Records from 2002 to 2025. Most recent: inspection, 16 April 2025.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 April 2025
Resolved
Tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant materials, adequately protected from mechanical damage, and provided at the tank connections with devices that will automatically close in the event of rupture of the gauge or gauge lines. Marine inspector identified flexible PVC tubing used as sight glass for tank in engine room. 46 CFR 182.440(a)(7)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 14 June 2025
Resolution: Received photo evidence of corrective action to satisfaction of MI.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 16 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect.. persons, and the vessel from electrical hazards, including fire...and electrical shock. Marine inspector found broken and dead end wires at aft bulkhead of void 2 along overhead in way of the access hatch. Remove or provide proper wire terminations to the satisfaction of the MI. 46 CFR 183.200(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 14 June 2025
Resolution: Operator provided satisfactory photo evidence of addition of proper wire termination to dead end wires.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 April 2025
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Escape hatch from engine room on port side is not marked. 46 CFR 185.606
Action required: 705 - Other - as specified
Resolved 14 June 2025
Resolution: Operator provided satisfactory photo evidence of means of escape markings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 April 2025
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck. Identified inoperative valve on bilge penetration of collision bulkhead.
46 CFR 182.25-5(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 9 April 2025
Resolution: Verified operation of bilge valve.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to... minimize accidental personnel contact with energized parts. Identified dead end wires not secured properly.
46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 9 April 2025
Resolution: Received photos of capped wires.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 April 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. The adult and child life jackets were stowed together.
46 CFR 180.78(a)(5)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 28 April 2025
Resolution: Received photo of mesh bag for life jacket separation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 April 2025
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be … made watertight. The bulkhead penetration cables were not watertight.
46 CFR 179.320(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 9 April 2025
Resolution: Received photo of cable penetrations filled with putty.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2025
Resolved
Wiring joints and splices shall be mechanically secure and made in a junction box.
46 CFR 183.05-50(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 9 April 2025
Resolution: Received photos of secured splices.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2024
Resolved
Piping used in a vital system must be composed of ferrous materials. Marine inspector witnessed fractured piping to pilge suction line #3 in the engine, forward of the manifold due to galvanic corrosion. 46 CFR 182.700(c)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2024
Resolved 28 May 2024
Resolution: Bilge line repaired and tested satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 April 2024
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment...Marine Inspector observed bilge suction arrangement in lazarette void unable to draw suction. Additionally, forepeak suction inadequately slow, Marine Inspector observed pinhole leak in forward accommodation space bilge piping at aft bulkhead, and deteriorated weld at piping bulkhead penetration. It was also observed bilge manifold piping connections in engine room were leaking with pump running. Investigate and provide root cause of failures. Repair proposals, if necessary, should be provided to MI prior to any permanent repairs are made. 46 CFR 182.25-1(a) Old T
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2024
Resolved 23 May 2024
Resolution: Tested bilge suction in lazarette, void 2, and void 3, all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 April 2024
Resolved
An internal structural examination ... may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. MI observed areas of visible wastage on main engine exhaust piping on both engines aft of flexible wet exhaust piping connections to overboard piping. Remove flexible piping from fixed piping, clean and descale for further inspection. 46CFR176.610(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2024
Resolved 6 June 2024
Resolution: Port and starboard exhausts were repaired satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 April 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Marine Inspector identified leaks on hydraulic fluid storage tank piping and lube oil tank within engine room. MI observed melted and leaking flexible hose on port generator coolant expansion tank. 46 CFR 182.01-5(a) Old T
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2024
Resolved 23 May 2024
Resolution: Hose has been rerouted around hot piping and replaced. No leaks evident.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2024
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Vessel's unlicensed crew was unfamiliar with operation of vessels emergency systems to include operation of bilge sytem and fire pump. 46 CFR 185.420(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2024
Resolved 23 May 2024
Resolution: Crew operated bilge and fire pump satisfactorily without assistance.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 April 2024
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Conduct abandon ship and man overboard drill to the satisfaction of the attending marine inspector prior to carriage of passengers. 46 CFR 176.808(g)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2024
Resolved 6 June 2024
Resolution: MOB and fire drills were conducted satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Marine Inspector identified (45) life jackets in unservicable condition. Authorized number of passengers reduced to 91 until additional lifejackets are put into service. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Replaced all faulty lifejackets. Number of lifejackets onboard is in excess of required amount on COI
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2024
Resolved
Each life jacket must be marked with Type I retroreflective material. Marine Inspector identified deteriorated retroreflective material on (14) life jackets. 46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Retroreflective material replaced on faded lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2024
Resolved
At least one ring life buoy must be fitted with a lifeline...Each lifeline on a ring life buoy must: (1) Be buoyant; (2) Be of at least 18.3 meters (60 feet) in length; (3) Be non-kinking; (4) Have a diameter of at least 7.9 millimeters (5/16 inch); (5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and (6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Required lifeline was observed to be insufficient length and a light color synthetic type. 46 CFR 180.70(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 28 May 2024
Resolution: Proper lifeline provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 April 2024
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens...MI observed faded inboard screens on port and starboard and improperly installed bulb on starboard side. 33 CFR 84.04(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Inboard screens repainted matte black and bulb replaced
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 April 2024
Resolved
Electrical equipment used in the following locations must be dripproof: (1) A machinery space. Electrical outlet on forward bulkhead of machinery space used for the multi-stage battery charger is missing dripproof covering. 46 CFR 183.210(a)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Cover installed on charger.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 April 2024
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10...The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector.. Vessel was unable to provide of portable fire extinguishing equipment servicing report.46 CFR 176.810(b)(iv)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 28 May 2024
Resolution: Vessel provided satisfactory evidence of fire servicing.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 8 April 2024
Resolved
A vessel equipped with pilothouse control must have a fixed means of two-way communications from the operating station to the location where the means of controlling the propulsion machinery. MI observed a lack of effective communication between pilothouse control and crew in working areas of the vessel. 46 CFR 184.602
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2024
Resolved 23 May 2024
Resolution: Obtained handheld radios.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 April 2024
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics. Vessel drill log does not include full date of training, or description of training topics. Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics. Vessel drill log does not include full date of training, or description of training topics. 46 CFR 185.420(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Master created new logbook containing additional required information.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 8 April 2024
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. MI observed the vessel was missing emergency broadcast instructions at the radiotelephone installation. 46 CFR 184.506
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Emergency broadcast placard installed at operating station
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 April 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot. Vessel missing comprehensive Coast Pilot for area of operation. 46 CFR 184.420(a)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Current extracts of Coast Pilot printed and onboard.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 8 April 2024
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited ... the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include— (1) Closing each valve leading to an overboard discharge and removing the handle; (2) Padlocking each valve leading to an overboard discharge in the closed position; or (3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Overboard discharge valve for installed MSD is not secured in an approved method. 33 CFR 159.7(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 May 2024
Resolution: Sewage overboard valve locked.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 April 2024
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Vessel was unable to produce proof of pre-employment drug testing for crewmembers onboard the vessel. 46 CFR 210(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 28 May 2024
Resolution: Pre-employment testing records for crewmembers were provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 8 April 2024
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers...Vessel was unable produce documentation of EAP education program, or training program for crewmembers or supervisors. Evidence of 60 minute supervisory training was unavailable for inspection, employers drug and alcohol policy not posted, crew members had not signed company drug/alcohol policy agreements, and vessel did not display informational material for EAP or contact information for Substance Abuse Professional. 46 CFR 16.401
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2024
Resolved 28 May 2024
Resolution: Supervisor was provided required training.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 April 2024
Resolved
Deck rails must be designed and constructed to withstand...a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. MI observed top deck rail forward of starboard side embarkation point is cracked on underside of weld. 46 CFR 177(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2025
Resolved 23 May 2024
Resolution: Cracked weld repaired
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 April 2024
Resolved
On a vessel...of more that 19.3 (65 feet) meters in length, the minimum capacity of the fire pump must mbe 189 liters (50 gallons) per minute...the pump outlet must be fitted wih a pressure gauge. MI observed installed gauge on the fire pump was inoperable with the pump running. 46 CFR 181.300(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 6 June 2024
Resolution: Fire pump gauge was observed functioning properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 April 2024
Resolved
You must submit your written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. The vessel did not schedule their Certificate of Inspection Renewal before the expiration date of 02APR2024. Vessel is unable to carry passengers until their inspection on 08APR2024.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2024
Resolution: Vessel completed satisfactory COI inspection.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 July 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Main deck cabin detector was missing.
46 CFR 181.405
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 July 2023
Resolution: Vessel hired technician to attend, reinstall detector, and conduct op test.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 July 2023
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel must undergo annual inspection prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2023
Resolution: Vessel completed annual.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2022
Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Unauthorized electrical connections were utilized in the Engine Room. Replace connectors with marine grade wire connectors, to the satisfaction of the Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 19 January 2023
Resolution: Electrical connectors replaced with marine grade connectors.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 8 December 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Holes in the bulkhead between Void 2 and Void 3. Make bulkheads watertight to the satisfaction of the Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 19 January 2023
Resolution: Bulkhead made watertight.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 March 2022
Resolved
Except as otherwise provided in this section, each space accessible to passengers or used by the crew on a regular basis, must have at least two means of escape. Engine room forward escape hatch was unable to be opened from inside the engine room due to a locking bolt arrangement that did not allow the securing bar to release far enough.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 March 2022
Resolved 29 March 2022
Resolution: Crew ground down extended channels that were preventing locking bar from being lowered.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 March 2022
Resolved
At each inspection for certification of a vessel, the owner shall be prepared to have the vessel ready for inspections of the hull structure. #2 and #3 voids have excessive pitting near their shared bulkhead. Provide report detailing remaining plate thickness for: #2 void - from aft bulkhead, keel up to first longitudinal stringers on either side, 3 frames forward from aft bulkhead. #3 void - from forward bulkhead, keel up to first longitudinal stringers on either side, 3 frames aft from forward bulkhead. Gauging report rcvd 29APR22, affect permanent repairs to areas ID'd over 25% at next credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 4 April 2023
Resolution: Witnessed satisfactory NDT of midbody insert.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 March 2022
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Forepeak and #3 void strainers found with multiple pinholes and require repair or replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2022
Resolved 29 April 2022
Resolution: Received photos from owner for replaced strainers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 July 2021
Resolved
Vessel waste receptacles must be constructed of non-combustable meterial with no opening on side or bottom. MI observed plastic waste receptacles on vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 2 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI team observed 10 Adult Kapok life jackets were compromised and not in serviceable condition. Vessel restricted to carrying 143 adults until the life jackets are replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2021
Resolved 2 August 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 July 2021
Resolved
A vessel must carry an approved first aid kit. MI observed that some of the contents of the onboard first aid kit were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 2 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2021
Resolved
On a vessel of more than 65' in length, the minimum capacity of the fire pump must be 50 gpm at a pressure not less than 60 psi. During operational test of the fire pump, MI observed flow rate higher than 50 gpm from each fire hose while both were in operation, but only 45-50 psi at the fire pump outlet.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 7 September 2021
Resolution: Fire pump was replaced in kind. MI observed a flow rate of more than 50 gpm out of both fire hoses and 75 psi at the outlet of the pump.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 July 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers and crew from electrical hazards. MI observed lens on flourescent fixtures in engine room is broken.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 2 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Type approval equipment
Issued 2 July 2020
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. MI noted the FCC technician did not verify the installed EPIRB as per the FCC Safety Radiotelephony Certificate.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 16 July 2020
Resolution: Provided documentation that the EPIRB had been serviced in accoradance with the FCC on board, the technician forgot to mark the box for the EPIRB.
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 2 July 2020
Resolved
The vessel must have on board a properly installed, operational Coast Guard type-approved AIS Class B device. Vessel did not have the proper AIS unit installed.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2020
Resolved 2 August 2020
Resolution: Vessel has operational AIS-B.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 July 2020
Resolved
Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation. MI observed a 12 inch by 6 inch cutout in the overhead above the starboard engine with no insulation covering the cutout.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 16 July 2020
Resolution: Used flame resistant insulation that is suggested for use in engine rooms and covered hole.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 July 2020
Resolved
Vessel waste receptacles must be constructed of noncombustible material with no openings on side or bottom. MI observed plastic waste receptacles on vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 16 July 2020
Resolution: vessel removed bubber trash cans and replaced with metal.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 2 July 2020
Resolved
Each hatch exposed to the weather must be watertight. MI observed the hatch on port side deck level leading to the aft steering compartment had a worn gasket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 16 July 2020
Resolution: put on new rubber gasket on hatch
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 July 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI team observed 19 Adult Kapok life jackets and 2 child life jackets were compromised and not in serviceable condition. Vessel restricted to carrying 134 adults and 14 children until the life jackets are replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 July 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 July 2020
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. The vessel's alcohol testing equipment was found expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 16 July 2020
Resolution: Replaced old testing kits with new ones according to requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 July 2020
Resolved
Each survival craft on a vessel must be inspected monthly, using the manufacturer’s instructions to make sure it is complete and in good order. Vessel does not have proof of required monthly/annual life saving inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2020
Resolved 2 August 2020
Resolution: Vessel sent photos of logs.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 2 July 2020
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI observed cable run through bulkhead stbd side fwd of engine compartment was not watertight.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 2 July 2020
Resolved 2 July 2020
Resolution: Added compound to to make water-tight bulkhead.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 April 2019
Resolved
At each annual inspection, the owner, managing operator, or a qualified servicing facility shall conduct the following inspections and tests: for portable fire extinguishers, the inspections, maintenance procedures, and hydrostatic pressure test required by Chapter 4 of NFPA 10. Portable fire extinguishers require annual servicing; annual service is overdue having been last completed in February 2017. Vessel prohibited from carrying passenger for hire until annual servicing is completed. 46CFR176.810(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2019
Resolution: Fire extinguishers were service by a qualified servicing agent.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019
Resolved
A vessel must be provided with a main steering gear that is: of adequate strength and capable of steering the vessel at all service speeds and designed to operate at maximum astern speed without being damaged or jammed. Vessel has twin rudders; connections at the hydraulic ram pins are wallowed out and ball joints connecting to the rudder stock are loose. Loose connections make the system unreliable and cause undue stress to system components; system is not fit for service. Vessel is prohibited from carrying passengers for hire until repairs are completed and satisfactory operational tests are observed by the attending MI. 46CFR182.200
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2019
Resolved 11 April 2019
Resolution: Witness repair. Verified proper operation of steering gear.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 2 April 2019
Resolved
A vessel must comply with applicable requiremetns for any radio and electronic position indicating beacon, including the requirements for a station license and isntallation certificates to be issued by the FCC as set forth in 47 CFR part 80. Call Sign doesn't match current FCC Vessel Radio Station (BtB and Communication Safety Act) certificates. Update certificates.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 8 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 April 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts to make safe navigation possible. Charts are outdated and have no corrections, update or replace with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 11 April 2019
Resolution: Updated NAV charts aboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 April 2019
Resolved
A vessel over 65 feet must carry a minimum of three life buoys not less than 24 inches in diameter. Vessel carries three life buoys that are worn and need replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 10 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 April 2019
Resolved
Mechanically propelled T-L (over 65') vessels shall comply with the provisions of subchapter F of this chapter. Nonmetallic flexible hose must be in accordance with SAE J1942 (46 CFR 56.60-25(b) Nonmetallic materials). Vessel is utilizing nonmetallic hoses with hose clamps on entire MDE salt water cooling system. Install acceptable cooling system arrangement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 10 September 2019
Resolution: Existing hoses approved by CID.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2019
Resolved
Wiring methods and materials 50V or more. Wiring and cables shall be suitable for the particular installation and an addition, all wiring shall be run as high as practicable above the bilges. Single cable runs may be supported by metal clips screwed directly to deck or bulkhead. Supports shall be spaced no more than 18" vertical and 14" horizontal. Metal supports shall be designed to secure cable without damage to insulation or armor and bear length of at least 1/2" of cable. Bilge pump wire run through bilge alongside MDE and to the overhead, not properly installed. Make acceptable.[Applicability to existing vessels] 46 CFR 183.10-20(d) 46 CFR 111.60-25(b).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 9 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 April 2019
Resolved
Suitable covers or guards shall be installed in way of all exposed and hazardous places. Sight Glass for hydraulic fluid does not have adequate protection from breakage.Install sight glass guard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 April 2019
Resolved 16 April 2019
Resolution: Sight glass guard was installled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2019
Resolved
All vessels shall be provided a satisfactory arrangement for draining any water tight compartment. Bilge piping system has rubber hoses installed in the system with hose clamps. Replace with material IAW 46 CFR 56.60-1.[existing: 46 CFR 182.25-1]
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 8 May 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 April 2019
Resolved
An existing vessel must comply with the bilge high level alarm requirements. High Water Alarm in fwd engine room is in bilge and broken free from its plastic mounts and needs to be properly installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 16 April 2019
Resolution: Bilge alarm was properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2019
Resolved
Wiring, where subject to mechanical damage shall be protected IAW NED article 346 for conduit. Wiring joints and splices shall be mechanically secure and made in junction boxes. Wire to directional control valve for bow thruster is not properly secured in housing, causing chaffing. Wiring needs to be properly secured.[46 CFR 183.05-50(2)(b)]
Action required: 703 - Prior to bunkering operations
Due 3 May 2019
Resolved 16 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 April 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date tide tables to make safe navigation possible. Tide tables are missing. Replace tide tables.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 11 April 2019
Resolution: Verified updated Tide Tables onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 2 April 2019
Resolved
Rails on passenger decks of a ferry or a vessel engaged in excursion trips, including but not limited to sightseeing-trips, dinner and party cruises, and overnight cruises, must be at least 39.5 inches. On passenger decks of a excursion vessel the following must be installed: Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter; or
Bars, slats, rail courses, or an equivalent spaced at
intervals of not more than 4 inches. Install appropriate railing.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 May 2019
Resolved 10 September 2019
Resolution: Existing deck rail heights approved by CID.
Construction/Loadline › Hull › Weld
Issued 13 February 2018
Resolved
V-out and weld cracks marked throughout void spaces. 46CFR176.802
Due 13 March 2018
Resolved 28 February 2018
Resolution: Inspected all welds.
Engineering › Bilge Water Management System › Piping
Issued 13 February 2018
Resolved
Provide repair proposal for bilge piping going overboard. 46CFR182.510b
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2018
Resolution: Conducted satisfactory test of bilge pump and observed piping to be in satisfactory condition.
Engineering › Bilge Water Management System › Piping
Issued 13 February 2018
Resolved
Repair overboard bilge piping prior to carrying passengers. 46CFR182.510b
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2018
Resolution: Conducted satisfactory test of bilge pump and observed piping to be in satisfactory condition.
Engineering › Generator (propulsion/auxiliary-electric) › Junction Box
Issued 13 February 2018
Resolved
Provide repair proposal for generator exhaust piping in lazarette. 46CFR182.430
Due 27 February 2018
Resolved 28 February 2018
Resolution: Observed generator exhausts to be repaired with schedule 80 piping.
Construction/Loadline › Structures › End Bulkhead
Issued 29 January 2018
Resolved
Vessel suffered damage to the stern deck and rail of the vessel as a result of an allision.
46 CFR 177.100
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 13 February 2018
Resolution: Observed weld repairs.
Construction/Loadline › Structures › Deck Plating
Issued 14 December 2016
Resolved
Make permanent repairs on bottom plate fracture. 46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2016
Resolved 22 December 2016
Resolution: Vessel croped and renewed area of concern. Inserted new bottom plating.
Construction/Loadline › Structures › Machinery Space Opening
Issued 14 December 2016
Resolved
Make permanent repairs for E/R overhead hole. 46CFR177.100
Condition: Improper/Lack of Maintenance
Due 12 January 2017
Resolved 22 December 2016
Resolution: Witnessed repairs to hole.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 December 2016
Resolved
Replace 01 Child-size PFD
Condition: Invalid
Due 14 December 2016
Resolved 22 December 2016
Resolution: Witnessed new child PFD onboard
Construction/Loadline › Structures › Scuttle
Issued 14 December 2016
Resolved
Repair aft cabin door coamings to ensure 6" watertight boundary or provide plan for alternative compliance. 46 CFR 179.360(d)
Condition: Design Flaw
Due 28 December 2016
Resolved 22 December 2016
Resolution: Operators welded patches on aft door coaming to meet watertight boundary.