MAURY USCG vessel records Sign in
← All vessels

MARITIME RIYAL

MARITIME RIYAL is a 1998 tank ship. The Coast Guard has recorded 23 inspections since 1998, most recently in September 2016, along with 11 deficiencies and 2 operational controls, 2 with no removal date recorded.

Records from 1998 to 2016. Most recent: inspection, 19 September 2016.

Built
1998
Last inspected
19 September 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
2 with no removal date recorded

Identity

9143673 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
483124
Flag
MARSHALL ISLANDS
—
Maury page id
psix-483124

Inspections, by type

…with no type recorded10
Years with a record 8 calendar years (1998–2016)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29956 - Convention (Subpart B), Gross Ton
11997 - Convention (Subpart B), Net Ton
57609 - Displacement, Metric Ton
45363 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TORM THYRA Tank Ship · MISLE 650507 · 6 March 2006 · activity 2607275

Inspection history · 23

19 September 2016 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6000430
10 February 2012 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4242249
3 February 2012 Ballast Water Examination · COC-CHEM Annual · ISPS III Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4232023
9 April 2008 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3179892
27 October 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2809315
25 October 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2807695
25 October 2006 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2808067
6 May 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2642506
6 May 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2852003
25 April 2006 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2635630
6 March 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2607275
14 February 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2584911
30 January 2006 COC-CHEM Renew · Ballast Water Examination · ISPS III Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2571750
27 October 2005 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2523340
3 March 2005 COC-CHEM Annual · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · ISPS III Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2302205
15 February 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2293267
3 March 2004 MTSA/ISPS Verification · Certificate of Compliance
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2017100
17 July 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1647581
14 July 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1646158
11 July 2002 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1644863
29 November 1998 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1436153
27 November 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 423149
26 November 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 422933

Deficiency record · 11

Fire Fighting › Ventilation Systems › Ducts
Issued 3 February 2012 Resolved
0799 The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. Ventilation duct to the emergency generator space bent and unable to be closed. SOLAS 1997 CH II-2 Reg 16.9 - 16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2012
Resolved 10 February 2012
Resolution: Received Class report attesting to ventilation duct being repaired and properly operating.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 3 February 2012 Resolved
1240 Means for securing and maintaining weather tightness shall ensure that the tightness can be maintained in any sea conditions. 2 dogs on the #1 starboard tank ullage hatch seized and unable to close hatch properly. ICLL 1966 Annex I Reg 16 (4) - 10
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 February 2012
Resolved 3 February 2012
Resolution: Vessel replaced the two damaged Dogs and placed operational ones in their place. Hatch was then able to secure properly.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 3 February 2012 Resolved
1899 With any hazardous cargo, ullage hatches shall be open only when necessary. Bubbles from cargo vapors coming from gasket on the #1 port/starboard and #6 starboard ullage hatch gaskets. IBC Ch 16.4.1 - 10
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 February 2012
Resolved 3 February 2012
Resolution: Vessel was able to tighten all ullage hatch covers to secure bubbles. Also issued another deficiency for damaged dogs.
Lifesaving › Launching Appliances › Winch Brake
Issued 9 April 2008 Resolved
Brake on port side lifeboat/rescue boat failed during abandon ship drill. The lifeboat free fell to the water. Correct to the satisfaction of class and verify proper operation of stbd lifeboat prior to departure. SOLAS (2007) Ch III Reg 17
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2008
Resolution: Received Class report stating braking tests of both lifeboat launching appliances was carried out and was found satisfactory.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 30 January 2006 Resolved
5 Fire doors throughout the accommodation spaces do not fully close. Rectify to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 February 2006
Resolution: Received class report, cleared deficiency.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 January 2006 Resolved
Light on top of DFM room not grounded and has exposed internal wires - missing cover.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 January 2006
Resolution: Corrected on the spot.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 30 January 2006 Resolved
VCS missing pin at 12 o'clock with maniflold connected. Rectify to the satisfaction of class society.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 February 2006
Resolution: Received class report, cleared deficiency.
Deck/Cargo › Holds/Tanks › Ullage
Issued 30 January 2006 Resolved
Approximately 15 cargo tank/ullage openings leak to the atmosphere. Rectify to the satisfaction of class society.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 February 2006
Resolution: Received class report, cleared deficiency.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 30 January 2006 Resolved
Sight glass on deck seal and vacuum breaker is fractured. Rectify to the satisfaction of class society.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 February 2006
Resolution: Received class report, cleared deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 30 January 2006 Resolved
Framo pump number three control box/unit leaking on deck. Rectify to the satisfaction of class society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 February 2006
Resolution: Received class report, cleared deficiency.
Accommodation/Occupational Safety › Potable Water System › General
Issued 30 January 2006 Resolved
On deck emergency wash down/shower does not operate. Rectify to the satisfaction of class society
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 February 2006
Resolution: Received class report, cleared deficiency.