MAURY USCG vessel records
← All vessels

KARIN LYNN

Built
1974
Last inspected
2 February 2026
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 February 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK7175
Flag
UNITED STATES
Maury page id
psix-47942

Documentation record

Registered dimensions (L × B × D)55.2 ft × 19.6 ft × 6.4 ft
Registered tonnagegross 57 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGILBERT J GRISSERT · HOLDENS BEACH, NC, UNITED STATES · built 1974
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 24 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

2 February 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8280160
18 May 2025 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8124234
10 February 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8069043
5 November 2024 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8009802
16 August 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7980501
15 January 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7816755
7 June 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7706679
8 May 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675406
28 December 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7585041
10 November 2022 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7572230
31 October 2022 Drydock Extension
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7572213
8 February 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7378934
5 August 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7278418
4 March 2021 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7150614
5 February 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7136169
21 January 2021 Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7126978
24 November 2020 Hull Examination · Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7101315
12 November 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7094406
14 November 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6766450
14 November 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6543489
16 October 2018 Examination of Repairs · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6543570
13 November 2017 COI Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6286316
13 February 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6082013
18 November 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6041465

Deficiency record · 7

10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 January 2024 Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. MI observed missing compass.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2024
Resolved 12 February 2024
Resolution: Received picture with compass on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 November 2022 Resolved
ALL VESSELS SHALL BE PROVIDED WITH A SATISFACTORY ARRANGEMENT FOR DRAINING ANY WATERTIGH COMPARTMENT. MI DISCOVERED A PIN HOLE LEAK IN THE DISCHARGE PIPING OF THE PRIMARY BILGE PUMP. 46CFR182.25-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 November 2022
Resolution: O/O Replaced pipe section that had pin hole leak. Tested bilge suction; all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 November 2020 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel exceeded two year interval on 31OCT2020. Vessel required to undergo satisfactory drydock examination prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2020
Resolved 14 January 2021
Resolution: Drydock conducted
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 November 2019 Resolved
It shall be the duty of the master of any vessel to assure that all exposed hatches are properly secured before getting underway for a voyage on other than protected waters. Lazarette hatch inoperable and not watertight. Old T 46CFR185.20-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2019
Resolved 22 November 2019
Resolution: Vessel proved proper operation & water tight integrity of the Hatch for the Lazarette.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 November 2019 Resolved
Forepeak hatch cover missing attached chain.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 November 2019
Resolution: Crew attached hatch chain.
Engineering › Bilge Water Management System › Manifold
Issued 14 November 2017 Resolved
Proper label installed bilge manifold system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 14 November 2017
Resolution: Vessel properly labeled bilge manifold system.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 November 2017 Resolved
Properly secure battery box covers in engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 14 November 2017
Resolution: Vessel properly secured battery box covers.

Ownership record