Records from 2005 to 2025. Most recent: inspection, 19 September 2025.
Inspection history · 46
19 September 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8237189
18 September 2025
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8268330
15 April 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8064841
20 December 2024
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8071256
3 June 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7883217
22 February 2024
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7868995
30 March 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654606
9 March 2023
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7639854
11 January 2023
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7614685
22 October 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7605033
31 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7425421
24 March 2022
Plan Review "T" Boat · In-Service Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7613912
1 July 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7241943
17 June 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7229346
14 June 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7225550
13 June 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7322506
24 May 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7205560
17 March 2021
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7162439
11 June 2020
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6974183
10 March 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6913418
26 February 2020
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6916075
25 February 2020
Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6915993
10 February 2020
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6908750
20 October 2019
Damage Survey · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6839029
20 October 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6909444
3 June 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6699389
5 March 2019
Internal Structural Exam · In-Service Inspection · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6592090
1 August 2018
Damage Survey · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6498480
1 August 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6511078
3 April 2018
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6385933
12 March 2018
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6364741
7 December 2017
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6320644
28 August 2017
Excursion Permit · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6254133
5 July 2017
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6198960
5 July 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6247370
31 March 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6100359
10 March 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6103749
10 March 2017
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6105990
3 March 2017
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6095639
5 October 2016
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6017939
2 August 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5960915
1 August 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5959572
4 July 2016
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5938756
24 June 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5942079
3 May 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5892855
19 April 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5849280
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 September 2025
Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. On September 18th, 2025, vessel reported loss of propulsion due to a de-coupled drive shaft. Vessel must make satisfactory repairs to the drive train and perform sea trial to the satisfaction of attending CG Marine Inspector prior to movement or provide a tow plan for the towing of the vessel to its home port
Action required: 60 - Rectify deficiencies prior to movement
Due 19 September 2025
Resolved 23 September 2025
Resolution: Shaft coupling properly repaired. See narrative for details.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 April 2025
Resolved
FIRE PUMP OUTLET MUST BE FITTED WITH A PRESSURE GAUGE. MI OBSERVED PRESSURE GAUGE TO NOT MONITOR PRESSURE OF FIRE PUMP DISCHARGE.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 24 April 2025
Resolution: Operational pressure gauge installed at pump.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 April 2025
Resolved
THE CONSTRUCTION AND ARRANGEMENT OF A VESSEL MUST ALLOW FOR THE SAFE OPERATION OF THE VESSEL IN ACCORDANCE WITH THE TERMS OF ITS CERTIFICATE OF INSPECTION. MI OBSERVED NUMEROUS TEARS IN THE TOP GALLANT AND UPPER TOP SAIL LOCATED ON THE FORWARD MAST.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2025
Resolved 15 May 2025
Resolution: All sails repaired satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 March 2023
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel had missing letter of boat name on the ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 30 March 2023
Resolution: Vessel's name was clearly marked on the ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 March 2023
Resolved
Individual pumps are provided for separate spaces, individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line. Vessel had missing label of bilge manifold system on the bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 30 March 2023
Resolution: The bilge manifold was labeled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 January 2023
Resolved
Vessel representative unable to provide past third party rigging survey. Some running and standing rigging appears to be worn. Provide third party rigging survey to [email withheld]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2023
Resolution: POC provided rig survey. Survey indicated that some riggind is in need of repair/replacement. Contacted LA/LB to provide follow up.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 January 2023
Resolved
Bob Chain bolt threads found to be not engaging locknut. Replace with bolt of proper length to engage locking nut.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2023
Resolution: Replaced Bob Chain bolt.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 May 2022
Resolved
(a) At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (3) Inspection of the condition of the superstructure, masts, and similar arrangements constructed on the hull, and on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails.
MI Noted vessels rigging log calls out main mast stay collar or hounds "failing at aft stbd corner"
Provide Coast Guard repair plan within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2022
Resolved 26 August 2022
Resolution: O/O made proper repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 31 May 2022
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
MI noticed missing guard round MDE. Deficiency corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 31 May 2022
Resolved 31 May 2022
Resolution: Deficiency corrected on the spot by crew installing guard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2021
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name.Id'd lack of vessel name on life ring
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 15 December 2022
Resolution: Name placed on Lifering
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 June 2021
Resolved
A vessel to which this sub-chapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel exceeded their COI Annual Inspection due date on 12JUN21. Vessel is requires to undergo a COI Annual inspection prior to departure from port or carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2021
Resolved 1 July 2021
Resolution: Conducted annual inspection satisfactory
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2021
Resolved
A vessel that is exposed to salt water more than three
months in any 12 month period since the last examination
must undergo a drydock examination and an internal
structural at least once every two years. Vessel
exceeded two year interval on 31Mar2021. Vessel required
to undergo satisfactory drydock examination prior to
departure from port or carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2021
Resolved 17 June 2021
Resolution: Vessel completed satisfactory DD in San Diego, CA.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2020
Resolved
At least one ring life buoy must be fitted with a lifeline. None of the ring life buoys were fitted with a lifeline. Provide a lifeline for one of the ring life buoys.
46 CFR 180.70(c)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 12 March 2020
Resolution: Received email from operator with picture of properly installed lifeline. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2020
Resolved
Each ring life buoy must be marked with Type II retroreflective material. 02 of the ring life buoys were missing retroreflective material. Provide retroreflective material that will stay on ring life buoys.
46 CFR 185.604(i)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 12 March 2020
Resolution: Received email from operator with picture of properly installed retro reflective tape on life buoys. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 March 2020
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. One of the ring life buoys has a missing plug, which has allowed moisture to accumulate inside the filler material. Replace unserviceable ring life buoy.
46 CFR 176.810(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 12 March 2020
Resolution: Received email from operator with picture of renewed life buoy. All SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 March 2020
Resolved
The master shall determine that the vessel complies with all applicable stability requirements in the vessel's stability letter. Vessel's stability letter states that a Sail Plan must be kept onboard at all times, but vessel could not produce a Sail Plan. Vessel must produce a Sail Plan and keep it onboard at all times.
46 CFR 185.315(a) 16c
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 12 March 2020
Resolution: Received email from operator with picture of MSC Approved Sail Plan. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 February 2020
Resolved
Vessel reported a failure of raw water line on engine. Vessel to prove proper operation of raw water system prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2020
Resolved 27 February 2020
Resolution: Vessel proved proper operation of all systems.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 February 2020
Resolved
Mattresses. All mattresses must comply with either: (1) The U.S. Department of Commerce “Standard for Mattress Flammability” (FF 4-72.16), 16 CFR Part 1632, Subpart A and not contain polyurethane foam; or (2) IMO Resolution A.688(17) (incorporated by reference, see 46 CFR 175.600). Mattresses that are tested to this standard may contain polyurethane foam.
Proir to carrying overnight passengers
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 June 2020
Resolution: Compliant mattresses have been purchased.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 June 2019
Resolved
Provide a current Noaa registration for the vessel's 3 EPRIBs.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 19 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2019
Resolved
Found ring life buoys missing the manufacturers foam fill plug as required by CG approval. The missing plug compromises the rings serviceability. Provide serviceable ring life buoys at all three location.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 19 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2018
Resolved
Ensure proper operation of machinery prior to the carriage of passengers. Ensure vessel's fuel system is properly working in way of RACOR filters. Vessel must complete underway sea trial prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2018
Resolution: Conducted sea trial. Observed fuel racors and all propulsion machinery. All appeared satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2018
Resolved
Ensure shaft leakage is reduced to a minimum in way of the shaft seal and packing. Vessel must complete underway sea trial prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2018
Resolution: Conducted sea trial. Shaft leakage had been reduced. All appeared satisfactory.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 12 March 2018
Resolved
Provide fire servicing report for pre-engineered fire system in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2018
Resolved 28 March 2018
Resolution: MI received fire servicing report.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 12 March 2018
Resolved
Ensure shaft seal leaking is reduced to a minimum.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2018
Resolved 9 April 2018
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 12 March 2018
Resolved
Provide satisfactory proof of FCC Marine Radio Operator's License. 47 CFR 80.155
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 April 2018
Resolved 19 June 2019
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 5 July 2017
Resolved
Prove proper operation of main diesel engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2017
Resolution: Operator demonstrated proper funtion of main diesel engine.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 31 March 2017
Resolved
Label both life rings with vessel's name.
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 12 April 2017
Resolution: Def cleared
Lifesaving › Lifebuoys › Stowage
Issued 31 March 2017
Resolved
Secure lifering battery bracket
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 12 April 2017
Resolution: Def Cleared
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 March 2017
Resolved
Replace the battery for each life ring/water torch
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 12 April 2017
Resolution: Def cleared
Lifesaving › Launching Appliances › Davit
Issued 16 March 2017
Resolved
Rescue boat must be stowed starboard aft at ready for MOB emergency recovery. Jacoob's ladder will be set ready for use while underway and crew will use lifejackets when transferring via the jacob's ladder until repairs are completed to rescue boat davit.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 24 April 2017
Resolution: Davit repaired to original condition.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 March 2017
Resolved
Make aft rail permanent. Keep temporary wire/rope rail in place while underway until permanent repairs completed.
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 24 April 2017
Resolution: Railing repaired to original condition.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 10 March 2017
Resolved
Repair rescue boat davit prior to carrying passengers
Action required: 705 - Other - as specified
Resolved 16 March 2017
Resolution: Provided rescue boat towing alternative for MOB emergency recovery to the satisfaction of the attending Marine Inspector.
Sail Rigging › Stays/Shrouds › Terminals/End Fittings
Issued 5 October 2016
Resolved
Replace all eye-bolts found to have been modified from original. 18 count.
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 22 January 2017
Deck/Cargo › Holds/Tanks › Hatch
Issued 19 April 2016
Resolved
Repair/Replace 03 hatches identified to have small leaks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 2 August 2016
Resolution: MI attended vessel and observed all three hatch combings replaced in-kind. Cleared outstanding 835.
Engineering › Fuel Oil Service System › Gauge
Issued 19 April 2016
Resolved
Repair oil pressure indicator and water temperature indicator at control station
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 2 August 2016
Resolution: Observed fuel gauge in operation. Gauge was replaced in-kind.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 19 April 2016
Resolved
Provide 2015 MIS Report
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 11 November 2017
Resolution: Company unable to submit 2015 MIS report. Employee was terminated and held all information to be submitted.