MAURY USCG vessel records
← All vessels

BLACK GOLD

BLACK GOLD is a 1974 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2016, most recently in May 2026, along with 9 deficiencies and 1 casualty investigation in 2011.

Records from 2011 to 2026. Most recent: inspection, 14 May 2026.

Built
1974
Last inspected
14 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH9807
Flag
UNITED STATES
Maury page id
psix-48200

Documentation record

Registered dimensions (L × B × D)29.5 ft × 12.5 ft × 4.1 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

12 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

14 May 2026 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8373239
9 May 2025 Drydock Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8117011
25 April 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7901405
7 August 2023 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7762637
15 June 2023 Administrative Inspection · Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7690618
31 May 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7434155
25 May 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7182962
18 May 2020 Drydock Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6949060
28 May 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6697049
4 June 2018 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6433654
3 August 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6226083
17 March 2016 Deficiency Check · Annual Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5831438

Deficiency record · 9

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. MI observed fuel shutoff valve cable pull installed at an incorrect angle resulting in the valve only being able to close half-way. 46 CFR 182.20-40 (b)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 17 May 2024
Resolution: Rcvd video from company rep showing fuel shutoff valve actuating completly.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 2 October 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. MI observed inoperable bilge high level alarms in steering space and engine room. 46 CFR 182.530(a) 60 c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 2 October 2023
Resolved 5 October 2023
Resolution: Operator replaced inoperable bilge high level alarms and defective wiring. Demonstrated system function to the satisfaction of the attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 August 2023 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date of 18MAY. Vessel failed to conducted the required inspection within the inspection window, and is prohibited from conducting operations until successful completion of the required annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2023
Resolution: Vessel succesfully completed annual inspection.
Construction/Loadline › Penetrations › Weld
Issued 17 March 2016 Resolved
Cracked welds IWO P/S exhaust penetrations at stern below the waterline, actively leaking on the STBD side. Vessel will have to submit a repair proposal for review and approval to OCMI
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2016
Resolution: Completed satisfactory repair.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 17 March 2016 Resolved
ship service generator windings found to be dirty, and oiled. Vessel needs to clean and identify source of oil.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2016
Resolution: Cleaned windings and identified that oil came from external source.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 March 2016 Resolved
MI observed cracked welds and bulkhead IWO P/S exhaust manifold penetrations from engineering space to lazarette. Repair to the satisfaction of attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2016
Resolution: Completed satisfactory repair.
Engineering › Diesel Engine (propulsion-electric) › Injector (fuel injection)
Issued 17 March 2016 Resolved
Observed fuel leaks and excessive movement on P/S MDE fuel rail return line. Repair to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 March 2016
Resolution: Replaced fuel line and gasket.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 March 2016 Resolved
Ring lifebuoy water light had incorrect battery.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 March 2016
Resolution: Installed approved battery.
Engineering › Bilge Water Management System › Valve
Issued 17 March 2016 Resolved
FWD space bilge reach rod wire ties wasted and INOP. 46CFR 182.25-5 (d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 March 2016
Resolution: Renewed valve wire tie.

Casualty record · 1

15 September 2011Routine · role: Involved in a Marine Casualty · activity 4146939
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record