2001
Resolved 22 March 2001
Lifesaving
Issued 10 February 2000
Resolved
PROVIDE TWO NEW PFD WATERLIGHTS.
Condition: Unknown
Due 30 March 2000
Resolved 14 January 2002
Resolution: Owner provided 02 new PFD Water lights.
Lifesaving
Issued 10 February 2000
Resolved
REPAIR OR REPLACE PUBLIC ADRESS SYSTEM.
Condition: Unknown
Due 30 March 2000
Resolved 14 January 2002
Resolution: Operational check of PA system conducted. All Satisfactory.
Electrical
Issued 10 February 2000
Resolved
PROVIDE BLANKS FOR SWITCHBOARD AND SUITABLE DOOR FOR SAME.
Condition: Unknown
Due 30 March 2000
Resolved 14 January 2002
Resolution: Conducted inspection of switchboard, all blanks provided. All satisfactory.
Navigation
Issued 19 May 1997
Resolved
PROVIDE UPDATED CHART FROM SEA GIRT, NJ TO CAPE CHARLES, VA.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Navigation
Issued 19 May 1997
Resolved
PROVIDE UPDATED CHART FROM EASTPORT, ME TO RACE POINT, MA.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Documentation
Issued 19 May 1997
Resolved
PROVIDE PROOF OF ENROLLMENT IN CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 19 May 1997
Resolved
REPLACE LIFE FLOAT PAINTER ON LIFE FLOAT ABOVE PILOT HOUSE.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 19 May 1997
Resolved
PROPERLY MARK "DISTRESS SIGNALS" ON PYRO BOX.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Navigation
Issued 19 May 1997
Resolved
PROVIDE OP TEST OF SSB RADIO._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 19 May 1997
Resolved
MARK FIRST AID KIT WITH VESSEL'S NAME.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Construction/Loadline
Issued 19 May 1997
Resolved
PROVIDE TWO 50 GPM BILGE PUMPS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Navigation
Issued 19 May 1997
Resolved
PROVIDE REEDS NAUTICAL COMPANION.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Engineering
Issued 19 May 1997
Resolved
REPLACE FLAME IMPIGMENT BOWLS ON FUEL FILTERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Lifesaving
Issued 19 May 1997
Resolved
REPLACE RETRO TAPE ON 4 LIFERINGS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Construction/Loadline
Issued 19 May 1997
Resolved
REPAIR REACH ROD FOR FORWARD COMPARTMENT.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Fire Fighting
Issued 17 May 1996
Resolved
INSTALL PRESSURE GAUGE ON FIRE PUMP DICHARGE AND PROPERLY ATTACH FIRE HOSE TO HYDRANTS, PROVE SUFFICIENT FIRE MAIN PRESSURE TO ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Construction/Loadline
Issued 17 May 1996
Resolved
PROVE WATER TIGHTNESS OF ESCAPE SCUTTLES
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Unknown
Issued 17 May 1996
Resolved
PROVE COMPLIANCE OF ALL EMERGENCY DRILLS IAW 46CFR 185.520 AND 185.524
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Unknown
Issued 17 May 1996
Resolved
POST EMERGENCY CHECK OFF LIST
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Unknown
Issued 17 May 1996
Resolved
PROVIDE AND POST EMERGENCY BROADCAST PROCEDURES
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Lifesaving
Issued 17 May 1996
Resolved
INSTALL BELT GUARDS ON STBD ENGINE
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Unknown
Issued 17 May 1996
Resolved
PROVE COMPLIANCE OF CREW TRAINING IAW 46CFR 185.420
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Documentation
Issued 17 May 1994
Resolved
RENEW FCC RADIOTELEPHONY CERTIFICATE PRIOR TO 17JUN94._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Engineering
Issued 17 May 1994
Resolved
REPLACE BROKEN LOCKING PIN FOR STBD, PROP.
Condition: Unknown
Due 17 May 1994
Resolved 23 May 1994
Lifesaving
Issued 17 May 1994
Resolved
PROPERLY ATTACH WEAK LINK FOR THE L/F ON THE PILOT HOUSE PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Lifesaving
Issued 17 May 1994
Resolved
PROVIDE NEW RETROREFLECTIVE TAPE FOR ADULT AND CHILD PFDS PRIOR TO CARRYINGPASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Fire Fighting
Issued 17 May 1994
Resolved
PROVIDE SPANNER WRENCHES FOR FIRE STATIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Construction/Loadline
Issued 21 May 1991
Resolved
REMARK EMERGENCY ESCAPE HATCH TO ENGINE ROOM._x001C_
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Accommodation/Occupational Safety
Issued 21 May 1991
Resolved
CONNECT PLUMBING AND MAKE BOTH WASH BASINS OPERATIONAL.
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Navigation
Issued 16 October 1989
Resolved
PROVE PROPER OPERATION OF SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 16 October 1989
Resolved
PROVIDE ONE WATER LIGHT BATTERY AND PROPERLY ATTACH TO LIFE FLOAT.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Unknown
Issued 16 October 1989
Resolved
PROVIDE EMERGENCY CHECK-OFF LIST AS PER 46 CFR 185.25-5.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Accommodation/Occupational Safety
Issued 16 October 1989
Resolved
PROPERLY INSULATE EXHAUST FOR DC GENERATOR LOCATED IN ENGINE ROOM. PROVIDE SUFFICIENT INSULATION TO PREVENT EXPOSURE TO PERSONNEL.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Unknown
Issued 16 October 1989
Resolved
STENCIL EMERGENCY FUEL SHUT OFF IN VICINITY OF VALVE.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Engineering
Issued 16 October 1989
Resolved
REPAIR OIL TANK LOCATED IN ENGINE ROOM.
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Navigation
Issued 16 October 1989
Resolved
PROVIDE PROPER BULBS FOR NAVIGATION LIGHTS (MAST HEAD, PORT, STBD, STERN).
Condition: Unknown
Due 16 October 1989
Resolved 16 October 1989
Lifesaving
Issued 24 February 1988
Resolved
ATTACH SUITABLE WEAK LINK ARRANGEMENT ON 2-25 PERSON LIFEFLOATS ON UPPER DECK PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Navigation
Issued 24 February 1988
Resolved
PROVIDE CURRENT AND UP TO DATE TIDE TABLES, TIDAL CURRENT TABLES, COAST PILOT AND LIGHT LIST FOR AREA OF OPERATION.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Electrical
Issued 10 April 1987
Resolved
MAKE OPERABLE VESSEL'S AUXILIARY GENERATOR.
Condition: Unknown
Due 10 April 1987
Resolved 10 April 1987
Fire Fighting
Issued 10 April 1987
Resolved
HYDROSTATICALLY TEST THE 3 BII PORTABLE FIRE EXTINGUISHERS. (46 CFR 147.04-1(A))
Condition: Unknown
Due 10 April 1987
Resolved 10 April 1987
Construction/Loadline
Issued 1 July 1986
Resolved
INCREASE THE VESSEL'S SAFETY RAIL HEIGHT TO 42 INCHES WITH PERMANENT ALTER-ATIONS AT THE NEXT CREDIT DRYDOCK EXAMINATION.
Condition: Unknown
Due 1 July 1986
Resolved 1 July 1986
Lifesaving
Issued 3 June 1986
Resolved
PROVIDE TWO ADDITIONAL LIFE JACKETS (ADULT). TOTAL NUMBER OF PERSONS ON BOARD IS LIMITED TO 153 UNTIL PROVIDED TO SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 3 June 1986
Resolved 3 June 1986
Construction/Loadline
Issued 2 April 1986
Resolved
RENEW BROKEN HOLD DOWN FOR TANK IN LAZARETTE.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Navigation
Issued 2 April 1986
Resolved
PROVIDE CURRENT CHARTS, COAST PILOT, TIDE TABLES AND LIGHT LIST FOR OPERATING AREA.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Navigation
Issued 2 April 1986
Resolved
MAKE SSB RADIO OPERATIONAL. ROUTE IS RESTRICTED TO -20- MILES FROM HARBOR OF SAFE REFUGE UNTIL COMPLETED.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Navigation
Issued 2 April 1986
Resolved
RE-POSITION SIDELIGHTS TO BE NOT FORWARD OF MAST HEAD LIGHTS.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Navigation
Issued 2 April 1986
Resolved
REMOVE WHITE PAINT FROM PORT RUNNING LIGHT LENS.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Electrical
Issued 2 April 1986
Resolved
RECONNECT BILGE ALARM IN ENGINE ROOM.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Accommodation/Occupational Safety
Issued 2 April 1986
Resolved
REMOVE ALL OIL, RAGS AND DEBRIS FROM ENGINE ROOM BILGE.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Electrical
Issued 2 April 1986
Resolved
RENEW AFT PORT BATTERY BOX.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Accommodation/Occupational Safety
Issued 2 April 1986
Resolved
RENEW THE FOUR DETERIORATED SECTIONS OF MAIN EXHAUST PIPING AND PROPERLY INSULATE.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Accommodation/Occupational Safety
Issued 2 April 1986
Resolved
RECONNECT OVERBOARD VENT FOR SEWERAGE HOLDING TANK.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Electrical
Issued 2 April 1986
Resolved
PROVIDE POSITIVE MEANS OF SECURING BATTERIES.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Electrical
Issued 2 April 1986
Resolved
PROVIDE CHAFFING PROTECTION WHERE GENERATOR MAIN SERVICE CABLE IS IN CONTACT WITH ENGINE.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Electrical
Issued 2 April 1986
Resolved
RENEW MISSING BATTERY COVER.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Electrical
Issued 2 April 1986
Resolved
PROVIDE GLOBES FOR ENGINE ROOM LIGHTS WHERE MISSING.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Electrical
Issued 2 April 1986
Resolved
PROPERLY FASTEN WIRING TO ENGINE ROOM BILGE PUMP.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Accommodation/Occupational Safety
Issued 2 April 1986
Resolved
RE-ROUTE BILGE PUMP DISCHARGE IN THE ENGINE ROOM FROM SEWERAGE HOLDING TANK.
Condition: Unknown
Due 2 April 1986
Resolved 2 April 1986
Engineering
Issued 15 October 1985
Resolved
MAKE PERMANENT REPAIRS TO BILGE PIPING AFT OF COLLISION BULKHEAD AND FWD OF VALVE.
Condition: Unknown
Due 15 October 1985
Resolved 15 October 1985
Construction/Loadline
Issued 15 October 1985
Resolved
MAKE PERMANENT REPAIRS TO THE HOLE IN THE BULKHEAD SEPARATING #2 AND #3 COMPARTMENTS STBD SIDE OF KEEL APPROX. 3 INCHES ABOVE THE BOTTOM PLATING.
Condition: Unknown
Due 15 October 1985
Resolved 15 October 1985
Electrical
Issued 22 March 1985
Resolved
PROVIDE MECHANICAL CRIMP CONNECTORS FOR SPEAKER WIRED IN THE WHEELHOUSE.
Condition: Unknown
Due 22 March 1985
Resolved 22 March 1985
Fire Fighting
Issued 22 March 1985
Resolved
PROVIDE SERVICING FOR 2 BII FIRE EXTINGUISHERS.
Condition: Unknown
Due 22 March 1985
Resolved 22 March 1985