Records from 1981 to 2026. Most recent: inspection, 14 May 2026.
Documentation record
Registered dimensions (L × B × D)29.5 ft × 12.5 ft × 4.1 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
14 May 2026
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8373239
9 May 2025
Drydock Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8117011
25 April 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7901405
7 August 2023
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7762637
15 June 2023
Administrative Inspection · Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7690618
31 May 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7434155
25 May 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7182962
18 May 2020
Drydock Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6949060
28 May 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6697049
4 June 2018
Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6433654
3 August 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6226083
17 March 2016
Deficiency Check · Annual Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5831438
9 July 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4360086
16 September 2011
In-Service Inspection · Drydock Exam · Administrative Inspection · Examination of Repairs · Damage Survey · Plan Review "T" Boat
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4146927
15 September 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4146939
17 December 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4145756
9 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188805
21 July 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 961326
26 March 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1426768
11 February 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 954228
21 March 1991
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1233477
9 January 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1218522
1 February 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1241418
26 January 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 895098
31 March 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021937
31 March 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998012
23 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291510
20 December 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971489
29 January 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965436
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. MI observed fuel shutoff valve cable pull installed at an incorrect angle resulting in the valve only being able to close half-way.
46 CFR 182.20-40 (b)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2024
Resolved 17 May 2024
Resolution: Rcvd video from company rep showing fuel shutoff valve actuating completly.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 2 October 2023
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. MI observed inoperable bilge high level alarms in steering space and engine room.
46 CFR 182.530(a)
60 c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 2 October 2023
Resolved 5 October 2023
Resolution: Operator replaced inoperable bilge high level alarms and defective wiring. Demonstrated system function to the satisfaction of the attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 August 2023
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date of 18MAY. Vessel failed to conducted the required inspection within the inspection window, and is prohibited from conducting operations until successful completion of the required annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2023
Resolution: Vessel succesfully completed annual inspection.
Construction/Loadline › Penetrations › Weld
Issued 17 March 2016
Resolved
Cracked welds IWO P/S exhaust penetrations at stern below the waterline, actively leaking on the STBD side. Vessel will have to submit a repair proposal for review and approval to OCMI
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2016
Resolution: Completed satisfactory repair.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 17 March 2016
Resolved
ship service generator windings found to be dirty, and oiled. Vessel needs to clean and identify source of oil.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2016
Resolution: Cleaned windings and identified that oil came from external source.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 17 March 2016
Resolved
MI observed cracked welds and bulkhead IWO P/S exhaust manifold penetrations from engineering space to lazarette. Repair to the satisfaction of attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2016
Resolution: Completed satisfactory repair.
Engineering › Diesel Engine (propulsion-electric) › Injector (fuel injection)
Issued 17 March 2016
Resolved
Observed fuel leaks and excessive movement on P/S MDE fuel rail return line. Repair to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 March 2016
Resolution: Replaced fuel line and gasket.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 March 2016
Resolved
Ring lifebuoy water light had incorrect battery.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 March 2016
Resolution: Installed approved battery.
Engineering › Bilge Water Management System › Valve
Issued 17 March 2016
Resolved
FWD space bilge reach rod wire ties wasted and INOP. 46CFR 182.25-5 (d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 March 2016
Resolution: Renewed valve wire tie.
Construction/Loadline › Structures › Superstructure
Issued 16 September 2011
Resolved
Vsl had fire onboard causing completed lose to pilot house, navigation equipment, steering system, lifesaving equipment, wiring, etc. Provide repair proposal and required plans prior to commencing repairs. Make vessel available for follow on damage survey once all burnt material is removed. See narrative for amplifying information.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2012
Documentation
Issued 26 March 1993
Resolved
CONDUCT A STABILITY TEST OF VESSEL TO SATISFACTION OF ATTENDING CG INSPECTOR.
Condition: Unknown
Due 26 September 1993
Resolved 29 March 1993