Records from 2005 to 2026. Most recent: inspection, 2 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 44
2 April 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8315001
15 January 2026
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8297628
9 December 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8280218
11 August 2025
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8207321
7 July 2025
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8177836
27 March 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8060349
13 May 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7883220
10 May 2024
Liferaft Servicing
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7924416
24 April 2024
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7900492
8 January 2024
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7846453
1 January 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7844062
24 March 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654608
11 March 2023
Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7649420
11 March 2023
Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654268
11 March 2023
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7655701
1 March 2023
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7639857
9 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7425419
24 March 2022
Administrative Inspection · In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7613913
6 December 2021
Internal Structural Exam · Drydock Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7363427
22 June 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7233093
21 April 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7179795
6 January 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7128229
22 May 2020
Administrative Inspection · Plan Review "T" Boat · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7049178
2 March 2020
Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6919344
2 March 2020
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7194770
10 February 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6904845
10 February 2020
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6908767
19 March 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6621642
7 November 2018
Examination of Repairs · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6576912
16 February 2018
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6353863
31 January 2018
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6336633
28 August 2017
Administrative Inspection · Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6254134
31 March 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6119981
10 March 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6103749
10 March 2017
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6106780
28 February 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6095702
6 December 2016
Construction Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6056607
3 October 2016
Administrative Inspection · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6016943
12 August 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5970952
2 August 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5960903
24 June 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5942058
17 March 2016
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5834859
12 February 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5993709
9 February 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5786581
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 April 2026
Resolved
A vessel with overnight accommodations for passengers must have an interconnected fire detection system installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas to be protected by the interconnected detection and alarm system. MI observed fire detection in the forward accommodation space was not interconnected to the fire detection in the engine room and aft accommodation space. Vessel must assign stationed fire watch-stander in the forward accommodation space while carrying overnight passengers. Interconnect all fire detection within 7 days.
Action required: 705 - Other - as specified
Due 9 April 2026
Resolved 1 May 2026
Resolution: Attended vessel and witnessed interconnected fire alarms-cleared def.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 April 2026
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. MI observed the fire pump pressure gauge reading was maintaining 40psi. Ensure fire pump maintains 60psi within 7 days.
Action required: 705 - Other - as specified
Due 9 April 2026
Resolved 1 May 2026
Resolution: Attended vessel and witness fire pump in good working order with valid pressure-cleared def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2026
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. MI observed child life jackets aft storage sign was broken. Replace sign within 14 days.
Action required: 705 - Other - as specified
Due 16 April 2026
Resolved 30 April 2026
Resolution: Recieved photo of new child lifejacket signage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 December 2025
No resolution recorded
Identify and repair 2 minor leaks from hot water heater and freshwater tank in Berth B compartment causing standing water in the space.
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 July 2025
Resolved
MI observed pictures of damage to the starboard side lower yard arm that connects to the foremast course sail. Starboard side end of yard arm's foot rope eye bolt was removed by impact and splits in the wood were noticed. Submit plans to permanently repair the yard arm to the local OCMI.
--Vessel is restricted from using the course sail until permanent repairs have been conducted.-- 46 CFR 177.330
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 4 September 2025
Resolution: Attended vessel and confirmed satisfactory repairs were made to the stbd yard arm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 March 2025
Resolved
PLASTIC MATERIALS MAY BE ONLY BE USED IN NON-VITAL SYSTEMS. MI DISCOVERED PLASTIC MATERIALS FOUND IN BILGE PIPING. BILGE SYSTEM IS CONSIDERED A VITAL SYSTEM ON THIS VESSEL.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2025
Resolved 10 April 2025
Resolution: Def cleared with acceptable materials.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 March 2025
Resolved
THE CONSTRUCTION AND ARRANGEMENT OF A VESSEL MUST ALLOW THE SAFE OPERATION OF THE VESSEL IN ACCORDANCE WITH THE TERMS OF ITS CERTIFICATE OF INSPECTION. DURING MOB DRILL UNDER AUXILIARY PROPULSION (SAIL), MI DISCOVERED A 6 INCH TEAR IN THE SQUARE SAIL, 3RD FROM THE TOP AT LOWER PORT SIDE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2025
Resolved 10 April 2025
Resolution: Operator provide proper repairs to 6 inch tear.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 27 March 2025
Resolved
EACH WINDOW, PORT HOLE, OR OTHER MEANS OF ATTACHMENT TO THE HULL OR DECK HOUSE, MUST BE CAPABLE OF WITHSTANDING THE MAXIMUM LOAD FROM WAVE AND WIND CONDITIONS EXPECTED DUE TO ITS LOCATION ON THE VESSEL AND THE AUTHORIZED ROUTE OF THE VESSEL. MI DISCOVERED MOST PORT HOLES ON VESSEL TO NOT BE WEATHERTIGHT. VESSEL GIVEN TO NEXT DRYDOCK TO RECTIFY DEFICIENCY.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2026
Resolved 9 December 2025
Resolution: MI witnessed installation
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 March 2025
Resolved
THE GENERAL CONSTRUCTION OF THE VESSEL MUST BE SUCH AS TO MINIMIZE FIRE HAZARDS. MI DISCOVERED EXCESSSIVE OIL IN ENGINE ROOM BILGE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2025
Resolved 10 April 2025
Resolution: Excessive oil cleaned up.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 March 2025
Resolved
A HATCH EXPOSED TO THE WEATHER MUST BE WATERTIGHT. MI DISCOVERED FLUSHED HATCH USED FOR EMERGENCY EXIT TO BERTH B COMPARTMENT AND CHAIN LOCKER TO NOT BE WATERTIGHT. MI HAS GIVEN TO NEXT DRYDOCK TO RECTIFY DEFICIENCY.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2025
Resolved 15 January 2026
Resolution: MI witnessed satisfactory repair and operation of hatch cover.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 May 2024
Resolved
A hinged watertight bulkhead door must be fitted with a quick action closing devise operable from both sides of the door and indicator lights at the operating station showing whether the door is open or closed. The water tight door located at frame 16 between spaces"A" and "B" does not have an alarm at the operating station. 46CFR179.330
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 30 May 2024
Resolution: Vessel's door is outfitted with required alarm. The master was unaware that the circuit breaker for the alarm was open. Vessel representative conducted familiarization training for the master and crew to ensure the alarm is armed while underway.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 May 2024
Resolved
The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred, unless precluded by safety concerns directly related to the incident. Alcohol-testing devices must be used according to the procedures specified by the manufacturer of the testing device and by this part. Alco-Swab test strips on board were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 30 May 2024
Resolution: New Alco strips provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 January 2024
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and internal structure examination at least once every two years. Vessel's drydock in due on 30DEC2023. Vessel is not scheduled for a drydock until January 8th. Vessel cannot carry passengers/cargo until drydock credit has been issued.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2024
Resolution: Vessel is in DD in Sector San [name withheld] and under inspection by attending MI's
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2023
Resolved
The owner, managing operator, or master shall report damage to machinery that renders further use of the item unsafe until repairs are made, to the OCMI at the port in which the casualty occurred or nearest the port of first arrival, as soon as practicable after the damage occurs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2023
Resolved 12 March 2023
Resolution: Operator installed new starter.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 March 2023
Resolved
Portable extinguishers must be inspected annually and
maintained in accordance with NFPA 10. In reviewing the
servicing records for firefighting equipment, it was
discovered that the last servicing of the portable
extinguishers and fixed firefighting system was
conducted in February 2022, more than one year ago.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 2 March 2023
Resolution: Received documentation attesting to servicing of firefighting equipment.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 1 March 2023
Resolved
Except on a vessel limited to daytime operations, the
compass must be illuminated. Though a wire was
discovered leading to the magnetic compass, the compass
was not able to be illuminated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2023
Resolved 30 March 2023
Resolution: Confirmed the illumination of the magnetic compass.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 March 2023
Resolved
Employers must ensure that they and their crewmembers
meet the requirements of this part (46 CFR 16). While
conducting a DAPI audit, it was noted that numerous
requirements of the chemical testing program were
missing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 9 March 2023
Resolution: Vessel operator provided updated/required DAPI documentation.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2022
Resolved
An independent modular smoke detecting unit must contain an independent power source. Smoke detector did not function properly. Prove proper operation of smoke detection prior to use of overnight accommodations.
46 CFR 181.450(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2022
Resolved 11 May 2022
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2022
Resolved
A vessel must carry one floating waterlight. Vessel's floating waterlight for lifebuoy was inoperable. Prove proper operation of waterlight prior to nighttime operations.
46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2022
Resolved 11 May 2022
Resolution: Replaced battery
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2020
Resolved
Vessel has unapproved SAE 1402 flexible hoses installed on MDE, R/G Cooler and SSDG. Provide documentation that the installed hoses meet the equivalency of J-1942 or replace hoses.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 October 2020
Resolved 13 November 2020
Resolution: MI verified proper intallation of approved J-1942 hoses. Ops tested SAT.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 23 October 2020
Resolved
Provide an MSC Lightship Letter documenting the weight change after re-power.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 October 2020
Resolved 6 March 2021
Resolution: Operator provided MSC Stability and Lightship Characteristics – Weight Changes lettter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 March 2020
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Vessel reported loss of propulsion. Vessel is required to prove proper operation of the propulsion system to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2020
Resolved 4 March 2020
Resolution: Diesel fuel system serivced to OEM standards, op test, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 February 2020
Resolved
Tubular gauge glasses, if fitted to diesel tanks, must be of heat resistant materials, adequately protected from mechanical damage, and provided at the tank connections with devices that automatically close in the event of rupture of the gauge or gauge lines.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2020
Resolved 11 February 2020
Resolution: Sight glass removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 February 2020
Resolved
Mattresses. All mattresses must comply with either: (1) The U.S. Department of Commerce “Standard for Mattress Flammability” (FF 4-72.16), 16 CFR Part 1632, Subpart A and not contain polyurethane foam; or (2) IMO Resolution A.688(17) (incorporated by reference, see 46 CFR 175.600). Mattresses that are tested to this standard may contain polyurethane foam.
Proir to carrying overnight passengers
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 March 2020
Resolution: Matresses replaced with 16 CFR 1633 compliant matresses.
Fire Fighting › Fire Hydrants › Condition
Issued 16 February 2018
Resolved
Replace the male hose fitting on #1 Fire Hydrant.
Action required: 705 - Other - as specified
Due 22 February 2018
Resolved 21 February 2018
Resolution: Vessel replaced with new.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 10 March 2017
Resolved
Clear fouled prop prior to carrying passengers
Action required: 705 - Other - as specified
Resolved 11 March 2017
Resolution: Cleared fouled prop
Sail Rigging › Chainplates › Fasteners
Issued 10 March 2017
Resolved
Replace gammon iron bolts prior to carrying passengers
Action required: 705 - Other - as specified
Resolved 11 March 2017
Resolution: replaced four gammon iron bolts.
Sail Rigging › Stays/Shrouds › Clevis Pins and Cotter Pins
Issued 10 March 2017
Resolved
Conduct satisfactory sea trial prior to using headsails
Action required: 705 - Other - as specified
Resolved 16 March 2017
Resolution: conducted satisfactory sea trail with full sails under load.
Sail Rigging › Stays/Shrouds › Turnbuckles and Toggles
Issued 10 March 2017
Resolved
Ensure proper alignment of dolphin stricker and stays prior to using headsails.
Action required: 705 - Other - as specified
Resolved 11 March 2017
Resolution: realigned dolphin strikers and stays properly.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 28 February 2017
Resolved
SYSTEM WOULD NOT SHUT DOWN THE ENGINE
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2017
Resolved 1 March 2017
Resolution: Working properly
Engineering › Bilge Water Management System › Not Operational
Issued 28 February 2017
Resolved
AUDIBLE ALARM DOES NOT WORK
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2017
Resolution: working properly
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 28 February 2017
Resolved
expired
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2017
Resolved 1 March 2017
Resolution: replaced with new
Electrical › Electric Supply System (service) › Cable
Issued 28 February 2017
Resolved
provide cover or junction box for electrical buss in forward head overhead
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 31 March 2017
Resolution: Def cleared
Communications › Radio Communications › VHF Radiotelephone
Issued 28 February 2017
Resolved
One of the two required radios does not work properly, Repair prior to voyages over 200nm.
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 31 March 2017
Resolution: Def cleared
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 February 2017
Resolved
tighten handrail
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 March 2017
Resolution: repaired
Sail Rigging › Spars › Spinnaker/Whisker Poles
Issued 6 December 2016
Resolved
Conduct satisfactory sea trial under full sail prior to carrying passengers under sail. Vessel may sail with just fore and aft sails. But not under full sail until observed by a Marine Inspector.
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 16 March 2017
Resolution: Conducted sea trial with full sail under load beyond the break wall.
Sail Rigging › Stays/Shrouds › Terminals/End Fittings
Issued 5 October 2016
Resolved
Replace all (14) stainless steel eye boldt in critical service. If bolts are found to be in serviceable condition, replacement may not be needed.
Replace mainstay bold at deck.
Provide all specifications of replacement materials.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 11 November 2017
Resolution: All eye bolts were replaced in kind. See attached purchase order from company.