Records from 2016 to 2025. Most recent: inspection, 24 April 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 24 April 2025
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. During MOB drill the rescue ladder fell into the water and sank. Acquire a new ladder as discussed with the MI and notify OCMI once complete.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2025
Resolution: MI attaned vessel to conduct def check. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 April 2025
Resolved
Each paddle required for life floats must be at least four feet in length, lashed to the life float to which it belongs and buoyant. Life float paddles are less than 4 feet and are not lashed to the life floats. Provide the appropriate number of paddles properly arranged to life floats onboard vessel.
Vessel was missing 2 life float paddles. Acquire paddles and notify local OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2025
Resolution: MI attaned vessel to conduct def check. All SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 April 2025
Resolved
A hole in the FWD bulkhead of the engine room was improperly sealed. Seal the hole to maintain gastight integrity for the fixed CO2 system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2025
Resolution: MI attaned vessel to conduct def check. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 April 2025
Resolved
Wires in the overhead of the main deck are ended with wire nuts. Either enclose these end points in a connection box or replace the wire nuts with pressure type connectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 15 July 2025
Resolution: Received photo of exposed wires with pressure type fitting attached. All SAT.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 24 April 2025
Resolved
An independent modular smoke detecting unit must:
(1) Meet UL 217 (incorporated by reference,
see 46 CFR 175.600) and be listed as a Single Station Smoke detector.
(2) Contain an independent power source; and
(3) Alarm on low power.
Vessel smoke detector in the saloon was inoperable. Replace and notify local OCMI once complete.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2025
Resolution: MI attaned vessel to conduct def check. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 April 2025
Resolved
Nautical publications must be carried as appropriate for the intended voyage, a vessel must carry adequate and up-to-date publications. MI found NAV rules book was dated in 1999. Update NAV rules publication with a more recent date and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 2 July 2025
Resolution: MI attaned vessel to conduct def check. All SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 April 2025
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessels alcohol test strips are expired. Provide valid alcohol test strips and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 2 July 2025
Resolution: MI attaned vessel to conduct def check. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines. Both remote fuel shutoffs found wedged into valve handle and not permanently connected. Install permanent connection from reach rod to valve.
46 CFR 182.455
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Permanent connections made to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2024
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Forward fuel shutoff station not marked.
46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Location of valve and direction of operation labeled to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 October 2024
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Pump outlet was not fitted with pressure gauge.
46 CFR 181.300
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Verified pump discharge outlet fitted with operable pressure gauge to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Lifejacket stowage in forward main deck cabin had child and adults stowed together with no separation.
46 CFR 180.78
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Means of separation verified to the satisfaction of the attending Marine Inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 October 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Visual indicator at operating station for #5 void was inoperable.
46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Verified proper operation of visual indicator at the operating station for Void #5.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2024
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Port forward flame screen was not 30 x 30 mesh and port aft flame screen holed. Replace both flame screens.
46 CFR 182.450
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Flame screens replaced to the satisfaction of the Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires found in overhead of main cabin above bar.
46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Dead end wires removed to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 October 2024
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Several overhead lights in the engine room not fitted with guards.
46 CFR 183.410
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Engine room lights replaced to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 October 2024
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Operating station light inoperable.
46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Operating station portable light replaced to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 October 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The First Aid Kit carried onboard had expired items and was missing items necessary to complete the kit.
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Invoice provided for First Aid Kit to the satisfaction of the attending Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 October 2024
Resolved
Each EPIRB, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. There was no log being maintained for monthly testing of the EPIRB.
46 CFR 185.728
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 October 2024
Resolution: Crew performed test and logged.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 October 2024
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. There was no log being maintained to track drills conducted by the crew.
46 CFR 185.524
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 21 October 2024
Resolution: Crew perfomred fire drill.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 October 2024
Resolved
For a vessel described by 46 CFR 175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include, but need not be limited to the topics listed in (b)(1).
46 CFR 185.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Vessel is currently under contract to be sold, and is not operating with passengers for hire.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 October 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication; Coast Guard Light List;Current tables. MI found the Coast Pilot [name withheld], and Charts were not the most up to date versions.
46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Vessel provided capability to access the publications online as a ready reference to the satisfaction of the attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 October 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI discovered the all around white light to be extinguished along with no bulb for the forward light. Vessel restricted to daytime operations only and may not operate in conditions of limited visibility such as heavy fog.
46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 January 2025
Resolution: Navigation lights verified to be operational to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 October 2023
Resolved
A vessel on an oceans route must carry six hand red flare and six hand orange smoke distress signals. Vessel missing 01 hand red flare. Procure 01 hand red flare prior to the carriage of passengers for hire.
46 CFR 180.68(a)(1)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2023
Resolution: Attended vessel, all required distress signals for route were present.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 October 2023
Resolved
A vessel must carry one floating water light unless limited to daylight operations. Vessel’s ring life buoy floating water light inoperable. Vessel is limited to daylight operations only until satisfactory operation of the water light is proven to the satisfaction of the Marine Inspector.
46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: Waterlight installed on ring life buoy witnessed operable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2023
Resolved
No marine employer shall engage or employ and individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs. Captain was not on list dated October 16, 2023. Update crew list.
46 CFR 16.210(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 8 November 2023
Resolution: [name withheld] listed on random testing crew list at time of re-inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 October 2023
Resolved
A vessel must carry a first aid kit that meets the requirements in the 46 CFR 199.175(b)(10), or equivalent. Vessel's first aid kit expired. Replace expired contents.
46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 8 November 2023
Resolution: Procured new first aid kit.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 24 October 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers and crew from electrical hazards. Dead end wire run found in CO2 storage compartment. Properly terminate exposed conductors.
46 CFR 183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 8 November 2023
Resolution: Dead end wires removed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 24 October 2023
Resolved
All electrical circuits must be clearly marked and identified. 110V panel in pilothouse found with unlabeled circuits. Identify and label circuits.
46 CFR 183.220(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 8 November 2023
Resolution: circuits labeled at time of reinspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 October 2023
Resolved
Each ring life buoy must be marked with type II retro-reflective material. 01 life buoy found with unserviceable retroreflective material. 02 life buoys in excess of requirements missing retro. Install and replace retroreflective material on 03 life buoys.
46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 8 November 2023
Resolution: All ring life buoys observed to have new solas retroreflective tape installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 October 2023
Resolved
All machinery and equipment must be maintained in such a manner as to afford adequate protection from machinery failure. Pin hole leak observed on elbow for starboard generator raw water supply. Repair to the satisfaction of Marine Inspector.
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 8 November 2023
Resolution: Raw water supply eblow replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2023
Resolved
Each life jacket carried on an oceans route must have a life jacket light approved IAW 161.012. 03 Adult PFDs and 01 Child PFD found with inoperable lights. Corrected on the spot in the presence of the attending Marine Inspector.
46 CFR 180.75
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 October 2023
Resolution: Corrected on the spot in the presence of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 24 October 2023
Resolved
For a covered vessel under 46 CFR 175.110(c), the training program must address firefighting proficiency. Drills not logged to include required training topics. Properly logged in presence of attending MI.
46 CFR 185.420(b)(1)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 24 October 2023
Resolution: Properly logged in presence of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 August 2022
Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. EPIRB is not being tested monthly or logged appropriately. EPIRB Hydrostatic release is expired and needs to be replaced. Vessel may not operate > 3 miles from shore until hydrostatic release is replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 7 September 2022
Resolution: Verified replacement of hydro.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 August 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Operational test of the means provided for pumping bilges. Bilge pump in # 4 void is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 7 September 2022
Resolution: Verified operation of bilge pump in #4 void.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 24 August 2022
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. DAPI audit revealed missing information regarding vessel’s means for randomly testing crewmembers, and did not have active employee list available from consortium.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 18 October 2022
Resolution: Added special note to conduct subsequent DAPI audit during 2023 inspection.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 August 2022
Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel did not have firefighting, abandon ship, or man overboard drills logged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 18 October 2022
Resolution: Operator stated drills have been performed.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 24 August 2022
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked. CO2 signage missing on entrance into Engine Room and #2 void.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 7 September 2022
Resolution: Verified proper signage in place.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 August 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. 2nd and 3rd steps on stairwell leading to upper deck are worn and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 7 September 2022
Resolution: Verified steps replaced.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 August 2022
Resolved
An enclosed or partially enclosed space within a vessel must be adequately ventilated in a manner suitable for the purpose of the space. Both fire dampers on main deck were wasted and unable to be closed appropriately.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 7 September 2022
Resolution: Verified both dampers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 August 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Port and starboard battery banks are leaking from top of the batteries and wood cover is breaking down on top of terminal connections leading to increased fire risk due to accumulation of kindling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 7 September 2022
Resolution: Crew modified cover to prevent wood breakdown.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 30 November 2021
Resolved
Each hatch exposed to the weather must be watertight. Both FWD and Lazarette compartments watertight hatches were found to be leaking. Hatch gaskets need to be replaced.
46 CFR 171.124 (a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2021
Resolution: All hatch gaskets have been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 November 2021
Resolved
Each inflatable buoyant apparatus must be equipped IAW manufacturer's approved servicing manual. Liferafts servicing are expired on November 30, 2021. Liferafts need to be serviced prior to operating the vessel.
46 CFR 180.175 (c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2021
Resolution: IBAs have been serviced and replaced onboard.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 November 2021
Resolved
For each marine casualty required to be reported, the owner, agent, master, or pic of the vessel shall determine whether there is any evidence of alcohol or drug use by individuals directly involved in the casualty. All alcohol strips are expired. Alcohol strips needs to be replaced.
46 CFR 185.210 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2021
Resolution: Alcohol test strips have been renewed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2021
Resolved
Each life preserver carried on a vessel must have at least 200 sq.cm (31 sq.in) of retroreflective material attached on its front side. Retroreflective material were found faded on 05 life preservers. Crew replaced faded retroreflective material, corrected on the spot.
46 CFR 180.25-25
Action required: 10 - Deficiency Rectified
Resolved 30 November 2021
Resolution: Faded retroreflective material on life preservers were replaced.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 12 November 2019
Resolved
At each subsequent inspection, the marine inspector shall conduct inspection of the interior of the hull and watertight bulkheads. Degradation of the watertight bulkhead discovered in lazzarette compartment centerline approximately one square foot extending up from the keel. Submit repair proposal and conduct repairs to satisfaction of the Marine Inspector.
46 CFR 176.25-5(a)(1) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2019
Resolved 11 December 2019
Resolution: Recieved repair proposal and pictures of repair to the satisfaction of the Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 November 2019
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. The cable penetrations in the forward bulkhead of the engine room are not vapor tight. Reseal cable penetrations to make vapor tight.
46CFR177.10-5(a) "Old T"
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2019
Resolved 11 December 2019
Resolution: Recieved pictures of satisfactory repair to the satisfaction of the Marine Inspector.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 31 August 2017
Resolved
Provide proof of a valid FCC Station License and Safety Certificate.
Condition: Improper/Lack of Maintenance
Due 7 September 2017
Resolved 4 October 2017
Resolution: Certificates obtained.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 August 2017
Resolved
Permanently install ventilation fans (electrically) to replace current arrangement using outlets.
Condition: Improper Installation
Due 30 September 2017
Resolved 4 October 2017
Resolution: Wiring was permanently corrected.
Engineering › Fuel Oil Service System › Filter
Issued 10 July 2017
Resolved
Prove proper operation of Main Diesel Engines following repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2017
Resolution: Successful dock trials conducted following repairs.
Stability › Watertight Integrity › General
Issued 3 March 2017
Resolved
Remove port and starboard vents in transom, accessible from lazarette, and make watertight. - 46 CFR 176.700(a)
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 31 May 2017
Resolution: Attending MI provided photographs of satisfactory repairs.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 March 2017
Resolved
Complete Credit Drydock. 46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2017
Resolved 10 March 2017
Resolution: Completed Dry-dock inspection.