Records from 1998 to 2017. Most recent: inspection, 7 June 2017.
Inspection history · 38
7 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6168191
17 May 2016
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5879749
16 May 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5879023
7 March 2016
COI Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination · MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5829037
9 February 2016
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5817474
14 May 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4859176
20 February 2012
Annual Inspection · MTSA/ISPS Verification · DAPI Audit · ACP Annual Oversight
Physical examination · Activities Europe · Activity 4202495
3 January 2011
DAPI Audit · ACP COI Oversight · MTSA/ISPS Verification · COI Inspection
Physical examination · Activities Europe · Activity 3901758
30 December 2010
Type not recorded
No type recorded · Activities Europe · Activity 3919212
8 January 2009
Internal Structural Exam · ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 3385758
28 July 2008
Administrative Inspection
Administrative · Activities Europe · Activity 3281730
1 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3245297
18 February 2008
Annual Inspection
Physical examination · Activities Europe · Activity 3155268
16 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2749829
21 January 2006
COI Inspection
Physical examination · Activities Europe · Activity 2556394
26 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501665
15 May 2005
Annual Inspection
Physical examination · Activities Europe · Activity 2353677
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293972
14 February 2005
Administrative Inspection
Administrative · Activities Europe · Activity 2291958
18 June 2004
MTSA/ISPS Verification · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2108512
26 January 2004
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1992659
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979569
18 March 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1759118
26 March 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1597494
4 March 2002
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1490860
7 December 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772739
12 April 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448251
26 January 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439150
28 March 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393378
27 August 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 227025
20 August 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 92389
10 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1129240
5 February 1999
Deadweight Survey · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411816
19 October 1998
Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 801572
22 September 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465427
19 September 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 27464
19 September 1998
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 453543
17 September 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 15427
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 7 March 2016
Resolved
COI expired on 04Jan2016. Complete all items on attached worklist prior to sailing.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2016
Resolved 1 June 2016
Resolution: Worklist and information passed to MSU Houma for Vessel Drydock and COI Inspection.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 20 February 2012
Resolved
NLS Cargo Record book not being maintained on board. Prove receipt of book on board prior to 05 MAR 12. Rcpt provided by vessel rep 28 Feb 12.
*** Compliance and maintenance of book to be confirmed by CG inspector at next annual inspection ***
Due 11 April 2013
Resolved 13 December 2012
Documentation › Logs/Records › Logbook (official)
Issued 4 January 2011
Resolved
File the Official Log Book with the Cognizant OCMI, per the period of time specified by Activities Europe, as required by 46CFR131.610, within 30 days. 5 February 2011.
Action required: 705 - Other - as specified
Due 5 February 2011
Resolved 26 January 2011
Resolution: Official Log Book recieved and routed to Investigations Department.
Navigation › Piloting/Steering › Notices to Navigation
Issued 4 January 2011
Resolved
Provide on board, adequate and up to date, nautical publications; specifically the list of lights and sailing directions for the intended voyage, within 30 days, to the satisfaction of the ACS. 5 February 2011. 74SOLAS2004(Cons.) V/27.***Extended to March 7, 2011***Extended to April 5, 2011***
Action required: 705 - Other - as specified
Due 5 April 2011
Resolved 30 March 2011
Resolution: Received class report, HC1968110 dated 30 March 2011, indicating that 835 item #2 has been cleared.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 4 January 2011
Resolved
Evidence that supervisors have received one (1) hour Employee Assistance Training, as required by 46CFR16.401, is not readily available on board. Further, the Quality, Health, and Safety Manual - EAP Section 4.4 does not clearly define the requirement or scope of this training. Evidence of required training to be provided to the USCG within 60 days. 5 March 2011.
Action required: 705 - Other - as specified
Due 5 March 2011
Resolved 3 March 2011
Resolution: Company provided documentation that the EAP supervisor training has been carried out and is clarified in the QHSE Manual.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 4 January 2011
Resolved
Vessel's International Tonnage Certificate (A990056I) does not list liquid mud tanks No. 2 P/S and 3 P/S for net tonnage. Issuing authority requested to amend ITC or provide clarification as to why the subject liquid mud tanks are not listed, within 60 days. 5 March 2011.
Action required: 705 - Other - as specified
Due 5 March 2011
Resolved 30 January 2011
Resolution: Original, corrected, copy provided on board.
Lifesaving › Rescue Boat › Construction
Issued 4 January 2011
Resolved
Provide CG approval (series 160.056) for on board rescue boat, or replace with CG approved rescue boat as required by 46CFR133.135(a) within 60 days, to the satisfaction of the USCG. 5 March 2011.***Extended to April 5, 2011***Extended to June 5, 2011***
Action required: 705 - Other - as specified
Due 5 June 2011
Resolved 21 April 2011
Resolution: Received class report HC1978824 dated 21 April 2011, attesting to the survey of the new rescue boat installation.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 4 January 2011
Resolved
*Item reported cleared via E-mail dated 18FEB11 & shall remain open until verified by CG MI*Original copy of the USCG approved automation test procedure not readily available on board, although multiple copies were found. Original approved automation test procedure to be provided on board within 60 days, to the satisfaction of the USCG. 5 March 2011.
Action required: 705 - Other - as specified
Due 4 April 2012
Resolved 20 February 2012
Navigation › Piloting/Steering › Azimuth
Issued 4 January 2011
Resolved
Provide azimuth/bearing circle or other suitable means for taking bearings as nearly as practicable over an arc of the horizon of 360 deg, to the satisfaction of the ACS, within 60 days. Once provided on board, the SOLAS Safety Equipment Certificate Form E is to be updated to reflect this equipment. 5 March 2011. 74SOLAS2001(Cons.) V/12.d.ii.***Extended to April 5, 2011***
Action required: 705 - Other - as specified
Due 5 April 2011
Resolved 11 March 2011
Resolution: Received supporting documentation from the operator, that the corrected (original) Cargo Ship Safety Equipment Certificate and compass bearing device have been provided on board.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 4 January 2011
Resolved
The A-60 class fire door, as indicated on the fire control plan, on the main deck stbd side/aft, leading from the laundry room to the accommodation has been found with cracked glass and a wasted door frame. Permanent repairs are to be made, to the satisfaction of the ACS, in order to restore A-60 integrity within 90 days. 5 April 2011.***Extended to 4 June 2011***Extended to 25 June 2011***
Action required: 705 - Other - as specified
Due 25 June 2011
Resolved 22 June 2011
Resolution: Received ABS class report, HC2004470 attesting to the replacement of the A-60 fire door.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 January 2006
Resolved
Replace missing tide and current tables and COLREGS. Cleared by e-mail dated March 1, 2006 from master [name withheld]
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Communications › Radio Communications › EPIRB
Issued 21 January 2006
Resolved
Install a Coast Guard approved hydrostatic release for the EPIRB. Cleared by e-mail dated February 28, 2006 by master [name withheld]
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 21 January 2006
Resolved
Ensure all life jackets have lights (13 without light 6 with dead batteries). Total persons allowed cannot exceed 19. This is the total number of servicable, CG approved life jackets found aboard the vessel during the examination. * Reported as cleared by email from the vessel's master, [name withheld] on February 9, 2006. *
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 21 January 2006
Resolved
Replace the fire control plan approved by MSO Morgan City in 2001 with the current approved fire control plan dated 2004. Cleared by e-mail dated February 21, 2006 by master [name withheld]
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 21 January 2006
Resolved
Install suitable connection between the manual release handles to allow simultaneous release of the engine room pilot cylinders. * Reported as cleared by email from the vessel's master, [name withheld] on February 17, 2006. *
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 21 January 2006
Resolved
Clarify and post instructions for the release of CO2 from inside the CO2 room. * Reported as cleared by email from the vessel's master, [name withheld] on February 9, 2006. *
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 21 January 2006
Resolved
Submit automation testing procedures to the Marine Safety Center for review and approval. Cleared by e-mail dated March 31, 2006 by master [name withheld]
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Engineering › Pressure Vessel › Relief Valve
Issued 21 January 2006
Resolved
Demonstrate the proper operation of both of the air compressor relief valves. Cleared by e-mail dated February 9, 2006 by master [name withheld]
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Engineering › Pressure Vessel › Marking and Stamping
Issued 21 January 2006
Resolved
Remove paint from air receiver data plates. * Reported as cleared by email from the vessel's master, [name withheld] on February 17, 2006. *
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Fire Fighting › Ventilation Systems › Operating Controls
Issued 21 January 2006
Resolved
Replace the missing remote pull handle to the emergency generator blower damper handle. * Reported as cleared by email from the vessel's master, [name withheld] on February 17, 2006. *
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Engineering › Fuel Oil Service System › Piping
Issued 21 January 2006
Resolved
Remove epoxy patch on fuel oil purifier (port side by ship generator) and make permanent repairs. * Reported as cleared by email from the vessel's master, [name withheld] on February 9, 2006. *
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Lifesaving › Launching Appliances › Falls
Issued 21 January 2006
Resolved
Replace cable for rescue boat davit (over 5 years of age) and conduct weight test. Cleared by e-mail dated March 7, 2006 from master [name withheld]
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 21 January 2006
Resolved
Ensure all engine sensors used for automation are properly operating. Cleared by e-mail dated March 28, 2006 by master [name withheld]
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Deck/Cargo › Cargo Stowage › General
Issued 21 January 2006
Resolved
Ensure all vents for oil cargo and fuel have proper flame screens. * Reported as cleared by email from the vessel's master, [name withheld] on February 9, 2006. *
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Operations/Management › Drills/Instruction › Abandon Ship
Issued 21 January 2006
Resolved
Station bill must be posted in each crew and offshore worker state room. * Reported as cleared by email from the vessel's master, [name withheld] on February 9, 2006. *
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Operations/Management › Drills/Instruction › Abandon Ship
Issued 21 January 2006
Resolved
Emergency instructions must be posted where offshore workers are carried (lounge area). * Reported as cleared by email from the vessel's master, [name withheld] on February 9, 2006. *
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Lifesaving › Launching Appliances › Winch
Issued 21 January 2006
Resolved
Repair or replace the fast rescue boat limit switch. * Reported as cleared by email from the vessel's master, [name withheld] on February 9, 2006. *
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Lifesaving › Launching Appliances › Davit
Issued 21 January 2006
Resolved
Repair the davit so the fast rescue boat can be launched within five minutes. * Reported as cleared by email from the vessel's master, [name withheld] on February 9, 2006. *
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 17 December 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 May 2005
Resolved
Prove proper operation of OWS. Chief engineer stated OWS had not worked since last CG inspectio in JUN04. Overboard discharge plug was pulled by C/E and oil was present.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 2 December 2005
Resolution: Cleared by [name withheld].
Deck/Cargo › Cargo Stowage › General
Issued 15 May 2005
Resolved
Prove annual testing of P/V valves on cargo tanks.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 2 December 2005
Resolution: Cleared by [name withheld].
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 15 May 2005
Resolved
Prove automation of MDE's and generators. Engineer did not have proper equipment for all testing iaw automation procedures.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 21 January 2006
Resolution: Vessel had equipment aboard for testing the automation, however, the written procedures were not approved. Refer to CG-835 item EUR07 dated January 21, 2006 (activity #2556394) for details.
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 15 May 2005
Resolved
Repair oil and water leaks on port and starboard generators.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 2 December 2005
Resolution: Cleared by [name withheld].
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 15 May 2005
Resolved
Bolt fuel meter to frame.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 2 December 2005
Resolution: Cleared by [name withheld].
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 15 May 2005
Resolved
Install rubber mat by engine room switchboard.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 2 December 2005
Resolution: Cleared by [name withheld].
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 May 2005
Resolved
Repair emergency light in generator room.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 2 December 2005
Resolution: Cleared by [name withheld].
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 15 May 2005
Resolved
Find plug for the containment on the fuel bunkering station.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 2 December 2005
Resolution: Cleared by [name withheld].
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 15 May 2005
Resolved
Rescue boat gear has several items outdated and not CG-approved. Review all required equipment for rescue boat and insure it is operational, within service life, and CG approved if required.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 2 December 2005
Resolution: Cleared by [name withheld].
Engineering › Non-conventional Propulsion/Steering › Clutch (z-drive)
Issued 15 May 2005
Resolved
Prove proper operation of clutch light on port Z-drive.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 2 December 2005
Resolution: Cleared by [name withheld].
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 15 May 2005
Resolved
Repair compass in Z drive room.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 21 January 2006
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 15 May 2005
Resolved
Get current copy of the ISM DOC onboard.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 2 December 2005
Resolution: Cleared by [name withheld].
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 15 May 2005
Resolved
Fire detection panel shows trouble light for zone C1 (mess and bunk area). Correct trouble light.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 2 December 2005
Resolution: Cleared by [name withheld].
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 15 May 2005
Resolved
Latest Notice to Mariners onboard is dated JAN05. Provide better system for NTM updates to vessel (3 months at most).
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 2 December 2005
Resolution: Cleared by [name withheld].
Accommodation/Occupational Safety › Ventilation › General
Issued 2 February 2004
Resolved
Reconfigure ventilation system located in the air conditioning space intake containing batteries on 02 deck level. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 2 March 2004
Resolved 21 January 2006
Communications › Alarms/Indicators
Issued 2 February 2004
Resolved
Repair bilge alarms in cargo room and steering room. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2004
Resolved 2 February 2004
Communications › Visual Communication
Issued 2 February 2004
Resolved
Repair blue call light in engine room. LEGACY COMPONENT DESC: Signaling Lamp
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2004
Resolved 2 February 2004
Engineering › Fuel Oil Service System
Issued 2 February 2004
Resolved
Provide chaffing gear on fuel hoses on all main engines. LEGACY COMPONENT DESC: Hose
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2004
Resolved 2 February 2004
Electrical › Electric Supply System (service)
Issued 17 March 2003
Resolved
PROVIDE PROPER BATTERY INSTALLATION FOR BATTERIES LOCATED AT 02 LEVEL VENTILATION SPACE. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 2 February 2004
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 17 March 2003
Resolved
RENEW ALL BATTERIES IN ALL LIFEJACKETS.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2003
Resolved 17 March 2003
Communications › Radio Communications
Issued 17 March 2003
Resolved
RENEW HYDROSTAT RELEASE PRIOR TO SAILING. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2003
Resolved 17 March 2003
Engineering › Fuel Oil Service System › Filter
Issued 17 March 2003
Resolved
PROVIDE METALLIC PLUG FOR PORT GENERATOR FUEL FILTER.
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 17 March 2003
Engineering › Fuel Oil Service System
Issued 17 March 2003
Resolved
REPAIR 2 FUEL LINES ON STARBOARD GENERATOR FUEL SYSTEM. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 17 April 2003
Resolved 17 March 2003
Stability › Watertight Integrity
Issued 17 March 2003
Resolved
ADJUST WATERTIGHT DOOR LEADING TO GALLEY SPACE. LEGACY COMPONENT DESC: WATERTIGHT DOORS
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2003
Resolved 17 March 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 17 March 2003
Resolved
INSTALL PROPER FLAME SCREENS IN ALL LIQUID MUD VENTS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2003
Resolved 17 March 2003
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 26 March 2002
Resolved
PRIOR TO VESSEL MOVEMENT DEMONSTRATE PROPER OPERATION OF THE EMERGENCY FIRE PUMP
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2002
Resolved 26 March 2002
Communications › Alarms/Indicators
Issued 26 March 2002
Resolved
DEMONSTRATE PROPER OPERATION OF ALL ENGINE ROOM, BULK ROOM, AND "Z" RIVE ROOM GENERAL ALARM LIGHTS. LEGACY COMPONENT DESC: General Alarm
Condition: Improper Installation
Due 2 April 2002
Resolved 17 March 2003
Communications › Internal Communications System
Issued 26 March 2002
Resolved
DEMONSTRATE PROPER OPERATION OF THE "Z" DRIVE SOUND POWERED PHONE AUDIBLE AND VISUAL CALL INDICATORS UNDER NORMAL POWER. LEGACY COMPONENT DESC: Sound-powered Telephone
Condition: Improper/Lack of Maintenance
Due 26 April 2002
Resolved 17 March 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 March 2002
Resolved
INSTALL 2 INCH PIPING EXTENSION ON FIXED CO2 SYSTEM BRANCH LINE FOR PAINT LOCKER. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 26 April 2002
Resolved 17 March 2003
Engineering › Bilge Water Management System › Manifold
Issued 26 March 2002
Resolved
PROPERLY LABEL ALL BILGE MANIFOLD VALVES
Condition: Improper/Lack of Maintenance
Due 26 March 2002
Resolved 26 March 2002
Accommodation/Occupational Safety › Ventilation
Issued 26 March 2002
Resolved
REINSTALL MISSING GUARDS AND REMOVE ALL EXTENSION CORDS SERVING AS PERMANENT WIRING ON ALL PORTABLE BLOWERS UTILIZED FOR PILLAR BEARING COOLING. LEGACY COMPONENT DESC: GUARDS
Condition: Improper Installation
Due 26 March 2002
Resolved 26 March 2002
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 26 March 2002
Resolved
REPAIR VISUAL ALARM INDICATOR FOR THE STBD #2 STEERING SYSTEM LOSS OF POWER ALARM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2002
Resolved 2 April 2002
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 March 2002
Resolved
PROVIDE UPDATED LIGHT LIST.
Condition: Placed in Improper Service
Due 26 March 2002
Resolved 26 March 2002
Lifesaving › Line-Throwing Appliances › Lines
Issued 26 March 2002
Resolved
PROVIDE 1500FT OF 9000LB MESSENGER LINE FOR LINE THROWING APPLIANCE
Condition: Improper Installation
Due 26 March 2002
Resolved 26 March 2002
Engineering › Diesel Engine (auxiliary)
Issued 26 March 2002
Resolved
DEMONSTRATE PROPER OPERATION OF THE PORT SSDGEN OVERSPEED PROTECTION DEVICE. LEGACY COMPONENT DESC: Overspeed Device
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2002
Resolved 17 March 2003
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 26 March 2002
Resolved
PROPERLY SECURE WASHER AND DRYER
Condition: Improper Installation
Due 26 March 2002
Resolved 26 March 2002
Fire Fighting
Issued 26 January 2001
Resolved
Demonstrate proper operation of emergency fire pump to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 26 January 2001
Resolved 26 January 2001
Navigation
Issued 28 March 2000
Resolved
PROVIDE MANEUVERING DATA AS REQUIRED BY 33 CFR 164.35 (G), TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 March 2000
Resolved 28 March 2000
Navigation
Issued 28 March 2000
Resolved
PROVIDE MEANS OF STORING THE DEPTH RECORDERDATA OUTPUT OR DEMONSTRATE COMPLIANCE WITH 33 CFR 164.35 (H) AND (I), TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 March 2000
Resolved 28 March 2000