Records from 1982 to 2007. Most recent: inspection, 22 April 2007.
Inspection history · 78
22 April 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2921309
9 June 2005
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2548689
21 March 2005
Hull Examination · Deficiency Check · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2329339
1 June 2004
Periodic Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2078017
3 September 2003
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1895881
2 July 2003
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1833332
19 May 2003
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1796885
7 June 2002
Deficiency Check · Administrative Inspection · Annual Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1626924
15 February 2002
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1486873
19 November 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1075754
10 August 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 26668
19 June 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1070681
14 April 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061607
22 March 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1060377
4 March 2001
Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1429498
9 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821843
12 July 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 819673
7 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050862
30 May 2000
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1049437
17 March 2000
Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472766
15 March 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815515
3 February 2000
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 814423
8 December 1999
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 812734
13 September 1999
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 783309
19 April 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1124676
2 April 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 784555
9 March 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 803046
4 March 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1438798
19 March 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464751
9 March 1997
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1380764
7 November 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 859933
4 October 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1161163
6 September 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442459
10 May 1996
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1080298
10 May 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1371401
20 October 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1193384
25 September 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 878622
20 July 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1188350
10 June 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1462445
27 September 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1174990
25 August 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425495
10 March 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 855285
15 September 1993
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1403680
23 July 1993
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465755
11 June 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 839375
10 June 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1354400
22 July 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 956141
18 June 1992
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 829583
5 June 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1206357
7 May 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232363
22 April 1991
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 924441
24 September 1990
Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 901837
17 July 1990
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1220090
17 April 1990
Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1235984
19 June 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 919258
7 June 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 889025
22 August 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1345476
22 March 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1041447
29 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275561
4 December 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013344
26 October 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017264
6 October 1987
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1024108
15 April 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329038
12 February 1987
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1012926
12 December 1986
Deficiency Check · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1316708
24 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996787
19 February 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987998
3 February 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998142
29 January 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305890
22 January 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987148
24 June 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1290624
16 May 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1288342
21 April 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1289844
12 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977935
23 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279654
12 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972453
27 May 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1274308
6 December 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 963602
Fire Fighting › Grease Extraction Hood › General
Issued 21 March 2005
Resolved
Prove fire suppression systems in both galleys by fire servicing report.
Due 15 April 2005
Resolved 25 April 2005
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 21 March 2005
Resolved
Prove operation of remote fuel oil shutdown on both fuel oil transfer pumps (46 CFR 58.01-25).
Due 22 April 2005
Resolved 25 April 2005
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 21 March 2005
Resolved
Prove proper operation of all alarms for purged and pressurized cabinets on drill floor before unit begins drilling operations.
Due 22 April 2005
Resolved 27 March 2005
Engineering › Feedwater/Condensate Water System › Valve, Relief
Issued 21 March 2005
Resolved
Make all potable hot water heaters ready for internal inspection OR replace temperature relief valve with 100 PSI or less.
Due 22 April 2005
Resolved 2 April 2005
Lifesaving › Lifeboat › Markings
Issued 21 March 2005
Resolved
Replace retro-reflective material on lifeboat #1 around outer walkway and in other areas as needed.
Due 22 April 2005
Resolved 27 March 2005
Construction/Loadline › Hull › Hull Plating
Issued 21 March 2005
Resolved
Properly adjust water tight doors on main deck.
Due 22 April 2005
Resolved 27 March 2005
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 21 March 2005
Resolved
Renew skirting on helo deck where broken and re-clamp existing skirting where it is sagging.
Due 22 April 2005
Resolved 26 March 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 March 2005
Resolved
Replace white perimeter helo deck light with a red lens.
Due 22 April 2005
Resolved 26 April 2005
Electrical
Issued 2 June 2004
Resolved
Prove proper operation of purge & pressurized alarm on Varco top drive panel on drill floor.
Due 2 July 2004
Resolved 4 June 2004
Lifesaving › Lifeboat
Issued 2 June 2004
Resolved
Prove proper operation of #1 lifeboat by launching and operating in the water. Ensure both lifeboats are operated in the water at least every 90 days IAW 109.213(d)(3).
Due 2 July 2004
Resolved 5 June 2004
Operations/Management
Issued 11 July 2003
Resolved
Provide copies of fly leaves for ops manual Rev. 3 bearing CG & ABS approval stamps.
Due 11 August 2003
Resolved 27 August 2003
Electrical
Issued 11 July 2003
Resolved
Prove purge alarms for top drive control panel and derick camera monitor & schlumberger unit.
Due 11 August 2003
Resolved 27 August 2003
Lifesaving
Issued 11 July 2003
Resolved
Provide hydrostatic release for EPIRB.
Due 11 August 2003
Resolved 27 August 2003
Lifesaving › Lifejacket/PFD (General)
Issued 11 July 2003
Resolved
Provide lifejacket lights for all PFD's bearing 161.112 approval IAW 46 CFR 108.580(b)(3)(i).
Due 11 August 2003
Resolved 27 August 2003
Operations/Management › Drills/Instruction
Issued 2 July 2003
Resolved
Update station bill to reflect accurate lifeboat commander and assistant commander assignments.
Due 11 August 2003
Resolved 27 August 2003
Fire Fighting › Fire Main
Issued 19 June 2002
Resolved
REPLACE WASTED SECTION OF FIRE MAIN AT FIRE STATION #15 ON PORT SIDE OF HELIPORT.
Due 19 July 2002
Resolved 12 July 2002
Resolution: FIRE MAIN SECTION RENEWED.
Operations/Management › Drills/Instruction
Issued 19 June 2002
Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Due 19 July 2002
Resolved 12 July 2002
Resolution: DRILLS SUCCESSFULLY COMPLETED.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 19 June 2002
Resolved
CONDUCT THE FOLLOWING TESTS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR: OVERSPEED FOR SSGs, TOTAL RIG SHUTDOWN, AUTO START OF EMERGENCY GENERATOR.
Due 19 July 2002
Resolved 12 July 2002
Construction/Loadline › Structures
Issued 19 June 2002
Resolved
CROP AND RENEW, BACK TO GOOD STEEL WASTED AREA ON PORT, AFT SIDE UNDER WATER TIGHT DOOR AND DOUBLED SECTION OF ACCESS TO HALLIBURTON ROOM ON STBD SIDE.
Due 19 July 2002
Resolved 12 July 2002
Lifesaving
Issued 4 March 2001
Resolved
PROVIDE PROVISIONS FOR BOTH LIFEBOATS IAW 46CFR108.575(B).
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Construction/Loadline
Issued 4 March 2001
Resolved
CROP AND RENEW HOLE IN BULKHEAD IN LAUNDRY ROOM.
Condition: Unknown
Due 4 March 2001
Resolved 4 March 2001
Electrical
Issued 4 March 2001
Resolved
REPLACE HOLED BATTERY BOXES PORT SIDE.
Condition: Unknown
Due 4 March 2001
Resolved 4 March 2001
Fire Fighting
Issued 17 March 2000
Resolved
CROP AND RENEW FIRE MAIN PIPING WHERE WASTED OUTSIDE REC. ROOM DOOR PORT SIDE.
Condition: Unknown
Due 28 April 2000
Resolved 28 April 2000
Construction/Loadline
Issued 17 March 2000
Resolved
TANK 8P C/R 5TH HORIZONTAL STIFFENER DOWN FROM TOP ON AFT BULKHEAD, AND UT BULKHEAD FWD OF CHECK VALVE OF UMP VALVE. TANK 8S REPALCE SOUNDING TUBE. C/R OVERHEAD STIFFENERS AROUND ACCESS HATCH IN NO. 1C AND TIGHTEN UP REACH ROD CONNECTIONS.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Construction/Loadline
Issued 17 March 2000
Resolved
SUBMIT UNDERWATER DIVE VIDEO AND REPORT TO [name withheld].
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Electrical
Issued 17 March 2000
Resolved
PROPERLY SECURE WIRING, PROPERLY MOUNT J-BOXES AND SPEAKER, REPLACE MISSINGFASTENERS ON EXPLOSION PROOF FIXTURES, LOCATED WITHIN HAZARDOUS LOCATIONS.
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Construction/Loadline
Issued 17 March 2000
Resolved
ADJUST/REPAIR CHECK VALVES IN TANKS ON STBD SIDE AND 7P. GAUGE OR C/R OVERHEAD STIFFENERS IN 7P WHERE OVERHEAD IS 4 FEET HIGH. C/R VERTICAL STIFFENERS ON SWASH BKHD. THROUGHOUT TANK 7P.
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Lifesaving
Issued 17 March 2000
Resolved
PROVIDE RECURRENT FIRE-FIGHTING TRAINING EVERY 2 MONTHS TO REGULAR CREW ANDINDUSTRIAL PERSONNEL AND LOG PROPERLY. LOWER LIFEBOATS TO WATER AT EACH DRILL AND LOG.
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Lifesaving
Issued 17 March 2000
Resolved
CROP AND RENEW WASTED AND HOLED SECTIONS OF MOTOR SHED ROOF. CROP AND RENEWWASTED AND HOLED SECTIONS OF HANDRAILS, GRATINGS AND LADDER SUPPORTS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Construction/Loadline
Issued 17 March 2000
Resolved
REF. DIAGRAM NO. 1 & 2, GAUGE AREAS AS DIRECTED. SUBMIT GAUGING REPORT AND PREVIOUS GAUGING REPORT TO [name withheld]. C/R WASTED STIFFENERS ON SIDESHELL, OVERHEAD AND BOTTOM PLATING WHERE WASTED IN PRELOAD TANKS # 6, 7, AND 8 STBD.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Electrical
Issued 17 March 2000
Resolved
CROP AND RENEW OR REPAIR DOOR BETWEEN MUD PITS AND MUD PUMP ROOM. MUD PIT DOORS TO BE SELF-CLOSING AND GAS TIGHT.
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Lifesaving
Issued 17 March 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Electrical
Issued 4 March 1999
Resolved
REMOVE PLASTIC WIRE TIES ON ALL OVERHEAD RUNS ON DRILL FLOOR, SHALE SHAKER AREA AND ABOVE COLD START A/C.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Electrical
Issued 4 March 1999
Resolved
REMOVE DEAD-END WIRES ON BULKHEAD BY EXHUST FOR MAIN ENGINES BELOW LIFE RINGS.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Deck/Cargo
Issued 4 March 1999
Resolved
REPLACE FLEXIBLE HOXE BY SHALE SHAKER AREA
Condition: Unknown
Due 4 March 1999
Resolved 12 March 1999
Electrical
Issued 4 March 1999
Resolved
LABEL AND REPLACE ALL SWITCHES IN MUD PIT ROOM.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Construction/Loadline
Issued 4 March 1999
Resolved
REPAIR HOLE IN DECK BY ENTRANCE TO ENGINE ROOM ON STBD SIDE AFT OF ACCOMIDATIONS.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Electrical
Issued 4 March 1999
Resolved
PROVIDE COVER OVER LIGHT IN SCR ROOM.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Electrical
Issued 4 March 1999
Resolved
REMOVE DEAD-END CABLE THROUGHOUT RIG.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Accommodation/Occupational Safety
Issued 4 March 1999
Resolved
ENSURE PROPER OPERATION OF MARINE SANITATION DEVICE.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Electrical
Issued 4 March 1999
Resolved
REPAIR ALL SHUTDOWN BOXES AND REMOVE EXCESS SHUTDOWN BOXES.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Electrical
Issued 4 March 1999
Resolved
PROVIDE COVER FOR BATTERY ON COLD START A/C.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Electrical
Issued 4 March 1999
Resolved
REPAIR OIL LEAKS ON #3 GENERATOR HAND HOLE AND HEAD COVERS.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Fire Fighting
Issued 4 March 1999
Resolved
INSTALL HANDLE ON FIRE DAMPER IN MAIN DECK CORRIDOR.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Engineering
Issued 4 March 1999
Resolved
REPAIR PORT AND STBD CONTAINMENT AND BRACKETS FOR MANIFOLD.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Fire Fighting
Issued 4 March 1999
Resolved
REPLACE ALL BATTERIES IN FIRE DETECTORS AS NEEDED (LAUNDRY ROOMS, ACCOMMODATION SPACES, ETC.)
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Construction/Loadline
Issued 4 March 1999
Resolved
REPLACE FLEX COUPLING ON BALLAST PUMPS IN MUD PUMP ROOM.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Accommodation/Occupational Safety
Issued 4 March 1999
Resolved
REPAIR STARBOARD DOOR LEADING TO OUTSIDE ON 02 LEVEL AND ENSURE PROPER CLOSURE.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Fire Fighting
Issued 4 March 1999
Resolved
REPAIR ALL BROKEN SAFETY CHAINS ON FIRE NOZZLES
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Deck/Cargo
Issued 4 March 1999
Resolved
REPAIR FIBERGLASS DAMAGE AROUND BATTERIES, REPLACE DAMAGED BATTERIES, REMOVE DEAD END WIRES AND REPLACE TIRES WITH TIRES WITH TREAD ON TIRES FOR FORKLIFT.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Electrical
Issued 4 March 1999
Resolved
REPAIR BROKEN LIGHT IN MUD PIT ROOM.
Condition: Unknown
Due 4 March 1999
Resolved 12 March 1999
Construction/Loadline
Issued 4 March 1999
Resolved
CONDUCT TEST ON BILGE SYSTEMS.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Unknown
Issued 4 March 1999
Resolved
CONDUCT TEST ON ALL SAFETIES FOR AIR RECEIVERS AND BULK TANKS.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Engineering
Issued 4 March 1999
Resolved
ENSURE SCREENS AND VENT COVERS ON ALL GOOSENECKS.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Construction/Loadline
Issued 4 March 1999
Resolved
ENSURE TANK COVER ON PORT SIDE NEXT TO 6P PRELOAD TANK IS WATERTIGHT.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Construction/Loadline
Issued 4 March 1999
Resolved
PLACE PIN IN HINDGE FOR HATCH ON PORT SIDE AFT OF ACCOMMODATIONS.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Lifesaving
Issued 4 March 1999
Resolved
ENSURE ALL EYE WASH STATIONS HAVE CAPS OVER NOZZLES.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Lifesaving
Issued 4 March 1999
Resolved
PLACE BOTTLES AT ALL BOTTLE EYE STATIONS THROUGHOUT RIG.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Accommodation/Occupational Safety
Issued 4 March 1999
Resolved
REPAIR SELF-CLOSING DOOR TO SHOWER ROOM ON 02 LEVEL.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Fire Fighting
Issued 4 March 1999
Resolved
FREE UP ALL FIRE DAMPERS IN THE ACCOMMODATION CORRIDORS & SPACES.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Documentation
Issued 19 March 1998
Resolved
DEMONSTRATE COMPLIANCE WITH 46 CFR 109.213 FOR EMERGENCY TRAINING AND DRILLS.
Condition: Unknown
Due 19 May 1998
Resolved 29 April 1998
Engineering
Issued 19 March 1998
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY GENERATOR OVERSPEED TRIP AND ENGINESHUTDOWN.
Condition: Unknown
Due 19 April 1998
Resolved 29 April 1998
Fire Fighting
Issued 9 March 1997
Resolved
DISCONNECT FLARE BOOM SPRINKLER SYSTEM FROM FIREMAIN SYSTEM AND INSTALL AN INDEPENDENT WATER SUPPLY FOR THE FLARE BOOM SPRINKLER SYSTEM.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Engineering
Issued 9 March 1997
Resolved
INSTALL MECHANICAL GUARDS ON ALL BULK OIL TANK SIGHT GLASSES.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Construction/Loadline
Issued 6 September 1996
Resolved
PROVIDE [name withheld] OF ALL VIDEO AND WRITTEN REPORTS OF UNDERWATER SURVEY CONDUCTED IN SEPTEMBER 1996. ENSURE ABS SURVEYOR IS WITNESS TO ALL THREE LEG TO CAN INSPECTIONS.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Engineering
Issued 10 May 1996
Resolved
RENEW ALL FIVE (5) HOT WATER HEATER PRESSURE/TEMPERATURE RELIEF VALVES WITH=or< 100 PSI / =or< 210 DEG. F, RELIEF VALVES.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Construction/Loadline
Issued 10 May 1996
Resolved
Conduct underwater leg-to-can connection portion of Special Examination in Lieu of Drydocking (SEILODD) in presence of CG inspector.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Deck/Cargo
Issued 10 May 1996
Resolved
MAKE AIR RECEIVERS (2EA) UNDER RIG FLOOR AVAILABLE FOR INTERNAL INSPECTION AND RELIEF VALVE TESTING.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Construction/Loadline
Issued 10 May 1996
Resolved
MAKE PRE-LOAD TANKS #2 AFT PORT/STBD AVAILABLE FOR INTERNAL INSPECTION AND INSPECTION OF PRE-LOAD DUMP AND CHECK VALVES.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Construction/Loadline
Issued 10 June 1995
Resolved
MAKE REPAIRS TO BENT "I" BEAM UNDER DECK DIAGONAL SUPPORT BRACE ON STARBOARD FORWARD CORNER OF HELO DECK.
Condition: Unknown
Due 10 June 1995
Resolved 10 June 1995
Lifesaving
Issued 10 June 1995
Resolved
REPLACE ONE (1) BROKEN OAR FOR #1 LIFEBOAT (PORT).
Condition: Unknown
Due 10 June 1995
Resolved 10 June 1995
Lifesaving
Issued 10 June 1995
Resolved
REPAIR SELF-CLOSING GASTIGHT DOORS TO MUDPIT ROOM AND ENSURE BOTH CLOSE ANDSEAL PROPERLY.
Condition: Unknown
Due 10 June 1995
Resolved 10 June 1995
Fire Fighting
Issued 10 June 1995
Resolved
SERVICE OR REPLACE PORT BV SEMI-PORTABLE WHEEL UNIT ON HELO DECK. (IF SENT IN FOR SERVICING, A REPLACEMENT MUST BE ON BOARD DURING SERVICING)
Condition: Unknown
Due 10 June 1995
Resolved 10 June 1995
Accommodation/Occupational Safety
Issued 10 June 1995
Resolved
REPLACE WASTED PERIMETER SKIRT SUPPORT TUBE ON STARBOARD FORWARD CORNER OF HELO DECK.
Condition: Unknown
Due 10 June 1995
Resolved 10 June 1995
Accommodation/Occupational Safety
Issued 10 June 1995
Resolved
REPLACE BOTH CHAIN LADDERS ON PORT AND STARBOARD SIDESHELL (MEANS OF EMBARKATION).
Condition: Unknown
Due 10 June 1995
Resolved 10 June 1995
Electrical
Issued 10 June 1995
Resolved
REPLACE ONE (1) EXPANSION JOINT ON #1 GENERATOR COOLING WATER PIPING AND TWO (2) ON #3 GENERATOR.
Condition: Unknown
Due 10 June 1995
Resolved 10 June 1995
Electrical
Issued 25 August 1994
Resolved
MAKE REPAIRS TO ANNUNCIATOR PANEL FOR ALARMS ON #3 MAIN GENERATOR AND PROVEPROPER OPERATION.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Accommodation/Occupational Safety
Issued 25 August 1994
Resolved
PROVIDE ASME APPROVED RELIEF VALVES RATED AT OR BELOW 100 PSI ON POTABLE AND SANITARY WATER TANKS. INSTALL RELIEF VALVE WITH HAND RELIEVING GEAR ONBULK AIR RECEIVER IN WATERMAKER ROOM.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Fire Fighting
Issued 25 August 1994
Resolved
CONDUCT ANNUAL SERVICING OF FIXED FIRE FIGHTING SYSTEMS IN ENG/SCR ROOMS AND PAINT LOCKER.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Lifesaving
Issued 25 August 1994
Resolved
REPAIR EXHAUST LEAK ON STBD (#2) LIFEBOAT, PROVIDE TWELVE (12) PARACHUTE FLARES IN PORT (#1) LIFEBOAT, AND REPAIR STEERING ARMS ON BOTH LIFEBOATS WHERE LOCK WASHERS INSTALLED.
Condition: Unknown
Due 25 August 1994
Resolved 25 August 1994
Construction/Loadline
Issued 23 July 1993
Resolved
MAKE UPPER HULL AVAILABLE FOR INTERNAL/EXTERNAL INSPECTION.
Condition: Unknown
Due 23 July 1993
Resolved 23 July 1993
Unknown
Issued 10 June 1993
Resolved
MAKE AVAILABLE BARITE BULK TANKS FOR INTERNAL EXAM BY CG MARINE INSPECTOR.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Electrical
Issued 10 June 1993
Resolved
PROVE PROPER OPERATION OF ALL REVERSE POWER RELAYS ON MAIN GERERATOR #1, 2,& 3.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Documentation
Issued 10 June 1993
Resolved
SUBMIT SEILOD PROPOSAL TO COGNIZANT OCMI AND CONDUCT SEILOD EXAM NO LATER THAN 15 AUG 93.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Engineering
Issued 10 June 1993
Resolved
MAKE PERMANENT REPAIRS IN WAY OF PIN-HOLE WATER LEAK OVER #1 GENERATOR PRIME MOVER IN RAW WATER COOLING AT "T" JUNCTION.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Deck/Cargo
Issued 10 June 1993
Resolved
PROVE PROPER OPERATION OF EMERGENCY RIG SHUTDOWN.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Deck/Cargo
Issued 10 June 1993
Resolved
MAKE LARGE DRILL FLOOR AIR RECEIVER READY FOR INTERNAL EXAM & TEST RELIEF VALVE.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Lifesaving
Issued 10 June 1993
Resolved
CONDUCT FIRE & BOAT DRILLS.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Engineering
Issued 10 June 1993
Resolved
REMOVE WATER AND CLEAN OUT AIR RECEIVER ON BULK TANK COMPRESSOR AIR REICEIVER #16651 IN MSD ROOM.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Documentation
Issued 10 June 1993
Resolved
PROVIDE RECORDS AN TRANSFER EQUIPMENT WITH DATE OF MANUFACTURE AND HOSE BURST PRESSURE RATING.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Lifesaving
Issued 10 June 1993
Resolved
PROVE OPERATION OF EMERGENCY GENERATOR, TEST ALL ALARMS, AND EXAMINE "E" BATTERIES.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Electrical
Issued 10 June 1993
Resolved
TEST GENERAL ALARMS.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Electrical
Issued 5 June 1991
Resolved
REPLACE ELECTRIC WIRING IN PAINT LOCKER WITH WIRE APPROVED FOR ZONE I DIVISION I LOCATIONS.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
PROVIDE A FLAME SHIELD FOR FUEL OIL FILTER ON #2 MAIN DECK DIESEL GENERATOR.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
REPLACE ELECTRIC WIRES ON SHALE SHAKERS WITH WIRING APPROVED FOR ZONE I DIVISION I LOCATIONS.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
REPLACE ELECTRIC WIRES ON LIGHT ABOVE AFT SHALE SHAKER WITH WIRING APPROVEDFOR ZONE I DIVISION I LOCATIONS.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
PROPERLY HANG ELECTRIC WIRES RUNNING FROM DRILLER'S CONSOLE TO STARBOARD BULKHEAD AND AFT BULKHEAD ON DRILL FLOOR.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
PROPERLY HANG ELECTRIC WIRE LOCATED ON AFT OVERHEAD OF CELLAR DECK VISIBLE AT BOTTOM OF STAIRS FROM AFT OF DRILL FLOOR.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Unknown
Issued 5 June 1991
Resolved
REWELD MOUNTS FOR ROTARY DRAINAGE PIPE LOCATED AFT OVERHEAD CELLAR DECK.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Lifesaving
Issued 5 June 1991
Resolved
INSTALL EMERGENCY LIGHTING TO DAVIT LIFERAFTS (STOWED & IN WATER POSITION).
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Lifesaving
Issued 5 June 1991
Resolved
REPLACE RETROREFLECTIVE TAPE ON LIFE PRESERVERS.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Deck/Cargo
Issued 5 June 1991
Resolved
PROVIDE FLAME SCREEN FOR LUBE OIL TANK VENT LOCATED PORT FWD PORTION OF HOUSE.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
PROPERLY HANG ELECTRIC WIRES ALONG STARBOARD BULKHEAD OF CELLAR DECK.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
REPLACE ALL WIRING IN CELLAR DECK WITH WIRE APPROVED FOR ZONE 1 DIVISION I LOCATIONS OR CHANGE HAZARDOUS LOCATION PLACE TO INDICATE CELLAR DECK AS DIVISION II LOCATION.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
PROPERLY HANG ELECTRIC WIRES RUNNING FROM AMPLIFIER ENCLOSURE BOX BELOW PHONE ON STARBOARD BULKHEAD OF CELLAR DECK.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
JPROPERLY MOUNT JUNCTION BOX ON FORWARD OVERHEAD JUST OUTSIDE CELLAR DECK.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
PROVIDE FOR INSPECTION THE EMERGENCY RIG SHUTDOWN DEVICE.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Accommodation/Occupational Safety
Issued 5 June 1991
Resolved
PROVIDE FOR INTERNAL INSPECITON THE TWO DRILL FLOOR AIR SUPPLY AIR RECEIVERS LOCATED UNDER THE DRILL FLOOR.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
PROPERLY HANG LOOSE ELECTRIC WIRES RUNNING ALONG FORWARD OVERHEAD JUST OUTSIDE OF CELLAR DECK.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
PROPERLY HANG ELECTRIC WIRES LOCATED PORT OVERHEAD OF CELLAR DECK.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Fire Fighting
Issued 5 June 1991
Resolved
PROVIDE CALIBRATION GAS FOR GAS DETECTORS (2).
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Electrical
Issued 5 June 1991
Resolved
REPLACE LOUDSPEAKER IN MUD PITS WITH LOUDSPEAKER APPROVED FOR ZONE 1 DIVISION I LOCATION OR CHANGE HAZARDOUS LOCATIONS PLAN TO INDICATE MUD PITSAS DIVISION II LOCATION.
Condition: Unknown
Due 5 June 1991
Resolved 5 June 1991
Construction/Loadline
Issued 22 April 1991
Resolved
REPAIR CHECK VALVE IN STBD #2 AS PRE-LOAD BALLAST TANK TO PROVIDE COMPLETE CLOSURE.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Construction/Loadline
Issued 22 April 1991
Resolved
REPAIR CHECK VALVE IN #7 STBD PRE-LOAD BALLAST TANK TO PROVIDE COMPLETE CLOSURE.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Construction/Loadline
Issued 22 April 1991
Resolved
REPAIR CHECK VALVE IN #7 PORT PRE-LOAD BALLAST TANK TO PROVIDE COMPLETE CLOSURE.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Engineering
Issued 7 June 1989
Resolved
TEST ALL AIR RECEIVER RELIEF VALVES.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Electrical
Issued 7 June 1989
Resolved
TEST AIR PURGE ALARM FOR TOP DRIVE SYSTEM CONSOLE ON DRILLFLOOR.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Lifesaving
Issued 7 June 1989
Resolved
WEIGHT-TEST BOTH LIFEBOATS.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Engineering
Issued 7 June 1989
Resolved
TEST BILGE ALARMS.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Construction/Loadline
Issued 7 June 1989
Resolved
TEST WATERTIGHT DOOR INDICATORS AND ALARMS.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Construction/Loadline
Issued 7 June 1989
Resolved
CORRECT STUFFING TUBES FOR MUDPIT ROOM BULKHEAD PENETRATIONS FOR GAS DETECTION SYSTEM CABLES.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Electrical
Issued 7 June 1989
Resolved
REPAIR EMERGENCY LIGHT IN SCR CONTROL ROOM.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Lifesaving
Issued 7 June 1989
Resolved
NO. 2 BOAT: REPLACE MISSING HATCHET (USCG APPROVED)
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Lifesaving
Issued 7 June 1989
Resolved
WEIGHT-TEST LIFERAFT DAVIT.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Documentation
Issued 7 June 1989
Resolved
HAVE ABS PERFORM LOADLINE SURVEY.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Lifesaving
Issued 7 June 1989
Resolved
CONDUCT FIRE AND BOAT DRILL; TEST GENERAL ALARMS.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Navigation
Issued 7 June 1989
Resolved
CHECK ALL NAVIGATION LIGHTS AND OBSTRUCTION LIGHTS.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Electrical
Issued 7 June 1989
Resolved
PROVIDE AND POST HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Construction/Loadline
Issued 7 June 1989
Resolved
PROVIDE A USCG-APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Lifesaving
Issued 7 June 1989
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Lifesaving
Issued 7 June 1989
Resolved
FOR BOTH LIFEBOATS: A) REPLACE FIRST AID KIT, B) PROVIDE "MONKEY FIST" OR EQUIV. WEIGHT FOR ALL HEAVING LINES, C) PROVIDE EXTRA BATTERIES AND 2 BULBS FOR EACH MOUNTED BATTLE LANTERN, D) PROVIDE 1-LB CONDENSED MILK PER PERSON, E) REPLACE PFD LIGHTS.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Electrical
Issued 7 June 1989
Resolved
REPLACE EYS FITTING IN SHALE SHAKER.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Accommodation/Occupational Safety
Issued 7 June 1989
Resolved
LABEL THE RANGE AND DEEP-FAT FRYER EMERGENCY CUTOFFS IN BOTH GALLEYS.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Deck/Cargo
Issued 7 June 1989
Resolved
TEST ANCHORS.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Electrical
Issued 7 June 1989
Resolved
TEST EMERGENCY LIGHTING AND EXAMINE BATTERIES.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Unknown
Issued 7 June 1989
Resolved
TEST MUD PUMP RELIEF VALVES.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Unknown
Issued 7 June 1989
Resolved
DEMONSTRATE OPERATION OF HALLIBURTON-UNIT DIESEL.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Unknown
Issued 29 February 1988
Resolved
MAKE AVAILABLE THE THREE CANS FOR AN UNDERWATER INSPECTION AS PER YOUR COAST GUARD APPROVED PROPOSAL.
Condition: Unknown
Due 29 February 1988
Resolved 29 February 1988
Lifesaving
Issued 6 October 1987
Resolved
PROVIDE TWO TYPE BC-I FIRE EXTINGUISHERS FOR EACH LIFEBOAT (CAPSULES).
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Electrical
Issued 6 October 1987
Resolved
REPAIR DOOR TO MUD PIT ROOM TO PROVIDE A GAS TIGHT SEAL. 46 CFR 111.105-33
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Fire Fighting
Issued 6 October 1987
Resolved
INSTALL PROPER RELIEF VALVE FOR FIRE PUMP LOCATED IN MUD PUMP ROOM. 46 CFR 108.415-421.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Accommodation/Occupational Safety
Issued 6 October 1987
Resolved
STENCIL "BEWARE OF TAIL ROTOR" SIGNS AT EACH HELO DECK ACCESS. PRESENT SIGNS HAVE INCOMPLETE WORDING AND ARE FADED OUT.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Deck/Cargo
Issued 6 October 1987
Resolved
PROVIDE DEADMAN TYPE FUEL NOZZLE ON FUELING HOSE FOR WELEX UNIT LOCATED STBD SIDE OF CONTROL HOUSE.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Lifesaving
Issued 6 October 1987
Resolved
REWIND FALL CABLES ON PORT LIFEBOAT'S WINCH SPOOL DRUM. ONE SIDE OF DRUM IS PINCHING CABLE. ALSO SEE SPECIAL INSTRUCTIONS BELOW.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Lifesaving
Issued 6 October 1987
Resolved
REPAIR BENT I-BEAM SUPPORTING THE DAVIT LAUNCHED LIFE RAFT EMBARKATION AREA.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Fire Fighting
Issued 6 October 1987
Resolved
COAST GUARD INSPECTOR TO WITNESS FIRE DRILL AND ABANDON RIG DRILL.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Fire Fighting
Issued 6 October 1987
Resolved
PROVIDE TWO SCUBA AIR CYLINDERS WHICH ARE WITHIN APPROPRIATE HYDROSTATIC TEST DATES. (TWO GLASS WRAPPED AIR STORAGE CYLINDERS PRESENTLY ABOARD ARE OUT OF THREE YEAR HYDROSTATIC TEST PERIOD.) LAST HYDRO'D 12-81.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Accommodation/Occupational Safety
Issued 6 October 1987
Resolved
REVISE STATION BILL TO INCLUDE THE INFORMATION REQUIRED BY 46 CFR 109.501 (DUTIES AND STATION OF EVERYONE ONBOARD). PRESENT STATION BILL IS VAGUE, DOESN'T DELINEATE DUTIES, AND HAS A COUPLE ILLOGICAL ORDERS (E.G. FIREFIGHTERS TO WEAR LIFEJACKETS AND LIFEBOATMAN TO FIGHT FIRES, ETC.)
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Electrical
Issued 6 October 1987
Resolved
PROPERLY MOUNT AND SUPPORT ELECTRICAL WIRING FOR THE H2S GAS DETECTION SYSTEM AND ALL ELECTRICAL CABLE ON THE DRILL FLOOR AND SHAKER AREA NOT SUPPORTED BY CABLE TRAYS. 46 CFR 111.105.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Electrical
Issued 6 October 1987
Resolved
PROVIDE A COAST GUARD STAMPED APPROVED HAZARDOUS LOCATION PLAN ONBOARD RIG.IF APPROVED PLAN CANNOT BE LOCATED SUBMIT PLAN TO [name withheld] (OCS SECTION) FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Documentation
Issued 6 October 1987
Resolved
RENEW EXPIRED FCC SHIP RADIO STATION LICENSE.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Fire Fighting
Issued 6 October 1987
Resolved
PROVIDE DOCUMENTATION TO DEMONSTRATE THAT THE FIREMEN'S HELMETS MET ANSI STANDARD Z89.1 OR PROVIDE SUITABLE REPLACEMENTS.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Construction/Loadline
Issued 6 October 1987
Resolved
DISPLAY PROPER LOADLINE MARKINGS AS SHOWN ON CURRENT LOADLINE CERTIFICATE. (DECK LINE TO BE MARKED OPPOSITE TOP OF STEEL UPPER DECK AT SIDE.)
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Electrical
Issued 6 October 1987
Resolved
PROVIDE AND INSTALL A REMOTE FUEL OIL SHUT DOWN FOR THE EMERGENCY GENERATORAND LABEL SAME. 46 CFR SUB CHAPTER F.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Lifesaving
Issued 12 December 1986
Resolved
OPERATE BOTH LIFEBOATS IN THE WATER. OPERATE RELEASING GEAR & WATER SPRAY PUMP. THIS ITEM TO BE COMPLETED TO THE SATISFACTION OF A COAST GUARD MARINEINSPECTOR PROIR TO 15 FEBRUARY 1987.
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Unknown
Issued 29 January 1986
Resolved
PROVIDE RELIEF VALVES ON THE DISCHARGE SIDE OF THE FIRE PUMPS SET AT MAXIMUM OF 125 PSI.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Unknown
Issued 29 January 1986
Resolved
PROVIDE NONCONDUCTIVE GLOVES FOR BOTH FIREMAN'S OUTFITS.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Unknown
Issued 29 January 1986
Resolved
PROVIDE DOCUMENTATION ON BOARD THE VESSEL FOR THE DESIGNATION OF THE CRANE OPERATORS IN WRITING.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Unknown
Issued 29 January 1986
Resolved
CONDUCT TEST OF THE AIR BOTTLES IN BOTH LIFEBOATS TO INSURE THAT THE ^BOTTLES HAVE AT LEAST 1800 PSI.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Unknown
Issued 29 January 1986
Resolved
PROVIDE NON-RENEWABLE LINK TYPE FUSES FOR THE GENERAL ALARM SYSTEM.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Unknown
Issued 29 January 1986
Resolved
PROVIDE 1500 FOOT AUXILIARY LINE FOR THE IMPULSE ROCKET LINE THROWING GUN.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Unknown
Issued 29 January 1986
Resolved
REPAIR THE SAFETY CLIMB CABLE ON THE STARBORD STERN JACKING LEG.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Unknown
Issued 29 January 1986
Resolved
PROVIDE POLLUTION PLACARD ON BOARD THE RIG.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Unknown
Issued 29 January 1986
Resolved
REPLACE THE SELF CLOSING DEVICE ON THE PORT DOOR TO THE MUD PIT ROOM.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Unknown
Issued 29 January 1986
Resolved
CONDUCT TEST OF OVERSPEED TRIPS FOR NO. 1,2, AND 3 GENERATORS IN THE PRESENCE OF THE COAST GUARD.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Unknown
Issued 29 January 1986
Resolved
PROVIDE CHOCKING FOR THE BATTERIES LOCATED IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Unknown
Issued 29 January 1986
Resolved
REPLACE FALLS ON THE PORT DAVIT LAUNCH INFLATABLE LIFERAFT STATION AND LOADTEST FALLS AND RELEASE HOOK.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Fire Fighting
Issued 22 January 1986
Resolved
PROVIDE NON-CONDUCTIVE GLOVES FOR BOTH FIREMAN'S OUTFITS (46CFR108.497).
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Lifesaving
Issued 22 January 1986
Resolved
REPLACE FALLS ON THE PORT DAVIT LAUNCH INFLATABLE LIFE RAFT STATION AND LOAD FALLS AND RELEASE HOOK.
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Documentation
Issued 22 January 1986
Resolved
PROVIDE DOCUMENTATION ON BOARD THE VESSEL FOR THE DESIGNATION OF THE CRANE OPERATORS IN WRITING.
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Fire Fighting
Issued 22 January 1986
Resolved
PROVIDE RELIEF VALVES ON THE DISCHARGE SIDE OF THE FIRE PUMPS SET AT MAX OF125 PSI.
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Engineering
Issued 22 January 1986
Resolved
CONDUCT TEST OF OVER SPEED TRIPS FOR NO. 1, 2, AND 3 GENERATORS IN THE PRESENCE OF THE COAST GUARD.
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Lifesaving
Issued 22 January 1986
Resolved
CONDUCT TEST OF THE AIR BOTTLES IN BOTH LIFE BOATS TO INSURE THAT THE BOTTLES HAVE AT LEAST 1800 PSI.
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Lifesaving
Issued 22 January 1986
Resolved
REPAIR SAFETY CLIMB CABLE ON THE STARBOARD STERN JACKING LEG.
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Documentation
Issued 22 January 1986
Resolved
PROVIDE POLLUTION PLACARD ON BOARD THE RIG (33CFR155.450).
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Electrical
Issued 22 January 1986
Resolved
PROVIDE CHOCKING FOR THE BATTERIES LOCATED IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Fire Fighting
Issued 22 January 1986
Resolved
CLOSING DEVICE ON THE PORT DOOR TO THE MUD PIT ROOM.
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Fire Fighting
Issued 22 January 1986
Resolved
PROVICE NON-RENEWABLE LINK TYPE FUSES FOR THE GENERAL ALARM SYSTEM.
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Lifesaving
Issued 22 January 1986
Resolved
PROVIDE 1500' AUX FOR LINE THE IMPULSE ROCKET LINE THROWING GUN; 7/8" DIAM MANILA OR EQUAL.
Condition: Unknown
Due 22 January 1986
Resolved 22 January 1986
Unknown
Issued 16 May 1985
Resolved
OPEN AND CLEAN ALL DUMP VALVES FOR INSPECITON. THIS INCLUDES REMOVAL OF THE VALVE BONNETS.
Condition: Unknown
Due 16 May 1985
Resolved 16 May 1985
Construction/Loadline
Issued 21 April 1985
Resolved
MAKE THE BOTTOM OF BARGE HULL AVAILABLE FOR VISUAL EXAMINATION.
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Construction/Loadline
Issued 21 April 1985
Resolved
ALL SEA CHESTS, DUMP VALVES, AND OTHER THRU HULL SKIN VALVES MUST BE OPENED AND CLEANED FOR INSPECTION. THIS INCLUDES REMOVAL OF THE VALVE BONNETS.
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Unknown
Issued 12 December 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO SAM NOBLE, DN652389
Condition: Unknown
Due 12 December 1984
Resolved 12 December 1984
Unknown
Issued 12 December 1984
Resolved
PROVIDE AN APPROVED OXYGEN EXPLOSIVE METER ON BOARD THE VESSEL FOR EACH FIREMAN'S OUTFIT. 46CFR108.497(4).
Condition: Unknown
Due 12 December 1984
Resolved 12 December 1984
Unknown
Issued 12 January 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO SAM NOBLE, DN652389
Condition: Unknown
Due 12 January 1984
Resolved 12 January 1984
Electrical
Issued 12 January 1984
Resolved
PROVIDE GENERAL ALARM DEVICES SUITABLE FOR HARZARD LOCATIONS IN THE MUD PITAND DRILL FLOOR AREAS. 46 CFR 111.105.
Condition: Unknown
Due 12 February 1984
Resolved 12 January 1984
Electrical
Issued 12 January 1984
Resolved
PROVIDE A LOSS OF VENTILATION ALARM IN THE MUD PIT SPACE 46 CFR 108.170.
Condition: Unknown
Due 12 January 1984
Resolved 12 January 1984
Electrical
Issued 12 January 1984
Resolved
PROVIDE GENERAL ALARM CONTACT MAKER SUITABLE FOR HAZARDOUS LOCATIONS ON THE DRILL FLOOR 46 CFR 111.105.
Condition: Unknown
Due 12 February 1984
Resolved 12 January 1984