Records from 1998 to 2010. Most recent: operational control imposed, 16 February 2010.
Inspection history · 28
16 February 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3680564
13 December 2007
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3114942
13 June 2007
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2960724
22 April 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2921309
9 May 2006
MTSA/ISPS Verification · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2644708
17 March 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2312664
25 February 2005
MTSA/ISPS Verification · Hull Examination · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2305214
1 February 2005
Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2284454
23 September 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2202808
7 June 2004
MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2066544
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971025
24 July 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1869502
28 March 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1772096
19 March 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1759762
19 February 2003
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1746693
12 February 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1743178
19 November 2002
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1707790
3 June 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1625768
19 April 2001
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395693
21 July 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395521
23 May 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 767129
15 May 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 211232
24 February 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049146
12 October 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 790154
6 October 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040598
19 May 1999
Hull Examination · Inclining Experiment · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472686
16 March 1999
Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462727
3 December 1998
Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452458
Engineering › Bilge Water Management System › Pump
Issued 25 February 2005
Resolved
Provide means to ensure forward main compartment bilge remains free of water. Currently, the shower and A/C unit drain directly into the bilge.
Due 4 April 2005
Resolved 9 May 2006
Engineering › Thrusters › Tunnel
Issued 1 February 2005
Resolved
provide USCG plan approval for new hydraulic bow thruster unit prior to next inspection. plans approved by ABS and submitted via 10-92 and pend approval.
Due 24 April 2005
Resolved 9 May 2006
Engineering › Generator (propulsion/auxiliary-electric)
Issued 19 February 2003
Resolved
Ensure compliance with 46 CFR 183.320 by installing 50 degree C rated generators or derate IAW 46 CFR 183.320(b) (2) and 183.320(d).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2003
Resolved 19 March 2003
Resolution: Documentation provided IWO derating.
Engineering
Issued 12 October 1999
Resolved
PROVIDE USCG APPROVED PLANS FOR THE FUEL HEAD TANK SYSTEM IN THE ENGINEROOM.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Navigation
Issued 19 May 1999
Resolved
Provide on board a compass deviation card.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Fire Fighting
Issued 19 May 1999
Resolved
Prior to the carriage of passengers and/or cargo, conduct a man overboard, abandon ship, and fire drill as required by 46 CFR 185.57 and 46 CFR 185.524 in the presence of a U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999
Documentation
Issued 19 May 1999
Resolved
Provide approved plans for the computer based propulsion controls as per 46CFR 177.202(b)(3)(i) to demonstrate compliance with 46 CFR 61.40-3 and the requirements set forth in 46 CFR 184.620(c).
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Documentation
Issued 19 May 1999
Resolved
Provide an Employee Assistance Program and associated training for the ships crewmen as required by 46 CFR subchapter A, part 16.
Condition: Unknown
Due 28 July 1999
Resolved 28 July 1999