MAURY USCG vessel records
← All vessels

DB LONG BEACH

Built
1975
Last inspected
26 February 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 26 February 2026
…with no type recorded17
Operational controls None recorded without a removal date
Years with a record 41 calendar years (1984–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBP4749
Flag
UNITED STATES
Tonnage
2738 - Regulatory (Subpart C or D), Gross Ton 2471 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-48430
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

BRIAN T Towing Vessel · MISLE 418117 · 6 January 2005 · activity 2270536

Inspection history · 87

26 February 2026 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8316700
10 March 2025 Deficiency Check · Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8064835
16 January 2025 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8045285
5 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7849982
20 April 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7626983
28 March 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7411675
21 January 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7370078
22 January 2021 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7128864
10 April 2020 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6928252
6 January 2020 Administrative Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6875796
30 December 2019 Hull Examination · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6868726
16 October 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6836097
29 January 2019 Deficiency Check · Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6609228
28 February 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6366169
17 January 2017 Underwater Inspection in lieu of Drydock · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6060150
3 February 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5809117
12 January 2016 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5780046
27 May 2015 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5137318
17 March 2015 Drydock Extension · Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5085699
13 January 2015 Internal Structural Exam · Drydock Extension · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5048996
16 January 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4771721
10 July 2013 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4649588
20 December 2012 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4505351
12 January 2012 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4227355
9 January 2012 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4211123
28 September 2010 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3858974
22 July 2010 Drydock Extension · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3803087
28 January 2010 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3669604
11 January 2010 Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Extension
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3658632
9 April 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3448926
20 March 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3158186
22 May 2007 Hull Examination · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2969375
5 April 2007 Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2883500
4 January 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2808004
23 August 2006 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2757258
17 January 2006 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2562059
14 April 2005 Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2326240
23 February 2005 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2297982
6 January 2005 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2270536
26 March 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2034238
15 February 2002 Internal Structural Exam · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1494568
18 January 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1482276
17 January 2001 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1361992
1 June 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1373111
20 January 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440244
20 January 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1466586
25 August 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375472
20 January 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1442657
30 May 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1433217
20 March 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1104126
23 January 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380745
24 January 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1452103
17 August 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 876269
27 April 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 863681
15 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 866599
16 February 1995 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 848314
10 February 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1387701
13 May 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1354703
5 January 1994 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 851511
24 February 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1144638
14 May 1992 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 962314
30 March 1992 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 954713
26 February 1992 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 957153
8 April 1991 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 922574
1 March 1991 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1240506
11 January 1990 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 905520
23 May 1989 Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1041218
12 May 1989 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1346766
26 April 1989 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1345095
7 April 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1203021
5 December 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1207526
2 December 1988 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 896806
12 October 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 886709
16 September 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1041971
23 August 1988 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1039253
18 August 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1338399
17 July 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1328625
20 August 1986 Re-Inspection · Credit Drydock
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1025412
5 August 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 990833
31 July 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1306343
29 July 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 996166
15 August 1985 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 987034
19 July 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 986249
12 June 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1286690
5 March 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 979853
18 December 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1285221
29 November 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1283800

Deficiency record · 87

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2025 Resolved
Approved hand portable fire extinguishers and semiportable fire extinguishing systems shall be installed on all vessels, other than unmanned barges and fishing vessels, as set forth in subpart 95.50. Portable fire extinguishers were not currently serviced. 46 CFR 95.05-15 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 14 March 2025
Resolution: Servicing for portable fire extinguishers was completed by Breakwater International on 12MAR25
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 March 2025 Resolved
At each inspection for certification and periodic inspection the marine inspector must conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as they feel necessary to check safe operation. Vessel was not able to conduct over speed shut-down and low lube oil shut-down as per ABS 4-2-1 on two ship service diesel generators. 46 CFR 61.20-3 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 14 March 2025
Resolution: Conducted low L/O shutdown and overspeed shutdown on two CAT generators in the machinery space.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 March 2025 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Fuel filter was found to be leaking. 46 CFR 92.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 14 March 2025
Resolution: Witnessed new fuel filter that is not leaking.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 March 2025 Resolved
Three all-round lights in a vertical line where they can best be seen. The highest and lowest of these lights shall be red and the middle light shall be white. Vessel’s navigation lights were not operating properly. Vessel is restricted to daylight towing operations. 33 CFR 83.27 (b)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 14 March 2025
Resolution: Satisfactory witnessed picture of lights being on at night.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2025 Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern of the vessel under § 67.123 of part 67 of this chapter. Lifebuoys were found not to be properly marked with the vessel’s name. 46 CFR 199.70 (a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 27 March 2025
Resolution: Three life rings properly labeled with the vessel's name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 March 2025 Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.112 securely attached to the front shoulder area of the lifejacket. Eleven Lights were found to be expired. Vessel is restricted to carrying only 08 industrial personnel. 46 CFR CFR 199.70 (b)(4)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 14 March 2025
Resolution: Witnessed 11 new lights expiring in 2030 attached to life jackets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 March 2024 Resolved
The means for securing and maintaining weather tightness shall be to the satisfaction of the assigning authority. Watertight door leading in round house was found not watertight and securing dogs in poor state. Demonstrate proper securing of watertight door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 11 April 2024
Resolution: Proper maintenance carried out and watertight door operation proven satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2024 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Observed exposed wiring going into conduit boxes on exterior of round house. Make electrical installations safe for workers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 11 April 2024
Resolution: All wiring and lights replaced satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2024 Resolved
Each lifejacket must be marked in block capital letters with the name of the vessel. Mark all PDF's with vessel name "DB LONG BEACH"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 11 April 2024
Resolution: Lifejackets properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2024 Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Water light on ring buoy stored on exterior of round house was found with water in battery compartment; repair or replace light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 11 April 2024
Resolution: Water light replaced.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 5 March 2024 Resolved
A ship of 300 gross tons or more constructed after June 30, 1974 must have a fixed container or enclosed deck area under or around each fuel oil or bulk lubricating oil tank vent, overflow, and fill pipe. Oil containment on stern was found with a significant amount of standing water. Properly remove and dispose of oily mixtures or water in containment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2024
Resolved 11 April 2024
Resolution: Containment cropped and renewed satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 April 2023 Resolved
Vessel's over 1000 GT are required to have 02 fire pumps. #2 fire pump in not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2023
Resolution: Witness operation of #2 fire pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2023 Resolved
Life buoys must have the following attachments and fittings. A lifeline that is at least 100 feet in length. Lifeline on buoys range from 50-75 feet.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2023
Resolution: Witnessed installation of required lifeline.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 January 2021 Resolved
Replace 03 damaged life jackets.
Action required: 10 - Deficiency Rectified
Resolved 26 January 2021
Resolution: Replaced with spares.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 January 2021 Resolved
Install non-conducting mats or gratings of suitable voltage rating at the front and rear of switchboard. Due 09Feb2021.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2021
Resolved 29 January 2021
Resolution: Mats installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 January 2021 Resolved
Calibrate or replace ammeters, voltmeters and frequency meters on switchboard for both generators. Due 26Feb2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021
Resolved 29 January 2021
Resolution: Certificate provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2019 Resolved
Electrical switchboard in crane operating room missing drip shield and non-conductive handle as required by 46CFR111.30-5(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2019
Resolved 1 May 2019
Resolution: Non-conductive handle and drip shield installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 January 2019 Resolved
Exhaust piping on crane generataor was missing insulation to protect from heat injury in accordance with 46CFR56.50-1(k)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2019
Resolved 1 May 2019
Resolution: Insulation placed onto exhaust piping.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 January 2017 Resolved
Replace Fire Control plan as id.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 January 2017
Resolution: Def cleared
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 17 January 2017 Resolved
Replace 12 gaskets as id.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 January 2017
Resolution: Def Cleared
Communications › Alarms/Indicators › General Alarm
Issued 17 January 2017 Resolved
Replace battery for general alarm system
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 January 2017
Resolution: Def Cleared
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 January 2017 Resolved
Replace battery on Lifering as id
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 January 2017
Resolution: Def Cleared
Electrical › Electric Generation Source (service) › Generator
Issued 17 January 2017 Resolved
Test generartors with technicians on board for High Jacket water temp, Overspeed and low lube oil pressure.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 January 2017
Resolution: Def Cleared
Construction/Loadline › Markings › Load Line Mark
Issued 17 January 2013 Resolved
Deck Line was missing
Action required: 705 - Other - as specified
Due 18 February 2013
Resolved 23 January 2013
Resolution: Deck line was permanently affixed
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 28 January 2010 Resolved
Prove proper operation of the automated overspeeds, low lube oil pres, and jacket water shutdowns on the new cummins deck generator & DC crane generator.
Action required: 705 - Other - as specified
Due 15 April 2010
Resolved 24 August 2010
Resolution: Cummins REP conducted overspeed. low lube oil pres, and jacket water shutdowns on both generators.
Electrical › Electric Generation Source (service) › Generator
Issued 28 January 2010 Resolved
Submit plans for newly installed deck generator set for electrical, fuel, and associated modifications to USCG Sector LA-LB for approval.
Action required: 705 - Other - as specified
Due 15 April 2010
Resolved 17 August 2010
Resolution: Plans were submitted for review and approved by Sector LA/LB
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2010 Resolved
Make temporary repair to fractured weld in starboard bow rake #4 as marked
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2010
Resolved 5 February 2010
Resolution: Sighted proper repair
Lifesaving › Inflatable Liferafts › Painter
Issued 17 January 2006 Resolved
Secure Painter for both life rafts to weak line, IAW 46CFR199.175(b)21
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 7 February 2006
Resolution: Properly secured painter.
Lifesaving › Immersion Suits › Not on Board
Issued 17 January 2006 Resolved
Provide 4 immersion suites, person on board limited to 15. IAW 46CFR199.70(b)
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 7 February 2006
Resolution: Provided 4 immersion suites.
Engineering › Bilge Water Management System › Not Operational
Issued 17 January 2006 Resolved
Prove proper operation of bilge pump. IAW 46CFR96.03-1
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 7 February 2006
Resolution: Operated bilge pump.
Engineering › Fuel Oil Service System › Hose
Issued 17 January 2006 Resolved
Replace worn fuel hose supply lines on both ship service generator.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 28 February 2006
Resolved 7 February 2006
Resolution: Replaced hoses.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 January 2006 Resolved
Remove material from starboard light for112,5 visibility of light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 7 February 2006
Resolution: Rplaced starboard light cover.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 17 January 2006 Resolved
Provide mechanical limiting device to prevent parallel operation of ships service generator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 7 February 2006
Resolution: Provided mechanical device that would restrict parallel operation.
Engineering › Generator (propulsion-electric)
Issued 26 March 2004 Resolved
Replace single hose clamps with double hose clamps on all flex hose on port and starboard generators
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 12 April 2004
Resolution: Digital photos provided of MDE with new double hose clamps.
Engineering › Generator (propulsion-electric)
Issued 26 March 2004 Resolved
Provide machinery guard on swing tachometer
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 12 April 2004
Resolution: Digital photo provided of new machinery guard placed over tacometer.
Pollution Prevention/Response › Prevention Equipment
Issued 26 March 2004 Resolved
Provide waste management plan IAW 33 CFR 151.157
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 12 April 2004
Resolution: Copy of waste management plan faxed to office.
Lifesaving › Lifejacket/PFD (General)
Issued 26 March 2004 Resolved
Replace retro-reflective tape on eleven lifejackets LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 12 April 2004
Resolution: New tape placed on all 11 life jackets.
Engineering › Generator (propulsion-electric)
Issued 26 March 2004 Resolved
Place chaffing gear on flex hose on starboard generator
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 12 April 2004
Resolution: Digital photo provided of new chaffing gear placed on starboard generator
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 26 March 2004 Resolved
Replace overhead lighting in aft ships office with protective covers LEGACY COMPONENT DESC: Recreation Space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 12 April 2004
Resolution: Overhead replaced in ships office.
Documentation › Certificates/Documents › IOPP Certificate
Issued 26 March 2004 Resolved
Expired IOPP Certificate noted
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 1 April 2004
Resolution: Issued new IOPP certificate to vessel.
Construction/Loadline › Hull
Issued 15 February 2002 Resolved
LARGE INSETS AND CRACKS NOTED IN AFT RAKES HULL PLATING: STBD RAKE-AFT CORNER, AND INBOARD PORT RAKE AFT. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2002
Documentation
Issued 20 January 1999 Resolved
DURG TESTING POLICY AND RESULTS WERE NOT ON BOARD FOR INSPECTION.
Condition: Unknown
Due 5 February 1999
Resolved 13 February 1999
Electrical
Issued 20 January 1999 Resolved
EMERGENCY LIGHTING ON BOARD NEEDS TO BE KEPT ON WHILE THE BARGE IS MANNED AND 3 LIGHTS WERE NOT WORKING AND NEED TO BE REPLACED.
Condition: Unknown
Due 5 February 1999
Resolved 13 February 1999
Accommodation/Occupational Safety
Issued 20 January 1999 Resolved
PRESSURE RELIEF VALVES ON BOTH PRESSURE VESSEL'S IN THE CRAIN ROOM HAVE TO BE REPLACED AS THEY DO NOT RELIEVE BELOW 200 PSI THE MAX WORKING PRESSURE OF THE TANKS.
Condition: Unknown
Due 5 February 1999
Resolved 13 February 1999
Electrical
Issued 20 January 1999 Resolved
OVERSPEED ON # 2 GENERATOR WOULD NOT SHUT DOWN THE GENERATOR WHEN PUT INTO USE.
Condition: Unknown
Due 5 February 1999
Resolved 13 February 1999
Construction/Loadline
Issued 20 March 1997 Resolved
DRYDOCK EXAMINATION EXTENDED. DRYDOCK THE VESSEL NO LATER THAN _x001C_ 31 MAY 1997.
Condition: Unknown
Due 20 March 1997
Resolved 20 March 1997
Electrical
Issued 10 February 1995 Resolved
REPAIR EMERGENCY LIGHT IN MSD ROOM.
Condition: Unknown
Due 17 February 1995
Resolved 22 February 1995
Accommodation/Occupational Safety
Issued 10 February 1995 Resolved
REPAIR THE GENERAL ALARM SWITCH IN WAY OF THE STBD PASSAGEWAY BELOW DECK.
Condition: Unknown
Due 17 February 1995
Resolved 22 February 1995
Electrical
Issued 10 February 1995 Resolved
PROVE THE PROPER OPERATION OF THE STBD SERVICE GENERATOR OVERSPEED AND LOW LUBE OIL SHUTDOWN.
Condition: Unknown
Due 17 February 1995
Resolved 22 February 1995
Lifesaving
Issued 10 February 1995 Resolved
REPLACE ALL OUTDATED LIFEJACKET LIGHTS STOWED ON THE MAIN DECK.
Condition: Unknown
Due 17 February 1995
Resolved 22 February 1995
Accommodation/Occupational Safety
Issued 10 February 1995 Resolved
REPAIR GENERAL ALARM BELLS IN THE SERVICE GENERATOR ROOM AND STARBOARD PASSAGEWAY BERTHING AREA BELOW DECK.
Condition: Unknown
Due 17 February 1995
Resolved 22 February 1995
Electrical
Issued 24 February 1993 Resolved
PROVE PROPER OPERATION OF THE REVERSE POWER RELAYS ON BOTH GENERATORS IN THE AFTER MACHINERY SPACE.
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Electrical
Issued 24 February 1993 Resolved
PROVE PROPER OPERATION OF THE OVERSPEED TRIPS ON THE TWO (2) AFTER MACHINERY SPACE GENERATORS (10 TO 15% ABOVE NORMAL OPERATING RPM).
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Documentation
Issued 24 February 1993 Resolved
PROVIDE PROOF OF ANNUAL LOADLINE CERTIFICATE ENDORSEMENT.
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Fire Fighting
Issued 1 March 1991 Resolved
PROVIDE APPROVED FIRE CONTROL PLANS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Lifesaving
Issued 23 August 1988 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Electrical
Issued 23 August 1988 Resolved
CKT BKR PANEL 208(B-1), BLOCK-OUTS, LOWER RIGHT-HAND CORNER, MISSING. ENSURE PROPER INSTALLATION.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Lifesaving
Issued 23 August 1988 Resolved
RECHARGE O2 BOTTLE LOCATED IN HOSPITAL.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Documentation
Issued 23 August 1988 Resolved
RENEW FCC LICENSE. PRESENT LICENSE IS EXPIRED.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Electrical
Issued 17 July 1987 Resolved
REMOUNT SPEED SWITCH BOX ON EMERGENCY GENERATOR.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Fire Fighting
Issued 17 July 1987 Resolved
RECHARGE AIR BOTTLE FOR BREATHING APPARATUS (FORWARD HOUSE).
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Fire Fighting
Issued 17 July 1987 Resolved
HAVE 3 PORTABLE CO2 FIRE EXTINGUISHERS AND 1 B-V SEMI-PORTABLE BOTTLE HYDROSTATICALLY TESTED.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Lifesaving
Issued 17 July 1987 Resolved
HAVE ALL 4 INFLATABLE LIFERAFTS AND HYDROSTATIC RELEASES SERVICED.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Electrical
Issued 17 July 1987 Resolved
DEMONSTRATE OPERATION OF OVERSPEED TRIP ON EMERGENCY GENERATOR.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Engineering
Issued 17 July 1987 Resolved
TEST RELIEF DEVICE AND OPEN FOR EXAMINATION AIR RECEIVER (SMALL ONE) IN CRANE STRUCTURE.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Lifesaving
Issued 17 July 1987 Resolved
PROVIDE 3 ADDITIONAL ADULT LIFE JACKETS WITH LIGHTS.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Lifesaving
Issued 17 July 1987 Resolved
PROVIDE 12 IMMERSION SUITS WITH LIGHTS.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Navigation
Issued 17 July 1987 Resolved
REPAIR PORT SIDELIGHT.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Documentation
Issued 17 July 1987 Resolved
PROVIDE OIL TRANSFER PROCEDURES AND PERSON IN CHARGE DESIGNATION.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Electrical
Issued 17 July 1987 Resolved
REMOVE NO LONGER USED HEATER WIRING IN GALLEY (OR REINSTALL HEATER).
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Engineering
Issued 17 July 1987 Resolved
PROVIDE NEW ASME RELIEF DEVICE FOR LARGER AIR RECEIVER IN CRANE STRUCTURE.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Lifesaving
Issued 17 July 1987 Resolved
RENEW BATTERIES IN WATERLIGHTS ON RINGBUOYS (AFT).
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Fire Fighting
Issued 29 November 1984 Resolved
PROVIDE FIRE CONTROL PLANS.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Electrical
Issued 29 November 1984 Resolved
INSTALL SUITABLE COVERS OVER THE REMOVED CIRCUIT BREAKERS IN PANEL LP-408.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Navigation
Issued 29 November 1984 Resolved
REPAIR/REPLACE THE EPIRB.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Fire Fighting
Issued 29 November 1984 Resolved
PROVIDE AN APPROVED FIXED FIRE FIGHTING SYSTEM FOR PAINT LOCKER LOCATED ON THE FORWARD MAIN DECK.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Navigation
Issued 29 November 1984 Resolved
DEMONSTRATE THE PROPER OPERATION OF THE GENERAL ALARM ROTATING BEACON IN THE GENERATOR SPACE.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Construction/Loadline
Issued 29 November 1984 Resolved
MAKE PROPER REPAIRS TO THE HOLE IN THE UNDERDECK FRAME LOCATED ABOVE THE STARBOARD GENERATOR.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Engineering
Issued 29 November 1984 Resolved
REPAIR/REPLACE THE REMOTE SHUTDOWN FOR THE MAIN DECK FUEL OIL TRANSFER PUMP
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Engineering
Issued 29 November 1984 Resolved
PROPERLY LABEL THE REMOTE SHUTDOWN FOR THE FUEL OIL TRANSFER PUMP LOCATED IN THE GENERATOR SPACE.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Lifesaving
Issued 29 November 1984 Resolved
PROVIDE TWO ADDITIONAL ORANGE SMOKE FLARES.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Electrical
Issued 29 November 1984 Resolved
PROPERLY MARK ALL EMERGENCY LIGHTS.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Documentation
Issued 29 November 1984 Resolved
PROVIDE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Navigation
Issued 29 November 1984 Resolved
REPAIR/REPLACE THE RELIEF VALVE FOR THE CRANE MACHINERY STARTING AIR RECEIVER.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Construction/Loadline
Issued 29 November 1984 Resolved
PROPERLY MARK THE FLAMMABLE LIQUID LOCKER.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Fire Fighting
Issued 29 November 1984 Resolved
HYDROSTATICALLY TEST THE FOUR PORTABLE CO-2 EXTINGUISHERS.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984
Construction/Loadline
Issued 29 November 1984 Resolved
REPAIR/REPLACE THE CRUCIFORM MOORING BITT LOCATED AFT, STARBOARD SIDE.
Condition: Unknown
Due 29 November 1984
Resolved 29 November 1984

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.