Records from 1985 to 2025. Most recent: inspection, 24 April 2025.
Inspection history · 89
24 April 2025
Plan Review "T" Boat · Deficiency Check · COI Inspection · In-Service Inspection · Simplified Stability Test
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8126607
27 December 2024
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8051043
21 October 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8020402
24 October 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7812954
7 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608008
29 November 2022
Hull Examination · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7601705
24 August 2022
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7528880
28 December 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7373183
6 December 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7363420
30 November 2021
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7358797
5 August 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7277757
23 March 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7196138
1 March 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7148278
30 November 2020
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7102414
12 November 2019
Deficiency Check · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6853729
18 March 2019
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6644970
28 November 2018
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6587940
31 August 2017
Internal Structural Exam · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6250301
10 July 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6204751
10 July 2017
Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6211684
10 July 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6304539
12 June 2017
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6174053
31 May 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6161940
3 February 2017
Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6077997
9 November 2016
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6040508
1 September 2016
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5989955
12 November 2015
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5762497
13 December 2010
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3909949
9 December 2009
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3647419
2 October 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3330761
1 May 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3200289
12 December 2007
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3114180
24 September 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3066068
24 January 2006
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2572400
6 December 2005
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2545980
1 December 2005
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2543414
4 November 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2234602
20 November 2003
Hull Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1943240
19 November 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1708597
10 September 2002
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1656941
13 March 2002
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1488289
23 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076198
24 September 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1429627
13 February 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1058316
14 September 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1426467
16 May 2000
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1365793
15 September 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1456734
16 March 1999
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806431
24 November 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806050
17 November 1998
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806400
5 November 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1118746
23 May 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1364116
9 October 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 844493
26 September 1996
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1396605
1 April 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1078612
13 November 1995
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1184368
2 November 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 880547
1 November 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 866783
21 October 1994
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1173091
1 December 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1161583
27 September 1993
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 845611
13 April 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 828404
1 March 1993
Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1149890
9 December 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1140398
26 October 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1262741
23 September 1992
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 940660
12 August 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 651779
19 September 1991
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1245817
10 September 1991
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 935682
1 October 1990
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 932466
12 September 1990
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1226059
24 July 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1233064
19 July 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1232790
15 May 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1240206
23 April 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 913835
15 November 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1217301
30 October 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1330890
31 March 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1201426
29 September 1988
Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1194614
24 November 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1334669
30 October 1987
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1021413
8 April 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1329036
13 March 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016372
5 November 1986
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1020412
9 May 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 992592
18 March 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301712
12 November 1985
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1301612
14 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991602
24 January 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1286045
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 24 April 2025
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. During MOB drill the rescue ladder fell into the water and sank. Acquire a new ladder as discussed with the MI and notify OCMI once complete.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2025
Resolution: MI attaned vessel to conduct def check. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 April 2025
Resolved
Each paddle required for life floats must be at least four feet in length, lashed to the life float to which it belongs and buoyant. Life float paddles are less than 4 feet and are not lashed to the life floats. Provide the appropriate number of paddles properly arranged to life floats onboard vessel.
Vessel was missing 2 life float paddles. Acquire paddles and notify local OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2025
Resolution: MI attaned vessel to conduct def check. All SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 April 2025
Resolved
A hole in the FWD bulkhead of the engine room was improperly sealed. Seal the hole to maintain gastight integrity for the fixed CO2 system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2025
Resolution: MI attaned vessel to conduct def check. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 April 2025
Resolved
Wires in the overhead of the main deck are ended with wire nuts. Either enclose these end points in a connection box or replace the wire nuts with pressure type connectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 15 July 2025
Resolution: Received photo of exposed wires with pressure type fitting attached. All SAT.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 24 April 2025
Resolved
An independent modular smoke detecting unit must:
(1) Meet UL 217 (incorporated by reference,
see 46 CFR 175.600) and be listed as a Single Station Smoke detector.
(2) Contain an independent power source; and
(3) Alarm on low power.
Vessel smoke detector in the saloon was inoperable. Replace and notify local OCMI once complete.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2025
Resolution: MI attaned vessel to conduct def check. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 April 2025
Resolved
Nautical publications must be carried as appropriate for the intended voyage, a vessel must carry adequate and up-to-date publications. MI found NAV rules book was dated in 1999. Update NAV rules publication with a more recent date and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 2 July 2025
Resolution: MI attaned vessel to conduct def check. All SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 April 2025
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessels alcohol test strips are expired. Provide valid alcohol test strips and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 2 July 2025
Resolution: MI attaned vessel to conduct def check. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines. Both remote fuel shutoffs found wedged into valve handle and not permanently connected. Install permanent connection from reach rod to valve.
46 CFR 182.455
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Permanent connections made to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2024
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Forward fuel shutoff station not marked.
46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Location of valve and direction of operation labeled to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 October 2024
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Pump outlet was not fitted with pressure gauge.
46 CFR 181.300
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Verified pump discharge outlet fitted with operable pressure gauge to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 October 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Lifejacket stowage in forward main deck cabin had child and adults stowed together with no separation.
46 CFR 180.78
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Means of separation verified to the satisfaction of the attending Marine Inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 October 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Visual indicator at operating station for #5 void was inoperable.
46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Verified proper operation of visual indicator at the operating station for Void #5.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2024
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Port forward flame screen was not 30 x 30 mesh and port aft flame screen holed. Replace both flame screens.
46 CFR 182.450
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Flame screens replaced to the satisfaction of the Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires found in overhead of main cabin above bar.
46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Dead end wires removed to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 October 2024
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Several overhead lights in the engine room not fitted with guards.
46 CFR 183.410
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Engine room lights replaced to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 October 2024
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Operating station light inoperable.
46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Operating station portable light replaced to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 October 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The First Aid Kit carried onboard had expired items and was missing items necessary to complete the kit.
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Invoice provided for First Aid Kit to the satisfaction of the attending Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 October 2024
Resolved
Each EPIRB, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. There was no log being maintained for monthly testing of the EPIRB.
46 CFR 185.728
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 October 2024
Resolution: Crew performed test and logged.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 October 2024
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. There was no log being maintained to track drills conducted by the crew.
46 CFR 185.524
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 21 October 2024
Resolution: Crew perfomred fire drill.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 October 2024
Resolved
For a vessel described by 46 CFR 175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include, but need not be limited to the topics listed in (b)(1).
46 CFR 185.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Vessel is currently under contract to be sold, and is not operating with passengers for hire.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 October 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication; Coast Guard Light List;Current tables. MI found the Coast Pilot [name withheld], and Charts were not the most up to date versions.
46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2024
Resolved 28 January 2025
Resolution: Vessel provided capability to access the publications online as a ready reference to the satisfaction of the attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 October 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI discovered the all around white light to be extinguished along with no bulb for the forward light. Vessel restricted to daytime operations only and may not operate in conditions of limited visibility such as heavy fog.
46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 January 2025
Resolution: Navigation lights verified to be operational to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 October 2023
Resolved
A vessel on an oceans route must carry six hand red flare and six hand orange smoke distress signals. Vessel missing 01 hand red flare. Procure 01 hand red flare prior to the carriage of passengers for hire.
46 CFR 180.68(a)(1)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2023
Resolution: Attended vessel, all required distress signals for route were present.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 October 2023
Resolved
A vessel must carry one floating water light unless limited to daylight operations. Vessel’s ring life buoy floating water light inoperable. Vessel is limited to daylight operations only until satisfactory operation of the water light is proven to the satisfaction of the Marine Inspector.
46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 November 2023
Resolution: Waterlight installed on ring life buoy witnessed operable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2023
Resolved
No marine employer shall engage or employ and individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs. Captain was not on list dated October 16, 2023. Update crew list.
46 CFR 16.210(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 8 November 2023
Resolution: [name withheld] listed on random testing crew list at time of re-inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 October 2023
Resolved
A vessel must carry a first aid kit that meets the requirements in the 46 CFR 199.175(b)(10), or equivalent. Vessel's first aid kit expired. Replace expired contents.
46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 8 November 2023
Resolution: Procured new first aid kit.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 24 October 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers and crew from electrical hazards. Dead end wire run found in CO2 storage compartment. Properly terminate exposed conductors.
46 CFR 183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 8 November 2023
Resolution: Dead end wires removed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 24 October 2023
Resolved
All electrical circuits must be clearly marked and identified. 110V panel in pilothouse found with unlabeled circuits. Identify and label circuits.
46 CFR 183.220(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 8 November 2023
Resolution: circuits labeled at time of reinspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 October 2023
Resolved
Each ring life buoy must be marked with type II retro-reflective material. 01 life buoy found with unserviceable retroreflective material. 02 life buoys in excess of requirements missing retro. Install and replace retroreflective material on 03 life buoys.
46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 8 November 2023
Resolution: All ring life buoys observed to have new solas retroreflective tape installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 October 2023
Resolved
All machinery and equipment must be maintained in such a manner as to afford adequate protection from machinery failure. Pin hole leak observed on elbow for starboard generator raw water supply. Repair to the satisfaction of Marine Inspector.
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2023
Resolved 8 November 2023
Resolution: Raw water supply eblow replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2023
Resolved
Each life jacket carried on an oceans route must have a life jacket light approved IAW 161.012. 03 Adult PFDs and 01 Child PFD found with inoperable lights. Corrected on the spot in the presence of the attending Marine Inspector.
46 CFR 180.75
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 October 2023
Resolution: Corrected on the spot in the presence of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 24 October 2023
Resolved
For a covered vessel under 46 CFR 175.110(c), the training program must address firefighting proficiency. Drills not logged to include required training topics. Properly logged in presence of attending MI.
46 CFR 185.420(b)(1)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 24 October 2023
Resolution: Properly logged in presence of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 August 2022
Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. EPIRB is not being tested monthly or logged appropriately. EPIRB Hydrostatic release is expired and needs to be replaced. Vessel may not operate > 3 miles from shore until hydrostatic release is replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 7 September 2022
Resolution: Verified replacement of hydro.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 August 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Operational test of the means provided for pumping bilges. Bilge pump in # 4 void is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 7 September 2022
Resolution: Verified operation of bilge pump in #4 void.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 24 August 2022
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. DAPI audit revealed missing information regarding vessel’s means for randomly testing crewmembers, and did not have active employee list available from consortium.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 18 October 2022
Resolution: Added special note to conduct subsequent DAPI audit during 2023 inspection.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 August 2022
Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel did not have firefighting, abandon ship, or man overboard drills logged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 18 October 2022
Resolution: Operator stated drills have been performed.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 24 August 2022
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked. CO2 signage missing on entrance into Engine Room and #2 void.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 7 September 2022
Resolution: Verified proper signage in place.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 August 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. 2nd and 3rd steps on stairwell leading to upper deck are worn and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 7 September 2022
Resolution: Verified steps replaced.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 August 2022
Resolved
An enclosed or partially enclosed space within a vessel must be adequately ventilated in a manner suitable for the purpose of the space. Both fire dampers on main deck were wasted and unable to be closed appropriately.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 7 September 2022
Resolution: Verified both dampers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 August 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Port and starboard battery banks are leaking from top of the batteries and wood cover is breaking down on top of terminal connections leading to increased fire risk due to accumulation of kindling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 September 2022
Resolved 7 September 2022
Resolution: Crew modified cover to prevent wood breakdown.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 30 November 2021
Resolved
Each hatch exposed to the weather must be watertight. Both FWD and Lazarette compartments watertight hatches were found to be leaking. Hatch gaskets need to be replaced.
46 CFR 171.124 (a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2021
Resolution: All hatch gaskets have been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 November 2021
Resolved
Each inflatable buoyant apparatus must be equipped IAW manufacturer's approved servicing manual. Liferafts servicing are expired on November 30, 2021. Liferafts need to be serviced prior to operating the vessel.
46 CFR 180.175 (c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2021
Resolution: IBAs have been serviced and replaced onboard.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 November 2021
Resolved
For each marine casualty required to be reported, the owner, agent, master, or pic of the vessel shall determine whether there is any evidence of alcohol or drug use by individuals directly involved in the casualty. All alcohol strips are expired. Alcohol strips needs to be replaced.
46 CFR 185.210 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2021
Resolution: Alcohol test strips have been renewed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2021
Resolved
Each life preserver carried on a vessel must have at least 200 sq.cm (31 sq.in) of retroreflective material attached on its front side. Retroreflective material were found faded on 05 life preservers. Crew replaced faded retroreflective material, corrected on the spot.
46 CFR 180.25-25
Action required: 10 - Deficiency Rectified
Resolved 30 November 2021
Resolution: Faded retroreflective material on life preservers were replaced.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 12 November 2019
Resolved
At each subsequent inspection, the marine inspector shall conduct inspection of the interior of the hull and watertight bulkheads. Degradation of the watertight bulkhead discovered in lazzarette compartment centerline approximately one square foot extending up from the keel. Submit repair proposal and conduct repairs to satisfaction of the Marine Inspector.
46 CFR 176.25-5(a)(1) "Old T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2019
Resolved 11 December 2019
Resolution: Recieved repair proposal and pictures of repair to the satisfaction of the Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 November 2019
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. The cable penetrations in the forward bulkhead of the engine room are not vapor tight. Reseal cable penetrations to make vapor tight.
46CFR177.10-5(a) "Old T"
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2019
Resolved 11 December 2019
Resolution: Recieved pictures of satisfactory repair to the satisfaction of the Marine Inspector.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 31 August 2017
Resolved
Provide proof of a valid FCC Station License and Safety Certificate.
Condition: Improper/Lack of Maintenance
Due 7 September 2017
Resolved 4 October 2017
Resolution: Certificates obtained.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 August 2017
Resolved
Permanently install ventilation fans (electrically) to replace current arrangement using outlets.
Condition: Improper Installation
Due 30 September 2017
Resolved 4 October 2017
Resolution: Wiring was permanently corrected.
Engineering › Fuel Oil Service System › Filter
Issued 10 July 2017
Resolved
Prove proper operation of Main Diesel Engines following repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2017
Resolution: Successful dock trials conducted following repairs.
Stability › Watertight Integrity › General
Issued 3 March 2017
Resolved
Remove port and starboard vents in transom, accessible from lazarette, and make watertight. - 46 CFR 176.700(a)
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 31 May 2017
Resolution: Attending MI provided photographs of satisfactory repairs.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 March 2017
Resolved
Complete Credit Drydock. 46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2017
Resolved 10 March 2017
Resolution: Completed Dry-dock inspection.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 14 December 2010
Resolved
Replace portside main engine flexible hose. (8")
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 6 January 2011
Resolution: Replaced hose with new.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 December 2010
Resolved
Replace batteries on 04 waterlights for the lifefloats.
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 16 December 2010
Resolution: Vessel rep purchased new batteries from Port supply and change out the old one''s.
Communications › Radio Communications › EPIRB
Issued 14 December 2010
Resolved
Replace expire EPIRB battery and prove proper operation prior to operating more than 3NM from shore.
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 16 December 2010
Resolution: Vessel rep replaced the battery in the EPIRB.
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2009
Resolved
Company policy insufficient, as required by 46 CFR 16.401.
Due 7 January 2010
Resolved 17 December 2009
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2009
Resolved
Arrangements not made for post-casualty testing as required by 46 CFR 16.240. (Employer needs to know where collection facilities are and what hours/days they are open.)
Due 7 January 2010
Resolved 17 December 2009
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2009
Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Due 7 January 2010
Resolved 5 January 2010
Documentation › Logs/Records › Drug Test Records
Issued 9 December 2009
Resolved
Supervisors has no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 7 January 2010
Resolved 5 January 2010
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 October 2008
Resolved
Prove proper operation of 05 corroding snaps on the PFD's.
Due 2 November 2008
Resolved 2 October 2008
Resolution: Corrected on the spot.
Documentation › Markings/Placards › Lifejacket Placard
Issued 2 October 2008
Resolved
Provide Lifejacket dawning placard.
Due 2 November 2008
Resolved 2 October 2008
Resolution: Corrected on the spot.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 2 October 2008
Resolved
Provide emergency broadcast placard.
Due 2 November 2008
Resolved 2 October 2008
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 6 December 2005
Resolved
Renew 1 child's lifejacket light.
Due 6 January 2006
Resolved 6 December 2005
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 6 December 2005
Resolved
Renew 1 adult lifejacket light.
Due 6 January 2006
Resolved 6 December 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 December 2005
Resolved
Renew the lagging on the port and starboard main diesel engine exhaust.
Due 6 January 2006
Resolved 6 December 2005
Stability › Watertight Integrity › General
Issued 6 December 2005
Resolved
Cap off the old ventilation piping in the lazarette.
Due 6 January 2006
Resolved 6 December 2005
Deck/Cargo › Mooring/Anchoring › Winch
Issued 6 December 2005
Resolved
Modify the anchor windlass flexible hose runs in the forepeak void and engine room compartment to comply with 46 CFR 182.720(e)(3)(ii). Flexible nonmetallic hose must meet SAE J-1943 requirements and hose end fitting must comply with SAE J-1475 standards.
Due 1 June 2006
Resolved 27 November 2006
Resolution: Vessel removed anchor windlass.
Construction/Loadline › Hull › Keel
Issued 30 November 2005
Resolved
Gouge out to good wood, and repair with epoxy the area of the keel adjacent to the worm shoe, located approximately 12' from the stem. Area of soft wood is approximately 3" x 0.5".
Due 1 December 2005
Resolved 1 December 2005
Construction/Loadline › Hull › Bottom Plating
Issued 30 November 2005
Resolved
Gouge out to good wood, and repair with epoxy the area of the stem at the cutwater. Area of soft wood is approximately 3" x 0.5".
Due 1 December 2005
Resolved 1 December 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 4 November 2004
Resolved
Provide life saving inspection log.
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 4 November 2004
Fire Fighting › Fire Pumps › Power Source
Issued 4 November 2004
Resolved
Show proper operation of fire pump.
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 4 November 2004
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 4 November 2004
Resolved
Renew Lights on (1) child PFD and (2) adult PFDs
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 4 November 2004
Stability › Watertight Integrity
Issued 20 November 2003
Resolved
Make PVC ventilation penetrations through bulkhead (weather) deck watertight.
Due 20 December 2003
Resolved 3 December 2003
Resolution: All made watertight.
Electrical
Issued 20 November 2003
Resolved
Secure all loose wiring in #2 hold.
Due 20 November 2003
Resolved 20 November 2003
Resolution: Corrected on the spot.
Stability › Watertight Integrity
Issued 20 November 2003
Resolved
Make all penetrations thorugh watertight bulkheads watertight.
Due 20 November 2003
Resolved 20 November 2003
Resolution: All penetrations made watertight.
Construction/Loadline › Hull › Hull Plating
Issued 14 March 2002
Resolved
Submit repair proposal to fix plank in way of wood defect port side forward.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2002
Resolved 22 March 2002
Construction/Loadline › Structures
Issued 13 March 2002
Resolved
Repair rotted areas around hatches leading into forepeak & lazarette.
Due 13 May 2002
Resolved 22 March 2002
Construction/Loadline › Structures
Issued 13 March 2002
Resolved
Remove rot in frames in forepeak area. LEGACY COMPONENT DESC: Frames
Due 13 May 2002
Resolved 18 March 2002
Construction/Loadline › Structures
Issued 13 March 2002
Resolved
Seal water intrusion on deck leading into engineroom & repair rot in framing caused by intrusion. LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Due 13 May 2002
Resolved 18 March 2002
Construction/Loadline › Penetrations
Issued 13 March 2002
Resolved
Make all bulkheads watertight in way of PVC piping. LEGACY COMPONENT DESC: PVC Piping
Due 31 March 2004
Resolved 20 November 2003
Resolution: Bulkheads made watertight.
Construction/Loadline › Structures
Issued 13 March 2002
Resolved
Repair as new rotted area on port side aft on 2nd deck. LEGACY COMPONENT DESC: Superstructure
Condition: Unknown
Due 13 May 2002
Resolved 19 November 2002
Resolution: Corection vreified by [name withheld]
Operations/Management › Passenger Operations
Issued 13 March 2002
Resolved
Conduct an underway checkride in the presence of a marine inspector priot to carrying passengers-for-hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2002
Resolved 22 March 2002
Resolution: Underway checkride conducted.
Construction/Loadline › Hull › Transverse Frame
Issued 13 March 2002
Resolved
Submit repair proposal to fix delaminated frames in forepeak.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2002
Resolved 22 March 2002
Construction/Loadline
Issued 23 May 1997
Resolved
CONDUCT UNDERWAY CHECK-RIDE WITH MARINE INSPECTOR.
Condition: Unknown
Due 23 May 1997
Resolved 10 July 1997
Construction/Loadline
Issued 26 September 1996
Resolved
REPAIR CRACKED AREA OF #4 STBD SIDESHELL FRAME IN FOREPEAK (COUNTING FROM FORWARD). FRAME HAS 2-10" HORIZONTAL CRACKS THAT RUN PARALLEL ALONG THE AFT SIDE OF THE FRAME, IN THE UPPER LEVEL OF THE FOREPEAK.
Condition: Unknown
Due 1 October 1996
Resolved 11 October 1996
Construction/Loadline
Issued 26 September 1996
Resolved
AT NEXT DRYDOCK, REPAIR OR REPLACE TOP 2-3 PLANKS ALONG THE TRANSOM (WOOD IS SOFT, CRACKED IN UPPER STBD CORNER).
Condition: Unknown
Due 26 September 1996
Resolved 26 September 1996
Navigation
Issued 26 September 1996
Resolved
PROVIDE LIGHT LIST AND COAST PILOT.
Condition: Unknown
Due 1 October 1996
Resolved 11 October 1996
Lifesaving
Issued 26 September 1996
Resolved
REPLACE RINGBUOY. THIS ITEM IS TO BE COMPLETED PRIOR TO SAILING WITH PASSENGERS.
Condition: Unknown
Due 1 October 1996
Resolved 11 October 1996
Fire Fighting
Issued 26 September 1996
Resolved
PROVIDE REPORT ON HYDROTEST OF CO2 EXTINGUISHER BEFORE PUTTING BACK IN SERVICE (VSL HAS SPARE EXTINGUISHER ON BOARD).
Condition: Unknown
Due 1 October 1996
Resolved 11 October 1996
Documentation
Issued 26 September 1996
Resolved
PROVIDE AN EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 1 October 1996
Resolved 11 October 1996
Construction/Loadline
Issued 2 November 1995
Resolved
REPLACE MISSING PLANK SCREW PLUGS ON GARBOARD STRAKES PORT AND STBD 20" FORWARD OF TRANSOM.
Condition: Unknown
Due 6 November 1995
Resolved 7 November 1995
Construction/Loadline
Issued 2 November 1995
Resolved
SUBMIT WRITTEN CONFIRMATION OF BILGE EXAM BY THE MASTER FOLLOWING RETURN OFTHE VESSEL TO THE WATER.
Condition: Unknown
Due 6 November 1995
Resolved 7 November 1995
Construction/Loadline
Issued 2 November 1995
Resolved
REPAIR TRANSOM PLANKING AT ENGINE EXHAUST PORT OPENINGS PORT & STBD BY INSTALLING BACKING BLOCKS COVERING THE CIRCUMFERENCE OF EACH OPENING BEYONDTHE LOCATION OF GOOD WOOD, CUTTING AWAY ROTTED WOOD (1/4" - 1/2"), RESTORING WITH AN EPOXY BASED FILLER, AND PROPERLY REBEDDING ALL FITTINGS.
Condition: Unknown
Due 6 November 1995
Resolved 7 November 1995
Construction/Loadline
Issued 2 November 1995
Resolved
TREAT THE 3"X1" WORM DAMAGED PORTION OF WORM SHOE 8 FEET AFT OF THE STEM KNEE WITH HEAT AND CHEMICAL PRESERVATIVE. FILL AND FAIR WITH AN EPOXY BASEDCOMPOUND.
Condition: Unknown
Due 6 November 1995
Resolved 7 November 1995
Navigation
Issued 2 November 1995
Resolved
OBTAIN FCC CERTIFICATION FOR SINGLE SIDE BAND RADIO ON RADIO STATION LICENSE, VESSEL SHALL NOT OPERATE MORE THAN 20 NM FROM MAINLAND SHORE UNTILTHIS REQUIREMENT IS MET.
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Construction/Loadline
Issued 21 October 1994
Resolved
TREAT FURRING TO REINFORCEMENT BRACE AROUND MSD DISCHARGE PIPING IN #4 COMPARTMENT.
Condition: Unknown
Due 21 October 1994
Resolved 21 October 1994
Construction/Loadline
Issued 21 October 1994
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, CONDUCT AN UNDERWAY CHECK TO ENSURE THAT NO DAMAGE HAS OCCURED FROM LIFTING VESSEL IN DRYDOCK AND TO ENSURE REPAIRS MADE ARE SATISFACTORY. EACH COMPARTMENT SHALL BE ENTERED WHILE UNDERWAY.
Condition: Unknown
Due 4 November 1994
Resolved 25 October 1994
Construction/Loadline
Issued 21 October 1994
Resolved
MAKE REPAIRS TO WET ROT ON COLLISION BULKHEAD.
Condition: Unknown
Due 21 October 1994
Resolved 21 October 1994
Electrical
Issued 27 September 1993
Resolved
REPLACE HEADGASKET ON STARBOARD GENERATOR.
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993
Lifesaving
Issued 27 September 1993
Resolved
PROVIDE THREE ADULT PFD'S. VESSEL REDUCED TO 106 PASSENGERS ON LIMITED COASTWISE ROUTES.
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993
Construction/Loadline
Issued 13 April 1993
Resolved
BURN, SCRAPE & TREAT FURRING AREAS IN #1 & 4 HOLDS AND LAZARETTE.
Condition: Unknown
Due 30 April 1993
Resolved 10 May 1993
Engineering
Issued 13 April 1993
Resolved
RENEW BOTH PROPS
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Construction/Loadline
Issued 13 April 1993
Resolved
CLEAN & REMOVE GROWTH AND SEA LIFE FROM SEA COCKS/THRU HULL PENETRATIONS.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Engineering
Issued 13 April 1993
Resolved
REPLACE BOLTS ON PORT SHAFT PACKING GLAND
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Construction/Loadline
Issued 13 April 1993
Resolved
SEAL & CAULK HOLE PORT SIDE IN WAY OF PREVIOUSLY PULLED FASTINGS, CAULK OTHER AREAS OF HULL AS MARKED DURING DRY DOCK INSPECTION.
Condition: Unknown
Due 30 April 1993
Resolved 10 May 1993
Construction/Loadline
Issued 13 April 1993
Resolved
REPLACE APPROX 3.5' OF WORM SHOE STARTING AT FIRST FWD SCARF EXTENDING AFT.CHISEL, BURN, SCRAPE & EPOXY JOINT BETWEEN KEEL AND WORM SHOE PORT SIDE AFT1/3 RD OF KEEL TO REMOVE ALL WORM DAMAGE.
Condition: Unknown
Due 30 April 1993
Resolved 10 May 1993
Engineering
Issued 13 April 1993
Resolved
REPLACE ALL FOUR CUTLESS BEARINGS
Condition: Unknown
Due 30 April 1993
Resolved 10 May 1993
Fire Fighting
Issued 23 September 1992
Resolved
PROPERLY SERVICE MAIN DECK B-II EXTINGUISHER. DATE OF LAST SERVICE IS 14NOV91.
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Lifesaving
Issued 23 September 1992
Resolved
PROVIDE SEPARATE PAINTER SPOOL AND WEAK LINK FOR 12 MAN LIFEFLOAT (46 CFR 180.15-1).
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Unknown
Issued 23 September 1992
Resolved
TREAT #4 COMPT BUTT BLOCKS TO RETARD FURRING.
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Unknown
Issued 23 September 1992
Resolved
PROVIDE PROOF OF APPROVED DRUG TESTING PROGRAM.
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Accommodation/Occupational Safety
Issued 23 September 1992
Resolved
STIFFEN MIDDLE THIRD OF UPPER DECK RAILS PORT AND STBD.
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Lifesaving
Issued 23 September 1992
Resolved
FASTEN LIFEBOAT PAINTER SPOOL TO DECK.
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Construction/Loadline
Issued 23 September 1992
Resolved
INSTALL A CHECK VALVE IN EACH BRANCH OF BILGE SUCTION TO COMPLY WITH 46 CFR182-25.5(e).
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Accommodation/Occupational Safety
Issued 19 September 1991
Resolved
CHAIN AND LOCK MSD OVERBOARD DISCHARGE.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Accommodation/Occupational Safety
Issued 19 September 1991
Resolved
PROVIDE WARNING OF LOW BEAM AT AFT LADDER ON OPEN DECK.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Lifesaving
Issued 19 September 1991
Resolved
PROVIDE NEW ORANGE SMOKE AND RED HAND FLARES.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Lifesaving
Issued 19 September 1991
Resolved
PROVIDE 3 ADULT LIFE JACKETS.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Lifesaving
Issued 19 September 1991
Resolved
PROVIDE PROPER SEPARATION OF CHILDREN AND ADULT LIFE JACKETS, INCLUDING MARKINGS.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Fire Fighting
Issued 19 September 1991
Resolved
REMOVE FIRE STATION STENCIL FROM DECK WASH STATION.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Fire Fighting
Issued 10 September 1991
Resolved
REPLACE PVC PIPING LOCATED AT PORT FIREPUMP WITH STEEL PIPE
Condition: Unknown
Due 10 September 1991
Resolved 10 September 1991
Fire Fighting
Issued 12 September 1990
Resolved
IF PUMP PORT SIDE AFT TO BE USED AS FIRE PUMP IT MUST BE HARD PIPED.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990
Resolved
REATTACH ELECTRICAL WIRING TO BILGE PUMP IN FOREPEAK COMPARTMENT.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990
Resolved
PROVIDE FUEL SHUTOFF GUARDS SO THAT FUEL VALVES MAY BE OPERATED FROM OUTSIDE THE SPACE WITH OUT INJURY.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Electrical
Issued 12 September 1990
Resolved
REPLACE ALL MISSING LIGHT GLOBES IN VARIOUS AREAS OF THE VESSEL.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Accommodation/Occupational Safety
Issued 12 September 1990
Resolved
REMOVE OR PROVIDE METAL TIE DOWN STRAPS FOR THE VESSELS HOT WATER HEATER.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Accommodation/Occupational Safety
Issued 12 September 1990
Resolved
REATTACH HOT WATER HEATER CIRCULATION PUMP.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Electrical
Issued 12 September 1990
Resolved
PROVIDE COVER PLATE FOR ELECTRIC SWITCH TO HOT WATER HEATER.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990
Resolved
REPLACE SCREENS ON FUEL TANK VENTS WITH 30X30 MESH SCREEN.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Accommodation/Occupational Safety
Issued 12 September 1990
Resolved
REPLACE VENT SCREEN ON THE PORT SIDE OF THE ENGINEROOM ON FORWARD BULKHEAD.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Fire Fighting
Issued 12 September 1990
Resolved
REPAIR/REPLACE THE FIRE PUMP ON THE FORWARD BULKHEAD STARBOARD SIDE.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Fire Fighting
Issued 19 July 1990
Resolved
REPLACE/REPAIR ELECTRICAL FIRE PUMP. ONCE REPAIRED PROVIDE WITH SUITABLE HOSE WITH NOZZLE FOR DECK FIRE STATION.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Lifesaving
Issued 19 July 1990
Resolved
PROPERLY PLACARD PFD STOWAGE LOCATION ON UPPER DECK.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Engineering
Issued 23 April 1990
Resolved
EXTEND ONE ENGINE ROOM VENT TO NEAR BILGE. EXTENTION SHOULD BE MADE OF FIRE RESISTANT MATERIAL.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Construction/Loadline
Issued 23 April 1990
Resolved
INSTAL RAIL/HAND GRAB ON BOW AREA TO ELIMANATE PERSONS BEING ABLE TO HANG OVERBOARD NEAR BOW STEM.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Electrical
Issued 23 April 1990
Resolved
CLEAN UP LOOSE/FRAYING WIRES IN E/R. (NUMEROUS WIRES WERE NOT CONNECTED,)
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Accommodation/Occupational Safety
Issued 23 April 1990
Resolved
LABLE MSD O/B DISCHARGE VALVE DO NOT OPEN IN US WATERS(3NM),
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Engineering
Issued 23 April 1990
Resolved
MARK FOREPEAK BILGE CUTOFF VALVE LOCATION.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Engineering
Issued 23 April 1990
Resolved
PROPERLY SECURE GENERATOR AND OTHER FLEXIBLE HOSES FROM E/R OVERHEAD.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Engineering
Issued 23 April 1990
Resolved
PROVIDE GUARDS FOR ENGINE BELTS AND SHAFTS.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Engineering
Issued 23 April 1990
Resolved
MAKE EMERGENCY FUELSHUTOFFS ACCESSIBLE FROM OUTSIDE THE FUEL TANK SPACE.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Electrical
Issued 30 October 1989
Resolved
PROVIDE BATTERY COVERS FOR BATTERIES.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Navigation
Issued 30 October 1989
Resolved
PROVIDE CURRENT CHARTS OF AREA SAILED.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Lifesaving
Issued 30 October 1989
Resolved
REPLACE DETERIORATED EXTERIOR HANDLINES ON LIFE FLOATS. VESSEL NOT TO CARRY PASSENGERS UNTIL THIS ITEM HAS BEEN COMPLETED.
Condition: Unknown
Due 30 October 1989
Resolved 30 October 1989
Fire Fighting
Issued 30 October 1987
Resolved
HYDROSTATICALLY TEST 3 CO2 B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987
Navigation
Issued 30 October 1987
Resolved
PROVIDE TWO (2) ADDITIONAL BLACK BALL DAY SHAPES.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987
Engineering
Issued 30 October 1987
Resolved
PROVIDE A BILGE LINE STRAINER IN THE SECOND COMPARTMENT.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987
Construction/Loadline
Issued 30 October 1987
Resolved
PROVIDE CAPTIVE CHAINS OR LINES FOR THE TWO (2) WEATHER DECK HATCH COVERS.
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987