Records from 1987 to 2026. Most recent: inspection, 28 April 2026.
Inspection history · 110
28 April 2026
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8332332
16 April 2026
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8351463
11 March 2026
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8324809
10 October 2025
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8249090
15 August 2025
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8182733
11 July 2025
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8162303
25 June 2025
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8161171
22 May 2025
Attraction Vessel Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8140763
16 May 2025
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8137828
1 April 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8103581
20 February 2025
Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7987749
7 November 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7987748
3 October 2024
Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8013337
28 August 2024
Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7987745
19 June 2024
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7938789
1 May 2024
Administrative Inspection · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7905695
20 March 2024
Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7881677
28 December 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7842598
9 November 2023
In-Service Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7822858
31 August 2023
Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7690889
6 June 2023
Deficiency Check · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7690586
13 April 2023
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7668364
24 March 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654604
28 December 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7613911
9 June 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7467581
26 May 2022
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7460030
28 February 2022
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7403114
12 October 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7331279
6 October 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7327965
20 June 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7234705
24 March 2021
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7162045
20 March 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7159615
20 March 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7221476
12 March 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7155246
24 February 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7148189
12 January 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7123612
6 January 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7128229
25 October 2019
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6843371
19 September 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6829998
27 August 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6826839
23 August 2019
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6790771
22 March 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6647539
11 March 2019
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6632749
10 August 2018
Administrative Inspection · Construction Oversight · Hull Examination · Damage Survey · Deficiency Check · Examination of Repairs · Internal Structural Exam · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6507433
5 May 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6105586
4 March 2017
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6099685
31 January 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6080672
17 February 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5801196
4 September 2015
Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5222809
5 June 2014
Attraction Vessel Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4880486
28 February 2012
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4231593
14 February 2011
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3945812
7 December 2010
Deficiency Check · Hull Examination · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3887439
5 March 2010
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3690462
25 February 2010
Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3686311
25 February 2010
Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3686313
25 February 2010
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3686733
8 February 2010
DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3662340
23 February 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3397670
12 November 2008
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3358004
6 November 2008
Drydock Extension
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3360103
20 August 2008
Attraction Vessel Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3306051
4 August 2008
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3288883
19 February 2008
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3134382
5 October 2007
Damage Survey · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3074039
5 June 2007
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2952572
3 May 2007
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2921632
28 March 2007
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2897264
28 February 2007
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2860729
25 October 2006
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2783899
23 January 2006
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2574878
7 February 2005
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2285571
17 December 2004
Deficiency Check · Administrative Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2261541
19 October 2004
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2177812
24 February 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2012480
20 February 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1744295
2 October 2002
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1683283
22 February 2002
Deficiency Check · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1488324
2 November 2001
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1076458
15 February 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1376721
10 October 2000
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1379213
8 September 2000
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1373179
15 February 2000
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437670
6 August 1999
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1471723
21 June 1999
Re-Inspection · Plan Review "T" Boat
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1457671
26 October 1998
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1420046
14 August 1998
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1131219
5 August 1998
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 800258
15 July 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375421
25 February 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1422813
4 February 1997
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1356085
19 September 1996
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 826089
24 May 1996
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1409515
25 May 1995
COI Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1380204
20 June 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 40486
17 May 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1170685
18 May 1993
COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 847232
19 May 1992
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1260760
16 April 1992
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 958305
20 May 1991
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 926410
20 May 1991
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1259690
13 May 1991
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 908327
13 May 1991
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1251386
12 June 1990
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 924945
31 May 1990
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1230614
30 April 1990
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 906472
6 June 1989
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1036839
4 May 1989
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1201587
9 June 1988
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 886699
23 June 1987
Initial Certification · Initial Construction-Excluding Oversight · Plan Review "T" Boat · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1309867
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 April 2025
Resolved
Remove splashguard and make available for reinspection.
Action required: 705 - Other - as specified
Resolved 16 May 2025
Resolution: All splash zone was removed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 7 November 2024
Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Two employees were not on the employee roster for pre-employment testing. 46 CFR 16.210 (a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2024
Resolved 13 November 2024
Resolution: Proof of two personnel passing the chemical test, now on list.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 7 November 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol strips were found to be out of date. 46 CFR 4.06-15 (a) (1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2024
Resolved 9 November 2024
Resolution: Alcohol strips were purchased with an expiration date of 31JUL25.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 November 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:
(1) Charts of large enough scale to make safe navigation possible;
(2) U.S. Coast Pilot or similar publication;
(3) Coast Guard Light List.
Vessel does not have up to date charts, U.S. Coast Pilot, and Coast Guard Light List. 46 CFR 184.420 (a) (1) (2)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2024
Resolved 9 November 2024
Resolution: Publications and charts are up to date and electronic.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 November 2024
Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up to date. An incorrect call sign was found on the EPIRB’s registration.
47 CFR 80.1061 (f)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2024
Resolved 31 December 2024
Resolution: EPIRB registration now has the correct call sign.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 November 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel has not logged the amount of water being pumped in their daily bilge log as required from CG-835V dated 01MAY2024. 46 CFR 177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2024
Resolved 14 November 2024
Resolution: Logs have been calculated to demonstrate how many gallons are being pumped from each space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2024
Resolved
Fill pipes and sounding pipes must be so arranged that overflow of liquid or vapor cannot escape to the inside of the vessel. A wooden plug was found to be inserted in the fill pipe. 46 CFR 182.445 (d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2024
Resolved 31 December 2024
Resolution: 1.5" diameter fuel fill pipe was installed with a fill cap at the main deck, pipe is grounded to the tank.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 November 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The ammonia ampules were found to be out of date. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2024
Resolved 9 November 2024
Resolution: Ammonia ampules were purchased with an expiration date of 30MAY29.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 May 2024
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. The OCMI may also decrease the drydock examination intervals to monitor the vessel's structural condition. Vessel is overdue for drydock examination due April 30, 2024 (one year drydock) as per issued CG-835V dated September 20, 2023. Vessel is to complete a satisfactory drydock examination prior to carrying passengers. 46 CFR 176.600 (d).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2024
Resolution: Vessel is allowed to conduct their drydock next year, due 30APR25.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 May 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection (COI) giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. The vessel must conduct the following items in addition to the current terms of their issued COI:
***Vessel must maintain a daily bilge pumping log that accurately lists all the spaces being pumped, along with the time and the amount of water being pumped out of the bilges.***
***Vessel must immediately report any notable changes or increases in bilge pumping schedules, as well as any increases in water ingress, to the Sector Los Angeles/ Long Beach Officer in Charge, Marine Inspection (OCMI).***
46 CFR 177.100
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 23 July 2025
Resolution: Vessel surrendered COI. A special not has been created to document the deficiency must be corrected prior to reissuance of COI.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 December 2023
Resolved
The minimum clear opening of a door or passageway used as a means of escape must not be less than 32 inches in width, however, doors or passageways used solely by crew members must have a clear opening not less than 28 inches. The sum of the width of all doors and passageways used as means of escape from a space must not be less than 0.333 inches multiplied by the number of passengers for which the space is designed. The forward and aft passenger berthing areas have door/passageway openings that are 28 inches in width. Vessel is prohibited from carrying overnight passengers or utilizing overnight accommodations until regulations or alternative compliance is met to OCMI satisfaction.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 June 2024
Resolution: IN ACCORDANCE WITH THE DON YOUNG COAST GUARD AUTHORIZATION ACT OF 2022, THIS VESSEL IS DESIGNATED AS A HISTORIC WOOD SAILING VESSEL AND IS EXEMPT FROM MEETING COAST GUARD STANDARDS FOR EGRESS FOR A PERIOD NOT MORE THAN 2 YEARS FROM 30JAN24.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 December 2023
Resolved
A means of escape which is not readily apparent to a person from both inside and outside the space must be adequately marked in accordance with § 185.606 of this chapter. The means of escape in the engine room/crew accommodation is not marked “EMERGENCY ESCAPE, KEEP CLEAR” on both sides in clearly legible letters. Vessel is prohibited from carrying overnight passengers or utilizing overnight accommodations until regulations or alternative compliance is met to OCMI satisfaction.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 June 2024
Resolution: IN ACCORDANCE WITH THE DON YOUNG COAST GUARD AUTHORIZATION ACT OF 2022, THIS VESSEL IS DESIGNATED AS A HISTORIC WOOD SAILING VESSEL AND IS EXEMPT FROM MEETING COAST GUARD STANDARDS FOR EGRESS FOR A PERIOD NOT MORE THAN 2 YEARS FROM 30JAN24.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 December 2023
Resolved
A ladder leading to a deck scuttle may not be used as a means of escape except: (1) On a vessel of not more than 65 feet in length, a vertical ladder and a deck scuttle may be used as not more than one of the means of escape from passenger accommodation space; or (2) As not more than one of the means of escape from any crew accommodation space or work space. The vessel is over 65 feet in length and the emergency escape in the aft passenger compartment consists of a vertical ladder. Vessel is prohibited from carrying overnight passengers or utilizing overnight accommodations until regulations or alternative compliance is met to OCMI satisfaction.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 June 2024
Resolution: IN ACCORDANCE WITH THE DON YOUNG COAST GUARD AUTHORIZATION ACT OF 2022, THIS VESSEL IS DESIGNATED AS A HISTORIC WOOD SAILING VESSEL AND IS EXEMPT FROM MEETING COAST GUARD STANDARDS FOR EGRESS FOR A PERIOD NOT MORE THAN 2 YEARS FROM 30JAN24.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 22 September 2023
No resolution recorded
Permission for repairs or alterations. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant OCMI. Vessel provided electrical plan to USCG MSC and Sector LALB. Complete MSC approval and any changes (vessel allowed to operate while these plans are being reviewed).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 22 September 2023
Resolved
Each space accessible to passengers or crew on a regular basis must have at least two means of escape. A dead end passageway more than 20 feet in length is prohibited. The minimum clear opening of a door or passageway used as a means of escape must not be less than 32 inches in width, however those used by crew members may be 28 inches in width. Ladders are steep ladders, stairways and stairwells having an angle of greater than 40 degrees for passenger and 50 for crew.
Vessel reconstructed the engine/generator enclosure in the galley/berth, ensure a suitable means of escape is provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2024
Resolution: IN ACCORDANCE WITH THE DON YOUNG COAST GUARD AUTHORIZATION ACT OF 2022, THIS VESSEL IS DESIGNATED AS A HISTORIC WOOD SAILING VESSEL AND IS EXEMPT FROM MEETING COAST GUARD STANDARDS FOR EGRESS
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 31 August 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. During inspection, no such arrangements were sighted on the anchor winch reduction gear. Provide plan for satisfactory protective arrangement to satisfaction of Marine Inspector, and then install. Vessel may operate with equipment dogged down, and move passengers off focscle area while operating equipment.
46 CFR 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 22 September 2023
Resolution: Reissued this day.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 August 2023
Resolved
A pre-engineered fixed gas fire extinguishing system must be in compliance with § 181.420 of this part and may only be installed in a normally unoccupied machinery space, a paint locker, or a storeroom containing with a gross volume of not more than 57 cubic meters (2,000 cubic feet). Vessel installed new pre-engineered fixed gas fire extinguishing in conjunction with repower, provide details of "fume tight" space and properly sized extinguishing system, and plan for satisfactory checks of this system. (system checked for shutdown, override, and discharge light/audible alarm on 24 AUG, space appears fume tight but is relatively large).
46 CFR 182.400(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 2 September 2023
Resolution: Vessel provided details for review.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 31 August 2023
Resolved
An inflatable liferaft must be serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures meeting the requirements of part 160, subpart 160.151, of this chapter no later than the month and year on its servicing sticker affixed under 46 CFR 160.151–57(n). Port liferaft servicing (30 pax) is expired. Stbd liferaft (50 pax) sat. Vessel may sail with 75 pax, or use loan raft for full COI complement.
46 CFR 185.730(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 11 September 2023
Resolution: Discussion with operator and like for like 30 pax raft loaner was replaced with vessels' raft.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 August 2023
Resolved
Piping, valves, and fittings in a fire main system must comply with subpart G, part 182, of this chapter. Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Number 2 fire station piping is leaking at fire main manifold.
46 CFR 181.310(b)
46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 5 September 2023
Resolution: Witnessed satisfactory operation, operator dissesembled and repaired leak on manifold.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 August 2023
Resolved
In systems greater than 50 volts. Each connection to a conductor must be made withing an enclosure. Electrical supply to fan in Captain's cabin supply is spliced (110v) and no junction box.
46 CFR 183.340(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 5 September 2023
Resolution: Operator removed spliced fan, installed 110V electric socket on bulkhead and is using a normal "plug in" portable fan.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 31 August 2023
Resolved
An interconnected detection and alarm system must: Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by to be protected by the interconnected detection and alarm system. Activation of one smoke alarm did not communicate to and activate alarm in all spaces.
46 CFR 181.450(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 5 September 2023
Resolution: Operator indicated that main control unit (of four matching units) may have been too far from the most remote, by moving main control unit to crew berthing/galley/engine room vice capt's room, all units communicated properly.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 31 August 2023
Resolved
Each fall must be renewed when necessary due to deterioration or at intervals of not more than 5 years,
whichever is earlier. Falls for rescue boat deteriorated and require replacement within 6 months.
46 CFR 185.704(b)
Action required: 705 - Other - as specified
Resolved 22 September 2023
Resolution: Reissued this day.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 31 August 2023
Resolved
The station bill must set forth the special duties and duty station of each crew member for various emergencies. Station bills posted did not reflect current duties of crew.
46 CFR 185.514(b)
Action required: 10 - Deficiency Rectified
Resolved 31 August 2023
Resolution: Vessel corrected to the satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 April 2023
Resolved
Must cap all sea intakes below the waterline that are not being used.
Action required: 705 - Other - as specified
Resolved 4 May 2023
Resolution: For Dry-Dock credit
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 March 2021
Resolved
AFTER AN EXTENSIVE 12 WEEK DRYDOCK PERIOD, SIGNIFICANT WATER INGRESS WAS OBSERVED DUE TO PLANK SHRINKING. VSL IS TO ALLOW SUFFICIENT SOAK TIME, ( 03 ) DAYS / ( 72 ) HOURS PIER SIDE TO ALLOW PLANKING MEMBERS TO SWELL AND TIGHTEN. VSL IS TO MONITOR WATER INGRESS LEVELS AND DEWATER AS NEEDED. AFTER ( 03 ) DAYS HAS PASSED, A MARINE INSPECTOR WILL CONDUCT AN INTERNAL STRUCTURAL EXAMINATION UNDERWAY/UNDER POWER TO ASCERTAIN THE VSLS WATERTIGHT INTEGRITY.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2021
Resolution: Underway checks SAT
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 March 2021
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel noticed the forepeak taking on water at approximately 50 gallons per hour while transiting under power; installed bilge system can keep up with the water intake. Vessel must discover the source of the flooding and minimize all flooding hazards to the satisfaction of the Marine Inspector prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 March 2021
Resolved 20 March 2021
Resolution: Vessel discovered a 12"x1" hole in port bulkhead; vessel enacted a temporary repair to the hole in order to safely transit to San Diego for a hull exam.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 January 2021
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date of the COI. Vessel exceeded 3 month interval on 11JUN2020. Vessel is required to complete a satisfactory annual inspection prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2021
Resolution: Completed annual inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 January 2021
Resolved
THE OWNER OR MANAGING OPERATOR SHALL MAKE A VESSEL AVAILABLE FOR DRYDOCKN EXAMINATIONS AT LEAST ONCE EVERY TWO YEARS. THE VESSEL HAS NOT COMPLETED A SATISFACTORY DRYDOCK EXAMINATION. VESSEL CANNOT CARRY PASSENGERS UNTIL SATISFACTORY EXAMINATION IS COMPLETED.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2021
Resolution: Credit Drydock given this date
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 January 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel experienced black smoke and metallic noise coming from the engine, this resulted in the engine being shutdown, further resulting in the vessel being towed back to the pier. Prior to getting underway, vessel rep must contact dispatch for notification. Vessel must prove proper operation of engine & propulsion system to Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 February 2021
Resolution: Vessel conducted underway sea-trails with Marine Inspector onboard, proved proper repairs of main engine.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 October 2019
Resolved
A watertight door was installed, by a prior owner, in the watertight bulkhead at frame 20 without approval of the cognizant [name withheld] or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The bulkhead must be restored to its original condition as approved on 19 JUNE 1987.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2019
Resolved 25 October 2019
Resolution: 25OCT2019: Received request for the installation of quick acting watertight doors in way of watertight bulkheads iwo bulkhead frame at 31' 1-5/8". CG-CVC-1 has approved the request with conditions. Approval letter attached.
//s// [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 September 2019
Resolved
Surfaces with in 3 feet of cooking appliances must have B-15 class fire boundaries. Provide fire boundary around galley stove.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2019
Resolved 21 October 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 March 2019
Resolved
Unauthorized installation of a watertight door- Provide a plan to ensure the transverse watertight bulkhead separating the forward accommodation space and the main hold complies with watertight door regulations in 46 CFR 179.330.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2019
Resolved 10 October 2019
Resolution: Superceded.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 March 2019
Resolved
Provide a proper anchor light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 21 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 March 2019
Resolved
Provide a pressure gauge on the fire pump outlet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 22 March 2019
Resolution: A pressure gauge was installed at the fire pump outlet and tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2019
Resolved
Remove all dead-end wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 22 March 2019
Resolution: A number of unused wires were removed, no other dead-end wires were identified during the DFU.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 March 2019
Resolved
Provide permanent type connectors for all batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2019
Resolved 22 March 2019
Resolution: Standard hex head nut were installed to replace the wingnuts.
09 - Working and Living Conditions › 091 - Living Conditions › Berth dimensions, etc.
Issued 11 March 2019
Resolved
Provide overnight accommodations for 11 additional passengers. Vessel restricted to 38 passenger while operating overnight.
Action required: 705 - Other - as specified
Due 12 April 2019
Resolved 22 March 2019
Resolution: Amended the vessels COI to reflect 38 overnight accommodations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 August 2018
Resolved
Repair the steering gear.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2019
Resolution: Stearing gear tested sat
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 10 August 2018
Resolved
Repair or replace the fuel tank.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 February 2019
Resolution: New fuel tank was constructed, inspected by the CG and installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 January 2017
Resolved
Conduct satisfactory hull and internal structural exam.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2019
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 28 February 2012
Resolved
Provide proper lagging for exposed pipe on dry exhaust.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 March 2012
Resolved 24 May 2012
Resolution: Installed proper lagging on exposed exhaust piping.
Sail Rigging › Running Rigging › Shackles
Issued 28 February 2012
Resolved
Replace the turnbuckle bolt for the foremast backstay port side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 May 2012
Resolved 14 June 2012
Resolution: New turnbuckle bolts attached
Sail Rigging › Running Rigging › Shackles
Issued 28 February 2012
Resolved
Replace the turnbuckle for the mizzen forestay starboard side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 May 2012
Resolved 14 June 2012
Resolution: New turnbuckle bolts attached
Sail Rigging › Running Rigging › Shackles
Issued 28 February 2012
Resolved
Replace all turnbuckle bolts with threads throughout with proper pins.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 May 2012
Resolved 14 June 2012
Resolution: New turnbuckle bolts attached
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 14 February 2011
Resolved
replace expired hydrostatic release on starboard side IBA.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 15 March 2011
Resolution: New hydrostatic release installed.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 February 2011
Resolved
Replace retro-reflective tape on seven (7) adult life jackets.
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 15 February 2011
Resolution: Retroreflective tape replaced.
Construction/Loadline › Structures › Superstructure
Issued 14 February 2011
Resolved
Provide written third party rigging survey iaw with note 13
Action required: 705 - Other - as specified
Due 14 March 2011
Resolved 8 March 2011
Resolution: Vessel Owner called office.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 December 2010
Resolved
Conduct satisfactory check ride prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2011
Resolved 10 February 2011
Engineering › Bilge Water Management System › Pump
Issued 8 February 2010
Resolved
Prove proper operation of the engine driven main bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2010
Resolved 11 March 2010
Accommodation/Occupational Safety › Ventilation › General
Issued 8 February 2010
Resolved
Provide a grease extraction hood for galley griddle as required by 46 CFR 181.400.
Action required: 705 - Other - as specified
Due 30 March 2010
Resolved 14 February 2011
Resolution: permanently disconnected galley griddle as per CG letter.
Engineering › Fuel Oil Service System › Hose
Issued 8 February 2010
Resolved
Provide metallic piping or flexible hose meeting the SAE J1942 standard for the main engine and generator fuel lines to include the main fuel line from the tank.
Action required: 705 - Other - as specified
Due 30 March 2010
Resolved 14 February 2011
Resolution: checked satisfactory
Electrical › Electric Supply System (service) › Cable
Issued 8 February 2010
Resolved
Provide a single line electrical diagram for AC and DC systems to include wire size, circuit loads, circuit protection, generator specs, distribution panels, emergency lighting, to USCG Sector LA-LB for approval.
Action required: 705 - Other - as specified
Due 11 March 2010
Resolved 11 March 2010
Resolution: Plans received and currently being reviewed in plan review.
Electrical › Mast › Lightning Ground
Issued 23 February 2009
Resolved
Vessel must re-attach ground to mizzen mast.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 March 2009
Resolved 10 March 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 February 2009
Resolved
Vessel must provide visual alarm for each space in bilge alarm system. Provide written procedure for checking each bilge space by crew until visual alarm is installed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 March 2009
Resolved 10 March 2009
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 23 February 2009
Resolved
Vessel must clean excessive oil around generator and out of the bilges around the generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2009
Resolved 10 March 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 February 2009
Resolved
Replace/Renew exposed battery cables at terminal.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 March 2009
Resolved 10 March 2009
Electrical › Electric Supply System (service) › Cable
Issued 23 February 2009
Resolved
Vessel must hard-wire or remove aquarium cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 March 2009
Resolved 10 March 2009
Engineering › Bilge Water Management System › Pump
Issued 5 October 2007
Resolved
Provide proof of proper operation of 2 independent fixed bilge pumping systems. to be completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2007
Resolved 30 October 2007
Resolution: Vessel rep demonstrated that all the bilge pumps work and that all bilge feet have screens. Both fixed bilge systems are in working order.
Construction/Loadline › Hull › Side Shell
Issued 5 October 2007
Resolved
Submit repair proposal for multiple blown out seams on the starboard side which are all 8"-12" above the waterline. To be completed prior to carrying passengers and to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2007
Resolved 30 October 2007
Resolution: Repair proposal submitted by vessel reps. Dutchmen were removed and replaced with proper repairs IAW chapter 5 of NVIC 7-95.
Construction/Loadline › Hull › Hull Plating
Issued 5 October 2007
Resolved
Remove dutchmen (2) and replace with full sized plank as per original scantlings. Submit repair proposal in writing IAW NVIC 7-95. Vessel is allowed to carry pax at dockside with temporary repairs to include installation of all planks.
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 30 October 2007
Resolution: Repair proposal submitted by vessel reps. Dutchmen were removed and replaced with proper repairs IAW chapter 5 of NVIC 7-95.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 28 February 2007
Resolved
Replace 18 pax buoyant apparatus with a life float. Passenger count is reduced to 82 pax.
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 3 May 2007
Resolution: Owner received and installed the Inflatable Buoyant Apparatus.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 28 February 2007
Resolved
Degrease stove and ensure galley is in sanitary condition.
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 28 March 2007
Resolution: Stove and grease trap were clean. General condition of the galley was satisfactory.
Lifesaving › Launching Appliances › Release Mechanism
Issued 28 February 2007
Resolved
Fix the spring clips on inflatable davit on stbd side.
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 28 March 2007
Resolution: spring clips were replaced with brand new clips.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 28 February 2007
Resolved
Renew buoyant apparatuses on board vessel.
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 28 March 2007
Resolution: Buoyant apparatuses that had minor cracking in the outer shell were repaired.
Construction/Loadline › Structures › Deck Plating
Issued 28 February 2007
Resolved
Repair through hole in deck for radar cable to ensure watertight.
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 28 March 2007
Resolution: Through hole in deck was properly caulked.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 28 February 2007
Resolved
Replace oil pollution placard and post by engine.
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 28 March 2007
Resolution: Old oil pollution placard was replaced by a new oil pollution placard.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 23 January 2006
Resolved
Repair emergency lighting to actuate automatically upon loss of power.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 24 February 2006
Resolution: Emergency lighting repaired.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 23 January 2006
Resolved
Label emergency escape hatches.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 23 January 2006
Resolution: Deficiency corrected on the spot.
Fire Fighting › Fire Hoses › Condition
Issued 23 January 2006
Resolved
Replace damaged fire hose.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 24 February 2006
Resolution: Vsl rep. renewed fire hose.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 23 January 2006
Resolved
Conduct repairs on BA; clean and paint where needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 24 February 2006
Resolution: Satisfactory repairs conducted.
Lifesaving › Rescue Boat Equipment › Paddle/Oar
Issued 23 January 2006
Resolved
Label each paddle w/ vessel name.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 23 January 2006
Resolution: Deficiency corrected.
Documentation › Markings/Placards › Lifejacket Placard
Issued 23 January 2006
Resolved
Renew life jacket placard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 24 February 2006
Resolution: Life jacket placard renewed.
Communications › Visual Communication › Red Warning Signal
Issued 23 January 2006
Resolved
Repair bilge visual alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 24 February 2006
Resolution: Bilge alarm repaired.
Electrical › Electrical Distribution System (emergency) › Metallic Enclosure/Frame
Issued 23 January 2006
Resolved
Install metal supports throughout E/R.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 23 January 2006
Resolution: Metal supports installed throughout E/R.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 23 January 2006
Resolved
Install sea rails on gallet stove.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 24 February 2006
Resolution: Sea rails installed.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 23 January 2006
Resolved
Provide cover panel for electrical breaker box in E/R.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 24 February 2006
Resolution: Cover panel installed for electrical breaker box in E/R.
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 January 2006
Resolved
Conduct general maintenance on starting batteries; corrosion build-up.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 24 February 2006
Resolution: Batteries cleaned satisfactorily.
Pollution Prevention/Response › Prevention Equipment › Designated Observation Area
Issued 23 January 2006
Resolved
Clean E/R bilge; remove oil, debris, and trash.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 24 February 2006
Resolution: E/R bilge cleaned.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 23 January 2006
Resolved
Properly mount power inverter; not properly secured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 17 February 2006
Resolution: Power inverter properly secured.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 23 January 2006
Resolved
Replace defective smoke sensor in berthing area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 23 January 2006
Resolution: Provided new sensor.
Engineering › Bilge Water Management System › Piping
Issued 23 January 2006
Resolved
Repair R/W pump leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 23 January 2006
Resolution: Repaired leak.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 23 January 2006
Resolved
Conduct proper emergency crew drills.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 24 February 2006
Resolution: Conducted satisfactory crew drills.
Engineering › Bilge Water Management System › Strainer
Issued 19 October 2004
Resolved
Install suction strainers on all bilge pump suctions.
Action required: 705 - Other - as specified
Due 3 December 2004
Resolved 10 December 2004
Engineering › Bilge Water Management System › Valve
Issued 19 October 2004
Resolved
Install stop valves at the hull on all submersible electric bilge pump discharge lines.
Due 10 December 2004
Resolved 3 January 2005
Resolution: Installed valves, sent pictures of installation.
Communications › Radio Communications
Issued 20 February 2003
Resolved
Must provide a copy of FCC Operator's Permit. LEGACY COMPONENT DESC: FCC Operator''''''''s Permit
Action required: 705 - Other - as specified
Due 15 April 2003
Resolved 23 February 2004
Resolution: Provided current FCC operator''s permit.
Communications › Radio Communications
Issued 20 February 2003
Resolved
Must provide copy of FCC Safety Certificate. LEGACY COMPONENT DESC: FCC Safety Certificate
Action required: 705 - Other - as specified
Due 15 April 2003
Resolved 23 February 2004
Resolution: Provided current FCC Safety Certificate.
Documentation › Logs/Records
Issued 20 February 2003
Resolved
Must provide DAPI information. LEGACY COMPONENT DESC: Drug Test Records
Action required: 705 - Other - as specified
Due 20 February 2003
Resolved 20 February 2003
Resolution: DAPI info provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 20 February 2003
Resolved
Must provide fixed fire fighting servicing certificate.
Action required: 705 - Other - as specified
Resolved 20 February 2003
Resolution: O/O provided fixed fire fighting servicing certificate.
Lifesaving › Rigid Liferafts
Issued 20 February 2003
Resolved
Must provide paddles for life floats. Vessel is limited to 54 passengers until corrected.
Action required: 705 - Other - as specified
Due 20 February 2003
Resolved 20 February 2003
Resolution: Paddles provided satisfactorily.
Navigation › Collision/Grounding Avoidance
Issued 20 February 2003
Resolved
Radar was in the shop for repairs due to water damage. Vessel is limited to 49 passengers until radar is repaired. LEGACY COMPONENT DESC: Radar
Action required: 705 - Other - as specified
Due 20 February 2003
Resolved 20 February 2003
Resolution: New radar installed on vessel.
Construction/Loadline › Hull
Issued 2 October 2002
Resolved
Remove rot from transom and replace to original.
Condition: Unknown
Due 16 October 2002
Resolved 29 October 2002
Construction/Loadline › Hull › Keel
Issued 2 October 2002
Resolved
Add five keel bolts to the keel under the engine.
Due 2 October 2002
Resolved 4 October 2002
Engineering › Bilge Water Management System
Issued 12 March 2002
Resolved
Missing high level alarm in forepeak compartment. LEGACY COMPONENT DESC: High Level Alarm
Due 15 March 2002
Resolved 22 March 2002
Resolution: Operator faxed receipt and stated the high level alarm was installed and operable.
Stability › Watertight Integrity
Issued 22 February 2002
Resolved
Make forepeak deck hatch watertight. LEGACY COMPONENT DESC: Deck Hatch
Due 8 March 2002
Resolved 12 March 2002
Resolution: Installed foam around the hatch edge, and lashed down to make watertight.
Engineering › Bilge Water Management System › Strainer
Issued 22 February 2002
Resolved
Attach screen or mesh to the bilge foot in the accomodation space.
Due 8 March 2002
Resolved 7 March 2002
Resolution: Attached mesh around bilge foot.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 February 2002
Resolved
Repair or replace the leaking wet exhaust hose attached to the main diesel engine. The leak is located above the muffler. LEGACY COMPONENT DESC: Piping (exhaust)
Due 8 March 2002
Resolved 12 March 2002
Resolution: Bought, installed and double-clamped a new section of flexible hose.
Engineering › Bilge Water Management System
Issued 22 February 2002
Resolved
Repair of replace the bilge high level alarm in the accomodation space. LEGACY COMPONENT DESC: High Level Alarm
Due 8 March 2002
Resolved 7 March 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 22 February 2002
Resolved
Provide proof of servicing of installed fire extinguishing system.
Due 8 March 2002
Resolved 27 February 2002
Resolution: Serviced by Executive Fire Protection. Owner incorrectly thought the company had serviced the installed system when servicing the portable fire extinguishers.
Documentation
Issued 22 February 2002
Resolved
Provide MIS data form to show compliance with drug audit program.
Due 8 March 2002
Resolved 7 March 2002
Engineering › Bilge Water Management System
Issued 22 February 2002
Resolved
Install high level alarm in after-most (captain's) cabin, and in forepeak space. LEGACY COMPONENT DESC: High Level Alarm
Due 15 March 2002
Resolved 22 March 2002
Resolution: Operator faxed receipt and stated the high level alarm was installed and operable.
Accommodation/Occupational Safety
Issued 15 February 2001
Resolved
Provide "Emergency Exit" sign in galley space.
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Fire Fighting
Issued 15 February 2001
Resolved
Provide smoke detectors in crew and passenger accomodation spaces.
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Lifesaving
Issued 15 February 2001
Resolved
Repair or replace speakers for public address system.
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Lifesaving
Issued 15 February 2001
Resolved
Provide a current hydrostatic release for EPIRB.
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Construction/Loadline
Issued 10 October 2000
Resolved
REPLACE ROTTED DECK PLANKS, STARBOARD SIDE, FORWARD OF WINDLASS.
Condition: Unknown
Due 10 October 2000
Resolved 10 October 2000
Construction/Loadline
Issued 15 February 2000
Resolved
Replace bilge pump hose in main hold.
Condition: Unknown
Due 22 February 2000
Resolved 3 March 2000
Fire Fighting
Issued 15 February 2000
Resolved
Recharge/service one B-II portable fire extinguisher, located in engine room aft and portside.
Condition: Unknown
Due 22 February 2000
Resolved 3 March 2000
Unknown
Issued 15 February 2000
Resolved
Make chemical testing program paperwork available to an attending marine inspector.
Condition: Unknown
Due 15 February 2000
Resolved 15 February 2000
Navigation
Issued 15 February 2000
Resolved
Provide a Long Beach and Los Angeles Inner Harbor chart. 46/184.420.
Condition: Unknown
Due 22 February 2000
Resolved 3 March 2000
Construction/Loadline
Issued 15 February 2000
Resolved
Provide visual means at operating station that would indicate when automatic bilge pumps, in main hold and engine room, are automatically operating. 46/182.530(c).
Condition: Unknown
Due 22 February 2000
Resolved 3 March 2000
Unknown
Issued 15 February 2000
Resolved
Secure MSD overboard discharge valve handle in way to prevent accidental discharge in prohibited areas.
Condition: Unknown
Due 22 February 2000
Resolved 3 March 2000
Construction/Loadline
Issued 21 June 1999
Resolved
Provide high-level bilge alarms as per 46 CFR 182.530.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Unknown
Issued 21 June 1999
Resolved
Provide labeling for curcuit paneling.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Fire Fighting
Issued 21 June 1999
Resolved
Provide proof of servicing of all portable fire extinguishers.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Lifesaving
Issued 21 June 1999
Resolved
Prove rescue boat meets requirements in 46 CFR.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Engineering
Issued 21 June 1999
Resolved
Prove proper operation of emergency fuel shutoff valve.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Fire Fighting
Issued 21 June 1999
Resolved
Provide an approved fixed fire extinguishing system as per vessel's approved plans and 46 CFR 181.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Electrical
Issued 26 October 1998
Resolved
Remove all oil from wiring, properly secure wire runs and ensure all connections are proper type._x001C_
Condition: Unknown
Due 26 October 1998
Resolved 26 October 1998
Fire Fighting
Issued 26 October 1998
Resolved
Renew 2ea. B-II fire extinguishers._x001C_
Condition: Unknown
Due 26 October 1998
Resolved 26 October 1998
Electrical
Issued 26 October 1998
Resolved
Clean oil from main generator breaker box and relocate box so oil will not leak into breaker._x001C_
Condition: Unknown
Due 26 October 1998
Resolved 26 October 1998
Electrical
Issued 26 October 1998
Resolved
Clean oil from both alternators._x001C_
Condition: Unknown
Due 26 October 1998
Resolved 26 October 1998
Lifesaving
Issued 15 July 1998
Resolved
PROVIDE PENDENTS & LIFELINES ON BUOYANT APPARATUS.
Condition: Unknown
Due 29 July 1998
Resolved 28 July 1998
Lifesaving
Issued 15 July 1998
Resolved
PROVIDE APPROVED FLOAT-FREE LINKS FOR BUOYANT APPARATUS.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Accommodation/Occupational Safety
Issued 15 July 1998
Resolved
PROVIDE LATCH FOR OVEN DOOR.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Construction/Loadline
Issued 4 February 1997
Resolved
Renew wasted bilge piping in engine compartment._x001C_
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Construction/Loadline
Issued 4 February 1997
Resolved
Provide repair plan and make repairs as per approved plan to the following areas: Stb side below fwd chainplate, Stb side below aft chainplate.
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Construction/Loadline
Issued 4 February 1997
Resolved
Provide proof of refastening of vessel. _x001C_
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Lifesaving
Issued 24 May 1996
Resolved
CONDUCT FIRE AND MAN OVERBOARD DRILLS PRIOR TO 30 SEP 96.
Condition: Unknown
Due 24 May 1996
Resolved 24 May 1996
Fire Fighting
Issued 17 May 1994
Resolved
PROVIDE SPANNER WRENCH FOR FIRE STATION.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Electrical
Issued 20 May 1991
Resolved
PROVIDE EMERGENCY LIGHTING FOR PASSENGER SPACES BELOW DECK AS DESCRIBED IN 46 CFR 184.30-5.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Construction/Loadline
Issued 13 May 1991
Resolved
PROPERLY REPAIR OR REPLACE RUDDER, CARRIER AND AREA SURROUNDING RUDDER POST._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Accommodation/Occupational Safety
Issued 31 May 1990
Resolved
REMOVE PAINT FROM MAIN CABIN, THIS ITEM TO BE COMPLETED PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Accommodation/Occupational Safety
Issued 31 May 1990
Resolved
PROVIDE ESCAPE HATCHES WITH MARKINGS IN ACCORDANCE WITH 46 CFR 185.30-15.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Accommodation/Occupational Safety
Issued 31 May 1990
Resolved
PROVIDE INSTRUCTIONS IN PASSENGER CABINS FOR SAFETY EQUIPMENT AND ESCAPE ROUTES FROM CABIN.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990